• 제목/요약/키워드: Vibration Calibration

검색결과 107건 처리시간 0.022초

레이저 간섭계를 이용한 진동 가속도계의 절대교정 (Primary vibration calibration by laser interferometry)

  • 이두희;이용봉;전병수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 II
    • /
    • pp.1356-1360
    • /
    • 2001
  • A number of calibration methods are described in ISO 16063 (revision of ISO 5347) and they may be used for special purposes. However, the use of a laser interferometer is recommended for primary calibration. This paper introduces the primary vibration calibration by measuring displacement amplitude and frequency using laser interferometry.

  • PDF

ISO/TC 108/SC 3 표준 제·개정 현황 (Current Status of ISO/TC 108/SC 3 Standards and Drafts under Development)

  • 정완섭
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 춘계학술대회 논문집
    • /
    • pp.540-542
    • /
    • 2014
  • This paper introduces main activities of ISO/TC 108/SC 3 and published standards. Two working groups (WG 1 and WG 6) have been orgnized to review and revise ISO standards, specifically related to measurement and calibration subjects of vibration and shocks. A new joint working group (JWG1) with IEC/SC 47E (Semiconductor acceleration calibration) has started to deal with calibration methods for analog and digital output MEMS accelerometers. Finally, Published ISO standards, technically super-visored by ISO/TC 108/SC 3, are listed in this paper to help readers understand their main contents.

  • PDF

가속도계 정밀 위상 교정 시스템 (Precision Phase Calibration System of Accelerometers)

  • 이용봉;정성수;진종한
    • 한국정밀공학회지
    • /
    • 제28권5호
    • /
    • pp.585-590
    • /
    • 2011
  • Accelerometers have been exploited widely in various fields from monitoring vibration of precision machines to detecting an earthquake wave. The precision calibration of the accelerometers is required to maintain the measurement reliability when measuring the vibration of objects with accelerometers for modal analysis. Among evaluation factors for determining sensitivity of accelerometers, phase delay term should be also considered for accurate calibration. In this paper, a new calibration system of accelerometers capable of measuring phase delay as well as magnitude of its sensitivity was proposed and realized in the frequency range of 20 Hz to 5 kHz.

외란을 고려한 스트랩다운 관성항법장치 자이로 바이어스 교정기법 (A Study on the SDINS's Gyro Bias Calibration Method in Disturbances)

  • 이윤선;이상정
    • 한국군사과학기술학회지
    • /
    • 제12권3호
    • /
    • pp.368-377
    • /
    • 2009
  • In this paper we study the gyro bias calibration method of SDINS(Strap-Down Inertial Navigation System). Generally, SDINS's calibration is performed in 2-axis(or 3-axis) rate table with chamber for varying ambient temperature. We assumed that the majority of calibration-parameter except for gyro bias is knowned. During gyrobias calibration procedure, it can be induced some disturbances(accelerometer's short-term error induced rate table rotation and anti-vibration mount's rotation). In these cases, old gyro-bias calibration methods(using velocity error or attitude error) have an error, because these disturbances are not detectable at the same time. So that, we propose a new gyro-bias calibration method(heading error minimizing using equivalent linear transformation) that can detect anti-vibration mount's rotation. And we confirm efficiency of the new gyro-bias calibration method by simulation.

레이저 간섭계를 이용한 진동 가속도계 절대교정 시스템 자동화 (Automation of Primary Vibration Calibration System Using Laser Interferometer)

  • 조승일;이용봉;전병수;이종규;이두희
    • 한국소음진동공학회논문집
    • /
    • 제15권11호
    • /
    • pp.1241-1247
    • /
    • 2005
  • An automation of primary vibration calibration system was developed and tested. Using GPIB interface, the console PC make the control of equipments, signal collecting and save measuring results automatically by the instructions in the program by Visual Basic. Several trials of automatic calibration for the accelerometer(ENDEVCO 2270) using this developed system give the reliable results.

