• Title/Summary/Keyword: Vertebral Trabecular Bone

Search Result 21, Processing Time 0.025 seconds

A Microstructural Analysis for Preventive Treatments of Vertebral Fracture (척추 골절의 예방적 치료법에 관한 미세 구조해석)

  • 김형도;탁계래;김한성;이성재
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.146-149
    • /
    • 2002
  • It is reported that the mechanical properties of vertebral trabecular bone depend on the density and the mass of bones. Osteoporosis is a systemic skeletal disease caused by low bone mass and microstructure deterioration of trabecular bone. Silva and Gibson (1997) studied the treatment of age-related bone loss using drug therapy. Vertebroplasty is a minimally invasive surgery for the treatment of osteoporosis vertebrae. This procedure includes puncturing vertebrae and filling with Polymethylmethacrylate (PMMA). However, the relative effect of drug therapy and bone cement for osteoporosis treatment is not reported yet. In this study, several 2D models of human vertebral trabecular bone are analyzed by finite element method. The mechanical behaviors of the vertebral trabecular bone treated by the drug therapy and the bone cement are compared. This study shows that bone cement treatment is more effective strategy than drug therapy to prevent the degradation of bone strength.

  • PDF

Correlation Among Permeability, Apparent Density, And Porosity of Human Lumbar Vertebral Trabecular Bone (인체 요추해면골의 배류계수, 겉보기밀도, 공극비 사이의 상관관계에 관한 연구)

  • 홍정화;강신일
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.4
    • /
    • pp.333-338
    • /
    • 1997
  • Abnormal intraosseous flow and pressure in trabecular bone could cause various pathological conditions such as osteonecrosis and osteoarthritis. Characteristics of intraosseous fluid flow and pressure generation in porous trabecular bone can be significantly affected by the permeability. Factors which determine the permeability could be the porosity and apparent density of trabecular bone. However, there is little data on the permeability and the relationship among the permeability. porosity, and apparent density of trabecular bone. In this study. the permeability. porosity, and apparent density of human lumbar vertebral trabecular bone were experimentally measured. Also, a power relationship among the permeability, porosity, and apparent density was investigated to understand effects of the porosity and apparent density variations on the permeability of trabecular bone based on Kozeny-Carman equation. A near linear relationship between intraosseous fluid flow and time indicated that the fluid phase flowed through the pores in trabecular bone is governed by the permeability. The permeability of trybecular bone was found to have a significant power relationship with the porosity and apparent density (r: 0.84 and $\textit{p}$< 0.0005). The power relationship could be useful to determine the permeability of trybecular bone after measuring the apparent density and porosity.

  • PDF

The Mechanical Characteristics of Osteoporotic Vertebral Trabecular Bone Models and its Hormone Treatment Models using 3D Micro-FE Analysis (3 차원 미세 유한요소모델을 이용한 골다공증 해면골과 호르몬 치료 모델의 기계적 특성 분석)

  • 우대곤;김한성;유용석
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1278-1281
    • /
    • 2004
  • Several workers reported the relationship between osteoporosis and age-related reductions in the BV/TV (bone volume fraction) of vertebral trabecular bones. However, there were few micro finite element (micro-FE) models to account for the treatments of the osteoporotic trabecular bone. In the present study, micro-FE models of osteoporotic and hormone-treated bone models were constructed to analyze the effect of specimen location and boundary condition on mechanical characteristics of hormone treatment model for osteoporotic trabecular bone. Top and bottom sections of specimens were also investigated individually to study the effect of specimen location. Hormone-treated models were allowed to have the same relative BV/TV (13.4%) as that used in models of previous researchers. The present study reported the elastic and plastic characteristics of the osteoporosis and hormone-treated bone models. In the present study, in-situ boundary condition was applied to the simulated compression tests for in-vivo condition of vertebral trabecular bone. The present study indicated that the hormone therapy was likely to improve the mechanical characteristics of osteoporotic bones and the mechanical characteristics of vertebral trabecular bone specimen were dependent on the captured location and boundary condition.

  • PDF

Strain Rate Dependent Poroelastic Behavior of Bovine Vertebral Trabecular Bone

  • Hong, Jung-Hwa;Mum, Mu-Seong;Lim, Tae-Hong
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.7
    • /
    • pp.1032-1040
    • /
    • 2001
  • It is widely accepted that the pressure variation of interstitial fluid is one of the most important factors in bone physiology. In order to understand the role of interstitial fluid on porous bony structure, a consideration for the biomechanical interactions between fluid and solid constituents within bone is required. In this study, a poroelastic theory was applied to investigate the elastic behavior of calf vertebral trabecular bone composed of the porous solid trabeculae and the viscous bone marrow. The poroelastic behavior of trabecular bone in a uniaxial stress condition was simulated using a commercial finite difference analysis software (FLAC, Itasca Consulting Group, USA), and tested for 5 different strain rates, i.e., 0.001, 0.01, 0.1, and 10 per second. The material properties of the calf vertebral trabecular bone were utilized from the previous experimental study. Two asymptotic poroelastic responses, the drained and undrained deformations, were predicted. From the predicted results for the simulated five strain rates, it was found that the pore pressure generation has a linearly increasing behavior when the strain rate is the highest at 10 per second, otherwise it showed a nonlinear behavior. The pore pressure generation with respect to the strain was found to be increased as the strain rate increased. The elastic moduli predicted at each strain were 208.3, 212.2, 337.6, 593.1, and 602.2 MPa, respectively. Based on the results of the present study, it was suggested that the calf vertebral trabecular bone could be modeled as a poroelastic material and its strain rate dependent material behavior could be predicted.

