• Title/Summary/Keyword: Vertical Plate

Search Result 772, Processing Time 0.033 seconds

High-resolution Seismic Imaging of Shallow Geology Offshore of the Korean Peninsula: Offshore Uljin (신기 지구조운동의 해석을 위한 한반도 근해 천부지질의 고해상 탄성파 탐사: 울진 주변해역)

  • Kim, Han-Joon;Jou, Hyeong-Tae;Yoo, Hai-Soo;Kim, Kwang-Hee;You, Lee-Sun
    • Geophysics and Geophysical Exploration
    • /
    • v.14 no.2
    • /
    • pp.127-132
    • /
    • 2011
  • We acquired and interpreted more than 650 km of high-resolution seismic reflection profiles in the Hupo Basin, offshore east coast of Korea at $37^{\circ}N$ in the East Sea (Japan Sea) to image shallow and basement deformation. The seismic profiles reveal that the main depocenter of the Hupo Basin in the study area is bounded by the large offset Hupo Fault on the east and an antithetic fault on the west; however, the antithetic fault is much smaller both in horizontal extension and in vertical displacement than the Hupo Fault. Sediment infill in the Hupo Basin consists of syn-rift (late Oligocene. early Miocene) and post-rift (middle Miocene.Holocene) units. The Hupo Fault and other faults newly defined in the Hupo Basin strike dominantly north and show a sense of normal displacement. Considering that the East Sea has been subjected to compression since the middle Miocene, we interpret that these normal faults were created during continental rifting in late Oligocene to early Miocene times. We suggest that the current ENE direction of maximum principal compressive stress observed in and around the Korean peninsula associated with the motion of the Amurian Plate induces the faults in the Hupo Basin to have reverse and right-lateral, strike-slip motion, when reactivated. A recent earthquake positioned on the Hupo Fault indicates that in the study area and possibly further in the eastern Korean margin, earthquakes would occur on the faults created during continental rifting in the Tertiary.

Flexural Tensile Strength of CJP Groove Welded Joints Connecting Thick HSA800 Plates (HSA800 후판재의 완전용입 맞댐용접부 휨-인장강도 실험)

  • Lee, Cheol Ho;Kim, Dae Kyung;Han, Kyu Hong;Park, Chang Hee;Kim, Jin Ho;Lee, Seung Eun;Kim, Do Hwan
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.5
    • /
    • pp.407-418
    • /
    • 2014
  • As a continuing work of previously conducted standard tension tests, full-scale flexural tests were conducted in this study to assess the structural performance the CJP groove welded joints connecting thick HSA800 plates. Two welding electrodes were available at the time of this experimental research; one was GMAW-based electrode A and the other FCAW-based electrode B. Three full-scale box-type beam specimens with single bevel- and V-groove CJP welded joints were fabricated from 60mm and 25mm thick HSA800 plates according to the AWS-prequalified groove welded joint details. In designing the specimens, all possible limit states like local and lateral torsional buckling were carefully controlled in order to induce flexural plastic yielding or eventual joint fracture. All the CJP joints made by both welding electrodes showed satisfactory performance and were able to transfer the tensile flange forces higher than that corresponding to the measured tensile strength of HSA800 flange plates. However, it should be noted that, during fabrication, serious concerns about the welding efficiency and workability of the GMAW-based electrode were raised by a certified welder. The fracture occurred at the unbeveled (or vertical) interface between the weldment and the base metal when the GMAW-based electrode was used in the single-bevel joint, implying the possibility of insufficient melting. Thus, the FCAW-based electrode B is again recommended as the choice of welding electrode for HSA800 plates. The limited test data of this study implies that the V-groove CJP joint should be used in favor of the single bevel CJP joint, if possible.

Accuracy assessment of implant placement using a stereolithographic surgical guide made with digital scan (디지털 스캔을 이용하여 제작된 임플란트 수술가이드의 정확도)

