• 제목/요약/키워드: Vibration-Based

검색결과 5,263건 처리시간 0.031초

NEAR-INFRARED STUDIES ON STRUCTURE-PROPERTIES RELATIONSHIP IN HIGH DENSITY AND LOW DENSITY POLYETHYLENE

  • Sato, Harumi;Simoyama, Masahiko;Kamiya, Taeko;Amari, Trou;Sasic, Slobodan;Ninomiya, Toshio;Siesler, Heinz-W.;Ozaki, Yukihiro
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1281-1281
    • /
    • 2001
  • Near-infrared (NIR) spectra have bean measured for high-density (HDPE), linear low-density (LLDPE), and low-density (LDPE) polyethylene in pellet or thin films. The obtained spectra have been analyzed by conventional spectroscopic analysis methods and chemometrics. By using the second derivative, principal component analysis (PCA), and two-dimensional (2D) correlation analysis, we could separate many overlapped bands in the NIR. It was found that the intensities of some bands are sensitive to density and crystallinity of PE. This may be the first time that such bands in the NIR region have ever been discussed. Correlations of such marker bands among the NIR spectra have also been investigated. This sort of investigation is very important not only for further understanding of vibration spectra of various of PE but also for quality control of PE by vibrational spectroscopy. Figure 1 (a) and (b) shows a NIR reflectance spectrum of one of the LLDPE samples and that of PE, respectively. Figure 2 shows a PC weight loadings plot of factor 1 for a score plot of PCA for the 16 kinds of LLDPE and PE based upon their 51 NIR spectra in the 1100-1900 nm region. The PC loadings plot separates the bands due to the $CH_3$ groups and those arising form the $CH_2$ groups, allowing one to make band assignments. The 2D correlation analysis is also powerful in band enhancement, and the band assignments based upon PCA are in good agreement with those by the 2D correlation analysis.(Figure omitted). We have made a calibration model, which predicts the density of LLDPE by use of partial least square (PLS) regression. From the loadings plot of regression coefficients for the model , we suggest that the band at 1542, 1728, and 1764 nm very sensitive to the changes in density and crystalinity.

  • PDF

기계식(機械式) 회전(回轉)레이크를 이용(利用)한 생활계(生活界) 폐기물(廢棄物) 필름류(類) 선별장치(選別裝置) 개발(開發)에 관(關)한 연구(硏究) (Development of Separation System with Rotating Rakes for Recovery of Film-based Plastics)

  • 이병선;나경덕;한상국;최우진;박은규
    • 자원리싸이클링
    • /
    • 제19권3호
    • /
    • pp.24-32
    • /
    • 2010
  • 본 연구에서는 생활폐기물 전처리 시설 및 재활용 선별시설로 반입되는 필름류를 선별하기 위한 기계식 회전레이크를 개발하였으며, 성능평가 및 환경적합성 검토를 통하여 현장 적용 가능성 평가를 수행하였다. 실험결과 처리용량은 벨트컨베이어속도 38.5 m/min, 레이크 회전속도 26.0 rpm(1,2차 레이크 개수는 각각 39개, 52개, 3차 브러쉬 48개)에서 5.3 ton/hr로 설계용량인 5.0 ton/hr를 만족하였으며, 레이크 회전속도 28.0 rpm에서 필름류 회수율은 92.60%, 순도 96.50%로 매우 높게 나타났다. 본 장치에 대한 소음, 진동 및 비산먼지 농도 등에 대한 환경성 평가 결과, 환경오염법적배출허용 기준치를 모두 만족하는 것으로 조사되었다. 또한, 선별된 필름류를 대상으로 고형연료(RPF; Refuse Plastic Fuel) 제조를 통한 재활용 가능성을 평가한 결과, 발열량 약 9,740.3 kg/kcal, 염소함량 약 0.18%로 고형연료 품질기준 1등급을 만족하였다. 따라서 필름류 선별장치를 재활용 선별시설에 적용할 경우 작업량 증가 및 작업환경의 개선이 가능하고, 필름류 제거를 통한 자동화선별장치의 선별효율을 개선 할 수 있을 것으로 사료된다. 또한, 선별된 필름류를 고형연료로 제조하면 화석연료의 대체 에너지원으로서 사용 가능할 것으로 사료된다.

