• Title/Summary/Keyword: Vertical Well

Search Result 1,920, Processing Time 0.028 seconds

Evaluation of a Ground Heat Exchanger Appropriate for the Site of the Third Stage Construction of Incheon International Airport (인천국제공항 3단계 건설부지에 적합한 지중열교환기 시스템 평가 연구)

  • Cho, Nam-Hyun;Song, Jung-Tae;Yoon, Seok;Lee, Seung-Rae
    • Journal of the Korean Geotechnical Society
    • /
    • v.31 no.5
    • /
    • pp.23-33
    • /
    • 2015
  • In the present study, a ground heat exchanger was installed for each heat source in the system at the site to evaluate ground heat conductivity, constructability, and economic feasibility; the factors considered in the study included ground heat, groundwater, fillers (such as bentonite and pea pebbles) and the shape of the heat exchange pipe (e.g., U and D-U). The aim was to determine the ground heat exchanger appropriate for the geothermal system in the 3rd-phase construction of Incheon International Airport. A comparative cost analysis of the initial costs based on the above information showed that although the initial costs of the regular vertical closed loop-II and modified vertical closed loop were lower than those of the regular vertical closed loop-I, they could not be expected to deliver high economic efficiency from the viewpoint of constructability (filler injection, heat exchange pipe insertion). The initial costs proved to be higher in the case of Geohil.

Effects of implant tilting and the loading direction on the displacement and micromotion of immediately loaded implants: an in vitro experiment and finite element analysis

  • Sugiura, Tsutomu;Yamamoto, Kazuhiko;Horita, Satoshi;Murakami, Kazuhiro;Tsutsumi, Sadami;Kirita, Tadaaki
    • Journal of Periodontal and Implant Science
    • /
    • v.47 no.4
    • /
    • pp.251-262
    • /
    • 2017
  • Purpose: The purpose of this study was to investigate the effects of implant tilting and the loading direction on the displacement and micromotion (relative displacement between the implant and bone) of immediately loaded implants by in vitro experiments and finite element analysis (FEA). Methods: Six artificial bone blocks were prepared. Six screw-type implants with a length of 10 mm and diameter of 4.3 mm were placed, with 3 positioned axially and 3 tilted. The tilted implants were $30^{\circ}$ distally inclined to the axial implants. Vertical and mesiodistal oblique ($45^{\circ}$ angle) loads of 200 N were applied to the top of the abutment, and the abutment displacement was recorded. Nonlinear finite element models simulating the in vitro experiment were constructed, and the abutment displacement and micromotion were calculated. The data on the abutment displacement from in vitro experiments and FEA were compared, and the validity of the finite element model was evaluated. Results: The abutment displacement was greater under oblique loading than under axial loading and greater for the tilted implants than for the axial implants. The in vitro and FEA results showed satisfactory consistency. The maximum micromotion was 2.8- to 4.1-fold higher under oblique loading than under vertical loading. The maximum micromotion values in the axial and tilted implants were very close under vertical loading. However, in the tilted implant model, the maximum micromotion was 38.7% less than in the axial implant model under oblique loading. The relationship between abutment displacement and micromotion varied according to the loading direction (vertical or oblique) as well as the implant insertion angle (axial or tilted). Conclusions: Tilted implants may have a lower maximum extent of micromotion than axial implants under mesiodistal oblique loading. The maximum micromotion values were strongly influenced by the loading direction. The maximum micromotion values did not reflect the abutment displacement values.

Hospital Employees' Conflict and Attitude Toward Patients (병원직원의 갈등과 환자에 대한 태도)