  • PDF

Behavior of trabecular bone considered by fluid phase and strain rate (유체상과 변형율속도를 고려한 해면골의 거동해석)

  • 민성기;홍정화;문무성;이진희
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.1078-1080
    • /
    • 2002
  • The pressure variation of interstitial fluid is one of the most important factors in bone physiology. In order to understand the role of interstitial fluid and the biomechanical interactions between fluid and solid constituents within bone, poroelastic theory was applied. The purpose of this study is to describe the behavior of calf vertebral trabecular bone composed of the porous solid trabeculae and the viscous bone marrow by using a commercial finite element analysis program based on the poroelasticity. In this study, the model was numerically tested for 5 different strain rates, i. e., 0.001, 0.01, 0.1, 1.0, and 10 per second. The material properties of the calf vertebral trabecular bone were utilized from the previous experimental study. Two asymptotic poroelastic response, the drained and undrained deformation, were predicted. From the predicted results for the simulated five strain rate, it was found that the pore pressure generation has a linearly increasing behavior when the strain rate is the highest at 10 per second, other wise it showed a nonlinear the strain rate Increased. Based on the results of the present study, it was suggested that the calf vertebral trabecular bone could be modeled as a porous material and its strain rate dependent material behavior could be predicted.

  • PDF

Classification and visualization of primary trabecular bone in lumbar vertebrae

  • Basaruddin, Khairul Salleh;Omori, Junya;Takano, Naoki;Nakano, Takayoshi
    • Advances in biomechanics and applications
    • /
    • v.1 no.2
    • /
    • pp.111-126
    • /
    • 2014
  • The microarchitecture of trabecular bone plays a significant role in mechanical strength due to its load-bearing capability. However, the complexity of trabecular microarchitecture hinders the evaluation of its morphological characteristics. We therefore propose a new classification method based on static multiscale theory and dynamic finite element method (FEM) analysis to visualize a three-dimensional (3D) trabecular network for investigating the influence of trabecular microarchitecture on load-bearing capability. This method is applied to human vertebral trabecular bone images obtained by micro-computed tomography (micro-CT) through which primary trabecular bone is successfully visualized and extracted from a highly complicated microarchitecture. The morphological features were then analyzed by viewing the percolation of load pathways in the primary trabecular bone by using the stress wave propagation method analyzed under impact loading. We demonstrate that the present method is effective for describing the morphology of trabecular bone and has the potential for morphometric measurement applications.

The elastic and plastic behaviour of the micro-FE models for vertebral trabecular bones (척추 해면골에 대한 미세 유한요소모델의 탄성 및 소성특성에 관한 연구)

  • 우대곤;김한성;원예연;백명현;탁계래
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1320-1323
    • /
    • 2003
  • In this study, the micro-FE analyses were carried out for the plastic behaviour of vertebral trabecular bones. Many researchers have investigated the elastic behaviour of trabecular bones by using the micro-finite element models based on the micro-CT images. However, there was no micro-FE model to account for the plastic behaviour of trabecular bones. Ulrich et at. reported that best results at coarser model were obtained when using 'compensated hexahedron models' with the same relative density. This study indicates that, for the elastic and plastic analysis, 'the compensated hexahedron FE model' is likely to be limited to about 63$\mu\textrm{m}$ image resolution in the vertebra trabecular bones.

  • PDF

Regional Morphological and Mechanical Characteristics in the Human Thoracic Vertebral Trabecular Bones (인체 흉추 해면골의 영역별 형태학적 및 기계적 특성 연구)

  • Lee, Tae-Woo;Woo, Dae-Gon;Ko, Chang-Young;Kim, Han-Sung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.1
    • /
    • pp.134-141
    • /
    • 2010
  • This study analyzed the regional morphological and mechanical characteristics of vertebrae by using micro-computed tomography (micro-CT) and micro finite element analysis (FEA). For the present study, the $12^{th}$ human thoracic vertebral bones (an 85-years female and a 48-years male) were used. These were scanned by using micro-CT. Structural parameters were evaluated from the acquired 20 image data for fifteen $4{\times}4mm^2$ regions (five regions in respective layers of superior, middle and inferior part) in the thoracic vertebral trabecular bones. $4{\times}4{\times}4mm^3$ cubic finite element models of each regions were created at $70{\mu}m$ voxel resolution to investigate effective modulus ($E^+$). The present study indicated that there were significant differences in morphological and elastic mechanical characteristics of each region. There are close relationship between effective modulus and structural model index (SMI) in the bone of the 48-years male and between effective modulus and bone volume fraction (BV/TV) in the bone of the 85-years female. In addition, the effective modulus of central regions is about 80% stiffer than that of lateral regions at transverse plane. These findings may be likely to explain the previous result that a change of loading distribution of the vertebral trabecular bones is caused by spinal curvature and nucleus pulpous degeneration of the intervertebral disc.