칼만필터를 적용한 UWB 센서기반 제조업 조립공정작업의 실시간 위치추적 시스템 개발 (Development of a Real-Time Position Tracking System for a Manufacturing Process Based on a UWB Sensor Using a Kalman Filter)

  • 정승현;최득성
    • 한국산학기술학회논문지
    • /
    • 제21권2호
    • /
    • pp.627-633
    • /
    • 2020
  • 일반적인 기계나 자동차 등의 제조업 조립공정은 공정별 흐름에 근접센서, 바코더, RFID, ZigBee, Bluetooth, 무선 센서 네트워크 등의 유무선 정보 수집 장치를 활용하여 실시간으로 공정 진행 정보를 네트워크를 통하여 상위의 제조 실행 시스템 MES(Manufacturing Execution System) 서버로 수집하는 방식으로서 공정의 흐름을 파악하고 생산량을 점검하기에 적합하나 개별 작업자의 해당 작업장 내에서의 작업 누락이나 동선 파악을 위한 실시간 위치 추적은 어려운 실정이다. 이를 극복하기 위하여, 작업자 공구의 실시간 위치 추적시스템 도입을 통해 공구의 위치 및 궤적을 실시간으로 분석하여 작업자에게 일관된 작업 순서를 지시하고 작업의 누락 및 가감을 체크한다면, 비숙련공이나 실수에 의해서 조립공정에서 발생할 수 있는 조립불량을 작업자에게 실시간으로 알려주거나 사전에 차단하여 생산성 및 품질향상을 이룰 수 있다. 이를 위하여, 전동공구의 기계적인 진동 및 무선통신 노이즈를 제거하고 측정신호의 정밀도 향상을 위하여 칼만필터를 적용한 UWB(Ultra Wide Band) 삼변측량 기반의 실시간 공구 위치 추적 센서시스템을 개발하였고 이동평균필터에 비해 약 21%의 무선측정 성능개선을 통하여 그 효용성을 증명하였다.

고속철도 터널내 압력파 측정과 공기압 해석모델에 대한 기초연구 (A comparative study of field measurements of the pressure wave with analytical aerodynamic model for the high speed train in tunnels)

  • 김효규;최판규;홍유정;유지오
    • 한국터널지하공간학회 논문집
    • /
    • 제17권3호
    • /
    • pp.319-332
    • /
    • 2015
  • 열차가 고속으로 터널내를 진입할 때 열차의 피스톤 작용에 의해 형성되는 압력파는 터널내를 진행하고, 출구에 도달한 압축파는 터널 출구면의 개구단 조건에 따라 팽창파로 터널입구로 다시 전파된다. 이에 따른 터널내 주행열차와의 간섭현상으로 인해 차량내 승객은 심한 압력변동을 느끼게 되며, 이러한 압력파는 열차의 설계와 운행에 영향을 미치고, 에너지 손실과 소음, 진동, 승객의 이명현상의 원인이 된다. 본 연구에서는 열차가 고속으로 터널내부를 진입시 나타나는 터널내 압력파의 전파특성과 열차의 기밀도에 따른 객실내로 침투하는 압력 변화량을 현장 실험내용과 비교분석을 수행하였다. 또한, 압축성 1-D 모델(MOC)의 적용 가능성을 살펴보기 위해 ThermoTun 프로그램과의 비교연구를 수행하였고, Baron의 압축성 1-D 수치모델에 기초한 지배방정식 해석의 적정성을 검토하기 위해 비교연구도 병행하였다.

