  • Dynamic characteristics of seated human body were investigated by measuring apparent masses of eight different seating subjects exposed to vertical vibration. Two types of vibration signals - one is random signals over 1 to 30Hz having flat spectral density and the other is signals measured on seat rail in passenger car under driving conditions - were employed. It was found that the apparent masses are highly dependent on vibration level rather than type of the vibration signals. Based on the apparent mass measurements, a mathematical model of the human body in seating posture was developed by using genetic algorithm. Three-degree-of-freedom model was satisfactory in describing apparent mass of seated human body.

  • PDF

몰드변압기 진동신호의 FFT 및 시계열 계수 분석 (FFT and AR Coefficient Analysis of Vibration Signal in Mold Transformer)

  • 정용기;정종욱;김재철;곽희로
    • 조명전기설비학회논문지
    • /
    • 제12권4호
    • /
    • pp.136-145
    • /
    • 1998
  • 본 논문에서는 몰드변압기 예방진단을 위해 정상상태와 비정상상태 몰드변압기의 진동신호의 FFT 및 시계열 분석에 관해 연구하였다. 실험올 위한 제어변수들로 공급전압, 부하전류 및 주위온도를 변화시키면서, 진동신호 크기, 주파수 스펙트럼 및 시계열 계수와 같은 측정변수들을 분석하였다. 제어변수 변화에 의한 진동선호는 권선표변과 철섬에 부착된 가속도센서로 측정되었으며, 이 신호들은 중폭기를 거쳐 데이터 수집장치에서 측정변수들로 계산되었다. 또한, 정 상상태 분석 후, 몰드변압기의 구조적 변형올 모의하였다. 비정상상태 진동신호는 정상상태와 같은 제어변수 변화 에 의해 측정되었다. 연구 결과, 정상상태와 비정상상태 진동신호는 수직진동신호와 수평진동신호를 비교하여 분석함으혹써 구별이 가능하였다.

  • PDF

기어박스에서의 베어링 결함 진단 (Bearing Fault Diagnostics in a Gearbox)

  • 김흥섭;이상권
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.611-616
    • /
    • 2002
  • Bearing diagnostics is difficult in a gearbox because bearing signals are masked by the strong gear signals. Self adaptive noise cancellation(SANC) is useful technique to seperate bearing signals from gear signals. While gear signals are correlated with a long correlation length, bearing signals are not correlated with a short length. SANC seperates two components on the basis of correlation length. Then we can find defect frequency component in the envelope spectrum of the bearing signals.

  • PDF

기어 박스에서의 베어링 결함 진단 (Bearing Falut Diagnostics in a Gearbox)

  • Kim, Heung-Sup;Lee, Sang-Kwon
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.362.2-362
    • /
    • 2002
  • Bearing diagnostics is difficult in a gearbox because bearing signals are masked by the strong gear signals. Self adaptive noise cancellation(SANC) Is useful technique to seperate bearing signals from gear signals. While gear signals are correlated with a long correlation length, bearing signals are not correlated with a short length. SANC seperates two components on the basis of correlation length. (omitted)

  • PDF

진동신호를 이용한 기어체인의 고장진단 (Fault Diagnosis of Gear Chain Using Vibration Signal)

  • 배범원;최연선
    • 대한기계학회논문집A
    • /
    • 제24권7호
    • /
    • pp.1731-1739
    • /
    • 2000
  • The Vibration signals of a gear driving system is often associated with gear tooth faults. Many studies have been done on the detection of impulsive vibration signals, which characterize the breaka ge of a gear tooth. Also, most of the studies on gear fault diagnosis are only about the fault existence at one gear-pair. This study concerns on the several possible faults of a geared motor that has three gear pairs. The measurement and analysis on the vibration signals of a running geared motor shows the relationship between the gear faults and the vibration signals. This study also shows that adaptive interference canceling technique can be appropriately applicable to detect which gear-pair has the fault, and that wavelet is better than spectrogram to figure out the gear fault.

