• 제목/요약/키워드: Vibration Isolation Element

검색결과 49건 처리시간 0.025초

Numerical investigation on multi-degree-freedom nonlinear chaotic vibration isolation

  • Jiang, Guoping;Tao, Weijun
    • Structural Engineering and Mechanics
    • /
    • 제51권4호
    • /
    • pp.643-650
    • /
    • 2014
  • A chaotic vibration isolation system is designed according to the chaotic vibration theory in this paper. The strong nonlinearity is generated by the system. Line spectra in the radiated noise maybe easily detected caused by marine vessels. It is Important to reduce the line spectra by improving the acoustic stealth of marine vessels. A multi-degree-freedom (MDF) nonlinear vibration isolation system (NVIS) system is setup by the experiment and finite element method. The model is established with finite element method. The results show that the behavior of the device gradually varies from period bifurcation into chaotic state and the line spectrum is changed from single spectral structure into broadband spectral structure. It is concluded that chaotic vibration isolation is preferable contrasted on line spectra isolation.

대형 잔향실의 방진 설계 및 검증 (Vibration Isolation System of a Large Reverberation Chamber)

  • 김영기;김홍배;이동우;우성현;문상무
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.1026-1031
    • /
    • 2003
  • A vibration isolation system fur a large reverberation chamber (1,228㎥, 1,000ton) has been installed. The reverberation chamber generates loud noise and induces high level of vibration to perform spacecraft acoustic environmental tests. The isolation system prevents vibration transfer from the chamber to enclosure buildings. This paper describes logical design process and commissioning experiments of the system. Design criteria have been induced from rigid body model of the chamber. Finite element model has been employed to select the characteristics of rubber pads. A total of 21 rubber pads have been installed between the chamber and supporting pedestals. A sand bag of 800kg was dropped on the chamber floor to measure the natural frequency of the isolation system. Absolute transmissibility has been measured while generating 145㏈ in the chamber. The natural frequency of the chamber is 10.5㎐, which is 80% of estimated value. Overall transmissibility at working frequency range (25㎐-10,000㎐) is less than -6㏈.

  • PDF

정밀 제진대 개발 및 동특성에 관한 실험적 연구 (Development of precision vibration isolation table and study of dynamic characteristics with experiment)

  • 김인수;김종연;한문성;김영중
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 I
    • /
    • pp.329-334
    • /
    • 2001
  • Recently, the high precision technology can not be developed continuously if we don't have anti vibration technology. Vibration isolation technology using an air spring and laminated robber bearing is widely used because it has excellent vibration isolation characteristics. We developed high precision vibration table with two good element(air spring and LRB) for semiconductor factory. Air Spring is used for isolating the vertical vibration and LRB is used for isolating the horizontal Vibration. As a result, It has D-Class degree in BBR-Criteria. In this paper, we talk about orifice characteristics in the self-damped air spring and design flow of the laminated robber bearing. The orifice characteristics is delicate shade of length and diameter. When we do experimentation to find orifice characteristics, length is fixed and diameter is changed. The orifice diameter is the wider and the air spring stiffness is the softer.

  • PDF

제진을 위한 3 자유도 정밀 스테이지의 설계와 모델링 (Design and Modeling of a 3-DOF Precision Stage for Vibration Isolation)

  • 문준희;김화수;박희재
    • 한국정밀공학회지
    • /
    • 제24권3호
    • /
    • pp.124-133
    • /
    • 2007
  • Active vibration isolation systems need the following performance specifications which are different from those of existing positioning systems: usage of seismic sensors, strict suppression of phase lead/lag in signal processing for sensors and actuators, excellent control in low frequency range and so on. In consideration of such specifications, a 3-DOF precision stage for vibration isolation is designed and modeled based on the physical characteristics. Then the major parameters such as spring constants and damping coefficients are valued by the system identification method using empirical transfer function. Finite element analysis is used as a verification and simulation tool throughout this research. This paper lays the foundation for the future research on the control of the active vibration isolation system.

대형 잔향실의 방진 구조 설계 및 검증시험 (Design and Verification of a Large Reverberation Chamber's Isolation System)

  • 김홍배;이득웅
    • 한국소음진동공학회논문집
    • /
    • 제14권11호
    • /
    • pp.1066-1074
    • /
    • 2004
  • A vibration isolation system for a large reverberation chamber (1,228 $m^3$ and 1,000 ton) has been installed and verified. The reverberation chamber generates loud noise and induces high level of vibration while performing spacecraft acoustic reliability tests. The isolation system prevents vibration transfer from the chamber to the enclosure buildings. This paper describes design process and commissioning experiments of the system. Design criteria have been derived from rigid body model of the chamber. The stiffness of neoprene pads has been selected by employing finite element analysis of the reverberant chamber and isolation system. A total of 21 neoprene pads have been installed between the chamber and supporting Pedestals. A sand bag of 800kg was dropped on the chamber floor to measure the natural frequency of the isolation system. While 136.9 dB noise is generated in the chamber, absolute transmissibility of the isolation system has been measured. The measured natural frequency of the chamber is 10.2Hz, which is 80% of the predicted value. Overall transmissibility at working frequency range (25∼10.000 Hz) is less than -12.4 dB.