수정 라플라시안 및 고유주파수를 이용한 보 구조물의 결함탐지기법 (Fault Detection Method for Beam Structure Using Modified Laplacian and Natural Frequencies)

  • 이종원
    • 한국산학기술학회논문지
    • /
    • 제19권5호
    • /
    • pp.611-617
    • /
    • 2018
  • 대형구조물의 효과적인 구조 안전성 확보를 위해서는 결함탐지기술을 포함한 건전성 모니터링의 적용이 필요하다. 본 연구에서는 보 구조물에 발생하는 균열위치와 균열크기를 추정하기 위하여 다음과 같은 2단계의 균열추정방법을 제안한다. 우선, 보 구조물의 분포 국부 변형률 계측결과를 이용하여 변형률 모드형상을 구하고, 이에 대한 수정 라플라시안(Laplacian) 연산을 통하여 균열발생 영역을 추정한다. 이후, 가속도 측정을 통하여 구한 고유주파수와 신경망기법을 이용하여, 미리 추정된 균열발생 영역을 대상으로 균열위치와 균열크기를 추정한다. 이때, 신경망을 훈련시키기 위하여, 에너지법에 의해 유도된 균열보의 등가휨강성을 이용하여 균열보의 고유주파수를 해석적으로 구한다. 기법을 검증하기 위하여 알루미늄 캔틸레버 보에 대한 손상실험을 수행하였다. 인위적으로 실험체에 균열을 가한 후 자유진동실험을 수행하여 동적 변형률과 가속도를 계측하고 이를 이용하여 변형률 모드형상과 고유주파수를 구하였다. 변형률 모드형상에 대한 수정 라플라시안 연산을 통하여 균열발생 영역을 추정하고, 고유주파수와 신경망기법을 이용하여, 미리 추정된 균열발생 영역에 대하여 균열위치와 균열크기를 판정하였다. 3가지 손상경우에 대한 균열발생 영역의 추정결과는 실제 영역과 잘 일치하였으며, 균열위치와 균열크기 추정결과의 정확성을 상당히 향상시킬 수 있었다. 제안된 기법은 장대구조물에 대한 구조물 건전성 모니터링에 효과적으로 활용될 수 있을 것으로 판단된다.

수종의 임플랜트 시스템의 나사풀림에 관한 연구 (Screw Loosening of Various Implant Systems)

  • 안진수;조인호;임주환;임헌송
    • 구강회복응용과학지
    • /
    • 제18권2호
    • /
    • pp.81-91
    • /
    • 2002
  • Dental implant systems have shown many post-surgical problems and One of the most frequent problem is screw loosening. To reduce screw loosening, a number of methods have been tried and recently fundamental modification of fixture-abutment connection structure was developed and used the most frequently. Former implant system structure, such as Br${\aa}$nemark, had external hex with the height of 0.7 mm and later, fixture with external hex of 1.0 mm height and internal hex structure were developed. In addition, the method of morse taper application was introduced to reduce screw loosening. In this study, the level of screw loosening of each implant systems was compared based on the vibration loosening measurement of abutment screw of each implant systems. Analysis of measured value was performed using 3 kinds of methods, (i) Percentage of average of initial 3 times loosening-torque value(initial loosening value) to tightening-torque of 30 Ncm, (ii) Percentage of loosening-torque value after 200 N strength loaded(experimental value) to initial loosening value and (iii) Percentage of experimental value to 30 Ncm of tightening-torque. Each result of analyses shows the value of initial loosening, loosening by repetitive load and final loosening level. The results of this study were as follows. (1) Percentage of initial loosening value to tightening-torque was increased in order of 0.7 mm external hex, 1.0 mm external hex, internal hex and internal taper and all values between each groups showed statistical significance (p<0.05). (2) Percentage of experimental value to initial loosening value was increased in order of internal hex, 0.7 mm external hex, 1.0 mm external hex and internal taper. Value of internal taper showed significant difference with that of 0.7 mm external hex and internal hex (p<0.05). (3) Percentage of experimental value to tightening torque was increased in order of 0.7 mm external hex, 1.0 mm external hex, internal hex and internal taper. Values of all groups showed statistical significance (p<0.05) except between the groups of 1.0 mm external hex and internal hex. Based on those results, there was no significant difference of loosening-torque by repetitive loading except internal taper. It is supposed that implant system with high resistant capability against initial loosening could be recommended for clinical use. In addition, in case of single implant restoration, 1.0 mm external hex or internal hex could be recommended rather than 0.7 mm external hex, and the use of internal taper would be the most useful way to reduce screw loosening.

