• 제목/요약/키워드: Vibration Testing

검색결과 772건 처리시간 0.022초

가진 시험 방법을 활용한 자동차 도어 플레이트 모듈 슬램 내구 평가 (Evaluation on Slam Resistance of Door Plate Module Using Vibration Testing Method)

  • 김찬중;손태관
    • 한국소음진동공학회논문집
    • /
    • 제22권10호
    • /
    • pp.968-973
    • /
    • 2012
  • Slam testing is a mandatory testing process to evaluate the fatigue resistance of a door plate module before delivering it to car makers. This process is very hard job to complete it since the testing facilities are considerably expensive and the required testing time is relatively very long, i.e. more than eight days for a single specimen. In this paper, an accelerated testing method of a door plate module is proposed using vibration test equipment instead of the current one by exposing to the critical excitation of a door glass. Under the proposed excitation method, the similar testing result can be evaluated within less than two hours. The suitability of the proposed testing method was demonstrated by comparing failure modes of both the current testing method and the proposed one.

Spacecraft vibration testing: Benefits and potential issues

  • Kolaini, Ali R.;Tsuha, Walter;Fernandez, Juan P.
    • Advances in aircraft and spacecraft science
    • /
    • 제5권2호
    • /
    • pp.165-175
    • /
    • 2018
  • Jet Propulsion Laboratory has traditionally performed system level vibration testing of flight spacecraft. There have been many discussions in the aerospace community for more than a decade about spacecraft vibration testing benefits or lack thereof. The benefits and potential issues of fully assembled flight spacecraft vibration testing are discussed herein. The following specific topics are discussed: spacecraft screening test to uncover workmanship problems for launch dynamics environments, force- and moment-limited vibration testing, potential issues with structural frequency identification using base shake test data, and failures related to vibration shaker testing and ways to prevent them.

액체봉입형 Viscous 굴삭기 Cabin Mount 개발 (Development of Viscous Cabin Mount for Excavator)

  • 김원영;전범석;박외경;강하근
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1997년도 추계학술대회논문집; 한국과학기술회관; 6 Nov. 1997
    • /
    • pp.339-344
    • /
    • 1997
  • Samsung Ltd. has developed a new-type cab mount for specific use on construct ion machinery subjected to strong vibration and multi-directional impact force. These all make it possible to achieve an excellent damping effect over a wide frequency range against large amplitude vibration as well as excellent insulation against small-amplitude vibration. This new mount make lower vibration and noise levels while increasing riding comfort at the same time. Characteristics of Cab mount were optimized through computer simulation, advanced bench testing, ODS testing, and a real equipment offroad testing.

  • PDF

Ambient vibration testing and seismic performance of precast I beam bridges on a high-speed railway line

  • Toydemir, Burak;Kocak, Ali;Sevim, Baris;Zengin, Basak
    • Steel and Composite Structures
    • /
    • 제23권5호
    • /
    • pp.557-570
    • /
    • 2017
  • In this study, the seismic performance levels of four bridges are determined using finite element modeling based on ambient vibration testing. The study includes finite element modeling, analytical modal analyses, ambient vibration testing and earthquake analyses of the bridges. For the purpose, four prestressed precast I beam bridges that were constructed for the Ankara-Sivas high speed railway line are selected for analytical and experimental studies. In the study, firstly a literature review related to the dynamic behavior of bridges especially precast beam bridges is given and then the formulation part related to ambient vibration testing and structural performance according to Turkish Seismic Code (2007) is presented. Next, 3D finite element models of the bridge are described and modeled using LARSA 4D software, and analytical dynamic characteristics are obtained. Then ambient vibration testing conducted on the bridges under natural excitations and experimental natural frequencies are estimated. Lastly, time history analyses of the bridges under the 1999 Kocaeli, 1992 Erzincan, and 1999 Duzce Earthquakes are performed and seismic performance levels according to TSC2007 are determined. The results show that the damage on the bridges is all under the minimum damage limit which is in the minimum damage region under all three earthquakes.

Performance of Different Sensors for Monitoring of the Vibration Generated during Thermosonic Non-destructive Testing

  • Kang, Bu-Byoung
    • 비파괴검사학회지
    • /
    • 제31권2호
    • /
    • pp.111-117
    • /
    • 2011
  • Vibration monitoring is required for reliable thermosonic testing to decide whether sufficient vibration is achieved in each test for the detection of cracks. From a practical point of view, a cheaper and convenient monitoring method is better for the application to real tests. Therefore, the performance of different sensors for vibration monitoring was investigated and compared in this study to find a convenient and acceptable measurement method for thermosonics. Velocity measured by a laser vibrometer and strain provide an equivalent HI when measured at the same position. The microphone can provide a cheaper vibration monitoring device than the laser and the heating index calculated by a microphone signal shows similar characteristics to that calculated from velocity measured by the laser vibrometer. The microphone frequency response shows that it underestimates high frequency components but it is applicable to practical tests because it gives a conservative value of HI.

