• Title/Summary/Keyword: Vertical Calibration

Search Result 154, Processing Time 0.028 seconds

Effect of Particle Crushing on the Results on DMT in Sand (입자 파쇄가 사질토의 DMT 결과에 미치는 영향)

  • Lee, Moon-Joo;Choi, Young-Min;Kim, Min-Tae;Bae, Kyung-Doo;Lee, Woo-Jin
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.740-746
    • /
    • 2010
  • Most important characteristics of calcareous sand are the particle angularity and hollow structure. These characteristics lead to the different behavior of calcareous sand compared to siliceous sand. This study performs a series of dilatometer test using calibration chamber, in order to analyze the effect of particle characteristic of calcareous sand on DMT indices. From experimental test, it is observed that the horizontal stress index($K_D$) and dilatometer modulus($E_D$) of calcareous Jeju sand is underestimated compared to siliceous sand. This is because the particle crushing during penetration induces the less contraction of the dilatometer membrane. A slightly smaller influence of particle crushing is reflected in $E_D$ rather than $K_D$, because $P_1$ pressure reflects the deformation characteristics of un-crushed particle relatively well. It is also observed that $K_D$ of Jeju sand is differently influenced by the vertical effective stress compared with that of siliceous sand.

  • PDF

Inference Models for Tidal Flat Elevation and Sediment Grain Size: A Preliminary Approach on Tidal Flat Macrobenthic Community

  • Yoo, Jae-Won;Hwang, In-Seo;Hong, Jae-Sang
    • Ocean Science Journal
    • /
    • v.42 no.2
    • /
    • pp.69-79
    • /
    • 2007
  • A vertical transect with 4 km length was established for the macrofaunal survey on the Chokchon macrotidal flat in Kyeonggi Bay, Incheon, Korea, 1994. Tidal elevation (m) and sediment mean grain size $(\phi)$ were inversely predicted by the transfer functions from the faunal assemblages. Three methods: weighted average using optimum value (WA), tolerance weighted version of the weighted average (WAT) and maximum likelihood calibration (MLC) were employed. Estimates of tidal elevation and mean grain size obtained by using the three different methods showed positively corresponding trends with the observations. The estimates of MLC were found to have the minimum value of sum of squares due to errors (SSE). When applied to the previous data $(1990\sim1992)$, each of three inference models exhibited high predictive power. This result implied there are visible relationships between species composition and faunas' critical environmental factors. Although a potential significance of the two major abiotic factors was re-affirmed, a weak tendency of biological interaction was detected from faunal distribution patterns across the flat. In comparison to the spatial and temporal patterns of the estimates, it was suggested that sediment characteristics were the primary factors regulating the distribution of macrofaunal assemblages, rather than tidal elevation, and the species composition may be sensitively determined by minute changes in substratum properties on a tidal flat.

A Development of Fuzzy Logic-Based Evaluation Model for Traffic Accident Risk Level (퍼지 이론을 이용한 교통사고 위험수준 평가모형)

  • 변완희;최기주
    • Journal of Korean Society of Transportation
    • /
    • v.14 no.2
    • /
    • pp.119-136
    • /
    • 1996
  • The evaluation of risk level or possibility of traffic accidents is a fundamental task in reducing the dangers associated with current transportation system. However, due to the lack of data and basic researches for identifying such factors, evaluations so far have been undertaken by only the experts who can use their judgements well in this regard. Here comes the motivation this thesis to evaluate such risk level more or less in an automatic manner. The purpose of this thesis is to test the fuzzy-logic theory in evaluating the risk level of traffic accidents. In modeling the process of expert's logical inference of risk level determination, only the geometric features have been considered for the simplicity of the modeling. They are the visibility of road surface, horizontal alignment, vertical grade, diverging point, and the location of pedestrain crossing. At the same time, among some inference methods, fuzzy composition inference method has been employed as a back-bone inference mechanism. In calibration, the proposed model used four sites' data. After that, using calibrated model, six sites' risk levels have been identified. The results of the six sites' outcomes were quite similar to those of real world other than some errors caused by the enforcement of the model's output. But it seems that this kind of errors can be overcome in the future if some other factors such as driver characteristics, traffic environment, and traffic control conditions have been considered. Futhermore, the application of site's specific time series data would produce better results.

