• 제목/요약/키워드: Vibrational Power

검색결과 133건 처리시간 0.025초

파워흐름해석법을 이용한 상선의 수중방사소음해석 (Underwater Radiated Noise Analysis for Commercial Ship Using Power Flow Analysis)

  • 권현웅;홍석윤;송지훈
    • 한국해양공학회지
    • /
    • 제26권4호
    • /
    • pp.30-36
    • /
    • 2012
  • Recently, the underwater radiated noises generated from large commercial ships have become a globally important issue. Countries with large ports and environmental protection organizations demand strict safety guidelines in relation to underwater radiated noise. In this paper, the coupled PFFE/PFBE method is used to investigate the vibration and underwater radiated noise of a commercial ship. PFFEM is employed to analyze the vibrational responses of the commercial ship, and PFBEM is applied to analyze the underwater radiation noise. The vibrational energy of the structure is treated as an acoustic intensity boundary condition of PFBEM to calculate the underwater radiation noise. Numerical simulations are presented for the commercial ship under various frequencies, and reliable results are obtained.

진동 파워흐름 측정을 통한 SUV용 엔진 마운트의 에너지 전달 기여도 분석에 관한 연구 (A Study on the Transmitted Energy Contribution Analysis of SUV Engine Mount by Vibration Power Flow Measurement)

  • 김수곤;이상권;김성종
    • 한국소음진동공학회논문집
    • /
    • 제18권4호
    • /
    • pp.400-410
    • /
    • 2008
  • Reduction of structure-borne noise in the compartment of a car is an important task in automotive engineering. Many methods which analyze noise transfer path have been generally used for structure-borne noise. These methods are useful in solving particular problem but do not quantify the effectiveness of vibration isolation for each isolator of a vehicle. To quantify the effectiveness of vibration isolation, the vibrational power flow measurement has been used for a simple isolation system or a laboratory based isolation system. This paper identifies the transfer path of booming noise in a SUV. The powertrain used for test has a in-line 4cylinder engine and 5-shift auto-transmission. This powertrain is transversely supported by four isolators. We calculated the energy flow throughout four isolator by the measurement of power flow and the contribution of energy flow at each isolator.

Structural Intensity 법을 이용한 구조체의 진동전달량 측정 (Measurements of the Vibrational Power Flow in Structure Beam by Using the Structural Intensity Method)

  • 김흥식
    • 소음진동
    • /
    • 제4권2호
    • /
    • pp.231-238
    • /
    • 1994
  • This paper presents an experimental method to find the vibrational transmission characteristics of structures by using the structural intensity method which is used as the important techniques of active vibration control method. Experimental results are obtained from measurements performed on a structure beam by 2, 3 and 4 position linear accelerometr array (2, 3 and 4 structural intensity : 2, 3 and 4 S.I.) methods at near and farfield conditions. These results are compared with the measurement values of conventional power flow measurement method called input power measurement in order to verify the accuracy of structural intensity methods. To minimize the errors associated with 2, 3 and 4 S.I. methods, the measurement locations were selected by the result of modal analysis and the averaged data by the inter-change of accelerometer array was utilized. In 3 and 4 S.I. methods measured wavenumber instead of theoretical wavenumber was used. This paper shows that measurements of bending wave power flow by using 2, 3 and 4 S.I. methods can give accurate values under general field conditions in structural beam and the accuracy of 2, 3 S.I. methods is higher than 4 S.I. methods. Finally, 2 position linear accelerometer array method is suggested as the practical structural intensity technique.