발전기 양극 회전자 밸런싱에서의 이상 진동신호 분석 (Investigation on Excessive Vibration Signals of Two-Pole Generator Rotors in Balancing)

  • 박종포;최성필;주영호
    • 소음진동
    • /
    • 제9권4호
    • /
    • pp.835-840
    • /
    • 1999
  • Cause of excessive vibration signals with twice the rotational speed of a 2-pole generator rotor in balancing for fossil power plants was investigated. The 2-pole generator rotor is treated as a typically asymmetric rotor in vibration analysis, and produces asynchronous vibration with twice the rotational speed for its own inertia and stiffness asymmetry. This paper introduces practical balancing procedure and experimental vibration data of the asymmetric 2-pole rotor in balancing, and presents the results of investigation into sources of the excessive vibration signals.

  • PDF

격자형 구조물의 외부 진동 주파수 탐지를 위한 분포형 광섬유 센서 설계 및 실험 (Detection of Excited Vibration frequency on the Latticed Fence Structure Using a Distributed Fiber Optic Sensor)

  • 이종길
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.234-237
    • /
    • 2002
  • To detect external vibration signals on the latticed fence structure, distributed fiber optic sensor using Sagnac interferometer was fabricated and tested. The latticed structure fabricated with dimension of 170cm in width and 180cm in height, the optical fiber, 50m in length, distributed and fixed on the latticed structure. It was verified the sensitivity of the Sagnac interferometer using the PZT phase modulator. Fiber optic external vibration signal spplied to the latticed fence structure from 100Hz to several kHz. The interferometeric fiber optic sensor detected the excited vibration signal very effectively without any signal processing. The detected optical signals were compared and analyzed to the detected acclerometer signals.

  • PDF

기여도함수를 이용한 농업기계의 소음원 규명 (Vibration Source Identification of Agricultural Machinery Using Coherence Function)

  • 김우택;오재응
    • Journal of Biosystems Engineering
    • /
    • 제26권6호
    • /
    • pp.503-508
    • /
    • 2001
  • In this paper, time-fiequency analysis and multi-dimensional spectral analysis methods are applied for source identification and diagnosis of non-stationary sound/vibration signals. Sound or vibration problems of general vehicle and agricultural machinary are under 500 Hz. So We used linearly increased chirp signals under 500 Hz. By checking the coherences on concerned time, fur time-variant non-stationary signals, this simulation it very well coincident to expected results.

  • PDF

ICA 기법을 이용한 구조물의 진동원 신호 규명 (Vibration Source Signal Identification of Structures Using ICA)

  • 김국현;권혁민;조대승;김재호;전재진
    • 대한조선학회논문집
    • /
    • 제49권6호
    • /
    • pp.498-503
    • /
    • 2012
  • Independent component analysis (ICA) technique based on statistical independency of the signals is known as suitable to identify the source signals by measuring and separating mixed signals through transfer paths and has successfully applied in the field of medical care, communications and so forth. In this study, the ICA technique is introduced for the identification of excitation sources from measured vibration signals of structures, which can be done by evaluating negentropy of centered and whitened vibration signals and correlation of separated signals. To validate the method, numerical analyses are carried out for a plate and a cylinder structure. The results show that the method can be applied efficiently to source identification of complex structures. Nevertheless, additional studies would be required to complement problems of occasional inaccuracy.

Implementation of Spectrum Analysis System for Vibration Monitoring

  • Nguyen, Thanh Ngoc;Jeon, Taehyun
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제11권2호
    • /
    • pp.27-30
    • /
    • 2019
  • Factory monitoring systems are gaining importance in wide areas of industry. Especially, there have been many efforts in implementation of vibration measurement and analysis for monitoring the status of rotating machines. In this paper, a digital signal processor (DSP) based monitoring system dedicated to the vibration monitoring and analysis on rotating machines is discussed. Vibration signals are acquired and processed for the continuous monitoring of the machine status. Time domain signals and fast Fourier transform (FFT) are used for vibration analysis. All of the signal processing procedures are done in the DSP to reduce the production and maintenance cost. The developed system could also provide remote and mobile monitoring capabilities to operator via internet connection. This paper describes the overview of the functional blocks of the implemented system. Test results based on signals from small-size single phase motors are discussed for monitoring and defect diagnosis of the machine status.