다양한 수동 진동 절연 장치의 진동 절연 특성 비교 (A Comparison of Vibration Isolation Characteristics of Various Forms of Passive Vibration Isolator)

  • 이대은;한재흥
    • 한국소음진동공학회논문집
    • /
    • 제22권9호
    • /
    • pp.817-824
    • /
    • 2012
  • 정밀 시스템에 전달되는 진동은 시스템의 성능 저하 및 오작동을 초래할 수 있기 때문에 저감되어야 한다. 진동을 저감시키는 가장 일반적인 방법은 진동이 전달되는 경로에 수동 진동 절연 장치를 도입함으로 전달되는 진동을 절연시키는 방법이다. 탄성소자와 점성 감쇠기로 구성된 일반적인 수동 진동 절연 장치는 공진에서의 전달률을 낮추기 위해서 고주파수 대역에서 진동 절연 성능을 희생해야 하는 단점을 지니고 있다. 이 논문에서는 공진에서 낮은 전달률과 고주파수 대역에서 높은 진동 절연 성능을 동시에 가진 수동 진동 절연 장치들의 특성을 비교 분석하였다.

다양한 수동 진동 절연 장치의 진동 절연 특성 비교 (A Comparison of Vibration Isolation Characteristics of Various Forms of Passive Vibration Isolator)

  • 이대은;한재흥
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 춘계학술대회 논문집
    • /
    • pp.232-237
    • /
    • 2012
  • 정밀 시스템에 전달되는 진동은 시스템의 성능 저하 및 오작동을 초래할 수 있기 때문에 저감되어야 한다. 진동을 저감시키는 가장 일반적인 방법은 진동이 전달되는 경로에 수동 진동절연 장치를 도입함으로 전달되는 진동을 절연시키는 방법이다. 탄성소자와 점성 감쇠기로 구성된 일반적인 수동 진동 절연 장치는 공진에서의 전달율을 낮추기 위해서 고주파수 대역에서 진동 절연 성능을 희생해야 하는 단점을 지니고 있다. 본 논문에서는 공진에서 낮은 전달율과 고주파수 대역에서 높은 진동 절연 성능을 동시에 가진 수동 진동 절연 장치들의 특성을 비교 분석하였다.

  • PDF

중량바닥충격에 의한 소음 및 진동 특성 (Noise and Vibration Characteristics by Heavy-weight Floor Impact)

  • 서상호;송희수;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.919-922
    • /
    • 2003
  • The correlation between noise and vibration by a heavy-weight floor impact was studied. The triggering technique was used for increasing the reliability and stability to measure the level of sound pressure, sound intensity and vibration acceleration. The simple finite element and rigid body analysis method were suggested to calculate the natural frequencies of the multi-layer floor system. The result show that the isolation material adapted to reduce the light-weight floor impact noise, causing the natural frequency lower, make resonance with dominant driving frequency, and increase the noise level very sharply. Therefore the noise level Peak in the region of low frequency, below 63Hz, would be related with the natural frequencies of the floor system.

  • PDF

광디스크 드라이브의 방진계 최적설계 (Optimal Design of Vibration Isolation System in Optical Disc Drives)

  • 이은경;이기성;장헌탁;임경화
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 II
    • /
    • pp.961-966
    • /
    • 2001
  • The schematic design process is formulated to develop the vibroisolating rubber mount in optical disc drives. The dynamic model of vibration isolation system is established by using a rigid body with 6 degree of freedom and linear springs with damping property. Considering the practical vibration condition of DVDP(Digital Versatile Disk Player), the required properties of vibroisolating rubber mounts are investigated. Also finite element model of a vibroisolating rubber mount is used to obtain shape design concept and identify the characteristics of a rubber mount which satisfies the required properties from previous design stage. Finally the evaluation method of dynamic properties of vibroisolating rubber mounts is established by utilizing modal test method. Based on the developed process, vibroisolating rubber mounts with a good performance have been developed.

  • PDF

Design theory and method of LNG isolation

  • Sun, Jiangang;Cui, Lifu;Li, Xiang;Wang, Zhen;Liu, Weibing;Lv, Yuan
    • Earthquakes and Structures
    • /
    • 제16권1호
    • /
    • pp.1-9
    • /
    • 2019
  • To provide a simplified method for the base isolation design of LNG tanks, such as $16{\times}104m^3$ LNG tanks, we conducted a derivation and calculation example analysis of the dynamic response of the base isolation of LNG storage tanks, using dynamic response analysis theory with consideration of pile-soil interaction. The ADINA finite element software package was used to conduct the numerical simulation analysis, and compare it with the theoretical solution. The ground-shaking table experiment of LNG tank base isolation was carried out simultaneously. The results show that the pile-soil interaction is not obvious under the condition of base isolation. Comparing base isolation to no isolation, the seismic response clearly decreases, but there is less of an effect on the shaking wave height after adopting pile top isolation support. This indicates that the basic isolation measures cannot control the wave height. A comparison of the shaking table experiment with the finite element solution and the theoretical solution shows that the finite element solution and theoretical solution are feasible. The three experiments are mutually verified.