• Title/Summary/Keyword: Vibration Amplitude

Search Result 1,040, Processing Time 0.026 seconds

Vortex-induced oscillations of bridges: theoretical linkages between sectional model tests and full bridge responses

  • Zhang, Zhitian;Ge, Yaojun;Chen, Zhengqing
    • Wind and Structures
    • /
    • v.19 no.3
    • /
    • pp.233-247
    • /
    • 2014
  • Vortex-induced oscillation is a type of aeroelastic phenomenon, to which extended structures such as long-span bridges are most susceptible. The vortex-induced vibration (VIV) behaviors of a concerned bridge were investigated conventionally in virtue of wind tunnel tests on string-mounted sectional models. This necessitates the building of a linkage between the response of the sectional model and that of the prototype structure. Although many released literatures have related to this issue and provided suggestions, there is a lack of consistency among them. In this study, some theoretical models describing the vortex-induced structural motion, including the linear empirical model, the nonlinear empirical model and the modified (or generalized) nonlinear empirical model, are firstly reviewed. Then, the concept of equivalent mass density is introduced based on the principle that an equal input of energy should result in identical structural amplitudes. Based on these, the theoretical linkages between the amplitude of a section model and that corresponding to the prototype bridge are discussed with different analytical models. Theoretical derivation indicates that such connections are dependent mainly on two factors, one is the presupposed shape of deformation, and the other is the theoretical VIV model employed. The theoretical analysis in this study shows that, in comparison to the nonlinear empirical models, the linear one can result in obvious larger estimations of the full bridges' responses, especially in cases of cable-stayed bridges.

Seismic analysis of bridges based on stress-dependent damping

  • Su, Li;Wang, Yuanfeng;Li, Pengfei;Mei, Shengqi;Guo, Kun
    • Structural Engineering and Mechanics
    • /
    • v.62 no.3
    • /
    • pp.281-289
    • /
    • 2017
  • Damping value has considerable influence on the dynamic and seismic behaviors of bridges. However, currently the constant damping ratios that are prescribed by most bridge seismic design codes can't truly represent the complicated damping character of actual structures. In this paper, a cyclic loading experiment was conducted to study the effect of stress amplitude on material damping of concrete to present an analyzing model of the material damping of concrete. Furthermore, based on the fundamental damping of structure measured under ambient vibration, combined with the presented stress-dependent material damping concrete, the seismic response of a bridge pier was calculated. Comparison between the calculated and experiment results verified the validity of the presented damping model. Finally, a modified design and analysis method for bridge was proposed based on stress-dependent damping theory, and a continuous rigid frame bridge was selected as the example to calculate the actual damping values and the dynamic response of the bridge under different earthquake intensities. The calculation results indicated that using the constant damping given by the Chinese seismic design code of bridges would overestimate the energy dissipation capacity of the bridge.

Response of structure with controlled uplift using footing weight

  • Qin, X.;Chouw, N.
    • Earthquakes and Structures
    • /
    • v.15 no.5
    • /
    • pp.555-564
    • /
    • 2018
  • Allowing structures to uplift in earthquakes can significantly reduce or even avoid the development of plastic hinges within the structure. The permanent deformations in the structure can thus be minimized. However, uplift of footings can cause additional horizontal movements of a structure. With an increase in movement relative to adjacent structures, the probability of pounding between structures increases. This experimental study reveals that the footing mass can be used to control the vertical displacement of footing and thus reduce the horizontal displacements of an upliftable structure. A four storey model structure with plastic hinges and uplift capability was considered. Shake table tests using ten different earthquake records were conducted. Three different footing masses were considered. It is found that the amplitude of footing uplift can be greatly reduced by increasing the mass of the footing. As a result, allowing structural uplift does not necessary increase the horizontal displacement of the structure. The results show that with increasing footing weight, the interaction between structural and footing response can increase the contribution of the higher modes to the structural response. Consequently, the induced vibrations on secondary structure increase.

