• Title/Summary/Keyword: Vertical field

Search Result 1,682, Processing Time 0.03 seconds

The Horizontal Wind and Vertical Motion Field Derived from the NOAA Polar Orbiting Satellites

  • Lee, Dong-Kyou
    • 대한원격탐사학회지
    • /
    • 제4권1호
    • /
    • pp.41-47
    • /
    • 1988
  • The operational NOAA satellite temperature soundings are utilized to determine the horizontal wind and vertical motion fields for a polar low case over the East Asian region by solving the nonlinear balance equation and the omega equation. Preliminary results demonstrate that the balanced wind and vertical motion fields derived from the satellite data give reasonable synoptic patterns associated with the polar low. This encourages the use of satellite information as inputs in the numerical weather prediction models.

빠른 응답속도와 고광효율을 위한 새로운 수직배향 액정디바이스에 대한 연구 (Study on Novel Vertical Alignment liquid Crystal Device for Fast Response time and High Transmittance)

  • 조인영;김성민;김우일;김대현;권동원;손정호;류재진;김경현;이승희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 춘계학술대회 논문집
    • /
    • pp.59-60
    • /
    • 2009
  • The conventional in-plane field driven-vertical alignment display (VA-IPS) shows fast response time but transmittance shows very low and operating voltage is very high. In this paper, we studies electro-optical properties of the novel in-plane field driven vertical alignment device which has two transistors on array part and common electrode on CF substrate with dielectric layer. The device shows fast response time and high transmittance.

  • PDF

자연 산화막과 엑시머 레이저를 이용한 Poly-Si/a-Si 이중 박막 다결정 실리콘 박막 트랜지스터 (Poly-Si Thin Film Transistor with poly-Si/a-Si Double Active Layer Fabricated by Employing Native Oxide and Excimer Laser Annealing)

  • 박기찬;박진우;정상훈;한민구
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권1호
    • /
    • pp.24-29
    • /
    • 2000
  • We propose a simple method to control the crystallization depth of amorphous silicon (a-Si) deposited by PECVD or LPCVD during the excimer laser annealing (ELA). Employing the new method, we have formed poly-Si/a-Si double film and fabricated a new poly-Si TFT with vertical a-Si offsets between the poly-Si channel and the source/drain of TFT without any additional photo-lithography process. The maximum leakage current of the new poly-Si TFT decreased about 80% due to the highly resistive vertical a-Si offsets which reduce the peak electric field in drain depletion region and suppress electron-hole pair generation. In ON state, current flows spreading down through broad a-Si cross-section in the vertical a-Si offsets and the current density in the drain depletion region where large electric field is applied is reduced. The stability of poly-Si TFT has been improved noticeably by suppressing trap state generation in drain region which is caused by high current density and large electric field. For example, ON current of the new TFT decreased only 7% at a stress condition where ON current of conventional TFT decreased 89%.

  • PDF

연직드레인 공법에 의한 연약지반의 압밀거동 (Consolidation Behavior of Soft Ground by prefabricated Vertical Drains)

  • 이달원
    • 한국농공학회지
    • /
    • 제42권5호
    • /
    • pp.133-143
    • /
    • 2000
  • A large scale field test of prefabricated vertical drains was performed to anayze the effect of parameters of the very soft clay at a test site. compression index and the coefficient of horizontal consolidation obtained by back-analysis of settlement data were compared with those obtained by means of laboratory tests. Hyperbolic method, Asaoka meoth and curve fitting method were used to compute final settlement of coefficient of consolidation. The relationships of settlement measurement(Sm) versus design settlement(St) and the measurement consolidation ratio(Um) versus design consolidation (Ut) were shown as Sm=(1.0~1.1) St , Um=(1.13~1.17) Ut at 1.0m spacing of drain and Sm=(0.7~0.8)St, Um= (0.92~0.99) Ut at 1.5 m spacing of drain, respectively . The relationships of the field compression index(CcField) and virgin compression index(vcc lab) were shown as Ccfield =(1.0~1.2)vcc lab . But it was nearly within the same range when considering the error factor with the determination method of virgin compression index and the prediction back-analysis of the settlement data was larger than the coefficient of vertical consolidation, and the ratio of consolidation coefficient (Ch/Cv) was Ch =(2.4~2.9) Cv , Ch=(3.4~4.2) Cv at 1.0m and 1.5m spacing of drain, respectively.

  • PDF

Analysis of three-dimensional thermal gradients for arch bridge girders using long-term monitoring data

  • Zhou, Guang-Dong;Yi, Ting-Hua;Chen, Bin;Zhang, Huan
    • Smart Structures and Systems
    • /
    • 제15권2호
    • /
    • pp.469-488
    • /
    • 2015
  • Thermal loads, especially thermal gradients, have a considerable effect on the behaviors of large-scale bridges throughout their lifecycles. Bridge design specifications provide minimal guidance regarding thermal gradients for simple bridge girders and do not consider transversal thermal gradients in wide girder cross-sections. This paper investigates the three-dimensional thermal gradients of arch bridge girders by integrating long-term field monitoring data recorded by a structural health monitoring system, with emphasis on the vertical and transversal thermal gradients of wide concrete-steel composite girders. Based on field monitoring data for one year, the time-dependent characteristics of temperature and three-dimensional thermal gradients in girder cross-sections are explored. A statistical analysis of thermal gradients is conducted, and the probability density functions of transversal and vertical thermal gradients are estimated. The extreme thermal gradients are predicted with a specific return period by employing an extreme value analysis, and the profiles of the vertical thermal gradient are established for bridge design. The transversal and vertical thermal gradients are developed to help engineers understand the thermal behaviors of concrete-steel composite girders during their service periods.