  • PDF

파력을 이용한 하이브리드 발전에 대한 연구 (The Research of the Hybrid Power Generation using Ocean Wave)

  • 한기봉;이형우
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제35권6호
    • /
    • pp.861-866
    • /
    • 2011
  • 본 논문에서는 파도의 상하운동에 의해 발전되는 형발전시스템과 진동발전시스템이 결합된 하이브리드 발전방법을 제안한다. 선형발전시스템은 권선과 영구자석으로 구성되어있고, 파도의 상하운동속도를 직접적으로 사용하므로 파도의 주파수에 관계없이 안정적인 발전을 한다. 그리고 진동발전시스템은 진동시스템인 영구자석, 스프링과 발전시스템인 영구자석, 권선으로 구성되어 있다. 진동발전시스템은 파도의 주파수와 진동시스템의 고유진동수를 일치시킨 공진대역에서 구동함으로써 파도의 상하운동 속도보다 더 큰 속도를 이용하여 더 많은 전기에너지를 얻을 수 있다. 따라서 본 연구에서 제안한 하이브리드 파력발전방법은 공진영역에서 더 많은 전기에너지를 얻을 수 있을 뿐만 아니라 공진영역을 벗어난 대역에서도 안정적으로 발전할 수 있는 장점을 가짐을 알 수 있다.

중고주파수 대역의 회전형 압축기 진동소음 해석 (Vibration and Noise Analysis for Rotary Compressor in Medium-to-high Frequency Ranges)

  • 권현웅;송지훈;홍석윤;하종훈
    • 한국소음진동공학회논문집
    • /
    • 제22권11호
    • /
    • pp.1033-1041
    • /
    • 2012
  • Power flow analysis(PFA) is introduced for solving the noise and vibration analysis of system structures in medium-to-high frequency ranges. The vibration analysis software, $PFADS_{C++}$ R4 based on power flow finite element method(PFFEM) and the noise prediction software, $NASPFA_{C++}$ R1 based on power flow boundary element method(PFBEM) are developed. In this paper, the coupled PFFE/PFBE method is used to investigate the vibration and radiated noise of the rotary compressor. PFFEM is employed to analyze the vibrational responses of the rotary compressor, and PFBEM is applied to analyze the radiation noise around rotary compressor. The vibrational energy of the structure is used as an acoustic intensity boundary condition of PFBEM. Numerical simulations are presented for the rotary compressor, and reliable results have been obtained.

Effects of CNTs waviness and aspect ratio on vibrational response of FG-sector plate

  • Tahouneh, Vahid
    • Steel and Composite Structures
    • /
    • 제25권6호
    • /
    • pp.649-661
    • /
    • 2017
  • This paper is motivated by the lack of studies in the technical literature concerning to the influence of carbon nanotubes (CNTs) waviness and aspect ratio on the vibrational behavior of functionally graded nanocomposite annular sector plates resting on two-parameter elastic foundations. The carbon nanotube-reinforced (CNTR) plate has smooth variation of CNT fraction based on the power-law distribution in the thickness direction, and the material properties are also estimated by the extended rule of mixture. In this study, the classical theory concerning the mechanical efficiency of a matrix embedding finite length fibers has been modified by introducing the tube-to-tube random contact, which explicitly accounts for the progressive reduction of the tubes' effective aspect ratio as the filler content increases. Parametric studies are carried out to highlight the influence of CNTs volume fraction, waviness and aspect ratio, boundary conditions and elastic foundation on vibrational behavior of FG-CNT thick sectorial plates. The study is carried out based on three-dimensional theory of elasticity and in contrary to two-dimensional theories, such as classical, the first- and the higher-order shear deformation plate theories, this approach does not neglect transverse normal deformations. The annular sector plate is assumed to be simply supported in the radial edges while any arbitrary boundary conditions are applied to the other two circular edges including simply supported, clamped and free. For an overall comprehension on 3-D vibration of annular sector plates, some mode shape contour plots are reported in this research work.