  • Jeong, Seung-Mi;Fang, Jeong-Whan;Hwang, Chan-Hyeon;Kang, Se-Ha;Choi, Byung-Ho;Fang, Yiqin;Jeon, Hyongtae;An, Sunghun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.2
    • /
    • pp.111-119
    • /
    • 2015
  • Purpose: The objective of this study was to evaluate the accuracy of a stereolithographic surgical guide that was made with information from intraoral digital impressions and cone beam CT (CBCT). Materials and methods: Six sets of resin maxilla and mandible models with missing teeth were used in this study. Intraoral digital impressions were made. The virtual models provided by these intraoral digital impressions and by the CBCT scan images of the resin models were used to create a surgical guide. Implant surgery was performed on the resin models using the surgical guide. After implant placement, the models were subjected to another CBCT scan to compare the planned and actual implant positions. Deviations in position, depth and axis between the planned and actual positions were measured for each implant. Results: The mean deviation of the insertion point and angulation were 0.28 mm and $0.26^{\circ}$, apex point were 0.11 mm and 0.14 mm respectively. The implants were situated at a mean of 0.44 mm coronal to the planned vertical position. Conclusion: This study demonstrates that stereolithographic surgical guides created without the use of impressions and stone models show promising accuracy in implant placement.

An Structural Design for Cyclone Tower's Connections Using Diagrid System (다이아그리드 구조시스템의 접합부개발과 성능평가)

  • Lee, Se-Jung;Lee, Seong-Hui;Kim, Jin-Ho;Choi, Sung-Mo
    • Journal of Korean Association for Spatial Structures
    • /
    • v.10 no.2
    • /
    • pp.105-115
    • /
    • 2010
  • Recently, High-rise building are irregular-shaped to be city landmarks and function as vertical cities to enable the efficient use of land. 3T (Twisted, Tilted & Tapered) designs are being suggested for irregular buildings and studies to develop new structural system have been actively made to satisfy slender shape ratio. In diagrid system, not only gravity load but also lateral load is delivered based on the triangular shape of diagrid, so most of columns are eliminated. Because shearing force is delivered by the axial behavior (tensile/compressive) of diagrid to minimize shearing deformation, the system is more applicable to irregular buildings than existing system where shearing force is delivered by the columns. In this study, the process of selecting connection details and the structural safety of the selected details are verified using the finite element analysis with focus given to the construction overview of the Cyclone Tower. However, the relersed methods of stress concentration are suggested and the performance of stress concentration relieves that it's suggested for the appropriate cap plate thickness and extended length.

  • PDF

An Experimental Study on the Shear Behavior of Reinforced Concrete Beams Strengthened by Slit Type Steel Plates with Anchor Bolt (앵커볼트 체결 Slit형 강판 보강 RC보의 전단거동에 관한 실험적 연구)

  • Lee, Choon-Ho;Jeong, Woo-Dong;Shim, Jong-Seok
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.5
    • /
    • pp.703-710
    • /
    • 2010
  • Reinforced concrete beams of existing structure often encounter insufficient shear problems for various reasons. Application of steel plates is one of widely used methods for shear strengthening of reinforced concrete beams that are insufficient of shear capacity. This study presents test results on strengthening shear deficient RC beams by external bonding of vertical and diagonal slit type steel plates with anchor bolt. Test parameters are width, interval, angle and length of slits with anchor bolt. The purpose was to evaluate the failure modes and shear capacities for RC beams strengthened by various slit type steel plates with anchor bolt. The results showed that the slit type steel plate specimens strengthened by adhesive bonding and bolting failed in shear fracture modes at maximum load. Flexural crack first occurred on the tension face of beam and then inclined cracks occurred on the shear span. Finally, slit type steel plates strengthened by adhesive bonding and fastening bolts managed to delay abrupt debonding and didn't detach fully from main body of RC beam.

Shape Oscillation and Detachment of Droplet on Vibrating Flat Surface (진동하는 평판 위의 액적의 형상 진동 및 제거 조건에 대한 연구)

  • Shin, Young-Sub;Lim, Hee-Chang
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.4
    • /
    • pp.337-346
    • /
    • 2014
  • This study aimed to understand the mode characteristics of a droplet subject to periodic forced vibration and the detachment of a droplet placed on a plate surface. An surface was coated with Teflon to clearly observe the behavior of a droplet. The contact angle between the droplet and surface and the hysteresis were found to be approximately $115^{\circ}C$ and within $25^{\circ}C$, respectively. The coating process was performed in a clean room that had an environment with a low level of contaminants and impurities such as air dust, detergents, and particles. To predict the resonance frequency of a droplet, theoretical and experimental approaches were applied. Two high-speed cameras were configured to acquire side and top views and thus capture different characteristics of a droplet: the mode shape, the detachment, the separated secondary droplet, and the waggling motion. A comparison of the theoretical and experimental results shows no more than 18 discrepancies when predicting the resonance frequency. These differences seem to be caused by contact line friction, nonlinear wall adhesion, and the uncertainty of the experiment. For lower energy inputs, the contact line of the droplet was pinned and the oscillation pattern was axisymmetric. However, the contact line of the droplet was de-pinned as the oscillation became more vigorous with increased energy input. The size of each lobe at the resonance frequency is somewhat larger than that at the neighboring frequency. A droplet in mode 2, one of the primary mode frequencies, exhibits vertical periodic movement as well as detachment and secondary ejection from the main droplet.

