• Title/Summary/Keyword: Vertical Image

Search Result 999, Processing Time 0.028 seconds

The Effects of Image Training and Vibration on Performance of Vertical Jumping (상상 훈련과 진동 운동의 적용이 수직점프의 수행력에 미치는 영향)

  • Bang, Hyun-Soo;Jung, Byeong-Ok;Kim, Jin-Sang
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.4 no.1
    • /
    • pp.49-56
    • /
    • 2009
  • Purpose : The Purpose of this study was to investigate the effects of image training and vibration on performance of vertical jumping. Methods : Subjects was classified into two groups, which were image training group(n=20) and vibration application group(n=20). The standard methods of each intervention were image training with listening recorded indication for 5 minute and vibration with speed of $1200{\pm}200\;rpm$. Muscle strength was measured using vertical jump performance. Results : The vertical jump performance was significantly increased after image training and vibration application(p<.05), however, it was more significantly after image training(p<.05). Conclusion : This study showed that image training and vibration application were effective treatment strategy on increase of muscle strength. Therefore, it could be considered as a treatment method in the patients with musculoskeletal disease including fracture, chronic degenerative disease and disuse atrophy.

  • PDF

Vertical Space Analysis for Gradient Radiating Steel-tube Radiographic Image (경사조사(傾斜照射) 강판튜브 방사선 관측영상의 수직 방향 공간분석)

  • Hwang, Jung-Won;Hwang, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.29-31
    • /
    • 2007
  • In this paper we propose an directional analytic approach in image data space for X-ray image which is detected from the X-ray projection system. Such a radiographic nondestructive testing has long been used for steel-tube inspection and weld monitoring. The welded area and thickness of steel-tube are detected from gradient radiating mechanism based on the evaluation of biased X-ray source position. The welded area is an ellipse type on low contrast X-ray image including noise. Noise originates from most of elements of the system. such as shielding CCD camera, imaging screen, X-ray source, inspected object, electronic circuits and etc.. Projection incorrectness and noise influence on imaging quality is to be represented by vertical pixels' distribution. Space analysis due to vertical direction also shows the segmental possibility between regions by visual edge evaluation.

  • PDF

Ground Deformation Evaluation during Vertical Shaft Construction through Digital Image Analysis

  • Woo, Sang-Kyun;Woo, Sang Inn;Kim, Joonyoung;Chu, Inyeop
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.7 no.2
    • /
    • pp.285-293
    • /
    • 2021
  • The construction of underground structures such as power supply lines, communication lines, utility tunnels has significantly increased worldwide for improving urban aesthetics ensuring citizen safety, and efficient use of underground space. Those underground structures are usually constructed along with vertical cylindrical shafts to facilitate their construction and maintenance. When constructing a vertical shaft through the open-cut method, the walls are mostly designed to be flexible, allowing a certain level of displacement. The earth pressure applied to the flexible walls acts as an external force and its accurate estimation is essential for reasonable and economical structure design. The earth pressure applied to the flexible wall is closely interrelated to the displacement of the surrounding ground. This study simulated stepwise excavation for constructing a cylindrical vertical shaft through a centrifugal model experiment. One quadrant of the axisymmetric vertical shaft and the ground were modeled, and ground excavation was simulated by shrinking the vertical shaft. The deformation occurring on the entire ground during the excavation was continuously evaluated through digital image analysis. The digital image analysis evaluated complex ground deformation which varied with wall displacement, distance from the wall, and ground depth. When the ground deformation data accumulate through the method used in this study, they can be used for developing shaft wall models in future for analyzing the earth pressure acting on them.

Self-Localization of Autonomous Mobile Robot using Multiple Landmarks (다중 표식을 이용한 자율이동로봇의 자기위치측정)

  • 강현덕;조강현
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.10 no.1
    • /
    • pp.81-86
    • /
    • 2004
  • This paper describes self-localization of a mobile robot from the multiple candidates of landmarks in outdoor environment. Our robot uses omnidirectional vision system for efficient self-localization. This vision system acquires the visible information of all direction views. The robot uses feature of landmarks whose size is bigger than that of others in image such as building, sculptures, placard etc. Robot uses vertical edges and those merged regions as the feature. In our previous work, we found the problem that landmark matching is difficult when selected candidates of landmarks belonging to region of repeating the vertical edges in image. To overcome these problems, robot uses the merged region of vertical edges. If interval of vertical edges is short then robot bundles them regarding as the same region. Thus, these features are selected as candidates of landmarks. Therefore, the extracted merged region of vertical edge reduces the ambiguity of landmark matching. Robot compares with the candidates of landmark between previous and current image. Then, robot is able to find the same landmark between image sequences using the proposed feature and method. We achieved the efficient self-localization result using robust landmark matching method through the experiments implemented in our campus.

CBCT analysis of three implant cases for treatment planning (임플란트 치료 전 CBCT 영상분석 세 증례)

  • Kim, Jae-Duk;Kim, Kwang-Won;Lim, Sung-Hoon
    • Imaging Science in Dentistry
    • /
    • v.37 no.3
    • /
    • pp.171-180
    • /
    • 2007
  • The role of radiographic imaging in determining the size, numbers and the position of implants is very important. To perform the implant procedure, the dentist needs to evaluate the bone pathology and bone density, and to know the precise height, width, and contour of the alveolar process, as well as its relationship to the maxillary sinus and mandibular canal. The author analyzed 3 implant cases for treatment planning with the cone beam CT. All axial, panoramic, serial and buccolingual-sectioned images of 3 cases with stent including vertical marker were taken by using Mercuray (Hitachi, Japan). When the curved line drawn intentionally did not include dot image of a vertical marker on the axial image of CBCT, the image of the vertical marker was deformed on its buccolingually sectioned image. There was wide discrepancy in inclination between the alveolar bone and tooth on buccolingually sectioned image.