초고층건물의 성능평가를 위한 응답의존 시스템판별 및 모델향상 (Output-Only System Identification and Model Updating for Performance Evaluation of Tall Buildings)

  • 조순호
    • 한국지진공학회논문집
    • /
    • 제12권4호
    • /
    • pp.19-33
    • /
    • 2008
  • 구조물에 고유한 진동수,모드형태 및 감쇠비 등과 같은 동적성능치를 추출하기 위하여 25층 및 42층 건물에 대하여 자연진동에 의한 동적계측실험을 수행하였다. 고려된 건물은 주요 횡하중 지지기구로서 코아벽체 혹은 전단벽체가 추가된 철근콘크리트건물이며, 입면 혹은 평면상으로 골조가 혼합된 구조형식을 나타낸다. 특히, 25층 건물은 측면에 위치한 코아벽체 이외에 상부로부터 내려오는 전단벽 구조가 4층 바닥이하에서 골조형식으로 전환되는 복잡한 구조이다. 이와 같은 이유 및 건물 주방향의 유사한 강성배치로 매우 근접하고 혼합된 모드형태가 예상되어 시스템판별 시 어려움이 예상된다. 현재까지 개발된 다양한 시스템판별법을 대상건물의 자연진동 실측기록에 적용하여 모달계수를 유도하였으며, 그 결과를 비교 분석하였다. 3개의 주파수영역 및 4개의 시간영역에 근거한 응답의존 시스템판별법이 고려되었다. 서로 다른 시스템판별법에 의하여 추출된 고유진동수 및 감쇠비는 대체로 상당한 일치를 보였으나, 모드형태는 사용된 방법에 따라 정도가 다르게 불일치를 나타냈다. 실험으로부터 추출한 성능치와 초기 유한요소해석 값을 비교해 본 결과 대상건물 모두 적어도 저차 3개의 고유진동수에서 2배 정도의 차이를 나타냈다. 실험과 해석결과의 일치를 위하여 몇몇 수동모델향상이 시도되었으며, 허용할 만한 결과를 획득하였다. 사용된 시스템판별법에 대하여 각자의 장, 단점에 대하여 기술하였으며, 본 연구와 같은 실제 대형구조물에 대하여 자동모델향상기법을 적용할 시 예상되는 문제점에 대하여 토의하였다.

STSAT-3 Main Payload, MIRIS Flight Model Developments

  • 한원용;이대희;박영식;정웅섭;이창희;문봉근;박성준;차상목;남욱원;박장현;이덕행;가능현;선광일;양순철;박종오;이승우;이형목
    • 천문학회보
    • /
    • 제35권1호
    • /
    • pp.40.1-40.1
    • /
    • 2010
  • The Main payload of the STSAT-3 (Korea Science & Technology Satellite-3), MIRIS (Multipurpose Infra-Red Imaging System) has been developed for last 3 years by KASI, and its Flight Model (FM) is now being developed as the final stage. All optical lenses and the opto-mechanical components of the FM have been completely fabricated with slight modifications that have been made to some components based on the Engineering Qualification Model (EQM) performances. The components of the telescope have been assembled and the test results show its optical performances are acceptable for required specifications in visual wavelength (@633 nm) at room temperature. The ensuing focal plane integration and focus test will be made soon using the vacuum chamber. The MIRIS mechanical structure of the EQM has been modified to develop FM according to the performance and environment test results. The filter-wheel module in the cryostat was newly designed with Finite Element Analysis (FEM) in order to compensate for the vibration stress in the launching conditions. Surface finishing of all components were also modified to implement the thermal model for the passive cooling technique. The FM electronics design has been completed for final fabrication process. Some minor modifications of the electronics boards were made based on EQM test performances. The ground calibration tests of MIRIS FM will be made with the science grade Teledyne PICNIC IR-array.