Changes of the Electromyographic Activity by Head Posture and Cervical Spine Shape (두부자세와 경추형태에 따른 근활성의 변화에 관한 연구)

  • Ho-Chun Hwang;Kyung-Soo Han;Chan Jung
    • Journal of Oral Medicine and Pain
    • /
    • v.21 no.2
    • /
    • pp.393-405
    • /
    • 1996
  • This study was performed to investigate the effects of changes of head posture and cervical spine shape on the mandibular resting or clenching electromyographic(EMG) activity in anterior temporalis(TA), masseter(MM), sternocleidomastoid muscle(SCM) and trapezius insertion(TI). 30 patients with Temporomandibular Disorders(TMDs) participated in this study. EMG activity($\mu$V) at rest and clenching was observed in four head postures, namely natural head posture(NHP), forward head posture(FHP), upward head posture(UHP), and downward head posture(DHP). For taking in upward or downward head posture head was inclined 10$^{\circ}$ upward or downward and CROM$^\textregistered$(cervical-range-of motion, Performance attainment Inc., USA) was used to maintain same posture during the procedure, and BioEMG$^\textregistered$ (Bioelectromyograph, Bioresearch Inc., USA) was used to record EMG activity in the above four muscles at eight locations on both sides. The recorded EMG activity($\mu\textrm{V}$) were compared and analyzed by cervical spine shape such as the head position from plum line, cervical curvature, and cervical inclination. Head position from plum line was measured in vertical plate calibrated with cm scale, comical curvature by radius was measured with adjustable curved ruler, and cervical inclination by cervical vertebrae tangent(CVT)was measured in lateral cephalograph. The results obtained were as follows : 1. Mean value of head position from plum line, cervical curvature, and cervical inclination were 4.8cm, 26.7cm, and 86.6$^{\circ}$, respectively, And There were no correlationship among these items. 2. For resting EMG activity by head posture, the value in anterior temporalis was higher at FHP than at DHP, the value in masseter was higher at FHP than at NHP, and DHP, the value in sternocleidomastoid muscle was higher at UHP than at NHP, and the value in trapezius insertion was higher at FHP and DHP than, NHP and UHP. The clenching EMG activity, however, did not show any difference by head posture. 3. Comparison of resting and clenching EMG activity between higher and lower groups by head position from plum line, cervical curvature, and cervical inclination did not show any significant difference. From this result, the author concluded that the cervical spine shape had not significantly affected to EMG activity in usual patients with TMDs.

  • PDF

Urinary Urea Nitrogen and Creatinine Ratio of School Child -as an indicator of protein intake- (국민학교(國民學校) 아동(兒童)의 단백식이(蛋白食餌) 섭취(攝取) 평가(評價)에 관(關)한 연구(硏究) -요중(尿中) 요소(尿素) 질소(窒素)와 요중(尿中) Creatinine 비(比)에 의(依)한-)

