• 제목/요약/키워드: Vibration isolator

검색결과 209건 처리시간 0.033초

MR 댐퍼의 비선형해석을 이용한 반능동형 제진대에 관한 연구 (A Study on Semi-active Vibration Isolation Table using a Nonlinear Analysis of the MR Damper)

  • 김도영;전종균;권영철
    • 한국소음진동공학회논문집
    • /
    • 제24권11호
    • /
    • pp.861-867
    • /
    • 2014
  • In this study, a semi-active isolator was constructed from applying a MR damper that used the MR fluid to an isolator. The parameter identification was also performed to determine the characteristics of this semi-active isolator during which the least squares method and the auxiliary variable method were applied to produce a value closest to the true value. In addition, the MR damper's nonlinear damping force was closely analyzed to greatly reduce the range of error. Based on this analysis, it was discovered that the parameter tended to increase with more electric current. Such analysis of the dynamic properties of semi-active isolator proved that constructing an isolator that provides a more stable operation could be achieved.

Experimental investigation on the effectiveness of under-foundation isolator against train-induced vibrations considering foundation type

  • Ehsan Haghighi;Javad Sadeghi;Morteza Esmaeili
    • Structural Engineering and Mechanics
    • /
    • 제89권2호
    • /
    • pp.121-133
    • /
    • 2024
  • In this paper, the performance of under-foundation isolators against generally annoying train-induced vibrations was examined experimentally. The effect of foundation type on the efficacy of such isolators was investigated for the first time. To this end, laboratory models including a soil container, soil, building with three types of foundation (i.e., single, strip, and mat), and isolator layer were employed. Through various dynamic tests, the effects of foundation type, isolation frequency, and the dominant frequency of train load on the isolator's performance were studied. The results demonstrated that the vibration level in the unisolated building with the strip and mat foundation was, respectively, 29 and 38% lower than in the building with the single foundation. However, the efficacy of the isolator in the building with the single foundation was, respectively, 21 and 40% higher than in the building with the strip and mat foundation. Furthermore, a lower isolation frequency and a higher excitation frequency resulted in greater isolator efficacy. The best vibration suppression occurred when the excitation frequency was close to the floor's natural frequency.

플로팅 슬래브궤도를 적용한 선하역사 구조물 진동해석 (Vibration Analysis of Station under Railway Lines with Floating Slab Track)

  • 장승엽;조호현;양신추
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.1719-1724
    • /
    • 2010
  • In the areas susceptible to vibration and noise induced by railway traffic such as downtown area and stations under railway lines, the vibration and the structure-borne noise can be solved by floating slab track system separating the entire track structure from its sub-structure using anti-vibration mat or springs. In other countries, the core technologies for vibration-proof design and vibration isolator - one of key components - have been developed and many installation experiences have been accumulated. However, in Korea, since the design technology of system and components are not yet developed, the foreign systems are being introduced without any adjustment. Thus, in this study, the vibration isolator has been developed and its performance are investigated by the dynamic analysis of a station structure under railways lines and the floating slab track system. For this purpose, the loads transferred from the vibration isolator of the floating slab track were evaluated by train running simulation considering vehicle-track interaction, and then the dynamic analysis of station structure subjected to these loads was performed. The dynamic analysis results show that the proposed floating slab track can reduce the vibration of structure by about 25dB compared with that in conventional ballast track without floating system.

  • PDF

고무의 전단 탄성을 이용한 방진마운트 개발 (Development of Shear Type Rubber Isolator)

  • 윤승원;이성춘
    • 한국정밀공학회지
    • /
    • 제15권10호
    • /
    • pp.58-64
    • /
    • 1998
  • Rubber isolator has many advantages compared with steel spring mount. Rubber has high internal damping and can be formed various shape depending on specific purpose. On the contrary, low modulus of elasticity of rubber results the instability of rubber isolator by buckling phenomenon. This paper presents the development of shear type rubber isolator for industrial application by using shear rigidity property of rubber. The static load-deflection characteristics of developed isolator has been analyzed by the FEM. Consequently, the static load testing and a measure of the effectiveness of a vibration isolator in terms of force transmissibility for developed isolator have been carried out.

