• 제목/요약/키워드: Vibration serviceability

검색결과 184건 처리시간 0.028초

철골조 고층 병원건물의 진동예측을 위한 동적특성 및 설계인자에 관한 연구 (The study on the dynamic characteristics of steel structure system for vibration estimation in hospital building)

  • 장강석;김영찬;안상경;나운
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.458-461
    • /
    • 2008
  • The primary objective of this study is to provide simple analytical tools to estimate dynamic characteristics of steel framed floor system in hospital building for vibration serviceability due to human activities, bogie, medical equipment. and so on. In order to evaluate the dynamic characteristics and vibration levels according to steel framed floor system, we had executed impact test and measurement on steel structure floor system in various hospital buildings. But perhaps most importantly, how to make the most of deduced design factor for design of hospital building. therefore we presented the access method such as the three-dimensional F.E. numerical analysis on the basis of the design drawing, and the properties of all floors for estimation of vibration level in hospital building.

  • PDF

프리캐스트 콘크리트 바닥판의 수직진동 허용치 평가 (Performance Evaluation of Vertical Vibration of Precast Concrete Slabs)

  • 허석재;이상현;조승호;정란;김성배;박성순
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.662-667
    • /
    • 2009
  • In this study, the serviceability of Waffle shaped(WAS) and Double-Tee(DT) precast concrete slabs was evaluated and compared based on the vertical acceleration magnitude induced by walking and heel drop loads. Tests were conducted for practical building structures (a shopping mall in Hanam) of which floor systems used WAS and DT slabs. Natural frequencies of the slabs were similar to those obtained by using analytical models. The measured acceleration level was evaluated by vertical floor acceleration criteria presented by ISO-2631, AIJ(1991, Japan), and a previous study regarding floor vibration limit. Test results showed that both WAS and DT slabs satisfied all the criteria and the maximum acceleration level of WAS slabs was lower than that of DT slabs.

  • PDF

휴대폰 애플리케이션을 통한 초대형 구조물의 동적특성 분석 (Dynamic Characterization of Large-scale Structures through Mobile-phone Application)

  • 정영석;윤성원
    • 한국공간구조학회논문집
    • /
    • 제15권4호
    • /
    • pp.99-105
    • /
    • 2015
  • The serviceability design of the high-rise building is affected by the wind response vibration such as the acceleration, at this time it is important to calculate the natural frequency correctly. Since the suggestion equation of the natural frequency being used in the design phase is not the regression equation obtained from the vibration measurement of the high-rise building, the verification to use for the serviceability design of the high-rise building is necessary. This thesis conducted an ambient vibration measuring on the high-rise building through the mobile-phone application to calculate the natural frequency and suggested a natural frequency approximate expression following the building's height, and compared with the domestic/foreign standard and the result of the eigen-value analysis.

VSimulators: A New UK-based Immersive Experimental Facility for Studying Occupant Response to Wind-induced Motion of Tall Buildings

  • Antony Darby;James Brownjohn;Erfan Shahabpoor;Kaveh Heshmati
    • 국제초고층학회논문집
    • /
    • 제11권4호
    • /
    • pp.347-362
    • /
    • 2022
  • Current vibration serviceability assessment criteria for wind-induced vibrations in tall buildings are based largely on human 'perception' thresholds which are shown not to be directly translatable to human 'acceptability' of vibrations. There is also a considerable debate about both the metrics and criteria for vibration acceptability, such as frequency of occurrence or peak vs mean vibration, and how these might vary with the nature of the vibration. Furthermore, the design criteria are necessarily simplified for ease of application so cannot account for a range of environmental, situational and human factors that may enhance or diminish the impact of vibrations on serviceability. The dual-site VSimulators facility was created specifically to provide an experimental platform to address gaps in understanding of human response to building vibration. This paper considers how VSimulators can be used to inform general design guidance and support design of specific buildings for habitability, in terms of vibration, which allow engineers and clients to make informed decisions with regard to sustainable design, in terms of energy and financial cost. This paper first provides a brief overview of current vibration serviceability assessment guidelines, and the current understanding and limitations of occupants' acceptability of wind-induced motion in tall buildings. It then describes how the dual-site VSimulators facility at the Universities of Bath and Exeter can be used to assess the effects of motion and environment on human comfort, wellbeing and productivity with examples of how the facility capabilities have been used to provide new, human experience based experimental research approaches.

면진장치 장착 스카이 브릿지의 사용성 평가 (Serviceability Evaluation of Sky Bridge With Isolation Device)

  • 김기철;김현수;김수근
    • 한국공간구조학회논문집
    • /
    • 제17권2호
    • /
    • pp.71-77
    • /
    • 2017
  • In this study, the boundary non-linear analysis of the sky bridge subjected to walking load and running load is performed. The sky bridge is installed in the mid-story between two buildings and the walking load and running load induced by pedestrians are measured by load cell. LRB is modeled as a non-linear hysteresis model to accurately represent the behavior of LRB. For the serviceability evaluation of sky bridge, the acceleration responses of sky bridge are analyzed based on ISO 2631-2 and the velocity response are analyzed based on standards Bachmann &Amann. In serviceability evaluation of this sky bridge, the pedestrian can not perceive the vibration except for resonance running loads consequently. Therefore, it is concluded that this sky bridge haven't problem in the serviceability.