  • PDF

A Data Acquisition System based upon a Single-board Microcomputer (단일보드 마이크로 컴퓨터를 이용한 자료(資料) 수집장치(蒐集裝置))

  • Choi, C.H.
    • Journal of Biosystems Engineering
    • /
    • v.14 no.4
    • /
    • pp.221-228
    • /
    • 1989
  • A data acquisition system was designed to measure the forces on a rolling coulter in three coordinated directions, angular velocity of the coulter and travel speed of a soil bin. The data acquisition system consisted of a dynamometer, speed transducers, a signal conditioner, an inter-face board, an Aim-65 microcomputer and a digital data recorder. Strain gages were attached on the surface of the dynamometer and connected to form three Wheatstone bridges, which measure the draft force, the vertical force and the side force on the coulter. An interaction among three dimensional forces was found during the calibration. A matrix procedure was used to correct the forces for this interaction. Rotary shaft encoders were mounted on the coulter and on the soil bin drive to measure the angular velocity of the coulter and the travel speed of the soil bin. The angular velocity and the travel speed were computed by counting the number of pulse signals from the rotary shaft encoders every 0.2 second. The digital signals from the rotary shaft encoders were connected to counters and the analog signals from the dynamometer, after passing through the signal conditioner, were connected to the A/D converter. The microcomputer programs, written in assembly language, were developed to read signals from the transducers, convert them to actual unit, display them upon request and record them on a sigital tape every 0.2 second.

  • PDF

Reliability Analysis Modeling for LRFD Design of Bridge Abutments (LRFD 설계를 위한 교대의 신뢰성 해석 모델)

  • Eom, Jun-Sik
    • Journal of the Korean Geotechnical Society
    • /
    • v.30 no.8
    • /
    • pp.5-11
    • /
    • 2014
  • The objective of this paper is to develop a rational reliability analysis procedure for the LRFD design provisions of bridge substructures. A bridge abutments is considered in this study. The reliability analysis is applied to determine the relationship between the major design parameters for bridge abutment and reliability index. The considered load components include dead load, vertical and horizontal earth pressure, earth surcharge, and vehicle live load. Several limit states are considered: foundation bearing capacity, sliding, and overturning. The analysis results show that the most important parameter in the reliability analysis is the effective stress friction angle of the soil. The reliability indices are calculated using Monte Carlo simulations for a selected bridge abutment. The results of the sensitivity analysis indicate that reliability index is most sensitive with regard to resistance factor and horizontal earth pressure factor.

Evaluation of Cone resistance of A Jeju Sand and Its Cementation Possibility (제주해사의 콘선단저항 및 고결가능성 평가)

  • Lee, Moon-Joo;Kim, Jae-Jeong;Shim, Jai-Beom;Lim, Chai-Geun;Lee, Woo-Jin
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.1407-1414
    • /
    • 2009
  • In this study, a Jeju sand, which contains both siliceous and calcareous materials, was sampled from a beach in Jeju Island. It is observed that the Jeju sand has high extreme void ratios due to the angularity of grains and the intra-particle voids of hollow particles. From cone penetration test using calibration chamber system, it is found that the cone tip resistance($q_c$)-relative density(Dr)-vertical effective stress(${\sigma_v}'$) relation of Jeju sand almost matches to that of high compressible quartz sand. However, this correlation overestimates the relative density of a coastal sediments in Jeju Island maybe due to the cementation effect of this area. From analysis of the results of cone penetration and SPS tests at a coastal area in Jeju Island, it seems reasonable to assume that the coast of Jeju Island is a natural cemented sediments.

