• 제목/요약/키워드: Vertical-axis small wind turbine

검색결과 31건 처리시간 0.023초

Aerodynamic analysis and control mechanism design of cycloidal wind turbine adopting active control of blade motion

  • Hwang, In-Seong;Lee, Yun-Han;Kim, Seung-Jo
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제8권2호
    • /
    • pp.11-16
    • /
    • 2007
  • This paper describes the cycloidal wind turbine, which is a straight blade vertical axis wind turbine using the cycloidal blade system. Cycloidal blade system consists of several blades rotating about an axis in parallel direction. Each blade changes its pitch angle periodically. Cycloidal wind turbine is different from the previous turbines. The wind turbine operates with optimum rotating forces through active control of the blade to change pitch angle and phase angle according to the changes of wind direction and wind speed. Various numerical experiments were conducted to develop a small vertical axis wind turbine of 1 kW class. For this numerical analysis, the rotor system equips four blades consisting of a symmetric airfoil NACA0018 of 1.0m in span, 0.22m in chord and 1.0m in radius. A general purpose commercial CFD program, STAR-CD, was used for numerical analysis. PCL of MSC/PATRAN was used for efficient parametric auto mesh generation. Variables of wind speed, pitch angle, phase angle and rotating speed were set in the numerical experiments. The generated power was obtained according to the various combinations of these variables. Optimal pitch angle and phase angle of cycloidal blade system were obtained according to the change of the wind direction and the wind speed. Based on data obtained from the above analysis, control device was designed. The wind direction and the wind speed were sensed by a wind indicator and an anemometer. Each blades were actuated to optimal performance values by servo motors.

Experimental and Numerical Studies on the Possibility of Duct Flow Low-power Generation Using a Butterfly Wind Turbine

  • Hara, Yutaka;Kogo, Shohei;Takagaki, Katsuhiro;Kawanishi, Makoto;Sumi, Takahiro;Yoshida, Shigeo
    • International Journal of Fluid Machinery and Systems
    • /
    • 제10권1호
    • /
    • pp.19-29
    • /
    • 2017
  • An objective of this study is to demonstrate the validity of using a small wind turbine to recover the fluid energy flowing out of an exhaust duct for the generation of power. In these experiments, a butterfly wind turbine of a vertical axis type (D = 0.4 m) is used. The output performance is measured at various locations relative to the exit of a small wind tunnel (W = 0.65 m), representing the performance expected in an exhaust duct flow. Two-dimensional numerical analysis qualitatively agrees with the experimental results for the wind turbine power coefficient and rate of energy recovery. When the turbine is far from the duct exit (more than 2.5 D), an energy recovery rate of approximately 1.3% is obtained.

타워강성 효과를 고려한 소형 수직축 풍력발전기 운전 진동실험 및 해석 (Operational Vibration Experiment and Analysis of a Small Vertical-Axis Wind Turbine Considering the Effect of a Tower Stiffness)

  • 추헌호;심재박;오민우;김동현
    • 한국유체기계학회 논문집
    • /
    • 제16권3호
    • /
    • pp.5-9
    • /
    • 2013
  • In this study, operational vibration experiment and analysis have been conducted for the 4-blade small vertical-axis wind turbine (VAWT) including the effect of tower elastic behavior. Computational structural dynamics analysis method is applied to obtain Campbell diagram for the VAWT with elastic tower. An open type wind-tunnel is used to change and keep the wind velocity during the ground test. Equivalent elastic tower is used to support the VAWT so that the effect of elastic stiffness of the tower can be considered in the present vibration experiment. Various excitation conditions with wind loads are considered and the dominant operating vibration phenomena are physically investigated in detail.

10 kW급 수직축 풍력터빈에 대한 구조물 동적응답 계측 및 분석 (Dynamic Response Measurements and Analysis on a 10 kW Class Vertical Axis Wind Turbine)

  • 이진학;김원술;한택희;임승률
    • 한국소음진동공학회논문집
    • /
    • 제27권1호
    • /
    • pp.107-113
    • /
    • 2017
  • The dynamic characteristics including natural frequencies and excitation frequencies are evaluated for a small 10 kW vertical axis wind turbine. Acceleration responses were measured at 12 distributed locations for impact vibration tests, ambient vibration tests during non-operational and operational conditions, and braking tests during operational condition. The natural frequencies for the lowest 2 bending modes and the first torsional mode were estimated and also the excitation frequencies, i.e. 1P, 2P, 4P, were also estimated according to the rotational speed using the responses under operational conditions (i.e. power generation condition).

도시형 소형 수직축 풍력 발전기의 형태별 성능에 대한 실험적 고찰 (Experimental study on the performance of urban small vertical wind turbine with different types)

  • 강덕훈;신원식;이장호
    • 한국유체기계학회 논문집
    • /
    • 제17권6호
    • /
    • pp.64-68
    • /
    • 2014
  • This paper is intended to provide experimental data for the design of the small VAWT(vertical axis wind turbine). Three types(lift, drag, and hybrid) of the blade of VAWT are tested with digital wind tunnel in this study. From the test, the relation of power coefficient and tip speed ratio for the blades are evaluated and compared each other depending on the blade type. Especially, the characteristics of hybrid blade which is shown to be expanded in the market without any logical data is proposed in the relation of power coefficient and tip speed ratio. It is shown that the hybrid blade can be used to make higher starting torque with trade off of degradation of power coefficient.

