• 제목/요약/키워드: Vibration Environmental Test

검색결과 313건 처리시간 0.038초

랜덤진동제어에서 치구성능향상을 위한 기준스펙트럼의 최적화에 대한 연구 (A study on Optimization of Reference Spectrum for Improvement of Fixture Performance in Random Vibration Control)

  • 김준엽;정의봉
    • 대한기계학회논문집
    • /
    • 제19권1호
    • /
    • pp.284-291
    • /
    • 1995
  • This paper proposes a method for determination of optimal reference spectrum in random vibration control. The least square method is used to minimize the spectrum deviation between the specified reference spectrum and spectra at the specimen-mounted points. This method needs only the measured FRF's at the control point and specimen-mounted points in pre-vibration test. Using the proposed method as reference spectrum, it is possible to easily predict spectra at the specimen-mounted points, and also to reduce overtest resulting from dynamic characteristics of shaker and fixture. This method is shown through theoretical and experimental results to be an effective method.

설정 음압 및 스펙트럼 재현을 위한 음향 환경 시험 챔버의 기본 설계 변수 선정 (Design of High Intensity Acoustic Test Facility to Generate Required Sound Pressure Level and Spectrum)

  • 김영기;우성현;김홍배;문상무;이상설
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.867-872
    • /
    • 2002
  • A high intensity acoustic test facility is constructed at Korea Aerospace Research Institute (KARI) by 2003. The reverberant chamber of the facility has a volume of 1,228 cubic meters and shall provide an acoustic environment of 152 dB over the frequency range of 25 Hz to 10,000 Hz. The facility consists of a large scaled reverberant chamber, acoustic power generation systems, gases nitrogen supply systems, and acoustic control systems. This paper describes how the basic parameters of a chamber and power generation systems are controlled to meet the requirement of the test. The volume of a reverberant chamber is controlled by the size of test objects and the reverberant characteristics of a chamber. The capacity of acoustic power generation systems is determined by the energy absorption of a chamber and the efficiency of acoustic modulators. Simple math is employed to calculate the required power of acoustic modulators. Moreover, the paper explains how the distribution of sound pressure level at low frequency is checked by analytical and numerical methods.

  • PDF

A multi-functional cable-damper system for vibration mitigation, tension estimation and energy harvesting

  • Jung, Hyung-Jo;Kim, In-Ho;Koo, Jeong-Hoi
    • Smart Structures and Systems
    • /
    • 제7권5호
    • /
    • pp.379-392
    • /
    • 2011
  • This paper presents a multi-functional system, consisting of a magnetorheological (MR) damper and an electromagnetic induction (EMI) device, and its applications in stay cables. The proposed system is capable of offering multiple functions: (1) mitigating excessive vibrations of cables, (2) estimating cable tension, and (3) harvesting energy for wireless sensors used health monitoring of cable-stayed bridges. In the proposed system, the EMI device, consisting of permanent magnets and a solenoid coil, can converts vibration energy into electrical energy (i.e., induced emf); hence, it acts as an energy harvesting system. Moreover, the cable tension can be estimated by using the emf signals obtained from the EMI device. In addition, the MR damper, whose damping property is controlled by the harvested energy from the EMI device, can effectively reduce excessive cable vibrations. In this study, the multi-functionality of the proposed system is experimentally evaluated by conducting a shaking table test as well as a full-scale stay cable in a laboratory setting. In the shaking table experiment, the energy harvesting capability of the EMI device for wireless sensor nodes is investigated. The performance on the cable tension estimation and the vibration mitigation are evaluated using the full-scale cable test setup. The test results show that the proposed system can sufficiently generate and store the electricity for operating a wireless sensor node twice per day, significantly alleviate vibration of a stay cable (by providing about 20% larger damping compared to the passive optimal case), and estimate the cable tension accurately within a 2.5% error.

