• Title/Summary/Keyword: Vessel Level

Search Result 453, Processing Time 0.026 seconds

Clinicopathologic Characteristics in Node-negative Gastric Cancer Patients According to the Presence of Lymphatic Invasion

  • Choi, Ji-Yoon;Ha, Tae-Kyoung;Kwon, Sung-Joon
    • Journal of Gastric Cancer
    • /
    • v.10 no.2
    • /
    • pp.55-62
    • /
    • 2010
  • Purpose: We evaluated the clinicopathological charicterics and prognostic impacts of lymphatic vessel invasion in gastric cancer without lymph node involvement. Materials and Methods: Among 1,795 patients who underwent gastric surgery with gastric cancer at the department of surgery, Hanyang university college of medicine from June 1992 to March 2009, we retrospectively evaluated 890 patients with lymph node negative gastric cancer. Results: The lymphatic vessel invasion correlated significantly with tumor stage, age, tumor size, perineural invasion and operation method. The survival rates were only significantly different between the patients with and without lymphatic vessel invasion in patients with stage Ia (P=0.036). Univariate and multivariate analysis demonstrated that blood vessel invasion and preoperative serum CEA level were significant factor influencing the survival rate in lymph node negative gastric cancer patients with lymphatic invasion. Conclusions: In patients with lymph node negative gastric cancer, the survival rate is significantly lower in those with lymphatic vessel invasion than in those without. Especially, in patients with stage Ia gastric cancer, the survival rates is significantly different between those with and those without lymphatic vessel invasion. Blood vessel invasion and preoperative serum CEA level is an adverse prognostic indicator in patients with stage Ia gastric cancer with lymphatic invasion. Thus we should consider further adjuvant therapies in case of need and need to show more concern to identify gastric cancer patients early at risk for recurrence.

Micromorphological Structures of the Vessel Wall Sculptures in Korean Hardwoods (한국산 활엽수재 도관벽의 수식구조에 관한 연구)

  • Lee, Won-Yong;Lee, Sung-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.24 no.1
    • /
    • pp.54-67
    • /
    • 1996
  • Micromorphology of the vessel wall sculptures such as perforation plate, inter-vessel pits, vessel-ray pits, vessel-parenchyma pits, vestured pits, spiral thickening, and warts was observed in 78 species(45 genera, 25 families) of Korean hardwoods using a scanning electron microscopy. The SEM observation revealed the micromorphology of vessel wall sculptures which have not yet been described, and have confirmed findings already established at the light microscopical level.

  • PDF

Performance evaluation of 80 GHz FMCW Radar for level measurement of cryogenic fluid

  • Mun, J.M.;Lee, J.H.;Lee, S.C.;Sim, K.D.;Kim, S.H.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.23 no.4
    • /
    • pp.56-60
    • /
    • 2021
  • The microwave Radar used for special purposes in the past is being applied in various areas due to the technological advancement and cost reduction, and is particularly applied to autonomous driving in the automobile field. The FMCW (Frequency Modulated Continuous Wave) Radar can acquire level information of liquid in vessel based on the beat frequency obtained by continuously transmitting and receiving signals by modulating the frequency over time. However, for cryogenic fluids with small impedance differences between liquid medium and gas medium, such as liquid nitrogen and liquid hydrogen, it is difficult to apply a typical Radar-based level meter. In this study, we develop an 80 GHz FMCW Radar for level measurement of cryogenic fluids with small impedance differences between media and analyze its characteristics. Here, because of the low intrinsic impedance difference, most of the transmitted signal passes through the liquid nitrogen interface and is reflected at the bottom of the vessel. To solve this problem, a radar measurement algorithm was designed to detect multiple targets and separate the distance signal to the bottom of the vessel in order to estimate the precise position on the liquid nitrogen interface. Thereafter, performance verification experiments were performed according to the liquid nitrogen level using the developed radar level meter.

Nuclear reactor vessel water level prediction during severe accidents using deep neural networks

  • Koo, Young Do;An, Ye Ji;Kim, Chang-Hwoi;Na, Man Gyun
    • Nuclear Engineering and Technology
    • /
    • v.51 no.3
    • /
    • pp.723-730
    • /
    • 2019
  • Acquiring instrumentation signals generated from nuclear power plants (NPPs) is essential to maintain nuclear reactor integrity or to mitigate an abnormal state under normal operating conditions or severe accident circumstances. However, various safety-critical instrumentation signals from NPPs cannot be accurately measured on account of instrument degradation or failure under severe accident circumstances. Reactor vessel (RV) water level, which is an accident monitoring variable directly related to reactor cooling and prevention of core exposure, was predicted by applying a few signals to deep neural networks (DNNs) during severe accidents in NPPs. Signal data were obtained by simulating the postulated loss-of-coolant accidents at hot- and cold-legs, and steam generator tube rupture using modular accident analysis program code as actual NPP accidents rarely happen. To optimize the DNN model for RV water level prediction, a genetic algorithm was used to select the numbers of hidden layers and nodes. The proposed DNN model had a small root mean square error for RV water level prediction, and performed better than the cascaded fuzzy neural network model of the previous study. Consequently, the DNN model is considered to perform well enough to provide supporting information on the RV water level to operators.

