• Title/Summary/Keyword: Vibration Test Control

Search Result 572, Processing Time 0.023 seconds

Modeling and Vibration Control of Hull Structure Using Piezoelectric Composite Actuators (압전복합재 작동기를 이용한 Hull 구조물의 모델링 및 진동제어)

  • Kim, Heung-Soo;Sohn, Jung-Woo;Choi, Seung-Bok
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.23 no.1
    • /
    • pp.9-15
    • /
    • 2010
  • In this paper, dynamic modeling of hull structure including surface-bonded piezoelectric composite actuator was developed and structural vibration control performance was evaluated. Cylindrical shell structure with end-caps was considered as a host structure which could be used as a simple model of fuselage of aircraft and underwater vehicles. An advanced piezoelectric composite, macro-fiber composite(MFC), which has been developed in NASA Langley Research Center was applied for the effective structural vibration control. MFC has great flexibility by using piezoceramic fiber sheet and enhanced piezoelectric effect for in-plane motion by utilizing interdigitated electrode. Governing Equations were derived from the finite element model and modal characteristics were investigated. Modal test was conducted to verify the finite element model. Optimal controller was designed and implemented for the evaluation of vibration control performance. Structural vibration was controlled effectively by applying proper control input to the piezoelectric actuators.

Experimental study on the shear failure model for concrete under compression-shear loading

  • Shu, Xiaojuan;Luo, Yili;Zhao, Chao;Dai, Zhicheng;Zhong, Xingu;Zhang, Tianyu
    • Computers and Concrete
    • /
    • v.29 no.2
    • /
    • pp.81-92
    • /
    • 2022
  • The influence of normal stress perpendicular to the potential shear plane was always neglected in existing researches, which may lead to a serious deviation of the shear strength of concrete members in practice designs and numerical analyses. In this study, a series of experimental studies are carried out in this paper, which serves to investigate the shear behavior of concrete under compression shear loading. Based on the test results, a three-phase shear failure model for cohesive elements are developed, which is able to take into consideration the influence of normal stress on the shear strength of concrete. To identify the accuracy and applicability of the proposed model, numerical models of a double-noted concrete plate are developed and compared with experimental results. Results show that the proposed constitutive model is able to take into consideration the influence of normal stress on the shear strength of concrete materials, and is effective and accurate for describing the complex fracture of concrete, especially the failure modes under compression shear loadings.

Devising an Objective Nasal Vibration Test for Nasal Resonatory Disorders

  • Choi, Hong-Shik;Park, Yong-Jae;Kim, Kwang-Moon
    • Speech Sciences
    • /
    • v.7 no.1
    • /
    • pp.39-52
    • /
    • 2000
  • The present study investigates the clinical applicability of a new device which objectively measures nasal resonating vibration via piezoelectric vibratory sensor from 10 normal volunteers, 10 patients with definite hypernasality and 10 nasal polyposis patients. For the assessment of the hypernasality, the ratio of 'ng' to 'a' as well as that of 'mama' to 'papa' passages were used. For the evaluation of hyponasality, the ratio of nasal vibration post- to pre-induced cul-de-sac resonation was calculated. In the control group, the ratio of ng/a and mama/papa passages was larger than 8, while in the hypernasality group, the ratio was markedly lower. The vibratory signals of 'a' and 'ng' increased markedly in the control group and the hypernasality group after inducing cul-de-sac resonation, while in the hyponasality group, the change was minimal.

  • PDF

Development of stiffness adjustable mount for vibration control of marine diesel generator set (박용 발전기세트 진동 제어를 위한 강성 조절형 마운트 개발)

  • Kim, W.H.;Joo, W.H.;Kim, D.H.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.10a
    • /
    • pp.89-92
    • /
    • 2012
  • Marine diesel generator(D/G) set which is supported with resilient mounts for vibration isolation has been experienced the resonance problem by the main engine or propeller excitations and rigid body modes. Then the avoidance of resonance is difficult because the several excitations and 6 rigid body modes have to be considered simultaneously. In this paper, stiffness adjustable mounts was developed and proposed to control the natural frequencies of installed D/G set. Operating concept of the mount is that the total stiffness of mount can be changed according to the engagement of secondary rubber element in addition to primary one. The performance of mount was verified with the test rig and actual experiment in D/G set.

  • PDF

Vibration mode control of a smart plate containing electro-rheological fluid (ER유체를 이용한 스마트 평판의 진동모드 제어)

  • 정상봉;박용균;최승복
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.451-455
    • /
    • 1997
  • This paper presents vibration mode control of a smart plate containing electro-rheological (ER) fluid between elastic face layers. Following the composition of a silicone oil-based ER fluid, the ER fluid-embedded plate partitioned into four sections is constructed. Then, an extensive modal test is experimentally carried out to identify field-dependent modal parameters such as mode shapes and natural frequencies of the structure with respect to different are subjected to electric fields. The distilled results from the experiment exhibit that the ER fluid can be effectively employed in a continuous fashion to tune modal behaviors of the distributed parameter systems,