수직형 순환유동층 열교환기에서의 유체유동과 온도장의 수치해석 (Numerical analysis of fluid flow and thermal fields in the vertical fluidized bed heat exchanger)

  • 이병창;강호근;이명성;안수환
    • 동력기계공학회지
    • /
    • 제16권4호
    • /
    • pp.24-29
    • /
    • 2012
  • The numerical analysis by using CFX 11.0 commercial code was done for prediction of fluid flow and thermal field in the vertical heat exchanger. The present experimental studies were also conducted to investigate the effects of circulating solid particles on the fluid flow and temperatures in the fluidized bed vertical shell and tube type heat exchanger with counterflow, at which the solid particles of glasses (3 $mm{\Phi}$) were used in the fluidized bed with a smooth tube. The effect of circulation on the distance(L) of tube inlet and baffle plate was also examined. The present experimental and numerical results showed that the particles in the distance (Ds) of 15 mm showed a more efficient circulation without stacked the space and the LMTD(Log Mean Temperature Difference) in the fluidized bed type was much lower than that in the typical type shell and tube heat exchanger.

Real-scale field testing for the applicability examination of an improved modular underground arch culvert with vertical walls

  • Tae-Yun Kwon;Jin-Hee Ahn;Hong-duk Moon;Kwang-Il Cho;Jungwon Huh
    • Advances in concrete construction
    • /
    • 제15권6호
    • /
    • pp.377-389
    • /
    • 2023
  • In this study, an improved modular arch system with the lower arch space composed of a precast arch block and an outrigger was proposed as an underground culvert, and its applicability and structural behaviors were confirmed. This modular arch culvert structure with vertical walls was designed using precast blocks and by adjusting the placement spacing of concrete blocks to the upper part form an arch shape and the lower part form a vertical wall shape, based on previously researched modular arch systems. Owing to the vertical wall of the proposed modular arch system, it is possible to secure a load-carrying capacity and an arch space that can sufficiently resist the earth pressure generated from the backfill soil and loading on the arch system. To verify the structural characteristics, and applicability of the proposed modular precast arch culvert structure, a full-scale modular culvert specimen was fabricated, and a loading test was conducted. By examining its construction process and loading test results, the applicability and constructability of the proposed structure were analyzed along with its structural characteristics. In addition, its the structural predictability and safety for the applicability were evaluated by comparing the construction process and loading test results with the FE analysis results.

ZnO 반도체 나노선의 패턴 성장 및 전계방출 특성 (Patterned Growth of ZnO Semiconducting Nanowires and its Field Emission Properties)

  • 이용구;박재환;최영진;박재관
    • 한국세라믹학회지
    • /
    • 제47권6호
    • /
    • pp.623-626
    • /
    • 2010
  • We synthesized ZnO nanowires patterned on Si substrate and investigated the field emission properties of the nanowires. Firstly, Au catalyst layers were fabricated on Si substrate by photo-lithography and lift-off process. The diameter of Au pattern was $50\;{\mu}m$ and the pattern was arrayed as $4{\times}4$. ZnO nanowires were grown on the Au catalyst pattern by the aid of Au liquid phase. The orientation of the ZnO nanowires was vertical on the whole. Sufficient brightness was obtained when the electric field was $5.4\;V/{\mu}m$ and the emission current was $5\;mA/cm^2$. The threshold electric field was $5.4\;V/{\mu}m$ in the $4{\times}4$ array of ZnO nanowires, which is quite lower than that of the nanowires grown on the flat Si substrate. The lower threshold electric field of the patterned ZnO nanowires could be attributed to their vertical orientation of the ZnO nanowires.

Frequency Response Estimation of 1.3 ㎛ Waveguide Integrated Vertical PIN Type Ge-on-Si Photodetector Based on the Analysis of Fringing Field in Intrinsic Region

  • Seo, Dongjun;Kwon, Won-Bae;Kim, Sung Chang;Park, Chang-Soo
    • Current Optics and Photonics
    • /
    • 제3권6호
    • /
    • pp.510-515
    • /
    • 2019
  • In this paper, we introduce a 1.3-㎛ 25-GHz waveguide-integrated vertical PIN type Ge-on-Si photodetector fabricated using a multi-project wafers service based on fringing field analysis in the depletion region. In general, 1.3-㎛ photodetectors fabricated using a commercial foundry service can achieve limited bandwidths because a significant amount of photo-generated carriers are located within a few microns from the input along the device length, and they are influenced by the fringing field, leading to a longer transit time. To estimate the response time, we calculate the fringing field in that region and the transit time using the drift velocity caused by the field. Finally, we compare the estimated value with the measured one. The photodetector fabricated has a bandwidth of 20.75 GHz at -1 V with an estimation error of <3 GHz and dark current and responsivity of 110 nA and 0.704 A/W, respectively.

CFD에 의한 입형 다단 원심펌프 유동특성에 관한 연구 (A Study on Flow Characteristics of Vertical Multi-stage Centrifugal Pump by CFD)

  • 모장오;남구만;김유택;이영호
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.402-407
    • /
    • 2002
  • A commercial CFD code is applied to analyze the 3-D viscous flow field within vertical multi-stage centrifugal pimp including impeller with 6 blades and guide vane with 11 blades and is performed by changing flow rate from 10 to $26\;m^3/h$ at the constant 3500rpm. The purpose of this 3-D numerical simulation is to confirm how much the effect of blade inlet angle of guide vane has an influence on the performance of vertical multi-stage centrifugal pimp. these results performed by $20^{\circ},\;30^{\circ}$ inlet angle of guide vane are compared with grundfos performance data. The vertical multi-stage pump consist of the impeller, guide vane, and cylinder. The characteristics such as total pressure coefficient total heat shaft horse power, power efficiency, discharge coefficient are represented according to flow rate changing.

  • PDF