• 제목/요약/키워드: Vibration Modal Analysis

검색결과 1,318건 처리시간 0.024초

튜브 타입 제진용 보링바 구조설계를 위한 GUI 프로그램 개발 (Development of a GUI Program for the Design of a Vibration Control Boring Bar with a Tube-Type Structure)

  • 곽양양;박종권;홍준희;송두상
    • 한국생산제조학회지
    • /
    • 제25권4호
    • /
    • pp.295-300
    • /
    • 2016
  • In the design of passive and active boring bars, the structural dimensions and shape of the vibration control boring bar are modified depending on the diameter and depth of the workpiece, which changes the dynamic behavior. Thus, the natural frequency, effective mass, and stiffness for the main structure of a tube-type boring bar need to be reset for each vibration control case. However, commercial finite element method (FEM) software and experimental modal analysis are mostly used at present despite being too time-consuming. To overcome the weaknesses of the two methods currently used for vibration control, we realized a graphical user interface (GUI) program for the modal analysis of a modified tube-type damping structure. The analysis results with the GUI program were compared to those with commercial FEM software in order to confirm the effectiveness of the former.

Experimental evaluation of crack effects on the dynamic characteristics of a prototype arch dam using ambient vibration tests

  • Sevim, Baris;Altunisik, Ahmet Can;Bayraktar, Alemdar
    • Computers and Concrete
    • /
    • 제10권3호
    • /
    • pp.277-294
    • /
    • 2012
  • The aim of the study is to determine the modal parameters of a prototype damaged arch dam by operational modal analysis (OMA) method for some damage scenarios. For this purpose, a prototype arch dam-reservoir-foundation model is constructed under laboratory conditions. Ambient vibration tests on the arch dam model are performed to identify the modal parameters such as natural frequency, mode shape and damping ratio. The tests are conducted for four test-case scenarios: an undamaged dam with empty reservoir, two different damaged dams with empty reservoirs, and a damaged dam with full reservoir. Loading simulating random impact effects is applied on the dam to crack. Cracks and fractures occurred at the middle of the upper part of the dams and distributed through the abutments. Sensitivity accelerometers are placed on the dams' crests to collect signals for measurements. Operational modal analysis software processes the signals collected from the ambient vibration tests, and enhanced frequency domain decomposition and stochastic subspace identification techniques are used to estimate modal parameters of the dams. The modal parameters are obtained to establish a basis for comparison of the results of two techniques for each damage case. Results show that approximately 35-40% difference exists between the natural frequencies obtained from Case 1 and Case 4. The natural frequencies of the dam considerably decrease with increasing cracks. However, observation shows that the filled reservoir slightly affected modal parameters of the dam after severe cracking. The mode shapes obtained are symmetrical and anti-symmetrical. Apparently, mode shapes in Case 1 represent the probable responses of arch dams more accurately. Also, damping ratio show an increase when cracking increases.

실험모드해석에 의한 다점지지된 연속원통셸의 진동특성에 관한 연구 (A Study on the Vibrational Characteristics of the Continuous Circular Cylindrical Shell with the Multiple Supports Using the Experimental Modal Analysis)

  • 한창환;이영신
    • 한국소음진동공학회논문집
    • /
    • 제11권4호
    • /
    • pp.43-51
    • /
    • 2001
  • An experimental modal analysis is the process to identify structure's dynamic characteristics such as resonant frequencies, damping values and mode shapes. An experimental model was made of stainless steel in the shape of a circular cylindrical shell and installed on the test bed with jigs. For investigating vibrational characteristics of the continuous circular cylindrical shell with intermediate supports, modal testing is performed by using impact hammer, accelerometer and 8-channel FFT analyzer. The frequency response function(FRF) measurements are also made on the experimental model within the frequency range from 0 to 4kHz. Modal parameters are identified from resonant peaks in the FRF's and animated deformation patterns associated with each of the resonances are shown on a computer screen. The experimental results are compared with analytical and FEA results.

  • PDF

Infill wall effects on the dynamic characteristics of RC frame systems via operational modal analysis

  • Komur, Mehmet A.;Kara, Mehmet E.;Deneme, Ibrahim O.
    • Structural Engineering and Mechanics
    • /
    • 제74권1호
    • /
    • pp.121-128
    • /
    • 2020
  • This paper presents an experimental study on the dynamic characteristics of infilled reinforced concrete (RC) frames. A 1/3-scaled, one-bay, three-storey RC frame was produced and tested by using operational modal analysis (OMA). The experiments were performed on five specimens: one reference frame with no infill walls and four frames with infill walls. The RC frame systems included infill walls made of hollow clay brick, which were constructed in four different patterns. The dynamic characteristics of the patterns, including the frequency, mode shapes and damping ratios in the in-plane direction, were obtained by 6 accelerometers. Twenty-minute records under ambient vibration were collected for each model, and the dynamic characteristics were determined using the ambient vibration testing and modal identification software (ARTeMIS). The experimental studies showed that the infill walls significantly affected the frequency value, rigidity and damping ratio of the RC frame system.