반응표면법을 이용한 소형 수직축 풍력터빈 블레이드의 구조 최적화 (Structural Optimization for Small Scale Vertical-Axis Wind Turbine Blade using Response Surface Method)

  • 최찬웅;진지원;강기원
    • 한국유체기계학회 논문집
    • /
    • 제16권4호
    • /
    • pp.22-27
    • /
    • 2013
  • The purpose of this paper is to perform the structural design of the small scale vertical-axis wind turbine (VAWT) blade using a response surface method(RSM). First, the four design factors that have a strong influence on the structural response of blade were selected. Analysis conditions were calculated by using the central composite design(CCD), which is a typical design of experiment for the response surface method(RSM). Also, the significance of the central composite design(CCD) was verified using analysis of variance(ANOVA). The finite element analysis was performed for the selected analytical conditions for the application of response surface method(RSM). Finally, a optimization problem was solved with a objective function of blade weight and a constraint of allowable stress to achieve a optimal structural design of blade.

저속 회전형 소형 수직축 풍력발전기의 공기역학적 출력에 대한 CFD 및 실험적 검증 (CFD and experiment validation on aerodynamic power output of small VAWT with low tip speed ratio)

  • 허영근;최경호;김경천
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제40권4호
    • /
    • pp.330-335
    • /
    • 2016
  • 본 논문에서는 설계된 100 W급 헬리컬 수직축 풍력발전기의 공기 역학적 출력 및 유동 특성에 관하여 연구하였다. 이를 위하여 100 W급 헬리컬 수직축 풍력발전기 로터를 설계하였고 풍동 시험과 동일한 환경을 적용한 3차원 전산유동해석을 수행하였다. 전산유동해석 결과를 통하여 공기 역학적 출력과 헬리컬 유동 특성을 확인하였다. 마지막으로 실제 크기의 수직축 풍력발전기에 대한 풍동 시험을 수행하여 전산유동해석에서 예측한 공기역학적 출력과 비교 검증하여 전산유동해석 기법의 타당성을 확인하였다.

부유식 가변 피치형 수직축 풍력발전기의 발전효율에 관한 실험 연구 (Experimental Study on Efficiency of Floating Vertical Axis Wind Turbine with Variable-Pitch)

  • 김재희;조효제;황재혁;장민석;이병성
    • 한국해양공학회지
    • /
    • 제32권3호
    • /
    • pp.202-207
    • /
    • 2018
  • This paper presents the efficiency of a floating vertical axis wind turbine with variable-pitch. A model was designed to use the lift force and drag force for blades with various pitch angles. The blade's pitch angle is controlled by the stopper. To validate the efficiency of the wind turbine discussed in this paper, a model test was carried out through a single model efficiency experiment and wave tank experiment. The parameters of the single model efficiency experiment were the wind speed, electronic load, and pitch angle. The wave tank experiment was performed using the most efficient pitch angle from the results of the single model efficiency experiment. According to the results of the wave tank experiment, the surge and pitch motion of a structure slightly affect the efficiency of a wind turbine, but the heave motion has a large effect because the heights of the wind turbine and wind generator are almost the same.

풍력-태양광 복합 가로등 구조특성 연구 (Structural Characteristics for the Hybrid Street-Lamp of a Small Wind Turbine and Photovoltaic Power System)

  • 전현준;장춘만
    • 한국수소및신에너지학회논문집
    • /
    • 제24권6호
    • /
    • pp.566-572
    • /
    • 2013
  • In the present study, structure analysis has been performed to understand the deflection and stress distribution for a hybrid street-lamp having a vertical-axis wind turbine and a photovoltaic panel. Modal analysis is also evaluated to avoid resonance gerenerated by sychronism between a turbine and a lamppost. To analyze deflection, stress and frequency, general analysis code(ANSYS-Mechanical 13) is employed in the present work. Throughout structure analysis in the hybrid street-lamp, maximum stress is observed at the connecting position between a turbine blade and a blade supporter. Campbell diagram which is combined the natural frequency of turbine blades and blade passing frequency is presented to analyze a system resonance. It is found that the resonance of the system having a rotating turbine blade and a lamppost can avoid by the optimal selection of geometric parameters of a wind turbine.

소형 수직축 풍력발전기의 내진검증 해석 (Seismic Qualification Analysis of a Vertical-Axis Wind Turbine)

  • 최영휴;홍민기
    • 한국기계가공학회지
    • /
    • 제15권3호
    • /
    • pp.21-27
    • /
    • 2016
  • The static and dynamic structural integrity qualification was performed through the seismic analysis of a small-size Savonius-type vertical wind turbine at dead weight plus wind load and seismic loads. The ANSYS finite element program was used to develop the FEM model of the wind turbine and to accomplish static, modal, and dynamic frequency response analyses. The stress of the wind turbine structure for each wind load and dead weight was calculated and combined by taking the square root of the sum of the squares (SRSS) to obtain static stresses. Seismic response spectrum analysis was also carried out in the horizontal (X and Y) and vertical (Z) directions to determine the response stress distribution for the required response spectrum (RRS) at safe-shutdown earthquake with a 5% damping (SSE-5%) condition. The stress resulting from the seismic analysis in each of the three directions was combined with the SRSS to yield dynamic stresses. These static and dynamic stresses were summed by using the same SRSS. Finally, this total stress was compared with the allowable stress design, which was calculated based on the requirements of the KBC 2009, KS C IEC 61400-1, and KS C IEC 61400-2 codes.