진동시험용 치구의 실험적 구조변경 설계 (Experimental Structural Dynamic Modification of Fixture for Vibration Testing)

  • 정의봉;오영세;김준엽
    • 소음진동
    • /
    • 제8권1호
    • /
    • pp.180-186
    • /
    • 1998
  • Vibration test fixture is used in random vibration control testing. The specified reference spectrum should be transmitted equally to the specimen attachment points on the fixture. In most practical cases, however, spectrum at each of specimen attachment points may be quite different from the specified reference spectrum because of the dynamic characteristics of vibration test fixture. This paper proposes the method of experimental dynamic modification of fixture system for vibration test so that the reference spectrum can be transmitted to the specimen attachment points without distortion. The stiffness of mounts of specimen and the thickness of fixture are considered as design variables. The frequency response functions of specimen used for input data are obtained from vibration testing, and the frequency response functions of fixture are obtained from finite element modeling. The sensitivities of frequency response functions at specimen attachment points to the mount stiffness are derived from synthesis method of transfer function. And the sensitivities to the thickness of fixture are also derived from finite element modeling. The presented method is verified by computer simulation and vibration testing.

  • PDF

점용접 표준시편에 대한 가속내구시험법의 적용 (Application of Accelerated Vibration Testing to Spot-welding Specimen)

  • 김관주;조성신;정진성
    • 한국자동차공학회논문집
    • /
    • 제11권3호
    • /
    • pp.209-213
    • /
    • 2003
  • It is advantage of accelerated vibration testing to compress service exposures to operating vibration into a reduced laboratory test by increasing the amplitude or frequency of the applied input excitations. This paper proposes an accelerated test method to estimate the high-cycle fatigue life under random excitation. The method consists of conducting a test with amplified input excitation and extrapolating linearly the lift in the accelerated condition into the real lift in field condition. The extrapolation is carried out applying the high-cycle irregular excitation fatigue theory including the rainflow counting, Miner’s damage accumulation rule, and Goodman’s mean stress correction. As a verification, those estimated lift is compared with that acquired by experiment f3r the simple case of spot welding specimen with good agreement. This testing procedure will provide an useful scheme that can reduce testing period associated with developing time schedule of new product.

진동 시험 기법의 적용에 관한 고찰 (A Study on Application of Vibration Testing Method)

  • 이창훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 추계학술대회 논문집
    • /
    • pp.587-591
    • /
    • 2012
  • Review of practical vibration test methods those applied in various industrial fields - such as automotive industry, electrics and electronics industry, defense industry and aerospace industry - is described on this paper. Swept sine test, random vibration test and advanced vibration techniques are explained according to their parametric values and also application fields of each test method are suggested by the characteristic of each method. For more proper application of each test method, standardized test specifications should be always reviewed and revised according to the transition of environmental factors.

  • PDF

자기변형 패치 트랜스듀서를 이용한 비자성 축의 비틀림 모달 테스팅 (Torsional modal testing of a non-ferromagnetic shaft by magnetostrictive patch transducers)

  • 조승현;한순우;박찬일;김윤영
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1159-1164
    • /
    • 2006
  • Torsional vibration is an important vibration mode when shafts, cylinders and pipes are considered. However, the modal testing of torsional vibrations is not an easy job to carry out because of the lack of proper transducers. This work presents a new torsional vibration transducer based on the magnetostrictive principle and its application to torsional modal testing. The transducer is so designed as to generate/measure only torsional vibrations excluding other vibration modes such as longitudinal and bending vibrations. The transducer is composed of ferromagnetic patches bonded to a test structure, permanent magnets, and a solenoid. Though patches and magnets are bonded to a structure, torsional vibrations are generated and measured wirelessly by a solenoid encircling a test structure. The proposed transducer works even at considerably high frequencies, say, tens of kilohertz. Furthermore, the transducer can be manufactured at a low price. To check the performance of the proposed method, the torsional modal testing on a hollow aluminum shaft was conducted. The results, such as eigenfrequencies, obtained by the proposed transducer agreed favorably with theoretical results.

  • PDF