• Title/Summary/Keyword: Vertical Magnetization

Search Result 18, Processing Time 0.026 seconds

A Study on Intial Susceptibility for the Prediction of Vertical Magnetization in Flash D Demagnetization (Flash D 탈자방법에서 수직자화예측을 위한 초기자화율에 관한 검토)

  • Kim, Young-Hak;Doh, Jaewon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.17 no.5
    • /
    • pp.585-590
    • /
    • 2014
  • A permanent vertical magnetization should be obtained to counteract induced vertical magnetization due to the earth's background field during the Flash D demagnetization process. A vertical susceptibility is needed to calculate a extra-permanent magnetization, which is needed to control the permanent vertical magnetization in stage 2 of Flash D demagnetization and added to the final vertical permanent magnetization. Two susceptibilities were found in this paper. One is obtained from the extra-magnetization. The other is obtained by magnetic field measurement from the scaled physical vessel when the vessel is excited by vertical magnetic field. The initial susceptibility by the extra-magnetization was 0.101~0.109 and the one from the measured magnetic field was 0.122. Two susceptibilities have a good agreement each other. From this paper, it is found that the susceptibility is able to appllied to calculate the extr-magnetization.

Demagnetization to Induce Vertical Magnetization in a Military Vessel (함정에 수직자화를 부여하기 위한 탈자)

  • Kim, Young-Hak
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.1109-1112
    • /
    • 2015
  • A milatary ship without degaussing coil has a vertical magnetization to compensate magnetization induced by the vertical magnetic field component of earth magnetic field during demagnetization process. Flash D is very useful to acquire vertical magnetization. However this is hard to predict vertical magnetization. This experiment was investicated on another method, which used the only vertical bias magentic field. The specimens were prepared by thin Zn coated steel sheet with a thickness of 0.15mm. The shapes of 3 specimes was rectangular, triangular and circular cylinders. These shapes were corresponded to the shapes of bow, mid and stern of a vessel. Through FEM analysis, the difference of magnetic signatures for these specimens was recognized and the residual magnetization curve was measured. magnetic field was generated by a solenoid coil and magnetic signature was measured by a magnetic field sensor. A linearity between a vertical bias magnetic field and a vertical manetzation existed and the vertical magnetization of a miltary vessel was predicted by the linearity.

  • PDF

Investigation on the component separation of magnetic signal generated from a ferro-magnetic vessel (함정에서 발생하는 자계신호의 성분분리에 대한 검토)

  • Kim, Young-Hak;Doh, JaeWon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.8
    • /
    • pp.2051-2056
    • /
    • 2014
  • This paper investigated the separation of magnetic signal from a ferro-magnetic object. The magnetic signals were ILM(induced longitudinal magnetization) and IVM(induced vertical magnetization), which were induced by earth magnetic field and PLM(permanent longitudinal magnetization) and PVM(permanent vertical magnetization), which were due to a permanent magnetization of the object, respectively. Magnetic signal separation was based on the fact that magnetization vector could be analyzed according to longitudinal and vertical directions. Also the influence of non-uniform magnetic field from a rectangular coil on the separation was examined. A military vessel with a size close to rectangular coil has more errors on the magnetic signal separation.

Demagnetization Performance According to Vertical and Horizontal Magnetic Bias Fields

  • Kim, Young-Hak;Kim, Ki-Chan;Shin, Kwang-Ho;Yoon, Kwan-Seob;Yang, Chang-Seob
    • Journal of Magnetics
    • /
    • v.16 no.4
    • /
    • pp.453-456
    • /
    • 2011
  • Demagnetization for a tube sample which was made of a galvanized steel sheet was performed by applying a magnetic field with a decrement to remove the remanent magnetization of the material. An orthogonal fluxgate magnetic field sensor was used to measure a magnetic field created from a ferromagnetic material. To evaluate the remanent magnetization, the measured magnetic fields were separated into two magnetic field components by the remnant magnetization and the induced one. The horizontal and the vertical bias fields should be controlled separately during demagnetization to remove the horizontal and the vertical components of the remanent magnetization of the tube sample.

Theoretical Consideration of Nondestructive Testing by use of Vertical Magnetization and Magneto-Optical Sensor

  • Lee, Jinyi;Tetsuo Shoji;Dowon Seo
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.640-648
    • /
    • 2004
  • This paper describes a new magnetization method for non-destructive testing with magneto-optical sensor (denoted as MO sensor) which have the following characteristic : high observation sensitivity, independence of the crack orientation, and precise imaging of a complex crack geometry such as multiple cracks. When a magnetic field is applied normally to the surface of a specimen which is significantly larger than its defects, approximately the same magnetic charge per unit area occurs on the surface of the specimen. If there is a crack in the specimen, magnetic charge per unit area has the same value at the bottom of the crack. The distribution of the vertical component of the magnetic flux density, B$\_$Z/, is almost uniform over the no-crack area (denoted as B$\_$Z,BASE/), while the magnetic flux density is smaller in the surroundings of the crack(denoted as B$\_$Z,CRACK/) If B$\_$Z, BASE/ is a bit larger than the saturated magnetic flux density of the MO sensor (B$\_$s/) , then small magnetic domains occur over the crack area and a large domain over the non-crack area because B$\_$Z,CRACK/ is smaller than B$\_$s/.