  • Shin, Jum-Soon;Park, Jae-Yong;Kam, Sin;Joo, Ree
    • Korea Journal of Hospital Management
    • /
    • v.2 no.1
    • /
    • pp.114-136
    • /
    • 1997
  • This study was carried out to find out the effect of conflict between profession groups within medical institution. For the purpose, the questionnaire-based research was done with 605 persons consisting of specialists, residents, nurses, radiologic technicians, clinicopatholigic technicians, health record administrator, administrative employees who are working in a university hospital located in Taegu City from February 15, 1997 to March 2, 1997. The results of the study were summarized as follows. The subject profession group against which each profession group feels the most conflict in interprofession mutual recognition relation was found out as follows; Specialists(34%) against colleague specialists, residents(54.0%) against nurses, nurses(54.8%) against residents, radiologic technicians(44.0%) against residents, and clinicopathologic technicians(34.5%) against nurses, while it was shown that health record administrator felt even conflict against residents, nurses and administrative employees and administrative employees(48.1) did against nurses. Most employee group answered that medical specialists have a one-sided and individual attitude toward all affairs, while both medical specialists and administrative employees of hospital answered that nurses are one-sided. It was shown among such groups that radiologic technicians' conflict results from their thinking which mutual dependence and cooperation are lowest while individual difference is highest, clinicopatholigic technicians' conflict from the problem in mutual communication, medical specialists' conflict from difference in goals greater than other group, respectively lower than other group. The rate of vertical conflict between groups was highest for the health record administrators and then for the radiological technicians, while it was lowest for the medical specialists and then for the nurses. In addition, the rate of horizontal conflict was high for both medical specialists and nurses, but it was low for the health record administrations and clinicopathological technicians. The group with the highest job satisfaction was the medical specialists and nurses, and the group with the highest involvement in organization was the medical specialists and administrative employees. Also it was shown that both medical specialists and clinicopathological technicians show a favorable attitude toward patients. Factors having an effect on the vertical conflict included difference in goals, cooperation within group and leadership. It was shown among those factors, however, that only the leadership has an effect on all the groups evenly. The horizontal conflict was influenced by such factors as educational level, mutual dependence, difference in goals, cooperation within group, and individual difference, when an important factor was the difference in goals for all the groups. Their attitude toward patients was influenced by the vertical conflict and age, but the vertical conflict was the most significant factor for the medical specialists. In conclusion, it is required to control properly the conflict between employees as well as between profession group and to execute good leadership, so as to improve patients' satisfaction which is the key goal of hospital.

  • PDF

FINITE ELEMENT ANALYSIS OF MANDIBULAR STRESSES AND DENTURE MOVEMENTS INDUCED BY OVERDENTURES (Overdenture 하에서 하악응력 및 의치의 변위에 관한 유한요소법적 분석)

  • Kim, Joung-Hee;Chung, Chae-Heon;Cho, Kyu-Zong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.28 no.1
    • /
    • pp.63-94
    • /
    • 1990
  • The purpose of this study was to analyze the displacement and the magnitude and the mode of distribution of the stresses in the lower overdenture, the mucous membrane, the abutment tooth and the mandibular supporting bone when various denture base materials, such as acrylic resin and 0.5mm metal base, and various denture base designs were subjected to different loading schemes. For this study, the two-dimensional finite element method was used. Mandibular arch models, with only canine remaining, were fabricated. In the first denture base design, a space, approximately 1mm thick, was prepared between the denture and the dome abutment. In the second denture base design, contact between the denture and the dome abutment was eliminated except the contact of the occlusal third of the abutment. In order to represent the same physiological condition as the fixed areas of the mandible under loading schemes, the eight nodes which lie at the mandibular angle region, the coronoid process and the mandibular condyle were assumed to be fixed. Each model was loaded with a magnitude of 10 kgs on the first molar region(P1) and 7 kgs on the central incisal region (P2) in a vertical direction. Then the force of 10 kgs was applied distributively from the first premolar to the second molar of each model in a vertical direction(P3). The results were as follows. : 1. When the testing vertical loads were given to the selected points of the overdenture, the overdenture showed the rotatory phenomenon, as well as sinking and the displacements of alveolar ridge, abutment and lower border of mandible under the metal base overdenture were less than those under the acrylic resin overdenture. 2. The maximum principal stresses(the maximum tensile stresses) being considered, high tensile stresses occured at the buccal shelf area, the posterior region of the ridge crest and the anterior border region of the mandibular ramus. 3. The minimum principal stresses(the maximum compressive stresses) being considered, high compressive stresses occured at the inferior and posterior border region of the mandible, the mandibular angle and the posterior border region of the mandibular ramus. 4. The vertical load on the central incisal region(P2) produced higher equivalent stress in the mandible than that on any other region(P1, P3) because of the long lever arm distance from the fixed points to the loading point. 5. Higher equivalent stresses were distributed throughout the metal base overdenture than the resin base overdenture under the same loading condition. 6. The case of occlusal third contact of the abutment to the denture produced higher equivalent stresses in the abutment, the mandibular area around the abutment and the overdenture than the case of a 1mm space between the denture and the abutment. 7. Without regard to overdenture base materials and designs, the amounts and distribution patterns of equivalent stresses under the same loading condition were similar in the mucous membrane.