  • PDF

캡슐트레인 주행 동특성 분석을 위한 축소 시험장치의 개발 (Development of the Small Scale Testbed for Running Dynamic Characteristics Analysis of the Capsule Train)

  • 이진호;유원희;이관섭
    • 한국산학기술학회논문지
    • /
    • 제21권9호
    • /
    • pp.643-651
    • /
    • 2020
  • 공기 저항이 적은 아진공 상태의 튜브 안을 주행함으로써 초고속주행이 가능한 캡슐트레인은 부상 공극이 커서 인프라 건설 비용 절감에 유리한 초전도 유도 반발식 부상을 채택하고 있다. 초전도 유도 반발식 부상은 부상 공극을 크게 할 수 있고, 별도의 공극 제어가 필요 없는 장점이 있는 반면, 공극 변동량이 크고 부상력에 댐핑 특성이 작기 때문에 차량의 주행 안정성 및 승차감이 악화 될 수 있다. 이러한 단점을 극복하기 위해서는 차량의 주행 동특성에 기반한 주행안정화장치를 설계하고 적용하여야 한다. 본 연구에서는 캡슐트레인의 동특성을 모사하고 주행안정화장치의 성능을 사전에 검토할 수 있는 1/10 스케일의 축소형 시험장치를 개발하였다. 시험장치는 대차의 모션을 구현할 수 있는 6 자유도 스튜어트 플랫폼, 주행안정화장치가 적용된 2차 현가장치 및 차체로 구성되어 있다. Jaschinski가 제안한 동특성 상사 법칙에 따라 축소 시험장치를 제작하였고, 가이드웨이 불규칙도와 부상 강성이 반영된 대차 모션 구현 알고리즘을 적용하였다. 제작된 시험장치를 이용한 실험을 통해 얻어진 결과와 수치해석 결과와의 비교를 통해 시험장치의 성능을 검토하였다.

기지 패턴의 카메라 Calibration에 기반한 물체의 깊이 데이터 추출에 관한 연구 (A Study on Depth Data Extraction for Object Based on Camera Calibration of Known Patterns)

  • 조현우;서경호;김태효
    • 융합신호처리학회 학술대회논문집
    • /
    • 한국신호처리시스템학회 2001년도 하계 학술대회 논문집(KISPS SUMMER CONFERENCE 2001
    • /
    • pp.173-176
    • /
    • 2001
  • 본 논문에서는, 기지패턴에 대한 카메라 Calibration을 이용하여 물체의 깊이정보를 추출하기 위한 새로운 계측시스템을 구축하였다. 3차원 실세계좌표와 2차원 영상좌표계의 관계를 해석하였고, 이로부터 카메라의 Calibration 알고리즘을 확립하여 카메라의 내부 변수와 외부 변수를 구하였다. 3차원 공간의 계측면을 평면으로 가정하고 평면의 방정식과 좌표계 변환 방정식으로부터 뉴-턴 랩슨법을 이용하여 최소 값에 대응하는 근사치로 깊이정보를 추출하고 실시간 처리를 위해 이를 Look-up 테이블에 저장하였다. 실험시스템에서 슬릿 레이저 투광기를 물체에 조사하고 이로부터 x-z평면의 2D 영상을 획득하였다. 이 과정을 물체를 이동시키면서 연속으로 획득하여 3D 영상 정보를 얻었다. 3D 형상을 모니터에 표시하기 위해 OpenGL을 이용하여 계측된 3D 형상을 얻을 수 있었다. 계측 결과, 분해능에서 약 1%의 오차가 발생하였으며, 이는 선형 모-터의 진동성분과 계측시스템의 광학적 오차에 기인된 것이라 판단되었다. 이를 개선하기 위해 기구적 시스템의 안정과 정밀용 카메라를 사용하므로 해결할 수 있으리라 판단된다.

  • PDF