IDENTIFICATINO OF DYNAMIC PARAMETER OF THE RUBBER CRAVLES SYSTEM FOR FARM MACHINERY

  • Inoue, Eiji;Konya, Hideyuki;Hirai, Yasumaru;Noguchi, Ryozo;Hashiguchi, Koichi;Choe, Jung-Seob
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 2000년도 THE THIRD INTERNATIONAL CONFERENCE ON AGRICULTURAL MACHINERY ENGINEERING. V.II
    • /
    • pp.146-153
    • /
    • 2000
  • The rubber crawler system for farm machine is composed of driving units such as track rollers, driving sprockets and rubber crawlers. Vibration characteristics of the rubber crawler system varies by driving speed, center of gravity, mass□moment of inertial□location arrangement of track rollers and dynamic parameters such as dynamic spring constant (k) and viscous damping coefficient (c) of a rubber crawler. In general, vibration of the rubber crawler system occurs by reason for mechanical interaction between the rubber crawler and track rollers. Because the dynamic spring constant and viscous damping coefficient vary periodically by mechanical characteristics(deformation characteristics) of the rubber crawler when track rollers drive on the between lugs of the rubber crawler. Therefore, both dynamic parameters k and c were expressed as Fourier series by authors through the shaking test of the rubber crawler and further, vibration characteristics of the rubber crawler system could be simulated analytically. However, actual values of dynamic parameters k and c are different from those obtained by the shaking test because dynamic characteristics of the rubber crawler vary by the effect of variable tension and driving resistance of track rollers. So, actual values of k and c should be identified in the condition of actual driving test. In this study, dynamic parameters such as k and c of the rubber crawler system, which are expressed as Fourier series, were identified using the Gauss-Newton Method. Therefore, validity of identified parameters k and c was discussed through the simulation using experimental data of actual driving test. As a result, in the Fourier series of dynamic parameters of spring constant k and viscous damping coefficient c, excellent parameter convergence and simulation were observed using the Fourier series' zero order and first term of the dynamic model. Furthermore, it was clarified that identification for model parameters which are fitted to actual dynamic motion (vibration) wave of the crawler system was possible by using the time series data observed in vertical and pitching motion of the crawler system.

  • PDF

Sn-Ag-Cu-X 무연솔더로 솔더링 된 접합부의 진동파괴 거동 (Behavior of Vibration Fracture for Sn-Ag-Cu-X Solders by Soldering)

  • 진상훈;강남현;조경목;이창우;홍원식
    • Journal of Welding and Joining
    • /
    • 제30권2호
    • /
    • pp.65-69
    • /
    • 2012
  • Environmental and health concerns over the lead have led to investigation of the alternative Pb-free solders to replace commonly used Pb-Sn solders in microelectronic packaging application. The leading candidates for lead-free solder alloys are presently the near eutectic Sn-Ag-Cu alloys. Therefore, extensive studies on reliability related with the composition have been reported. However, the insufficient drop property of the near eutectic Sn-Ag-Cu alloys has demanded solder compositions of low Ag content. In addition, the solder interconnections in automobile applications like a smart box require significantly improved vibration resistance. Therefore, this study investigated the effect of alloying elements (Ag, Bi, In) on the vibration fatigue strength. The vibration fatigue was conducted in 10~1000Hz frequency and 20Grms. The interface of the as-soldered cross section close to the Cu pad indicated the intermetallic compound ($Cu_6Sn_5$) regardless of solder composition. The type and thickness of IMC was not significantly changed after the vibration test. It indicates that no thermal activities occurred significantly during vibration. Furthermore, as a function of alloying composition, the vibration crack path was investigated with a focus on the IMCs. Vibration crack was initiated from the fillet surface of the heel for QFP parts and from the plating layer of chip parts. Regardless of the solder composition, the crack during a vibration test was propagated as same as that during a thermal fatigue test.

MIL-HDBK-344A 기반의 유도탄 내부 케이블 ESS 시험 방안 (Test Method for Guided Missile Cable ESS(Environmental Stress Screening) Based on MIL-HDBK-344A)

  • 이대현;이정민;오택근;이홍범;정준영
    • 한국항행학회논문지
    • /
    • 제25권5호
    • /
    • pp.313-319
    • /
    • 2021
  • 본 논문에서는 MIL-HDBK-344A 기반의 ESS(environmental stress screening) 시험 에 대해 소개하고, 유도탄 내부 케이블의 ESS 시험에 대한 목적과 규격 설정 및 시험 방안에 대하여 확인하였다. ESS 시험구성은 온도 순환과 랜덤 진동의 환경 자극으로 이루어져 있으며, 핸드북의 절차를 기반으로 유도탄 내부 케이블의 ESS 시험 규격 설정과 시험 구성을 제시하고, 진동 시험을 위한 유도탄 내부 케이블의 ESS 시험을 위한 치구를 제작하였다. 스크린 강도(SS; screening strength)를 통해 결정되는 결함 감지 확률은 일회성으로 사용되는 유도탄의 신뢰성에 부합되도록 선정하였고, 또한 ESS 시험 중 유도탄 내부 케이블의 검사방법과 고려해야 할 점에 대하여 소개하였다.