  • PDF

Network Interface Selection Algorithm on Vertical Handoff between 3G Networks and WLANs (3G 네트워크와 무선랜 사이 계층적 핸드오프의 네트워크 인터페이스 선택 알고리즘)

  • Seok Yongho;Choi Nafiung;Choi Yanghee
    • Journal of KIISE:Information Networking
    • /
    • v.32 no.2
    • /
    • pp.203-214
    • /
    • 2005
  • The integration of 3G networks and WLANs as complementary has been begun to attract much attention in industry as well as academia. This topic is becoming a burning issue, and one of the key questions which it raises is how to support a seamless vertical handoff. This paper introduces a new network interface selection algorithm for energy-efficient vertical handoff in tightly coupled systems capable of supporting seamless handoff. Our proposed scheme, Wise Interface Selection (WISE) switches the active network interface, after taking into consideration the characteristics of the network interface cards and the current level of data traffic, with the cooperation of the mobile terminals and network. Network interface switching operates independently on both the downlink and the uplink for the purpose of energy conservation. We show through simulation that less energy is consumed with WISE than when only a 3G network or WLAN interface is used, resulting in a longer lifetime for the mobile terminals. In the case of TCP connections, additional throughput gain can also be obtained.

Numerical Analysis on the Determination of Head Loss by Perforated Vertical Walls (연직 유공벽의 수두손실 결정을 위한 수치해석)

  • Chun, In-Sik;Lee, Seong-Yeop;Park, Kyung-Soo;An, Dong-Keun
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.19 no.3
    • /
    • pp.194-204
    • /
    • 2007
  • A numerical analysis and hydraulic experiments were undertaken to investigate the head loss occurring when a flow passes through vertical perforated walls. The numerical analysis applied continuity, momentum and energy equations to the control volumes that were set near the perforated wall. Non-dimensional equations were then derived to calculate both upstream depth and head loss for the given values of downstream depth and velocity. The hydraulic experiments were performed with several single and triple perforated plates varying their opening ratios and intervals. The numerical results with the single plates were compared with the experimental results, and it was shown that the contraction coefficient of the vertical line jet formed after the perforated plates relies on downstream Froude number as well as opening ratio. Based on the experimental results, empirical formulas were formulated. Finally, the formulas were applied to the triple plates sequentially from downstream side to upstream side, and it was found that in general the predicted values nicely agreed with the experimental results.

Evaluation of Required Discharge Capacity of PVD with Various Core Types (코어형태에 따른 연직배수재의 소요통수능력평가)

  • Shin, Eun-Chul;Kim, Sung-Hwan;Kang, Jeong-Gu
    • Journal of the Korean Geosynthetics Society
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 2007
  • Recently, the demand for industrial and residental land are increasing with economic growth, but it is difficult to acquire areas for development with good ground condition. For efficient and balanced development of land, new development projects are being carried out not only the areas with inland but those with the soft ground as well. As soft grounds have complex engineering properties and high variations such as ground subsidence especially when their strength is low and depth is deep, we need to accurately analyze the engineering properties of soft grounds and find general measures for stable and economic design and management. Vertical drain technology is widely used to accelerate the consolidation of soft clay deposits & dredged soil under pre-loading and various types of vertical drain are used with there discharge capacity. Under field conditions, discharge capacity is changed with various reason, such as soil condition, confinement pressure, long-term clogging and folding of vertical drains and so on. Therefore, many researcher and engineer recommend the use of required discharge capacity. In this paper, the experiment study were carried out to obtain the discharge capacity of four different types of vertical drains by utilizing the large-scale model tests and the required discharge capacity was calculated by several methods.

