• 제목/요약/키워드: Vertical Thermal Distribution

검색결과 111건 처리시간 0.026초

The Condition Assessment of Cast Resin Molded Transformer Windings Using Vertical Analysis of Thermal Distribution

  • Lim Young-Bae;Jung Jong-Wook;Jung Jin-Soo;Cho Seong won;Kim Joon-Bum
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제5C권5호
    • /
    • pp.191-195
    • /
    • 2005
  • This paper presents an assessment method in integrity of the windings in cast resin molded transformers by using vertical analysis of thermal distribution. The proposed method is to compare the temperature distribution in a sound specimen with that in the faulted specimen with a layer to layer short circuit. Temperature distribution was acquired by an infrared thermography system, and the Arrhenius equation was adopted to the accelerated test. The proposed method can be used to detect the failures in the transformers.

수직온도분포 분석을 이용한 몰드변압기 권선의 건전성 평가 연구 (A Study on the Integrity Evaluation of the Windings in Cast Resin Transformers Using Vertical Thermal Distribution Analysis)

  • 김홍래;임용배
    • 조명전기설비학회논문지
    • /
    • 제19권2호
    • /
    • pp.94-99
    • /
    • 2005
  • 본 논문은 수직온도분포 분석을 이용한 몰드변압기 권선의 건전성 평가 방법을 제시하고 있다. 이 방법은 건전 시료의 온도 분포와 가속열화실험에 의해 층간 단락된 고장시료의 온도 분포 비교를 통해 얻어진 결과이다. 분석에 활용된 온도분포는 적외선 열화상 시스템에 의해 취득되었고, 가속 열화시험에는 Arrhenius 방정식이 적용되었다. 제안된 방법은 몰드변압기 고장을 검출하는데 유용할 것이다.

대공간의 실내온열환경 실측 및 분석 (The Field Measurement and Analysis of Indoor Thermal Environment in Large Enclosures)

  • 채문병;양정훈;최동호;석호태
    • 한국공간구조학회논문집
    • /
    • 제8권1호
    • /
    • pp.77-88
    • /
    • 2008
  • 본 연구에서는 대공간을 동계 및 하계로 구분하여 실내온열환경의 변화를 실측하고 냉 난방조건과 관련하여 대공간에서 형성되는 실내온열환경의 특성을 파악하는 것을 목적으로 하여, 대공간의 수직 및 수평온도분포, 객석온도분포, 실내표면온도분포, 실내온열쾌적성 등의 실내온열환경을 검토하였다.

  • PDF

아트리움의 수직온도 분포해석 프로그램의 개발에 관한 연구 (A study on the Development of Vertical Air Temperature Distribution Model in Atrium)

  • 김용인;조균형;김광우
    • 태양에너지
    • /
    • 제17권3호
    • /
    • pp.3-11
    • /
    • 1997
  • Recently the construction of atrium buildings has increased but along with it many problems in thermal environment have arised. since the exterior wall of glass, indoor temperature is greatly influenced by weather conditions and since the space volume is very large, the vertical air temperature is not uniform. So, in this study, a Vertical Temperature Distribution Model was developed to predict the vertical air temperature of an atrium and evaluate the effects of the design parameters on the air temperature distribution of an atrium. To consider the characteristics of the vertical air temperature distribution in an atrium, the Satosh Togari's Macroscopic Model was used basically for the calculation of the vertical air temperature distribution in large space and the solar radiation analysis model and natural ventilation analysis model in atrium. And to calculate the unsteady-state inside wall surface temperature(boundary condition), the finite difference method was used. For the verification of the developed temperature distribution program, numerical evaluation of air flow by the ${\kappa}-{\varepsilon}$ turbulence model and in-situ test was conducted in parallel. The results of this study, the developed temperature distribution program was seen to predict the thermal condition of the atrium very accurately.

  • PDF

수직온도분포 분석을 이용한 몰드변압기 권선의 건전성 평가 연구 (A Study on the Integrity Evaluation of the Windings in Cast Resin Transformers Using Vertical Thermal Distribution Analysis)

  • 임용배
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 학술대회 논문집
    • /
    • pp.315-319
    • /
    • 2004
  • This paper presents the integrity evaluation method of the windings in cast resin transformers using vertical thermal distribution analysis. The method is to compare the temperature distribution in a sound condition specimen with that in the failure condition specimen layer-shorted by accelerated testing. The temperature distribution was acquisited by a infrared thermography system, and the Arrhenius equation was adopted to the accelerated testing. The proposed method may be available to detect the failures in cast resin transformers.