APPLICATION OF UNCERTAINTY ANALYSIS TO MAAP4 ANALYSES FOR LEVEL 2 PRA PARAMETER IMPORTANCE DETERMINATION

  • Roberts, Kevin;Sanders, Robert
    • Nuclear Engineering and Technology
    • /
    • v.45 no.6
    • /
    • pp.767-790
    • /
    • 2013
  • MAAP4 is a computer code that can simulate the response of a light water reactor power plant during severe accident sequences, including actions taken as part of accident management. The code quantitatively predicts the evolution of a severe accident starting from full power conditions given a set of system faults and initiating events through events such as core melt, reactor vessel failure, and containment failure. Furthermore, models are included in the code to represent the actions that could mitigate the accident by in-vessel cooling, external cooling of the reactor pressure vessel, or cooling the debris in containment. A key element tied to using a code like MAAP4 is an uncertainty analysis. The purpose of this paper is to present a MAAP4 based analysis to examine the sensitivity of a key parameter, in this case hydrogen production, to a set of model parameters that are related to a Level 2 PRA analysis. The Level 2 analysis examines those sequences that result in core melting and subsequent reactor pressure vessel failure and its impact on the containment. This paper identifies individual contributors and MAAP4 model parameters that statistically influence hydrogen production. Hydrogen generation was chosen because of its direct relationship to oxidation. With greater oxidation, more heat is added to the core region and relocation (core slump) should occur faster. This, in theory, would lead to shorter failure times and subsequent "hotter" debris pool on the containment floor.

PWM-Based Sliding Mode Controller for Three-Level Full-Bridge DC-DC Converter that Eliminates Static Output Voltage Error

  • Liu, Jilong;Xiao, Fei;Ma, Weiming;Fan, Xuexin;Chen, Wei
    • Journal of Power Electronics
    • /
    • v.15 no.2
    • /
    • pp.378-388
    • /
    • 2015
  • This paper proposes a pulse width modulation (PWM)-based sliding mode controller (SMC) for a full-bridge DC-DC converter that can eliminate static output voltage error. Hysteretic SMC in DC-DC converter does not have a fixed switching frequency, and applying hysteretic SMC to full-bridge converters is difficult. Fixed-frequency SMC, which is also called PWM-based SMC, based on equivalent control overcomes these shortcomings. However, the controller order reduction in equivalent control in PWM-based SMC causes static output voltage error. To resolve this issue, an integral item is added to the PWM-based SMC. Sliding mode coefficients are designed by applying a standard second-order system to the sliding mode surface. The effect of adding an integral item on the controller is analyzed, and an integral coefficient design method is proposed. Experiment results on a three-level full-bridge DC-DC converter verify the control scheme and design method proposed in this paper.

Fishing efficiency of LED fishing lamp for squid jigging vessels (오징어 채낚기어선용 LED 집어등의 어획성능)

  • An, Young-Il
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.49 no.4
    • /
    • pp.385-394
    • /
    • 2013
  • This study has conducted a comparative analysis on the fishing efficiency of LED fishing lamps by squid jigging vessels, the Yeongrak-ho (16 tons) and Somang-ho (9.77 tons), which operated during September and October 2010 and during October 2011, comparing with MH (Metal Halide) fishing lamp-equipped fishing vessels. This study has also examined vessel's fuel consumption level. The light powers of LED fishing lamps of the Yeongrak-ho and Somang-ho were 25.8kW and 32kW, respectively. Those of the MH fishing vessels, that is, the MH fishing lamp-equipped fishing vessels, were 105kW and 81kW, respectively. The average squid catch in number of an LED vessel, Yeongrak-ho, was 39.2% of the MH fishing lamp-equipped fishing vessels; however, that of the Somang-ho improved to 78.7% of the MH fishing lamp-equipped vessels. Average catch in number by Yeongrak-ho crew was 2.6 times more than catch in number by automatic jigging machines. Average catch in number by MH fishing vessel crew was 1.8 times more than that by automatic jigging machines. An LED vessel, Yeongrak-ho's fishing rate was 17.5%~152.2% of the MH fishing vessels, that is, 61.1% on average, in comparison of combined catch in number per automatic jigging machine and per crewmember. Somang-ho's fishing rate was 6.7%~127.6% of the MH fishing vessels, that is, 73.1% on average. The average fuel consumption level of the Somang-ho, throughout its departure from to arrival at the port, was 475.7l, and that during fishing hours was 109.6l, or 23.0% of the total fuel consumption level. Somang-ho's fuel consumption level per fishing hour was 9.7l on average.