  • PDF

Evaluation of the Noise Power Spectrum by Using American College of Radiology Phantom for Magnetic Resonance Imaging (자기공명영상에서 ACR 팬텀을 이용한 잡음전력스펙트럼 평가)

  • Jung-Whan Min;Hoi-Woun Jeong
    • Journal of radiological science and technology
    • /
    • v.47 no.1
    • /
    • pp.21-28
    • /
    • 2024
  • This study was purpose to quantitative evaluation of comparison of the image intensity uniformity and noise power spectrum (NPS) by using American college of radiology (ACR) phantom for magnetic resonance imaging (MRI). The MRI was used achiva 3.0T MRI and discovery MR 750, 3.0T, the head and neck matrix shim SENSE head coil were 32 channels receive MR coil. The MRI was used parameters of image sequence for ACR standard and general hospital. NPS value of the ACR standard T2 vertical image in GE equipment was 7.65E-06 when the frequency was 1.0 mm-1. And the NPS value of the ACR hospital T1 region of interest (ROI) 9 over all vertical image in Philips equipment was 9E-08 when the frequency was 1.0 mm-1 and the NPS value of the hospital T2 ROI 9 over all vertical image in Philips equipment was 1.06E-07 when the frequency was 1.0 mm-1. NPS was used efficiently by using a general hospital vertical sequence more than the standard vertical sequence method by using the ACR phantom. Furthermore NPS was the quantitative quality assurance (QA) assessment method for noise and image intensity uniformity characteristics was applied mutatis mutandis, and the results values of the physical imaging NPS of the 3.0T MRI and ACR phantom were presented.

Elastic solutions for shallow tunnels excavated under non-axisymmetric displacement boundary conditions on a vertical surface

  • Wang, Ling;Zou, Jin-Feng;Yang, Tao;Wang, Feng
    • Geomechanics and Engineering
    • /
    • v.19 no.3
    • /
    • pp.201-215
    • /
    • 2019
  • A new approach of analyzing the displacements and stress of the surrounding rock for shallow tunnels excavated under non-axisymmetric displacement boundary conditions on a vertical surface is investigated in this study. In the proposed approach, by using a virtual image technique, the shear stress of the vertical ground surface is revised to be zero, and elastic solutions of the surrounding rock are obtained before stress revision. To revise the vertical normal stress and shear stress of horizontal ground surface generated by the combined action of the actual and image sinks, the harmonic functions and corresponding stress function solutions were adopted. Based on the Boussinesq's solutions and integral method, the horizontal normal stress of the vertical ground surface is revised to be zero. Based on the linear superposition principle, the final solution of the displacements and stress were proposed by superimposing the solutions obtained by the virtual image technique and the stress revision on the horizontal and vertical ground surfaces. Furthermore, the ground settlements and lateral displacements of the horizontal and vertical ground surfaces are derived by the proposed approach. The proposed approach was well verified by comparing with the numerical method. The discussion based on the proposed approach in the manuscript shows that smaller horizontal ground settlements will be induced by lower tunnel buried depths and smaller limb distances. The proposed approach for the displacement and stress of the surrounding rocks can provide some practical information about the surrounding rock stability analysis of shallow tunnels excavated under non-axisymmetric displacement boundary conditions on a vertical surface.

Measurement of Fluorescence Signal Strength of NO Particle Using ICCD (ICCD를 이용한 NO입자의 형광신호강도 측정)

  • 전용우;박원주;이광식;이홍식
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.4
    • /
    • pp.23-30
    • /
    • 2001
  • In this paper, the discharge image of NO particles wire-cylinder type electrode in the discharge reactor where AC dielectric barrier type corona discharge occurred and horizontal and vertical signal intensity at each flourescence emission during discharge and the horizontal and vertical signal strength of NO particles at flourescence emission wavelength band[236[nm], 247[nm]], were measured were measured by ICCD Camera. In addition discharge images and signal intensities in accordance with discharge time were measured to figure out the discharge mechanism. It was found that the strongest horizontal and vertical signal intensity of NO particles were observed at 247[nm] band, but no big difference in the horizontal and vertical signal intensity in accordance with discharge time was seen. In particular, the phenomenon image occuring inside the discharge reactor and wavelength ware able to be carried based on the measured data.

  • PDF

Panoramic Image Composed of Multiple Rectilinear Images Generated from a Single Fisheye Image

  • Kweon, Gyeong-Il
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.2
    • /
    • pp.109-120
    • /
    • 2010
  • We have developed mathematically precise image-processing algorithms for extracting rectilinear images from fisheye images as well as digital pan/tilt/zoom technology. Using this technology, vertical lines always appear as vertical lines in the panned and/or tilted images. Furthermore, polygonal panoramic images composed of multiple rectilinear images have been obtained using the developed digital pan/tilt technology.

3-DIMENSIONAL TILING TECHNIQUE TO PROCESS HUGE SIZE HIGH RESOLUTION SATELLITE IMAGE SEAMLESSLY AND RAPIDLY

  • Jung, Chan-Gyu;Kim, Jun-Chul;Hwang, Hyun-Deok
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.85-89
    • /
    • 2007
  • This paper presents the method to provide a fast service for user in image manipulation such as zooming and panning of huge size high resolution satellite image (e.g. Giga bytes per scene). The proposed technique is based on the hierarchical structure that has 3D-Tiling in horizontal and vertical direction to provide the image service more effectively than 2D-Tiling technique in the past does. The essence of the proposed technique is to create tiles that have optimum level of horizontal as well as vertical direction on the basis of current displaying area which changes as user manipulates huge image. So this technique provides seamless service, and will be very powerful and useful for manipulation of images of huge size without data conversion.

  • PDF