• Title/Summary/Keyword: View angle

Search Result 798, Processing Time 0.027 seconds

Thickness and Angle Dependent Microcavity Properties in Top-Emission Organic Light-Emitting Diodes (상부 발광 유기 발광 소자에서 두께와 시야각에 따른 마이크로 캐비티 특성)

  • Lee, Won-Jae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.1
    • /
    • pp.32-35
    • /
    • 2011
  • Top-emission device has a merit of high aperture ratio and narrow emission spectrum compared to that of bottom-emission one. Emission spectra of top-emission organic light-emitting diodes depending on a layer thickness and view angle were analyzed using a theory of microcavity. Device structure was manufactured to be Al (100 nm)/TPD/$Alq_3$/LiF (0.5 nm)/Al (2 nm)/Ag (30 nm). N,N'-diphenyl-N,N'- di (m-tolyl)-benzidine (TPD) and tris (8-hydroxyquinoline) aluminium (Alq3) were used as a hole-transport layer and emission layer, respectively. And a thickness of TPD and Alq3 layer was varied in a range of 40 nm~70 nm and 60 nm~110 nm, respectively. Angle-dependent emission spectrum out of the device was measured with a device fixed on a rotating plate. Since the top-emission device has a property of microcavity, it was observed that the emission spectrum shift to a longer wavelength region as the organic layer thickness increases, and to a shorter wavelength region as the view angle increases. Layer thickness and view-angle dependent emission spectra of the device were analyzed in terms of microcavity theory. A reflectivity of semitransparent cathode and optical path length were deduced.

Assessment of Congruence Angle according to the Central X-ray in the Merchant View of Patellofemoral Joint (슬대퇴관절의 Merchant View에서 중심 X선 위치에 따른 일치각 평가)

  • Kim, Hyun-jin;Joo, Yeong-chul;Choi, Jae-ho;Lim, Woo-taek
    • Journal of radiological science and technology
    • /
    • v.42 no.6
    • /
    • pp.423-428
    • /
    • 2019
  • The Precise measurement of the knee's Congruence angle is required for diagnosis of patella dislocation. The purpose of this study is to consider the distortion diagram and usefulness about the test of the bilateral side and one side through the evaluating congruence angle from Merchant view of patellofemoral joint to central X-ray. We've evaluated the sulcus angle and Congruence angle following central X-ray's changes when we took Merchant view of patellofemoral joint aimed to right lower limb from human whole body phantom. The subject of the evaluation was classified as normal group and varus group, and the varus group has experimented with External rotation of legs as 15° and 30°. When normal groups result as 0, 7.5, 15 cm, it was measured as 17.25 ± 1.34°, 19.60 ± 1.41°, 20.55 ± 1.77° each. The gap between minimal and maximum angle was 3.3°, and the value was shown as getting bigger when it further away from the centeral X-ray. When Congruence angle in 15° varus group was 0, 7.5, 15 cm, it was each 16.45 ± 1.34°, 17.10 ± 0.99°, 17.80 ± 1.13°. And when Congruence angle in 30° varus group was 0, 7.5, 15 cm, it was measured each 18.35 ± 1.63°, 18.95 ± 1.06°, 19.60 ± 1.41°. The difference between minimum and maximum of angle in 15° varus group and 30° varus group was each 1.35° and 1.25°, the angles have shown as increasing the further away from the center. The patellofemoral joint showed that the congruence angle increases as the further away from Central X-ray, and also it is judged that is possible to change the congruence angle by a degree of varus knee. Thus, accurate measurement of the congruence angle is shown to advantage that methods for examining by split each side at two times than methods for examining both sides at a time. Therefore, it is expected to helpful on the diagnostic side of patella dislocation and subluxation.

Development of Analysis System for Display Characters of FPD (FPD 화상특성 평가시스템 개발)

  • 송준엽;박화영;김현종;정연욱;김용래
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.335-338
    • /
    • 2004
  • In this study has developed analysis system for automatic inspection of FPD(Flat Panel Display) characteristic, such as brightness, view angle, color ratio in the manufacturing process. Developed system consists of inspection-sensor part, acquiring a data by 3-CCD Color CCD camera and Inspection-stage part, driving a FPD holder to rotation and tilt direction. In experiment results, we could have ensured easily brightness distribution, available view angle, color reproduce and could expect to improve the quality, productivity, and yield.