A study on the vessel traffic safety assessment of Busan Harbor (부산항내 선박통항 안전성 평가에 관한 연구)

  • KIM, Won-Ouk;KIM, Dae-Hee;KIM, Seok-Jae
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.53 no.4
    • /
    • pp.423-429
    • /
    • 2017
  • As invigoration plan of the marine tourism, Busan City has the plan to operate the cruise ship inside of the harbor, but the area has narrow water way with heavy traffic. As a result it is requested to evaluate the safety for the preparation of actual navigation. In this study, the Ship Handling Simulation (SHS) Assessment was conducted, which is regulated by the Maritime Traffic Safety Audit Scheme (MTSAS) in compliance with the Marine Safety Law and the Maritime Traffic Risk Assessment System based on the Electronic Chart Display and Information System (ECDIS). The proximity assessment, control assessment and subjective assessment were implemented, which is enacted by the Marine Safety Law by using the SHS. In the case of proximity assessment, the probability of trespass was not analyzed. As the control assessment, the swept path was measured at 11.7 m and 11.5 m for port entry and port departure respectively, which exceeded the width of the model vessel, 10.4 m over; it was considered as a marginal factor. As a result of the subjective evaluation of the navigator, there would be no difficulty on ship maneuvering by paying particular attention to the mooring vessel nearby the Busan Bridge and Yeongdo Bridge as well as the coming vessel from the invisible sea area when the vessel is entering and departing the port. The Marine Traffic Risk Assessment System analyzed as [Cautious] level until the vessel passed the Busan bridge and the curved area at 5 kts and it became to [Dangerous] level from where it left 75 m to the Busan Bridge. When the vessel passed the Busan Bridge and the curved area at 10 kts and entered the narrow area, it indicated the [Dangerous] level and became to [Very dangerous] level from where it left 410 m to the Busan bridge. In conclusion, the vessel should maintain at the speed of 5 kts to reduce the risk when it passes this area.

Natural Circulation Flow Investigation in a Rectangular Channel (사각 단면 채널에서의 자연순환 유동에 관한 연구)

  • Ha, Kwang-Soon;Kim, Jae-Cheol;Park, Rae-Joon;Kim, Sang-Baik;Hong, Seong-Wan
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3086-3091
    • /
    • 2007
  • When a molten corium is relocated in a lower head of a reactor vessel, the ERVC (External Reactor Vessel Cooling) system is actuated as coolant is supplied into a reactor cavity to remove a decay heat from the molten corium during a severe accident. To achieve this severe accident mitigation strategy, the two-phase natural circulation flow in the annular gap between the external reactor vessel and the insulation should be formed sufficiently by designing the coolant inlet/outlet area and gap size adequately on the insulation device. For this reason, one-dimensional natural circulation flow tests were conducted to estimate the natural circulation flow under the ERVC condition of APR1400. The experimental facility is one-dimensional and scaled-down as the half height and 1/238 rectangular channel area of the APR1400 reactor vessel. As the water inlet area increased, the natural circulation mass flow rate asymptotically increased, that is, it converged at a specific value. And the circulation mass flow rate also increased as the outlet area, injected air flow rate, and outlet height increased. But the circulation mass flow rate was not changed along with the external water level variation if the water level was higher than the outlet height.

  • PDF

The Structural Integrity Evaluation of Composite Pressure Vessel Using Acoustic Emission (음향방출을 이용한 복합재 압력용기의 건전성 평가)

  • 이상호;최용규
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.1 no.2
    • /
    • pp.1-11
    • /
    • 1997
  • During hydroproof test of composite pressure vessel, acoustic emission signal was measured and analyzed to evaluate structural integrity of composite motor case. When pressure was held for 1 min. at constant pressure from low pressure level to high pressure level, the pattern of hit rate of good composite pressure vessel is increased with higher value than that of bad composite pressure vessel. This report also presents detection possibility of burst location approximately in the range of 25∼36% of burst pressure using energy rate. In case that it is difficult to detect burst location of composite motor case, it is possible to detect burst location, i.e. structurally weak location of composite pressure vessel with applying same pressure lower than maximum expected operating pressure(MEOP) repeatedly.

  • PDF