• 제목/요약/키워드: Violent sloshing

검색결과 15건 처리시간 0.021초

Experimental study on characteristic of sloshing impact load in elastic tank with low and partial filling under rolling coupled pitching

  • Wu, Wenfeng;Zhen, Changwen;Lu, Jinshu;Tu, Jiaoyang;Zhang, Jianwei;Yang, Yubin;Zhu, Kebi;Duan, Junxian
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제12권1호
    • /
    • pp.178-183
    • /
    • 2020
  • A series of experiments covering lowest three natural frequencies of rolling coupled pitching were conducted to investigate liquid sloshing with low liquid depth. The test results show that the most violent liquid sloshing in rolling and pitching is located in the vicinity of the first order natural frequency (f1). When the excitation frequency of rolling and pitching is located between 0.98f1 and 1.113f1, roof-bursting phenomenon of liquid appeared, and the maximum impact pressure is at 1.09f1. When the external excitation frequency is at 1.113f1, the number of sloshing shocks decreases sharply. Furthermore, the space distribution of the impact pressure on the left bulkhead and the top bulkhead was analyzed. It is concluded that with low liquid filling, the impact load is greater near the free surface and the top of tank, and the impact position of the side bulkhead increases with the increasing of the frequency near the resonant frequency.

160K LNGC 멤브레인 화물창에 작용하는 슬로싱 충격 하중에 대한 비교 실험 연구 (Comparative Experimental Study on Sloshing Impact Loads of LNG Cargoes in Membrane Containment System of 160K LNGC)

  • 권창섭;이영진;김현조;이동연
    • 대한조선학회논문집
    • /
    • 제56권2호
    • /
    • pp.103-108
    • /
    • 2019
  • A new state-of-the-art sloshing research equipment has developed to perform the model test of LNG tanks for the safer design of LNG cargo containment system in violent sloshing phenomena. This sloshing test system has developed by the Samsung Ship Model Basin (SSMB) and thoroughly verified. The accuracy of the motion of hexapods equipment for the excitation of a model tank has been verified. The maximum displacement in six degrees of freedom, harmonic motions of various frequencies, and irregular motions in wave conditions are measured and compared with input signals. In order to confirm the reliability of the post-processing program for measured impact pressure, the post-processed results were compared with those of the reference institute. A benchmarking sloshing test using 1/50 scale model of 160K LNGC tank was conducted for the verification of the whole testing system. The partial filing levels were considered. As a result of the experiment, it is confirmed that the results are in good agreement with those of the reference institute.

SPH 기법의 계산인자 민감도에 대한 연구 (Study on the Effects of Computational Parameters in SPH Method)

  • 김유일;남보우;김용환
    • 대한조선학회논문집
    • /
    • 제44권4호
    • /
    • pp.398-407
    • /
    • 2007
  • A smoothed particle hydrodynamics (SPH) method is applied for simulating two-dimensional free-surface problems. The SPH method based on the Lagrangian formulation provides realistic flow motions with violent surface deformation, fragmentation and reunification. In this study, the effect of computational parameters in SPH simulation is explored through two-dimensional dam-breaking and sloshing problem. The parameters to be considered are the speed of sound, the frequency of density re-initialization, the number of particle and smoothing length. Through a series of numerical test. detailed information was obtained about how SPH solution can be more stabilized and improved by adjusting computational parameters. Finally, some numerical simulations for various fluid flow problem were carried out based on the parameters chosen through the sensitivity study.

단순화된 Mark III 방열판의 구조 강도 평가에 관한 연구 (Structural Strength Assessment of Simplified Mark III CS Plate)

  • 정한구;양영순
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2011년도 정기 학술대회
    • /
    • pp.539-543
    • /
    • 2011
  • LNG cargo containment system (CCS) has the primary function of ensuring adequate thermal insulation with keeping natural gas below its boiling point. From the viewpoint of structural design, this LNG CCS can be treated as a laminated composite structure showing complex structural responses under the sloshing load which can be defined as a violent behavior of the liquid contents in cargo tanks due to external forced motions. As LNG CCS type, Mark III containment system from TGZ is considered in this paper and then its structural strength assessment is performed based on a simple higher-order shear deformation theory and maximum stress, maximum strain, Tsai-Wu failure criteria developed for laminated composite plates. The assessment is performed to the initial failure of the Mark III CS plate by investigating failure locations and loads.

  • PDF

직교이방성 복합재료의 극저온 재료 물성치를 고려한 LNG CCS의 강도 평가에 관한 연구 (Strength Assessment of LNG CCS using Strength Analysis Method for Composite Materials)

  • 정한구;양영순
    • 대한조선학회논문집
    • /
    • 제51권2호
    • /
    • pp.114-121
    • /
    • 2014
  • Liquefied natural gas(LNG) cargo containment system(CCS) has the primary function of ensuring both adequate structural safety with respect to sloshing load which is defined as a violent behaviour of the liquid contents in CCS due to external forced motions and thermal insulation keeping natural gas below its boiling point. Among different LNG CCS types such as independent B-type and membrane ones, Mark III CCS is considered in this paper to perform its strength assessment. Mark III CCS plate is designed and constructed by stacking various non-metallic engineering materials such as plywood, triplex, reinforced PU foam that are supported by series of mastic upon inner steel hull structure. From the viewpoint of structural analysis, this plated structure is treated as a laminated composite structure showing complex structural behaviour under external load. Advanced finite element models of Mark III CCS plate is generated and used in conjunction with ultimate strength based failure criteria from laminated composite mechanics for the strength assessment. The strength assessment is performed within the initial failure state of Mark III CCS plate. Results provide failure details such as failure locations and loads. Finally obtained results are reviewed using the loads from acceptance criteria suggested by classification.