  • PDF

A new X-ray cross-sectional image system for solder joint inspection of double-sided PCB (양면 PCB의 납땜부 검사를 위한 새로운 X선 단층영상 시스템)

  • 강성택;정재훈;조형석
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.117-120
    • /
    • 1996
  • In this paper, a new approach to acquire the cross-sentional image for automatic solder joint inspection of double-sided PCB using X-ray source is presented. We designed the apparatus with fixed X-ray source to realize the cross-sectional image by tunning object and detector synchronously. The cross-sectional images are captured at several view angle of X-ray source, the geometric image distortions caused by view angle and the shape of image intensifier are compensated. The precision variation of cross-sectional image by the change of view angle was investigated. Also we acquired the cross-sectional image to the solder joint of double-sided PCB and reconstructed the shape of solder joint.

  • PDF

Multi-View Image Parking Assistant System using Vehicle Data (차량 정보를 이용한 멀티뷰 영상 주차 보조 시스템)

  • Lee, Min-Goo;Jung, Kyung-Kwon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.2
    • /
    • pp.266-272
    • /
    • 2012
  • This paper presents a parking assistant system of multi-view using vehicle data. Proposed system provides the driver with three direction of the scenes surrounding vehicle. Depending on the handle rotation, the proposed system displays views from multiple wide-angle CCD cameras on the laptop screen to reduce blind spots, support smooth parallel or garage parking, and support comfortable and safe driving. The handle angle and gear position are obtained from ABS ECU through OBD-II port. The performance of proposed system is validated by vehicle experiments.

Radiological Analysis of Osteoarthritis of the Second Metatarsophlangeal and Tarsometatarsal Joint (제2 중족 족지 및 중족 설상 관절의 관절염에 대한 방사선학적 분석)

  • Kim, Jung-Rae;Kim, Sung-Yoon;Lee, Woo-Chun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.16 no.2
    • /
    • pp.101-107
    • /
    • 2012
  • Purpose: The aim of this study was to investigate the radiological characteristics of the osteoarthritis of the second metatarsophalangeal (MTP) and tarsometatarsal (TMT) joint. Materials and Methods: Between January 2002 and August 2010, 27 patients (33 feet) who had second metatarsal osteoarthritis (OA) were reviewed retrospectively. Group 1 was 14 patients (17 feet) with second MTP joint OA. Group 2 was 13 patients (16 feet) with second TMT joint OA. Group 3 was 24 patients (25 feet) had hallux valgus without second metatarsal (MT) OA as control. Weight bearing foot anteroposterior (AP) and lateral view were checked, and measured hallux valgus angle, metatarsus adductus angle (MAA), second MT functional length, first and second MT length by Hardy & Clapham method on AP view, angle of second MT with horizontal plane, calcaneal pitch, talo-first MT on lateral view. Results: On weight bearing foot AP view, second MT functional length of group 1, 2, 3 was 2.4 mm, -0.1 mm, 0.7 mm and MAA of group 1, 2, 3 was $17.7^{\circ}$, $17.7^{\circ}$, $14.5^{\circ}$. Second MT functional length of group 1 was longer than control group and it was statistically significant. MAA was significant different between group 1-3 and group 2-3. Angle of second MT with horizontal plane of group 2 was smaller than control group and it was statistically significant. Other radiographic parameters have no statistical significance. Conclusion: Group 1 has long functional length of second MT and group 2 has small angle of second MT with horizontal plane.

Analysis and Evaluation of Multi-view UCV(User Created Video) Service through Adjusting Camera Angle (카메라 앵글 조정 방식을 통한 다시점 UCV(User Created Video) 서비스 분석과 평가)

  • Sung, Bokyung;Ko, Ilju
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.2
    • /
    • pp.39-47
    • /
    • 2014
  • Fast advancement and dynamic diffusion of Smart device make big change to personal user. They have been extended from consumer only watching video to prosumer recording and sharing User Created Video(UCV). With this reason, as a platform for various kind of content service. Especially, UCVs for the purpose of sharing experience are recorded from same event on limited time and space by some people. These are also produced by various cameras that has each angle similar like broadcasting videos. In this paper, we present multi-view characteristic of UCV and propose Multi-view UCV service that is watching UCVs from same event through adjusting camera angle. Through user satisfaction survey, we knew that adjusting camera angle is preferred for watching UCV including overlapping part more than linear watching.