  • PDF

A Feed-forward Microsecond Level Real-time SOP Finding System (순방향 마이크로초 단위의 실시간 편광상태 검출 시스템)

  • Jung, Hyun-Soo;Shin, Seo-Yong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.1C
    • /
    • pp.94-101
    • /
    • 2008
  • In this paper, we introduce a real-time state-of-polarization(SOP) finding system. The system divides the optical wave into linear horizontal- and vertical-SOP components and measures two different beat-signals, which are produced by superposition with reference optical source, in time domain. From these measured beat signals we can get SOP information of the signal instantly. Since the proposed scheme is a feed-forward measurement system, comparing with conventional systems which require an optical feedback loop, the measurement time becomes reduced tremendously. We also introduced a novel calibration method for compensating birefringence-related errors which may occur during the measurement. We prove the operation and performance of the proposed system through computer simulation and actual experiments.

Comparison of Data Measured by Doppler Instruments at 1,550 nm and 23.2 cm Wavelengths (1,550 nm와 23.2 cm 파장의 도플러 측기 관측자료 비교)

  • Geon-Myeong Lee;Byung-Hyuk Kwon;Kyung-Hun Lee;Zi-Woo Seo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.6
    • /
    • pp.1041-1048
    • /
    • 2023
  • Wind LiDAR and Wind Profiler are devices that produce continuous vertical distribution of wind vector in high-resolution data, and their use has recently been increasing. Although the observation and data processing methods of the two devices are similar, differences in wind detection accuracy may occur depending on weather and operation settings. introduce the characteristics of the two instruments and wind calculation methods, and apply the latest instrument verification standards to evaluate their accuracy by comparing them with the wind observed with a radiosonde. Accordingly, a new direction for performance verification following the introduction of equipment and additional necessary complements are presented.

Increasing Surveyed Area using Tilted Multi Beam Echo Sounder (멀티빔 음향측심기의 기울임 시스템을 이용한 계측영역 확대)

  • Park, Yosup;Hong, Jun-Pyo;Kong, Seong-Kyu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.5D
    • /
    • pp.739-747
    • /
    • 2011
  • The paper presents implementation & evaluation of survey method with tilted transducer of Multi Beam Echo Sounder (MBES) to increase horizontal & vertical coverage over obstructed port environments with limited physical properties of MBES. Proposed method ($25^{\circ}$ titled transducer) have some discrepancy of bathymetric profiles between normal and tilting method, but we proved average difference is less than IHO Special Order requirements with survey data at port of Dong Ho Port, Masan, Korea. For horizontal mapping coverage of total survey area ($114,961m^2$), normal method covered 53%, $60,895m^2$ of total area but tilting method covered 75%, $5.933m^2$. It is 22% efficient than normal method with similar environments. For vertical mapping coverage of total vertical structure face ($7,421m^2$), normal method covered 14%, $1,046m^2$, proposed methods covered 60%, $4,450m^2$. And we adapt longitudal steel bar to validate MBES results, and provide calibration method with titled transducer of MBES.

Identifying Specifications of Flat Type Signboards Using a Stereo Camera (스테레오 카메라를 이용한 판류형 간판의 규격 판별)

  • Kwon, Sang Il;Kim, Eui Myoung
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.38 no.1
    • /
    • pp.69-83
    • /
    • 2020
  • Signboards are standardized according to national legislation for the safety of pedestrians and disaster prevention in urban areas. Signboards should be installed according to the standard. However, it is not easy to manage the signboards systematically due to the number of signboards that have been installed for a long time and frequently changing stores. In this study, we proposed a methodology for distinguishing signboards that deviated from the standard. To this end, the signboard was photographed using a stereo camera, and then the three-dimensional coordinates of the signboard were determined from the signboard image to calculate the signboard's horizontal and vertical dimensions to determine the signboard's specifications. In order to determine the interior and relative orientation parameters of the stereo camera, an outdoor three-dimensional building was used as the test field. Then, the image coordinates of four vertices of the signboard were extracted from the signboard image taken from about 15m ~ 22m distance using deep learning. After determining the signboard's three-dimensional coordinates by using the interior and relative orientation parameters of the stereo camera and the image coordinates of the four vertices of the signboard, the horizontal and vertical sizes of the signboard were calculated, resulting in an error of about 2.7cm on average. The specifications for the ten flat-type signboards showed that all of the horizontal sizes were compliant with the specifications, but the vertical sizes exceeded about 36.5cm on average. Through this, it was found that maintenance of flat-type signboards is needed overall.