Development of high capacity stirling cryocooler

  • Ko, Junseok;Yeom, Hankil;Kim, Hyobong;Hong, Yong-Ju;In, Sehwan;Park, Seong-Je
    • Progress in Superconductivity and Cryogenics
    • /
    • v.17 no.3
    • /
    • pp.51-56
    • /
    • 2015
  • Cryogenic cooling system for HTS electric power devices requires a reliable and efficient high-capacity cryocooler. A Striling cryocooler with a linear compressor can be a good candidate. It has advantages of low vibration and long maintenance cycle compared with a kinematic-driven Stirling cryocooler. In this study, we developed dual-opposed linear compressor of 12 kW electric input power with two 6 kW linear motors. Electrical performance of fabricated linear compressor is verified by experimental measurement of thrust constant. The developed Stirling cryocooler has gamma-type configuration. Piston and displacer are supported with flexure spring. A slit-type heat exchanger is adopted for cold and warm-end, and the generated heat is rejected by cooling water. In cooling performance test, waveforms of voltage, current, displacement and pressure are obtained and their amplitude and phase difference are analysed. Moreover, temperatures of cooling water, housing and linear motor are recorded and electric power parameters of driving circuit are also obtained. The developed Stirling cryocooler reaches to 47.8 K within 23.4 min. with no-load. From heat load tests, it shows cooling capacity of 440 W at 78.1 K with 6.45 kW of electric input power and 19.4 of % Carnot COP.

Fatigue Strength Evaluation of Bogie Frame for Power Car (동력차용 대차프레임의 피로강도평가)

  • Lee, Hak-Ju;Han, Seung-U;Augagneur Sylvain;Lee, Sang-Rok
    • 연구논문집
    • /
    • s.27
    • /
    • pp.57-73
    • /
    • 1997
  • The bogie between the track and the railway vehicle body, is one of the most important component in railroad vehicle. Its effects on the safety of both passengers and vehicle itself, and on the overall performance of the vehicle such as riding quality, noise and vibration are critical. The bogie is mainly consisted of the bogie frame, suspensions, wheels and axles, braking system, and transmission system. The complex shapes of the bogie frame and the complicate loading condition (both static and dynamic) induced in real operation make it difficult to design the bogie frame fulfilling all the requirements. The complicated loads applied to the bogie frame are i) static load due to the weight of the vehicle and passengers, ii) quasi-static load due to the rolling in curves iii) dynamic load due to the relative motion between the track, bogie, and vehicle body. In designing the real bogie frame, fatigue analysis based on the above complicated loading conditions is a must. In this study, stress analysis of the bogie frame has been performed for the various loading conditions according to the UIC Code 6 15-4. Magnitudes of the stress amplitude and mean stress were estimated based on the stress analysis results to simulate the operating loads encountered in service. Fatigue strength of the bogie frame was evaluated by using the constant life diagram of the material. 3-D surface modelling, finite element meshing, and finite element analysis were performed by Pro-Engineer, MSC/PATRAN, and MSC/NASTRAN, respectively.

  • PDF

Finite Element Analysis for Time Response of a Flexible Spinning Disk with Translating Misalignment (회전축 정렬불량을 가지는 유연회전디스크의 유한요소법을 이용한 시간응답해석)

  • Heo, Jin-Uk;Jeong, Jin-Tae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.9
    • /
    • pp.1905-1913
    • /
    • 2002
  • Using the finite element method, this study investigates the dynamic time responses of a flexible spinning disk of which axis of rotation is misaligned with the axis of symmetry. The misalignment between the axes of symmetry and rotation is one of the major vibration sources in optical disk drives such as CD-ROM, CD-R, CD-RW and DVD drives. Based upon the Kirchhoff plate theory and the von-Karman strain theory, three coupled equations of motion for the misaligned disk are obtained: two of the equations are for the in-plane motion while the other is for the out-of-plane motion. After transforming these equations into two weak forms for the in-plane and out-of-plane motions, the weak forms are discretized by using newly defined annular sector finite elements. Applying the generalized-$\alpha$ time integration method to the discretized equations, the time responses and the displacement distributions are computed and then the effects of the misalign ment on the responses and the distributions are analyzed. The computation results show that the misalignment has an influence on the magnitudes of the in-plane displacements and it results in the amplitude modulation or the beat phenomenon in the time responses of the out-of-plane displacement.