  • PDF

온돌난방주택의 난방방식별 열 특성에 관한 실험연구 (Experimental Study on the Thermal Characteristics in Ondol Heating Systems)

  • 윤정숙
    • 한국주거학회논문집
    • /
    • 제1권1호
    • /
    • pp.91-102
    • /
    • 1990
  • The aim of this study is to discover thermal characteristics of Ondol heating systems. The housing subjected was categorized into detached single family houses and apartments, reinforced concrete and brick structures, intermittent and continous heating system, and the space subjected was bedroom. In order to understand the thermal characteristics of each floor heating systems, the vertical distribution of indoor temperature and the distribution of surface temperature on the floor were measured. The vertical distribution of indoor temperature except the measurement point 1 largely showed average temperature distribution, and the temperature of the measurement point 1 in the housing surveyed showed the highest temperature in the house "sample A" because of the radiation heating from the floor of the Ondol room. As the result of the measurement, the thermal characteristics of each heating system were more stable distribution in apartments of R.C structure.structure.

  • PDF

Patterns of Vertical Distribution and Diel Vertical Migration of Zooplankton in the East Sea of Korea (Sea of Japan)

  • Park, Chul;Lee, Chang-Rae;Hong, Sung-Yun
    • Journal of the korean society of oceanography
    • /
    • 제32권1호
    • /
    • pp.38-45
    • /
    • 1997
  • To find out the changes in vertical distribution patterns over the 24-h period, a key and the first step to tackle the problem of adaptive significance of diel vertical migration (DVM), vertically stratified time series samplings with multiple opening/closing plankton samplers were done in the East Sea of Korea (Sea of Japan). Sampling was done almost every 4 h for one day period following the same water parcel in Nov. 1995 and May 1996, respectively. Resultant patterns of vertical distribution showed that some species such as most abundant taxa Metridia pacifica and Scolecithyicella minor, both Copepoda, performed DVM even in the study area of strong thermal stratification. Their patterns of DVM such as distance scales and timing of movements were not the same each other, and they were separated from other taxa in the dendrogram obtained by the cluster analyses, Most minor taxa grouped in one, however, seemed not to do DVM in the study area of strong thermal stratification. They usually preferred the warmer surface layer where the foods were probably more abundant.

  • PDF

실측을 통한 대규모 실내경기장의 온열환경 분석에 관한 연구 (A Study on the Analysis of Indoor Thermal Environment in Large Enclosure through Actual Measurement)

  • 채문병;양정훈;최동호;석호태
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.3-8
    • /
    • 2007
  • The purpose of this study is to grasp the characteristic of indoor thermal environment from large enclosures in connection with heating and cooling condition. This study has measured indoor thermal environment in winter and summer season. We examined indoor thermal environment of the large enclosures in this study which include vertical, horizontal temperature distribution and thermal comfort environment.

  • PDF

수직형 건식 진공 스크류 펌프의 열특성에 대한 연구 (A Study on the Thermal Characteristics of Dry Vacuum Pump with Vertical Screws)

  • 장문석;박재현;김수태;김일곤;조성진
    • 한국기계가공학회지
    • /
    • 제14권2호
    • /
    • pp.67-74
    • /
    • 2015
  • In this study, analysis and experiments were carried out on temperature distributions and thermal deformations in a dry vacuum pump with vertical screws for safe operation. When a vacuum pump is working, it is necessary to get rid of the heat generated by the friction of bearings and the compression of air to prevent the vacuum pump from being damaged by interference between two screws and housing through thermal deformation. Additional cooling was proposed by using oil flow through the inner channel of the rotating axis for lower temperature control of the vacuum pump. Analysis and experimental results were compared in terms of temperature distribution and thermal deformation of the vacuum pump, and two sets of results matched reasonably well. These results for a dry vacuum pump with vertical screws can be used in similar model development and can minimize errors in design and manufacture by providing reasonably accurate prediction in advance.

Thermal radiation and some physical combined effects on an asymmetric peristaltically vertical channel of nanofluid flow

  • Amira S. Awaad;Zakaria M. Gharsseldien
    • Advances in nano research
    • /
    • 제16권6호
    • /
    • pp.579-591
    • /
    • 2024
  • This study explained the effects of radiation, magnetic field, and nanoparticle shape on the peristaltic flow of an Upper-Convected Maxwell nanofluid through a porous medium in an asymmetric channel for a better understanding of cooling and heating mechanisms in the presence of magnetic fields. These phenomena are modeled mathematically as a system of non-linear differential equations, that are solved under long-wavelength approximation and low Reynolds number conditions using the perturbation method. The results for nanofluid and temperature described the behavior of the pumping characteristics during their interaction with (the vertical position, thermal radiation, the shape of the nanoparticle, and the magnetic field) analytically and explained graphically. Also, the combined effects of thermal radiation parameters and some physical parameters on pressure rise, pressure gradient, velocity, and heat distribution are pointed out. Qualitatively, a reverse velocity appears with combined high radiation and Grashof number or combined high radiation and low volume flow rate. At high radiation, the spherical nanoparticle shape has the greatest effect on heat distribution.