  • Tchai, B.S.;Kim, H.O.
    • Journal of Nutrition and Health
    • /
    • v.5 no.4
    • /
    • pp.151-159
    • /
    • 1972
  • Protein malnutrition of children is one of the most serious nutritional deficiencies in developing country. Urea nitrogen excretion in ureotelic animals is the function most sensitive to dietary protein. The 24 hours excretion of creatinine in the urine of a given subject is remarkably constant from day to day. The creatinine excretion of different individuals of the same age and sex is also quite constant. Low ratios of urinary urea to creatinine are found children low protein intake. The foregiving world-wide investigations indicate that the urea nitrogen/creatinine ratios seems to be a good biochemical indicator to distinguish among group with different levels of protein intake. The purpose of this study is to evluate an indicator of protein intake on the elementary school children ranged from 6 to 8 years of age living in rural and urban areas. Each child measured for height and weight of body. weight measured by means of a plate from scale and height by a vertical measuring rod. Biochemical test were taken from a finger-tip and urine. Hemoglobin level in the blood was measured by cyanomethemoglobin method. From the urine samples, urea nitrogen and urea creatinie were determined by Folin-Wu method and: calculate the ratio. The following result were obtained: 1) Mean of the body weight and height in urban children(Seoul) was higher and heavier than rural children(Kyunggi, Kangwon). And 12% of boys, 18% of girls in Kyunggi and 25% of boys, 22% of girls in Kangwon area weight less than 80% of Korean Physical Standard weight level. 2) The mean hemoglobin values of boys and girls in Seoul are children were 13. 3g/100ml, 13.1g/100ml and the mean of hemoglobin values in Kyunggi 12.9g/100ml of boys, 12.4g/100ml of girls, and 12.4g/100ml of boys, 12.9g/100ml of girls in Kangwon children. It is found that 22% to 24% children inrural area (Kyunggi, Kangwon) had hemoglobin level less than 12g/100ml which means anemia. 3) The mean of hematocrit level of Seoul, boys and girls children were 33.5%, 34.1% and 33.4%, 33.1%, in Kyunggi area and 33.1%, 32.9% in Kangwon area. 4) Urea nitrogen/creatinine ratios in Seoul children were 9. 0, 10. 0 of boys and girls, the ratio were 8.2, 8.0 in Kyunggi boys and girls children, and 7.5 and 7.4 in Kangwon boys, girls children. Low-income rural and upper-income urban background large differences between two groups in the urea nitrogen/creatinine ratio(Seoul: Kangwon in male, female children. p<0.05, p<0.001). The urea nitrogen/creatinine ratio definetly seems to be a good indicator of the quantity of the protein intake. However, whether or not it is an indicator of the quality of the ingested protein ramains to be seen.

  • PDF

Stiffness evaluation of elastomeric bearings for leg mating unit (LMU용 일래스토머릭 베어링의 강성평가)

  • Han, Dong-Seop;Jang, Si-Hwan;Lee, Kwon-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.12
    • /
    • pp.106-111
    • /
    • 2017
  • In this study, the stiffness of an LMU (Leg Mating Unit), which is a device required for installing the top side part of an offshore structure, was examined through structural analysis. This unit is mounted on the supporting point of the structure and is used to absorb the shock at installation. It is a cylindrical structure with an empty center. To support the vertical load, elastomeric bearings (EBs) and iron plates are laminated in layers. The stiffness of the EBs is basically influenced by the size of the bearings, but it varies with the number of laminated sheets inside the same sized structure. The relationship between the stiffener and the compressive stiffness is investigated, and its design is suggested. The stiffness of the EBs is analyzed by calculating the reaction force, while controlling the displacement. First, the relationship between the size of the reinforcing plate and the compressive stiffness is considered. Next, the relationship between the number of stacked reinforcing plates and the compression stiffness is considered. Different loads are required for each installed point. The goal is to design the compression stiffness in such a way that the same deformation occurs at each point in the analysis. In this study, ANSYS is used to perform the FE analysis.

A Numerical Model of Three-dimensional Soil Water Distribution for Drip Irrigation Management under Cropped Conditions (작물 흡수를 고려한 3차원 토양수분 분포 모델 개발을 통한 최적 점적 관개 연구)

  • Kwon, Jae-Phil;Kim, Seung-Hyun;Yoo, Sun-Ho;Ro, Hee-Myong
    • Applied Biological Chemistry
    • /
    • v.43 no.2
    • /
    • pp.116-123
    • /
    • 2000
  • A numerical model of three-dimensional soil water distribution for drip irrigation management under cropped conditions was developed using Richards equation in Cartesian coordinates. The model accounts for both seasonal and diurnal changes in evaporation and transpiration, and the growth of plant root and the shape of root zone. Solutions were numerically approximated using the Crank-Nicolson implicit finite difference technique on the block-centered grid system and the Gauss-Seidel elimination in tandem. The model was tested under several conditions to allow the flow rates and configurations of drip emitters vary. In general, simulation results agreed well with experimental results and were as follows. The velocity of soil-water flow decreased drastically with distance from the drip source, and the rate of expansion of the wetted zone decreased rapidly during irrigation. The wetting front of wetted zone from a surface drip emitter traveled farther in vertical direction than in horizontal direction. Under this experimental weather condition, water use efficiency of a drip-irrigated apple field was greatest for 4-drip-emitter system buried at 25 cm, resulting from 10% increase in transpiration but 20% reduction in soil evaporation compared to those for surface 1-drip emitter system. Soil moisture retention curve obtained using disk tension infiltrometer showed significant difference from the curve obtained with pressure plate extractor.

  • PDF