Free vibrational behavior of perfect and imperfect multi-directional FG plates and curved structures

  • Pankaj S. Ghatage;P. Edwin Sudhagar;Vishesh R. Kar
    • Geomechanics and Engineering
    • /
    • 제35권4호
    • /
    • pp.367-383
    • /
    • 2023
  • The present paper examines the natural frequency responses of the bi-directional (nx-ny, ny-nz and nz-nx) and multidirectional (nx-ny-nz) functionally graded (FG) plate and curved structures with and without porosity. The even and uneven kind of porosity pattern are considered to observe the influence of porosity type and porosity index. The numerical findings have been obtained using a higher order shear deformation theory (HSDT) based isometric finite element (FE) approach generated in a MATLAB platform. According to the convergence and validation investigation, the proposed HSDT based FE model is adequate to predict free vibrational responses of multidirectional porous FG plates and curved structures. Further a parametric analysis is carried out by taking various design parameters into account. The free vibrational behavior of bidirectional (2D) and multidirectional (3D) perfect-imperfect FGM structure is examined against various power law index, support conditions, aspect, and thickness ratio, and for the curvature of curved structures. The results indicate that the maximum non-dimensional fundamental frequency (NFF) value is observed in perfect FGM plates and curved structures compared to porous FGM plates and curved structures and it is maximum for FGM plates and curved structures with uneven kind of porosity than even porosity.

분자동역학 시뮬레이션을 이용한 이팔면체 점토광물 수산기 연구 (A Molecular Dynamics Simulation Study of Hydroxyls in Dioctahedral Phyllosilicates)

  • 손상보;권기덕
    • 한국광물학회지
    • /
    • 제29권4호
    • /
    • pp.209-220
    • /
    • 2016
  • 점토광물은 대기부터 지하수에 이르는 크리티컬존(critical zone) 영역에서 금속과 탄소 순환을 결정짓는 역할을 한다. 계산광물학 연구방법 중에 하나인 분자동역학(molecular dynamics) 시뮬레이션은 지구물질을 원자단위로 계산하기 때문에, 점토광물의 물리화학적 현상들에 대해 원자수준의 자세한 정보를 제공할 수 있다. 이번 연구에서는 clayFF 힘 장(force field)을 사용한 분자동역학 시뮬레이션을 이팔면체 점토광물인 깁사이트(gibbsite, $Al(OH)_3$), 카올리나이트(kaolinite, $Al_2Si_2O_5(OH)_4$), 파이로필라이트(pyrophyllite, $Al_2Si_4O_{10}(OH)_2$)에 적용하여 300 K, 1기압조건에서 각 광물이 가지는 격자상수와 원자간 거리를 계산하고 실험결과와 비교하였다. 더불어 수산기의 방향성 및 수소결합의 양상 그리고 파워스펙트럼(power spectrum)을 추가적으로 계산하였다. 계산 결과, 격자상수는 기존의 실험결과와 약 0.1~3.7% 미만의 오차율을 보였으며, 원자간 거리는 실험결과와 약 5% 미만의 차이를 가졌다. 깁사이트나 카올리나이트의 팔면체층 표면에 존재하는 수산기가 가지는 신축진동파수(stretching vibrational wavenumber)는 실험값 보다 약 $200-300cm^{-1}$ 높게 계산되었지만, 팔면체층 표면에 존재하는 수산기들의 상대적 크기의 경향은 기존 실험 결과와 일치하였다. 팔면체층 표면의 수산기가 (001)면과 이루는 각도도 기존 실험결과와 상당부분 일치한 반면에 내부 수산기의 경우는 다소 차이를 보였다. ClayFF를 사용한 분자동역학 시뮬레이션 연구 방법은 이팔면체 점토광물 표면 내(층간) 금속이온 흡착에 대한 수산기의 역할을 규명하는데 유용한 연구방법이 될 수 있음을 시사한다.

동일 평면상에서 연성된 평판구조물 진동의 파워흐름해석 (Vibration Power Flow Analysis of Coupled co-planar Plate Structures)

  • 박도현;홍석윤;길현권
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1998년도 춘계학술대회논문집; 용평리조트 타워콘도, 21-22 May 1998
    • /
    • pp.311-318
    • /
    • 1998
  • In this paper, the power flow analysis(PFA) method is applied to the prediction of the vibrational energy density and intensity of coupled co-planar plates. To cover the energy transmission and reflection at the joint of the plates, the wave transmission approach is introduced with the assumption that all the incident waves are normal to the joint. By changing the frequency ranges and internal loss factors, we have obtained the PFA results, and compared them with the analytical exact solutions.

  • PDF