• 제목/요약/키워드: Vessel Leak

검색결과 33건 처리시간 0.02초

음향방출 신호를 이용한 압력용기의 누설 검사기법 개발 (Leak Detection Technique of Pressure Vessel Using Acoustic Emission Signal)

  • 이성재;정연식;강명창;김정석
    • 한국공작기계학회논문집
    • /
    • 제13권4호
    • /
    • pp.95-99
    • /
    • 2004
  • In this study, the leak detection technique of pressure vessel by using acoustic emission(AE) signal is suggested experimentally. The leak of pressure vessel is located at the welding line due to welding defects. we measured the AE signal using Rl5I sensor, and examined the AE parameters in leak condition. It is investigated that the mean value of AE signal is dependent on leak source location. So the absolute mean value of AE signal is adopted as dominant AE parameter. We proposed leak detection algorithm using AE signal mean value for monitoring the leak source location.

회전하는 극저온 시스템의 단열 특성에 관한 실험적 연구 (Experimental of the Rotaing Cryogenic System)

  • 이창규;정상권
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제2권1호
    • /
    • pp.7-13
    • /
    • 2000
  • A rotating cryogenic system was designed similar to the cooling system for the rotor of a superconducting generator. The experimental rotor has an inner vessel which simulates the winding space of an actual superconducting rotor, and a torque tube of comparable design. This paper describes the evaluation of the total heat leak into the inner vessel that leads to the study of the heat transfer characteristic of the rotating cryogenic system. To examine the insulation performance of the experimental rotor. temperature was measured at each part of the system at various rotaing speeds from 0 rpm to 600 rpm. Total heat leak into the inner vessel was calculated by measuring the boil-off rate of liquid helium. Conduction heat leak to the inner vessel was obtained by the vent tube, and radiation heat leak was calculated by subtracting the conduction heat lent from the total heat leak. There seemed to be no rotaional dependency of total heat leak at least up 600 rpm.

  • PDF

적층단열재의 열침입량 측정 (Measurement of Heat Leak through Multi-Layer Insulation)

  • 김동락;양형석;정원묵;이병섭;신필권;황시돌
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제7권3호
    • /
    • pp.39-42
    • /
    • 2005
  • In this paper, the thermal characteristics of multilayer insulation (MLI) were experimentally investigated by using boil-off calorimetry method for seeking optimum standards of thermal insulation conditions. It is necessary to design the thermal insulating efficiency for applying to cryogenic instruments such as HTS power cable system. It is well known that the thermal characteristics and heat transfer of MLI are greatly affected by various MLI structures such as the number of layers and layer density, etc. However, it is difficult to know the thermal characteristics of MLI correctly. The heat leak by MLI between room temperature and liquid nitrogen temperature was measured at various conditions using a cylindrical cryostat. The cryostat consists of two guard vessels located at both end sides and a test vessel between them. The guard vessels are also filled with liquid nitrogen to prevent radiation heat leak through the both end side of the cylindrical test vessel to measure the heat leak only through MLI.

Commissioning result of the KSTAR in-vessel cryo-pump

  • Chang, Y.B.;Lee, H.J.;Park, Y.M.;Lee, Y.J.;Kwag, S.W.;Song, N.H.;Park, D.S.;Joo, J.J.;Moon, K.M.;Kim, N.W.;Yang, H.L.;Oh, Y.K.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제15권4호
    • /
    • pp.53-58
    • /
    • 2013
  • KSTAR in-vessel cryo-pump has been installed in the vacuum vessel top and bottom side with up-down symmetry for the better plasma density control in the D-shape H-mode. The cryogenic helium lines of the in-vessel cryo-pump are located at the vertical positions from the vacuum vessel torus center 2,000 mm. The inductive electrical potential has been optimized to reduce risk of electrical breakdown during plasma disruption. In-vessel cryo-pump consists of three parts of coaxial circular shape components; cryo-panel, thermal shield and particle shield. The cryo-panel is cooled down to below 4.5 K. The cryo-panel and thermal shields were made by Inconel 625 tube for higher mechanical strength. The thermal shields and their cooling tubes were annealed in air environment to improve the thermal radiation emissivity on the surface. Surface of cryo-panel was electro-polished to minimize the thermal radiation heat load. The in-vessel cryo-pump was pre-assembled on a test bed in 180 degree segment base. The leak test was carried out after the thermal shock between room temperature to $LN_2$ one before installing them into vacuum vessel. Two segments were welded together in the vacuum vessel and final leak test was performed after the thermal shock. Commissioning of the in-vessel cryo-pump was carried out using a temporary liquid helium supply system.

Simple predictive heat leakage estimation of static non-vacuum insulated cryogenic vessel

  • Mzad, Hocine
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제22권3호
    • /
    • pp.25-30
    • /
    • 2020
  • The diminishing of heat leak into cryogenic vessels can prolong the storage time of cryogenic liquid. With the storage of cryogenic liquid reducing, the heat leak decreases, while the actual storage time increases. Regarding to the theoretical analysis, the obtained results seems to be constructive for the cryogenic insulation system applications. This study presents a predictive assessment of heat leak occurring in non-vacuum tanks with a single layer of insulation. A Radial steady-state heat transfer, based on heat conduction equation, is taken into consideration. Graphical results show the thermal performance of the insulation used, they also allow us to choose the appropriate insulation thickness according to the shape and diameter of the storage tank.