실험적 방법에 의한 콘크리트 사장교의 보행자 중심 진동사용성 평가 (Vibration Serviceability Evaluation for Pedestrian of Concrete Cable-stayed Bridge by Experimental Method)

  • 강성후;최봉현;박선준
    • 한국방재학회 논문집
    • /
    • 제11권2호
    • /
    • pp.59-66
    • /
    • 2011
  • 본 연구에서는 콘크리트 사장교를 대상으로 차량주행속도와 교면아스팔트의 포장 상태, 차량중량 등을 실험변수로 하여 차량이 교량을 주행할 때 교면(보도)진동이 보행자에게 미치는 진동사용성 평가 방법에 대해 연구하고 그 결과로부터 진동사용성 여부를 평가하였다. 특히, 실험변수 가운데 교면포장 상태를 BMS기준에 의해 A와 C등급으로 구분하였다. 여기에는 진동을 발생시키는 에너지원을 "환산중량"으로 정의하고 차량주행 속도와 차량중량의 자승근을 곱한 형태로 사용하였다. 환산중량 228.0~1161.9 km/h kN 범위 내의 동일한 실험 조건에서 얻어진 교면포장 상태 A등급의 경우에 대한 C등급 경우의 진동가속도 응답 비율은 1.23~1.43으로 분석되어 교면포장 상태가 진동가속도 응답을 결정짓는데 큰 영향을 미치고 있음을 확인 할 수 있었다. 연구대상 교량의 교면 진동가속도 응답을 추정할 수 있는 진동추정식을 신뢰도 50%, 90%, 95%로 구분하여 제시하였으며, 실험 교량에서 교면 포장 A등급과 C등급의 경우 각각 전체응답의 30%, 40%가 레벨 C(강하게 감지)범위, 70%, 60%가 레벨 D(명확하게 감지) 범위에 있는 것으로 나타났다.

수직진동에 대한 사용성을 고려한 경계조건에 따른 2방향 슬래브 최소두께 제안 (Proposing the Thickness of 2-Way Slab Satisfying Floor Vibration Criteria for Several Boundary Condition)

  • 김동현;이민정;한상환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.199-202
    • /
    • 2005
  • KCI 2003 provides minimum thickness of slab that satisfies serviceability to static displacement. Previous study (Han, et al. 2003) showed the several slabs that designed according to minimum thickness criteria had floor vibration problem. In this study, evaluate the floor vibration serviceability of KCI 2003 minimum thickness requirements for 2-way flat plate and propose the minimum thicknesses of 2-way slabs that satisfy floor vibration criteria according to several boundary condition. For this purpose, one degree of freedom model is used and Monte Carlo simulation is performed.

  • PDF

주기 조절을 이용한 고층 건물의 풍응답 조절 설계 (Wind Induced Vibration Design for High-rise buildings through Control of Natural Period)

  • 김지은;차성희;서지현;박효선
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2004년도 가을 학술발표회 논문집
    • /
    • pp.43-51
    • /
    • 2004
  • As the slenderness ratio of a high-rise building increases, the lateral load resisting system for the building is more often determined by serviceability design criteria. In serviceability design, the maximum drift and the level of vibration are controlled not to exceed the design criteria. Even though many drift method have been developed in various forms, no practical design method for wind induced vibration has been developed so far. Structural engineers rely upon heuristic or experience in designing wind induced vibration. Development of practical design method for wind induced vibration is required. Generally, wind induced acceleration responses are depending on several variables such as the weight density of a building, damping ratio, the natural period, and etc.. All parameters except the natural period or frequency are usually out of reach for structural engineers, then the wind acceleration response may be proportioned to the natural period. Therefore, in this paper, a wind induced vibration design method based on frequency control technique for high-rise is proposed. The method is applied to vibration design of a 25-story office building for performance evaluation.

  • PDF

On methods for extending a single footfall trace into a continuous force curve for floor vibration serviceability analysis

  • Chen, Jun;Peng, Yixin;Ye, Ting
    • Structural Engineering and Mechanics
    • /
    • 제46권2호
    • /
    • pp.179-196
    • /
    • 2013
  • An experimentally measured single footfall trace (SFT) from a walking subject needs to be extended into a continuous force curve, which can then be used as load for floor vibration serviceability assessment, or on which further analysis like discrete Fourier transform can be conducted. This paper investigates the accuracy, applicability and parametrical sensitivity of four extension methods, Methods I to IV, which extends the SFT into a continuous time history by the walking step rate, stride time, double support proportion and the double support time, respectively. Performance of the four methods was assessed by comparing their results with the experimentally obtained reference footfall traces in the time and frequency domain, and by comparing the vibrational response of a concrete slab subjected to the extended traces to that of reference traces. The effect of the extension parameter on each method was also explored through parametrical analysis. This study finds that, in general, Method I and II perform better than Method III and IV, and all of the four methods are sensitive to their extension parameter. When reliable information of walking rate or gait period is available in the test, Methods I or II is a better choice. Otherwise, Method III, with the suggested extension parameter of double support time proportion, is recommended.