Influence of Shape Demagnetization Effect for Naval Vessel Deperming (함정의 형상 반자계 효과가 탈자에 미치는 영향)

  • Kim, Young-Hak
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.2
    • /
    • pp.445-450
    • /
    • 2016
  • This paper studied on the influence of naval vessel shape on vertical magnetic field after the vessel was demagnetized. The triangular shape, the rectangular shape and circular shape were adaped from vessel's structual drawings. Magneto-static FEM analysis was performed to obtain the iduced magnetic field due to earth magnetic field for those shapes. During demagnetization process, magnetic field of residual magnetization was observed. The holizontal and vertical magnetic field were calculated depending on vertical bias magnetic field through magnetc component seperation. To demagnetize naval vessel ship, demagnetizing coils shoud be wound more finely in the vow and stern of the ship than it should be in the mid-part of the ship.

A Study of the Vibration Characteristics of a Haptic Vibrator for Horizontal and Vertical Magnetization (수평 및 수직 착자에 대한 햅틱 진동자의 진동특성에 관한 연구)

  • Ko, Dong Shin;Hur, Deog Jae;Park, Tae Won;Lee, Jai Hyuk;Lee, Sung Su
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.4
    • /
    • pp.415-421
    • /
    • 2015
  • This paper describes the study of the design procedure for the step-by-step setup parameters and of the magnetizing method for performance and size reduction in the development of a haptic vibrator. The study of magnetization was accomplished by comparing the electromagnetic force in accordance with the horizontal and the vertical magnetization. The theoretical results indicated that the horizontal magnetization resulted in a better performance. The systematic design of a step-by-step procedure for establishing the design parameters was verified by testing the characteristics of the fabricated prototype product. The vibration response function analysis and electric field analysis were processed by decoupling of the analytical method, and these were determined to be in good agreement with the test results. The design parameters to contributing to the product reliability included the spring height, the welding position, and the coil position. The sensitivity of the electromagnetic field and the performance change were analyzed based on the design parameters. As a result, we proposed a design method to implement a reliability-based, high performance haptic vibrator.

Interpretation of the Magnetic Logs for a Finite Line of Magnetic Dipoles Model (유한 선형 자기쌍극자 모델에 대한 검층자료의 해석)

  • Kim, Jin Hu
    • Journal of the Korean Geophysical Society
    • /
    • v.2 no.2
    • /
    • pp.135-142
    • /
    • 1999
  • Interpretations of 3-component magnetic logging data obtained for a reinforced bar as a model of the line of the magnetic dipoles are conducted using a least squared inversion technique. The length of the bar is 1.12 m, sampling interval is 0.05 m, the distance between the bar and the borehole is 0.3 m, and the top of the bar is fixed at 0 m of depth. The bar is set to be approximately vertical. Magnetic anomalies smoothed with FFT are used as input data for the inversion. For the interpretation of magnetic logging data the depth to the top, the length, the magnetic moment per unit length, the direction of the magnetization (declination and inclination), and the bearing and plunge of the line of magnetic dipoles are left as unknown parameters. The comparison of the results obtained from the individual inversion of the horizontal component or the vertical component of the magnetic anomalies, and those from the simultaneous inversion of horizontal and vertical component of the magnetic anomalies shows that there exist some disagreements between each inversion result. The depth to the bottom of the bar, which is actually 1.12 m, is estimated as 1.18 m, and the inclination of the magnetization is estimated as -76°by simultaneous inversion. The negative value of the inclination indicates that the strength of the remnant magnetization is much greater than that of the induced magnetization, so that the direction of the resultant magnetization points to the top of the bar.

  • PDF

An Algorithm for the Characterization of Surface Crack by Use of Dipole Model and Magneto-Optical Non-Destructive Inspection System

  • Lee, Jin-Yi;Lyu, Sung-Ki;Nam, Young-Hyun
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.10
    • /
    • pp.1072-1080
    • /
    • 2000
  • Leakage magnetic flux (LMF) is widely used for non-contact detection of cracks. The combination of optics and LMF offers advantages such as real time inspection, elimination of electrical noise, high spatial resolution, etc. This paper describes a new nondestructive evaluation method based on an original magneto-optical inspection system, which uses a magneto-optical sensor, LMF, and an improved magnetization method. The improved magnetization method has the following characteristics: high observation sensitivity, independence of the crack orientation, and precise transcription of the geometry of a complex crack. The use of vertical magnetization enables the visualization of the length and width of a crack. The inspection system provides the images of the crack, and shows a possibility for the computation of its depth.

  • PDF

Structural, Optical, and Magnetic Properties of Si1-xMnxTe1.5 Single Crystals (Si1-xMnxTe1.5 단결정의 구조적, 광학적, 자기적 특성에 관한 연구)

  • Hwang, Young-Hun;Um, Young-Ho;Cho, Sung-Lae
    • Journal of the Korean Magnetics Society
    • /
    • v.16 no.3
    • /
    • pp.178-181
    • /
    • 2006
  • We have investigated the Mn concentration-dependent structural, optical, magnetic properties in IV-VI diluted magnetic semiconductor $Si_{1-x}Mn_xTe_{1.5} $ crystals prepared by the vertical Bridgman technique. X-ray studies showed the single crystalline hexagonal crystal structure. From the optical absorption measurements energy band gap were found to decreases with increasing x and temperature. From the magnetization measurements the samples had ferromagnetic ordering with Curie temperature $T_C$ about 80 K. With increasing Mn concentration, the average magnetic moments per Mn atom determined from the saturated magnetization increased.