COMPARISON OF THE DECAY HEAT REMOVAL SYSTEMS IN THE KALIMER-600 AND DSFR

  • Ha, Kwi-Seok;Jeong, Hae-Yong
    • Nuclear Engineering and Technology
    • /
    • 제44권5호
    • /
    • pp.535-542
    • /
    • 2012
  • A sodium-cooled demonstration fast reactor with the KALIMER-600 as a reference plant is under design by KAERI. The safety grade decay heat removal system (DHRS), which is important to mitigate design basis accidents, was changed in the reactor design. A loss of heat sink and a vessel leak in design basis accidents were simulated using the MARS-LMR system transient analysis code on two plant systems. In the analyses, the DHRS of KALIMER-600 had a weakness due to elevation of the overflow path for the DHRS operation, while it was proved that the DHRS of the demonstration reactor had superior heat transfer characteristics due to the simplified heat transfer mechanism.

회전하는 극저온 시스템의 단열 특성에 관한 실험적 연구 (Experimental investigation of the Rotating Cryogenic System)

  • 이창규;정상권
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2000년도 KIASC Conference 2000 / 2000년도 학술대회 논문집
    • /
    • pp.63-66
    • /
    • 2000
  • A rotating cryogenic system was designed similar to the cooling system for the rotor of a superconducting generator. The experimental rotor has an inner vessel which simulates the winding space of an actual superconducting rotor, and a torque tube of comparable design. This paper describes the evaluation of the total heat leak into the inner vessel that leads to the study of the jheat transfer characteristic of the rotating cryogenic system.

  • PDF

Total robotic right hepatectomy for multifocal hepatocellular carcinoma using vessel sealer

  • Peeyush Varshney;Vaibhav Kumar Varshney
    • 한국간담췌외과학회지
    • /
    • 제27권1호
    • /
    • pp.95-101
    • /
    • 2023
  • Rapid adoption of a robotic approach as a minimally invasive surgery tool has enabled surgeons to perform more complex hepatobiliary surgeries than conventional laparoscopic surgery. Although various types of liver resections have been performed robotically, parenchymal transection is challenging as commonly used instruments (Cavitron Ultrasonic Surgical Aspirator [CUSA] and Harmonic) lack articulation. Further, CUSA also requires a patient-side assistant surgeon with hepatobiliary laparoscopic skills. We present a case report of total robotic right hepatectomy for multifocal hepatocellular carcinoma in a 70-year-old male using 'Vessel Sealer' for parenchymal transection. Total operative time was 520 minutes with a blood loss of ~400 mL. There was no technical difficulty or instrument failure encountered during surgery. The patient was discharged on postoperative day five without any significant complications such as bile leak. Thus, Vessel Sealer, a fully articulating instrument intended to seal vessels and tissues up to 7 mm, can be a promising tool for parenchymal transection in a robotic surgery.

Assessment of Leak Detection Capability of CANDU 6 Annulus Gas System Using Moisture Injection Tests

  • Nho, Ki-Man;Kim, Wang-Bae;Sim, Woo-Gun
    • Nuclear Engineering and Technology
    • /
    • 제30권5호
    • /
    • pp.403-415
    • /
    • 1998
  • The CANDU 6 reactor assembly consists of an array of 380 pressure tubes, which are installed horizontally in a large cylindrical vessel, the Calandria, containing the low pressure heavy water moderator. The pressure tube is located inside the calandria tube and the annulus between these tubes, which forms a closed loop with $CO_2$ gas recirculating, is called the Annulus Gas System(AGS). It is designed to give an alarm to the operator even for a small pressure tube leak by a very sensitive dew point meter so that he can take a preventive action for the pressure tube rupture incident. To judge whether the operator action time is enough or not in the design of Wolsong 2,3 & 4, the Leak Before Break(LBB) assessment is required for the analysis of the pressure tube failure accident. In order to provide the required data for the LBB assessment of Wolsong Units 2, 3, 4, a series of leak detection capability tests was performed by injecting controlled rates of heavy water vapour. The data of increased dew point and rates of rise were measured to determine the alarm set point for the dew point rate of rise of Wolsong Unit 2. It was found that the response of the dew point depends on the moisture injection rate, $CO_2$ gas flow rate and the leak location. The test showed that CANDU 6 AGS can detect the very small leaks less than few g/hr and dew point rate of rise alarm can be the most reliable alarm signal to warn the operator. Considering the present results, the first response time of dew point to the AGS $CO_2$ flow rate is approximated.

  • PDF

웨이블릿 변환을 이용한 음향방출 신호의 처리기법 개선 및 위치표정 (Improvement of Acoustic Emission Signal Processing Method and Source Location using Wavelet Transform)

  • 김동현;박일서;정원용;박영석
    • 융합신호처리학회논문지
    • /
    • 제9권1호
    • /
    • pp.10-17
    • /
    • 2008
  • 본 논문은 설비진단에 있어 크랙 성장부터 누설에 이르기까지 결함으로 발생하는 AE 신호를 통하여 위치를 표정하여 진단 시스템의 오차를 줄이는 것이다. wavelet을 이용한 잡음 제거로서 위치표정의 개선을 제안하였고, 실험을 위한 신호원으로 알루미늄 평판에 샤프심 파단음을, 공기압축기의 누설음을 사용하였다. 신호원에 대하여 웨이블릿 Shrinkage방법과 Soft Threshold을 이용한 신호의 잡음제거 및 시간 도달차 법과 물성치를 적용한 속도 값으로 시뮬레이션을 통하여 위치표정 결과를 확인하였다. 그 결과 웨이블릿 변환을 이용한 잡음제거는 크랙실험의 경우 평균거리 10.46mm이하로 30% 이상과 누설 실험의 경우 평균필터에 비해 2%의 개선된 위치표정을 확인하였다.

  • PDF