  • PDF

Acoustic Scattering Layers in the East China Sea ( 2 ) -Vertical Distribution of Volume Scattering Strength- (동지나해의 초음파 산란층에 관한 연구 ( 2 ) -체적산란강도의 연직분포-)

  • 이대재
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.26 no.1
    • /
    • pp.20-25
    • /
    • 1990
  • During the summer of 1989, the authors carried out the hydroacoustic surverys to investigate the vertical distribution of volume backscattering strength in the East China Sea and simultaneously the biological sampling of the scattering layers by bottom trawling. The echoes from the scattering layers was continuously measured by using a 50 kHz echo sounder during the day and night. A data acquisition system was used to record digitally the envelope of the echoes and the echo integration technique was used to determine the scattering strength proportional to biomass density in each layer. The vertical profiles of volume backscattering strength also were compared with the one of water temperature. The results obtained can be summarized as follows: 1. The vertical profiles of mean volume backscattering strength at day and night suggested that during the night the biggest fish concentrations appeared in the mixed layer above the thermocline and during the day near the bottom. In another profiles where the thermocline was not well developed, peaks in scattering appeared at midwater depths and near the bottom. 2. The maximum values of mean volume backscattering strengths varied from -49.3 dB to -48.0 dB on different regions and at different times of the day and night. 3. Trawl data indicated that the organisms consisting of the scattering layer near the bottom were squid and various species of demersal fishes.

  • PDF

An Experimental Study on Fire Spreading External Wall of Buildings Using Dry Construction Method (건식공법을 이용한 건축물의 외벽 화재 확산의 실험적 연구)

  • Park, Jung-Woo;Cho, Nam-Wook
    • Fire Science and Engineering
    • /
    • v.32 no.4
    • /
    • pp.75-85
    • /
    • 2018
  • The Grenpell tower fire in England in June of 2016 is a representative example of damage caused by a vertical fire spreading through external insulation. Organic insulation materials, which are widely used in external insulation, have the disadvantage that they have good insulation performance but are vulnerable to fire. Aluminum composite panels are used as exterior wall finishing materials, and plastics used in aluminum are regarded as the cause of vertical fire spread. Due to the steel frame used to secure the aluminum composite panel to the outer wall, a cavity is formed between the outer wall and outer wall finish. When a fire occurs on the outer wall, the flammable outer wall as well as the flame generated from the heat-insulating material spreads vertically through the cavity, resulting in damage to people and property. In Korea, material unit performance tests are carried out by the Ministry of Land, Infrastructure and Transport notice 2015 - 744. However, in the UK, the BS 8414 test is used to measure the vertical fire spreading time on the outer wall in real scale fire tests. In this study, the risk of external wall fire was evaluated in an actual fire by conducting a real scale wall fire test (BS 8414), which was carried out in Europe, using aluminum composite panels of semi-noncombustible materials suitable for current domestic standards. The purpose of this study was to confirm the limitations of material unit evaluation of finishing materials and to confirm the necessity of introducing a system to prevent the spread of outer wall fire through an actual scale fire test.

Synthesis of High-Quality Single-Walled Carbon Nanotube Fibers by Vertical CVD (수직 가열로를 이용한 고순도 단일벽 탄소나노튜브 섬유의 합성)

  • Kim, Tae-Min;Song, Woo-Seok;Kim, Yoo-Seok;Kim, Soo-Youn;Choi, Won-Chel;Park, Chong-Yun
    • Journal of the Korean Vacuum Society
    • /
    • v.19 no.5
    • /
    • pp.377-384
    • /
    • 2010
  • Many routes have been developed for the synthesis of signle-walled carbon nanotubes (SWCNTs). We spun fibers of SWCNTs directly from vertical furnace using a liquid source of carbon and an iron-contained molecule. The solution was prepared by ethanol as a carbon source, in which ferrocene as a catalyst, thiophene were dissolved. It was then injected from the top of the furnace into hot zone with hydrogen as a carrier gas. We successfully synthesized high-quality SWCNTs by adjusting the various experimental conditions, such as concentration of ferrocene, solution injection rate, concentration of thiophene, and hydrogen flow rate. Measurement of Raman spectroscopy, scanning electron microscopy, and transmission electron microscopy were carried out to find the optimized conditions. The synthesized SWCNTs (1.16~1.64 nm) appeared a bundle structure and well-aligned parallel to the direction of furnace. These results also provide an simple way for high-quality SWCNTs mass production and fabricating direct spining SWCNTs fiber. It will allow one-step production of SWCNTs fiber with potentially excellent properties and wide-range applications.