Selection of Bearing Position for Improving Static and Dynamic Stiffness of 40,000rpm High-speed Spindle (40,000rpm 고속 주축의 정·동특성 향상을 위한 베어링 위치 선정)

  • Lim, Jeong Suk;Chung, Won Jee;Lee, Choon Man
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.8 no.1
    • /
    • pp.10-17
    • /
    • 2009
  • Spindle design is very important for the improvement of the competitive power in production cost of high quality machine tools. The important factor in spindle design is not only to improve the natural frequency of spindle but also to reduce displacement of spindle end. In this paper, parameters those influence on static and dynamic stiffness of high-speed spindle have selected form preceding studies. And those selected parameters are applied to Taguchi Method. To perform FEM analysis, bearing conditions are selected with optimized condition. To know how to improve static and dynamic stiffness of machine tool spindle, natural frequency and displacement of spindle end are obtained by FEM analysis. The Taguchi Method was used to draw optimized condition of bearing position and it's stiffness. From these results, amplitude of vibration is enough good less than $3{\mu}m$ pk-pk of the spindle of 40,000rpm manufactured in this work by the optimal design.

  • PDF

Field monitoring of wind effects on a super-tall building during typhoons

  • Zhi, Lunhai;Li, Q.S.;Wu, J.R.;Li, Z.N.
    • Wind and Structures
    • /
    • v.14 no.3
    • /
    • pp.253-283
    • /
    • 2011
  • This paper presents the field measurement results of wind effects on a super-tall building (CITIC Plaza, 391 m high) located in Guangzhou. The field data such as wind speed, wind direction and acceleration responses were simultaneously and continuously recorded from the tall building by a wind and vibration monitoring system during two typhoons. The typhoon-generated wind characteristics including turbulence intensity, gust factor, peak factor, turbulence integral length scale and power spectral density of fluctuating wind speed were presented and discussed. The dynamic characteristics of the tall building were determined based on the field measurements and compared with those calculated from a 3D finite element model of the building. The measured natural frequencies of the two fundamental sway modes of the building were found to be larger than those calculated. The damping ratios of the building were evaluated by the random decrement technique, which demonstrated amplitude-dependent characteristics. The field measured acceleration responses were compared with wind tunnel test results, which were found to be consistent with the model test data. Finally, the serviceability performance of the super-tall building was assessed based on the field measurement results.

Estimation of Group Walking Loads by System Identification of Building Structures (건축구조물의 시스템 식별을 통한 무리보행하중 평가)

  • 김태호;민경원;이동근
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.1
    • /
    • pp.65-72
    • /
    • 2003
  • The objective of this study is to estimate the frequency characteristics of group walking loads based on the information of measured responses. At first, dynamic properties such as natural frequencies and modes are obtained from input/output relation for building structures by heel drop test. Second, a method to estimate group walking loads by the transfer functions from measured responses to group walking loads is proposed. The method turned out to estimate the group walking loads accurately. Higher modes could be important in estimating the amplitude of group walking loads with the information of single walking load.

Influence of Design Parameters on Dynamic Behavior and Frequencies of Cantilever ripe Conveying Fluid (유체유동을 갖는 외팔 파이프의 동특성 및 진동수에 미치는 설계인자의 영향)

  • Yoon, Han-Ik;Son, In-Soo;Park, Il-Ju
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.11
    • /
    • pp.1815-1823
    • /
    • 2003
  • The vibrational system of this study consists of a cantilever pipe conveying fluid, the moving masses upon it and having an attached tip mass. The equation of motion is derived by using Lagrange's equation. The influences of the velocity and the inertia force of the moving mass and the velocities of fluid flow in the pipe have been studied on the dynamic behavior and the natural frequency of a cantilever pipe by numerical method. The deflection of the cantilever pipe conveying fluid is increased due to the tip mass and rotary Inertia. After the moving mass passed upon the cantilever pipe, the amplitude of pipe is influenced by energy variation when the moving mass fall from the cantilever pipe. As the moving mass increase, the frequency of the cantilever pipe conveying fluid is increased. The rotary inertia of the tip mass influences much on the higher frequencies and vibration mode.