  • PDF

Parameter Optimization for Vibration Control of a Cantilever Beam Using Piezoelectric Shunt Damping System (압전분기회로를 이용한 보 구조물의 진동제어 파라미터 최적화 해석)

  • Lim K.C.;Cho D.S.;Park W.C.;Kee C.D.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.918-921
    • /
    • 2005
  • According to the mechanical-electrical coupling characteristics and the electrical Impedance property of resistor-inductor-capacitor(RLC) series resonant circuit, the mechanical impedance analysis of a bimorph piezoceramic patch shunted with a series RLC resonant circuit is conducted. The displacement transfer function of a cantilever beam bonded with a piezoelectric shunt damping module is deduced in the case of single mode vibration of the beam. By the use of vibration damping theory of tuned mass damper system, the parameter optimization of piezoelectric shunt damping system is performed. The optimal resonant state of the shunting circuit can be obtained when the resister and conductor are optimally adjusted. Test results show that the vibration control effect as well improved with optimized piezoelectric shunt system.

  • PDF

Introduction and activities of ISO/TC 108/SC 6 (ISO/TC 108/SC 6 소개 및 최근 활동)

  • Kim, Nag In
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.04a
    • /
    • pp.545-547
    • /
    • 2014
  • The scope of ISO/TC 108/SC 6, revised in accordance with Doc. ISO/TC 108/SC 6 N 35, September 1997, is as follows: Standardization in the field of vibration and shock generating systems, for test purposes (including environment, seismic and dynamic testing, calibration and diagnostics) as well as auxiliary equipment and instrumentation normally associated with it. Vibration and shock generating systems as an object of standardization within ISO/TC 108/SC 6 are only those systems that are used during vibration/shock testing to determine properties of a specimen. Vibration and shock systems being used in such processes as transportation, milling, compacting, metal working, etc., as parts of vibration control systems or household appliances and in health services, are not covered by ISO/TC 108/SC 6.

  • PDF

A Study on the Development of a Hybrid Electromagnetic Actuator Against Microvibration (미진동 저감을 위한 복합형 전자기식 작동기의 개발에 대한 연구)

  • Moon, S.J.;Park, S.H.;Jeong, J.A.;Huh, Y.C.;Kim, C.H.;Choi, S.M.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.5
    • /
    • pp.475-483
    • /
    • 2011
  • A hybrid electromagnetic actuator with an air mount is designed so as to achieve the desired isolation reduce the vibration efficiency on the floor vibration. The performance specification of the hybrid electromagnetic actuator is determined based on the vibration criterion for vibration-sensitive equipment. In the design stage of the electromagnetic actuator, the simple reluctance method is adapted to analyze magnetic circuits. The result is verified by finite element analysis using ANSYS Emag. Finally, in order to confirm the design performance, a dynamic characteristic test is carried out for the prototype of a hybrid electromagnetic actuator.

Real Time 1/3 Octave Band Control System for High Intensity Acoustic Chamber (음향 챔버 내부의 1/3 옥타브 스펙트럼 실시간 제어 시스템)

  • Kim, Young-Key;Kim, Hong-Bae;Moon, Sang-Mu;Woo, Sung-Hyun;Lee, Sang-Seol
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.881-885
    • /
    • 2002
  • This paper presents the performance and the algorithm of a 1/3-octave band spectrum control system. The system is developed to provide various spectrums in a high intensity acoustic chamber. The required spectrum, which usually comes from launch vehicle company, starts from 25Hz band and ends 10kHz band. Automatic spectrum control system is preferred since the system requires short settling time to guarantee the safety of test objects and to reduce the amount of operating gas. The developed system adapted a PCI data-acquisition/signal-generation board installed in a personal computer to implement whole control logic. The control software used three cascade digital Butterworth filters using software. The filers are designed following ANSI S1.11 standard to implement 1/3 octave band filter bank. The graphical user interface of the system guides the user to follow standard operation procedure. The averaged control spectrum showed less than 0.05 dB in every running 1/3-octave band.

  • PDF

Identification of Optimal Control Parameters for a Pneumatic Active Engine Mount System (공압식 능동형 엔진마운트시스템의 최적 제어매개변수 식별)

  • Kim, Il-Jo;Lee, Jae-Cheon;Choi, Jae-Yong;Kim, Jeong-Hoon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.2
    • /
    • pp.30-37
    • /
    • 2012
  • Pneumatic Active Engine Mount(PAEM) with open-loop control system has been developed to reduce the transmission of the idle-shake vibration induced by engine effectively and economically. A solenoid valve installed between PAEM and vacuum tank is on-off switched by the Pulse Width Modulate(PWM) control signal to decrease the dynamic stiffness of the engine mount. This paper presents the methodology to identify the optimal values of control parameters of a PAEM, i.e, turn-on timing and duty ratio of PWM signal for 6 different idle driving conditions. A scanning algorithm was first applied to the vehicle test to obtain the approximate optimal control parameters minimizing the vibration at front seat rail and at steering wheel. Then the PAEM system identification was fulfilled to find accurate optimal control parameters by using multi-layer neural networks of Levenberg-Marquardt algorithm with vehicle test data.