정밀 축진동 측정에 사용되는 비접촉식 진동센서의 측정오차 (Measurement Errors of Non-contact Type Vibration Sensors Used for Precision Measurement of Shaft Vibration)

  • 전오성;김동혁;최병천
    • 소음진동
    • /
    • 제1권2호
    • /
    • pp.107-113
    • /
    • 1991
  • When non-contact type vibration probes are used for the precision measurement of shaft vibration, they can induce the measurement errors due to the shaft curvature since they have been calibrated for the flat plate. In this study the errors due to the shaft radius and the misalignment between the shaft and probe centerlines are analyzed, and an in-situ calibration tool, which can be conveniently used for calibration independent of the shaft curvature and material, is introduced.

  • PDF

Reports on the Meetings of ISO/TC108 Mechanical Vibration and Shock and ISO/TC108/SC3 Use and Calibration of Shock Measuring Instruments Tokyo, Nov. 4-8, 2002

  • Kim, Kwang-Joon
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.468-474
    • /
    • 2003
  • 1. Schedule for the meetings of ISO/TC108 Mechanical vibration and shock and ISO/TC108/SC3 Use and calibration of shock measuring instruments 2. Minutes for the seventh meeting of ISO/TC108/WG23 Mechanical vibration and shock - Resilient mounting systems - Information for the application of source and receiver isolation (omitted)

  • PDF

KRISS에서 수행된 음향관련 교정 및 시험 동향 (Tendency of Calibration and Test for Acoustic Field in KRISS)

  • 서재갑;권휴상;정성수;조문재;서상준
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.448-452
    • /
    • 2002
  • We report the number of calibration and test for acoustic field which were conducted in KRISS between the year of 1990 and 2001. The items contain sound level meter and calibrator for calibration and sound absorption coefficient, transmission loss, sound pressure level of siren, sound pressure level and power of acoustic instrument and relative accessories for test. The data show that the number of them have been increased continuously.

  • PDF

3방향 진동감지기의 제작 및 검증 (Development and Calibration of 3-Component Vibration Transducer)

  • 김동수;이진선;조성호
    • 한국지반공학회지:지반
    • /
    • 제13권4호
    • /
    • pp.121-134
    • /
    • 1997
  • 교통하중이나 건설 작업에 의해 야기되는 지반진동은 인접구조물에 손상을 입히거나 인근 주민들의 생활에 큰 불편을 야기할 수 있으므로 중요하게 측정, 관리되어야 한다. 지반진동으로 인해 발생하는 구조물의 손상은 진동의 직접 전파에 의한 구조물의 손상과 지반진동으로 야기된 지반의 부등 침하의 두 가지 원인으로 분류될 수 있다. 지반진동에 의한 피해를 효과적으로 줄이기 위해서는 현장에서의 정화한 진동의 측정이 필수적이다. 본 논문에서는 지반진동의 측정에 사용되어지는 대표적인 진동감지기인 속도계의 검증 방법에 대해 기술하였으며, 주파수대역 출력특성이 검증되어진 개개의 속도계로 부터 진동이 전파되는 매질인 지중에서 지반진동이 측정 가능한 3방향 진동 측정기를 제작하였고 진동측정기의 검증 및 운용법에 대하여 상세히 설명하였다. 또한 제작된 3방향 진동측정기로 열차진동, 말뚝항타진동 및 발파진동을 측정하여 적용성을 평가 하였다.

  • PDF

회전 진동 교정 장치 구현을 위한 고정밀 측정기법에 대한 연구 (Study on the Precision Method of Measuring angular displacement for the Angular Vibration Calibration System)

  • 정완섭;이용봉;이두희
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.685-688
    • /
    • 2004
  • This paper addresses the study on developing the angular vibration calibration system which requires the highly accurate measurement technique of the amplitude and period of an oscillating angular motion. Two developed models for the low and high frequency ranges are introduced and their main features are also compared. In addition to the angular vibration exciters, a new measurement method, referred to the 'equi-angle sampling method', is proposed and its theoretical backgrounds are introduced. The proposed method is shown to provide much less measurement uncertainty, compared the fringe counting method. Experimental results demonstrate what amount of angular vibration amplitude measurement uncertainty is improved by suing the proposed equi-angle sampling method.

  • PDF