  • PDF

시간지연 제어기법을 이용한 공압 제진대의 저주파 영역에서의 진동 절연 성능 향상 (Performance Enhancement of Pneumatic Vibration Isolator in Low Frequency by Time Delay Control)

  • 오기용;신윤호;이정훈;김광준
    • 한국소음진동공학회논문집
    • /
    • 제16권11호
    • /
    • pp.1100-1107
    • /
    • 2006
  • As environmental vibration requirements on precision equipment become more stringent, use of pneumatic isolators has become more popular and their performance is subsequently required to be further improved. Performance of passive pneumatic isolators is related to various design parameters in a complicated manner and, hence, is very limited especially in low frequency range by chamber volume. In this study, transmissibility behavior of the pneumatic isolators depending on frequency and dynamic amplitude are presented. Then, an active control technique, time delay control, which is adequate for a low frequency nonlinear system, is applied. A procedure of applying the time delay control law to a pneumatic isolator is presented and it's effectiveness in the transmissibility performance is shown. Comparison between passive and active pneumatic isolators is made based on simulation.

시간지연 제어기법을 이용한 공압 제진대의 저주파 영역에서의 진동 절연 성능 향상 (Performance Enhancement of Pneumatic Vibration Isolator in Low Frequency by Time Delay Control)

  • 오기용;신윤호;이정훈;김광준
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.837-843
    • /
    • 2006
  • As environmental vibration requirements on precision equipment become more stringent, use of pneumatic isolators has become more popular and their performance is subsequently required to be further improved. Performance of passive pneumatic isolators is related to various design parameters in a complicated manner and, hence, is very limited especially in low frequency range by chamber volume. In this study, transmissibility behavior of the pneumatic isolators depending on frequency and dynamic amplitude are presented. Then, an active control technique, time delay control, which is adequate for a low frequency nonlinear system, is applied. A procedure of applying the time delay control law to a pneumatic isolator is presented and it's effectiveness in the transmissibility performance is shown. Comparison between passive and active pneumatic isolators is made based on simulation.

  • PDF

Polyorganosiloxane 변성 말레화 EPDM/EPDM 방진고무의 제조와 그 특성 (Preparation and Properties of Polyorganosiloxane Modified Maleated EPDM/EPDM Rubber Vibration Isolator)

  • 강두환;김소미
    • 공업화학
    • /
    • 제21권5호
    • /
    • pp.581-585
    • /
    • 2010
  • 산업폐기물 중의 하나인 무기 금속화합물, Alnico를 1,3,5-trimethylcyclotrisilazane으로 표면 처리하여 충전제로 하고 EPDM에 maleic anhydride (MA)를 용융 중합법으로 그라프트시켜 제조한 말레화 EPDM과 ${\alpha},{\omega}$-bis(3-aminopropyl)polydimethylsiloxane을 공중합시켜 제조한 말레화 EPDM-polydimethylsiloxane공중합체(MEPDM-PDMS)와 EPDM 및 표면처리된 Alnico를 compounding하여 composite rubber를 제조하였다. EPDM/Alnico/MEPDM-PDMS 방진고무는 MEPDMPDMS와 EPDM을 중량비로 1 : 10으로 하고 또한 충전제의 함량을 EPDM에 대하여 25, 50 phrs로 그리고 개시제로 dicumyl peroxide (DCP)를 첨가하여 compounding시킨 다음 유압 고온 프레스로 가교시켜 제조하였다. 제조한 composite rubber의 열적특성을 측정한 결과 MEPDM-PDMS를 첨가하여 제조한 시료의 Tg가 EPDM만으로 제조한 고무보다 약간 낮은 $-33^{\circ}C$ 부근으로 나타났고 DMA의 측정결과 손실계수 tan ${\delta}$는 MEPDM-PDMS을 혼합한 경우가 더 크게 나타나는 것으로 보아 방진 특성이 우수함을 확인하였다.

다구찌 직교배열의 반응표면모델에 의한 흡차음재 소재 DB 구축 (Construction of Insulator and Isolator Database by Using Response Surface Model based on Taguchi's Orthogonal Array)

  • 이광기;김병훈;전인기;강경순;김옥빈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.619-624
    • /
    • 2000
  • Design of experiments based on Taguchi's orthogonal array is utilized for exploring the design space and for building response surface models of insulator and isolator database in order to facilitate the effective solution of multi-objective optimization commonly occurred in NVH problems. Response surface models, called engineering database of design space, provide an efficient means to rapidly model the trade-off among many conflicting NVH goals in automotive. In the design of insulator and isolator in automotive interior part, it is important not only to construct effective matrices of NVH but also to build up engineering database of current products. The experimental design especially based on orthogonal array and the nonlinear optimization algorithms are successfully used together to obtain the optimal design of insulator and isolator. The $2^{nd}$ order response surface models of absorption coefficient and insertion loss are constructed by using modified Taguchi's $L_{12}2^13^7$ orthogonal array and successfully used in optimal design of insulator and isolator.

  • PDF