변조좌표계를 이용한 비대칭/비등방 회전체의 모드 해석 (Modal analysis of asymmetric/anisotropic rotor system using modulated coordinates)

  • 서정환;홍성욱;이종원
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.304-309
    • /
    • 2003
  • A new modal analysis method for rotor systems with periodically time-varying parameters is proposed. The essence of method is to introduce modulated coordinates to derive the equivalent time-invariant equation. This paper presents a modal analysis method using modulated coordinates fur general rotors, of which rotating and stationary parts both possess asymmetric properties. The equation of motion with time-varying parameters is transformed to an infinite order matrix equation with the time-invariant parameters. A theory of modal analysis for the system is presented with the infinite order equation and a couple of reduced order equations. A numerical example with simple asymmetric rotor is provided to demonstrate the effectiveness of the proposed method

  • PDF

초정밀 선형 모터의 진동 분석 (Vibration Analysis of Super-Precision Linear Motors)

  • 설진수;이우영;임경화
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.840-845
    • /
    • 2004
  • Development of the linear motors is recently required to control a high-speed and high-resolution in the high-integrated and speed process industry. This paper presents vibration analyses as well as measurement standards of the newly developed linear motors through analyzing the vibration characteristics of the advanced products. Vibration experiments are conducted for identifying vibration level during operation. They are also included in the modal test to analyze dynamic characteristics. Analytic data using Finite Element Method (FEM) are compared with the results of the modal. The FEM and experiments make it possible to understand these characteristics. Further, through computer simulation for the behavior of moving part to be vibration source, the best acceleration pattern of moving part movement can be verified to achieve effective moving part positioning and reduce the vibration due to moving part movement.

  • PDF

가진기를 이용한 강제진동시험에 의한 전기 캐비닛의 실험적 모드특성 분석 (Analysis of Experimental Modal Properties of an Electric Cabinet via a Forced Vibration Test Using a Shaker)

  • 조성국;소기환
    • 한국지진공학회논문집
    • /
    • 제15권6호
    • /
    • pp.11-18
    • /
    • 2011
  • 원자력발전소(이하, 원전)에 설치되는 안전관련 전기기기들의 합리적인 내진검증을 위해서는 사전에 정확한 동특성분석이 필요하다. 이 연구에서는 원전에 설치되는 전기기기 캐비닛 구조를 대상으로 입력 진동의 수준에 따른 모드특성의 변화를 평가하였다. 이를 위해, 실제 전기기기 캐비닛을 시편으로 선정하고 가진 시험기를 이용하여 입력진동에너지의 크기를 변화시켜 가면서 진동시험을 수행하였다. 시험은 캐비닛의 문짝을 부착한 경우와 탈거한 경우로 구분하여 수행하였다. 진동시험을 통하여 계측된 시편의 가속도응답신호와 입력운동신호로부터 진동의 크기에 따라 진동수응답함수를 작성하였다. 다항식회귀분석기법을 이용한 모드분석기법으로 시편의 진동수응답함수를 분석하여 모드특성을 추출하고, 진동수준에 따른 시편의 동특성 변화를 검토하였다. 연구결과, 대상 기기는 입력진동의 크기가 증가할수록 모드진동수와 모드감쇠비가 비선형적으로 변화하는 것을 확인하였다. 문짝이 부착된 경우에는 문짝이 탈거된 경우에 비하여 캐비닛의 모드감쇠가 증가한다.

Structural noise mitigation for viaduct box girder using acoustic modal contribution analysis

  • Liu, Linya;Qin, Jialiang;Zhou, Yun-Lai;Xi, Rui;Peng, Siyuan
    • Structural Engineering and Mechanics
    • /
    • 제72권4호
    • /
    • pp.421-432
    • /
    • 2019
  • In high-speed railway (HSR) system, the structure-borne noise inside viaduct at low frequency has been extensively investigated for its mitigation as a research hotspot owing to its harm to the nearby residents. This study proposed a novel acoustic optimization method for declining the structure-borne noise in viaduct-like structures by separating the acoustic contribution of each structural component in the measured acoustic field. The structural vibration and related acoustic sourcing, propagation, and radiation characteristics for the viaduct box girder under passing vehicle loading are studied by incorporating Finite Element Method (FEM) with Modal Acoustic Vector (MAV) analysis. Based on the Modal Acoustic Transfer Vector (MATV), the structural vibration mode that contributes maximum to the structure-borne noise shall be hereinafter filtered for the acoustic radiation. With vibration mode shapes, the locations of maximum amplitudes for being ribbed to mitigate the structure-borne noise are then obtained, and the structure-borne noise mitigation performance shall be eventually analyzed regarding to the ribbing conduction. The results demonstrate that the structural vibration and structure-borne noise of the viaduct box girder mainly occupy both in the range within 100 Hz, and the dominant frequency bands both are [31.5, 80] Hz. The peak frequency for the structure-borne noise of the viaduct box girder is mainly caused by $16^{th}$ and $62^{th}$ vibration modes; these two mode shapes mainly reflect the local vibration of the wing plate and top plate. By introducing web plate at the maximum amplitude of main mode shapes that contribute most to the acoustic modal contribution factors, the acoustic pressure peaks at the field-testing points are hereinafter obviously declined, this implies that the structure-borne noise mitigation performance is relatively promising for the viaduct.