A study on Automatic field Test Equipment with improved maintenance and environmental reliability

  • Lee, Seok-Min
    • 한국컴퓨터정보학회논문지
    • /
    • 제23권3호
    • /
    • pp.9-16
    • /
    • 2018
  • In this paper, I purpose one of the development methods for portable Automatic field Test Equipment(ATE) with VME form factor. Almost portable ATE have not used to standards form factor and they are connected by mechanical non-rigid general connectors and wire harnesses among the components. Furthermore, it is hard to reuse developed board. So, it decreases to reusability of developed board and it is hard to maintenance of ATE. Even those things have weakness for vibration and drop test especially in portable ATE. The XK9A1 ATE using VME form factor has environmental reliability through vibration, drop, temperature test. It consists of 5 developed board called the control board, the wire & wireless communication board, the power supply board, the load board and the mother board. It is connected by two wire harnesses between mother board and extern circular connectors. The control board send the data and address to other board though each 16-bit data and 20-bit address line. You can develop the function board what you want to using those data & address line when it comes to needing other function board.

Effects of Sinusoidal Vibration Fatigue on Compression Strength of Corrugated Fiberboard Container for Packaging of Fruits

  • Jung, Hyun-Mo;Kim, Jong-Kyoung;Kim, Man-Soo
    • 한국포장학회지
    • /
    • 제16권1호
    • /
    • pp.1-4
    • /
    • 2010
  • The compression strength of corrugated fiberboard containers for packaging the agricultural products rapidly decreases because of various environmental conditions during distribution of unitized products. Among various environmental conditions, the main factors affecting the compression strength of corrugated fiberboard are absorption of moisture, long-term accumulative load, and fatigue caused by shock and vibration. An estimated rate of damage for fruit during distribution is about 30~40% owing to the shock and vibration. This study was carried out to characterize the durability of corrugated fiberboard containers for packaging the fruits and vegetables under simulated transportation environment. After the packaging freight was vibrated at various experimental conditions, the compression test for the packaging was performed. The compression strength of corrugated fiberboard containers decreased with loading weight and vibration time. The multiple nonlinear regression equation ($R^2$ = 0.9198) for predicting the decreasing rate of compression strength of corrugated fiberboard containers were developed using four independent variables such as input acceleration level, input frequency, loading weight and vibration time.

  • PDF

Vibration behaviour of cold-formed steel and particleboard composite flooring systems

  • AL Hunaity, Suleiman A.;Far, Harry;Saleh, Ali
    • Steel and Composite Structures
    • /
    • 제43권3호
    • /
    • pp.403-417
    • /
    • 2022
  • Recently, there has been an increasing demand for buildings that allow rapid assembly of construction elements, have ample open space areas and are flexible in their final intended use. Accordingly, researchers have developed new competitive structures in terms of cost and efficiency, such as cold-formed steel and timber composite floors, to satisfy these requirements. Cold-formed steel and timber composite floors are light floors with relatively high stiffness, which allow for longer spans. As a result, they inherently have lower fundamental natural frequency and lower damping. Therefore, they are likely to undergo unwanted vibrations under the action of human activities such as walking. It is also quite expensive and complex to implement vibration control measures on problematic floors. In this study, a finite element model of a composite floor reported in the literature was developed and validated against four-point bending test results. The validated FE model was then utilised to examine the vibration behaviour of the investigated composite floor. Predictions obtained from the numerical model were compared against predictions from analytical formulas reported in the literature. Finally, the influence of various parameters on the vibration behaviour of the composite floor was studied and discussed.

부하변동에 따른 풍력발전기용 증속기의 음향파워 특성 (Characteristics for Sound Power of Wind Turbine Gearbox by Load Variation)

  • 이재정;이승용;서영욱;이진현
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 춘계학술대회 논문집
    • /
    • pp.311-315
    • /
    • 2012
  • In these days, promising renewable energy, wind turbine is clean energy but has an environmental pollutant which is noise. Noise assessment is one of the major performance evaluations for wind turbine and nowadays, developing and research for measurement and method of the assessment considering environmental pollutants is being important. Object in this study is that figuring out sound power characteristic of the gearbox for wind turbine through measuring sound intensity. In back-to-back test, we can figure out the noise characteristic of the gearbox for wind turbine through comparing and measuring sound pressure level, sound power level in operating at the each load condition respectively.

  • PDF