Improvement of Color Temperature Uniformity of Integrated Optic Lens Type LED Packaged using Compression Molding Method (가압성형 방식을 사용한 렌즈 일체형 LED 패키지의 색온도 균일성 향상에 관한 연구)

  • Kim, Wan-Ho;Kang, Young-Rae;Jang, Min-Suk;Joo, Jae-Young;Song, Sang-Bin;Kim, Jae-Pil;Yeo, In-Seon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.4
    • /
    • pp.1-7
    • /
    • 2013
  • Optical characteristics including the view angle and color temperature uniformity of LED packages with an integrated lens fabricated by compression molding method are investigated according to lens shape, lens materials, and phosphor coating methods. Four types of lens shape are designed and their optical output power dependence on the refractive index of silicone encapsulant are evaluated. Also, spatial color temperature uniformities of packages fabricated with different phosphor coating methods-direct coating on a chip vs. uniformly mixed with silicone encapsulant- are compared at various view angles. As the result, it is found that phosphor coating method is more effective on color temperature uniformity than lens shape. The maximum color temperature difference of a package with direct coating of phosphor on a chip is 1,340K according to the view angle at the color temperature of 5,000K, and that of a package with uniformly mixed phosphor is 250K, which indicates 1,090K improvement of color uniformity for the latter case.

Optical Characteristics of Sheetless LCD Backlight Using Micro Reverse-pyramid Array (Micro Reverse-pyramid Array를 이용한 일체형 Sheetless LCD Backlight의 광학적 특성)

  • Jeon, Hwa Jun;Lim, Gyo Sung;Gwag, Jin Seog;Kwon, Jin Hyuk
    • Korean Journal of Optics and Photonics
    • /
    • v.23 no.3
    • /
    • pp.119-123
    • /
    • 2012
  • The structure of an LCD backlight unit (BLU) was simplified by installing a micro reverse-pyramid array (MRPA) or a micro reverse-cone array (MRCA) on the top surface of the light guide panel (LGP) in order to eliminate the conventional diffuser sheet and the prism sheet. The optimum conditions of the MRPA and the MRCA in the new light guide panel were obtained through optical simulation. The change of the luminance and view angle that depend on the side angle, the height, and the length at the top of the MRPA and MRCA were studied. The optimized side angle and the view angle of the MRPA and MRCA were 59 and 57 degrees for the side angles and 68 and 64 degrees for the view angles, respectively.

A Study on the Mechanical Mechanism According to the Groove Shape of T-welded Joint (T-joint 용접부의 형상에 따른 역학적 메카니즘에 관한 연구)

  • 방한서;김종명
    • Journal of Welding and Joining
    • /
    • v.17 no.6
    • /
    • pp.53-61
    • /
    • 1999
  • The use of thick plate in increasing in recent years due to the rapid expansion of chemical plants, nuclear plants, ships and other industrial plants. Welding is the most popular joining techniques employed in manufacturing industrial machineries and structures. Normally, Groove shapes are prepared according to appropriate rules and regulations such as KS, JIS, AWS, LR, DNV and etc. for various thicknesses of plate. However those groove angles tend to be too large. As a result of large groove angle, residual stress, deformation of material and strength reduction is obtained. Therefore, the reliability and safety of structures and machinery tend to be decreasing. Therefore, in this paper, theoretical as well as experimental study are carried out to find optimum groove shapes for T-welded joint of mild steel. The test specimen are made in same condition with simulation model. Welding residual stresses measurement by sectional cutting method. ⅰ) The mechanical difference for change the thickness of plate and groove angle are not appeared. ⅱ) In a mechanical point of view minimum preparation angle(40°) is more suitable than maximum groove angle(60℃). ⅲ) The measurement value and distribution of welding residual stresses are not effected largely by groove angle. It is mechanical restraint that mainly affect welding residual stresses distribution. In mechanical point of view minimum groove angle is more suitable than maximum groove angle. Therefore, it is appropriate to minimize the size of groove shape in strength and safety.

  • PDF