• Title/Summary/Keyword: Vertebrae

Search Result 691, Processing Time 0.024 seconds

Sigma-1 Receptor Antagonist BD1047 Reduces Allodynia and Spinal ERK Phosphorylation Following Chronic Compression of Dorsal Root Ganglion in Rats

  • Son, Ji-Seon;Kwon, Young-Bae
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.14 no.6
    • /
    • pp.359-364
    • /
    • 2010
  • Many therapeutic roles have been proposed for sigma-1 receptor (Sig-1R), but the involvement of Sig-1R in neuropathic pain has currently not been well explored. The present study aimed to evaluate the anti-nociceptive effect of Sig-1R antagonist (BD1047) in a rat model of chronic compression of the dorsal root ganglion (CCD), which is a model of human foraminal stenosis and radicular pain. When stainless steel rods were inserted into the intervertebral foramen of lumbar vertebrae 4 and 5, the CCD developed reliable mechanical (from 3 day) and cold allodynia (from 1 day) as compared with the sham operation group. The spinal expressions of Sig-1R and phosphorylation of extracellular signal-regulated kinase (pERK) were significantly increased from day 3 to day 14 after CCD surgery, as is consistent with the manifestation of allodynia. The BD 1047 (10, 30, 100 mg/kg) administered on postoperative days 0~5 dose-dependently suppressed both the induction of allodynia and the elevation of the spinal pERK expression in a manner comparable with that of gabapentin (100 mg/kg). At 7 days post-CCD surgery, BD1047 (10, 30, 100 mg/kg) administration also produced anti-nociceptive effects on the mechanical and cold allodynia similar with those of gabapentin (100 mg/kg). Therefore, this data suggested that Sig-1R may play an important role in both the development and maintenance of CCD-induced neuropathy.

Design and Manufacturing of Robotic Dolphin with Variable Stiffness Mechanism (가변강성 메커니즘을 적용한 로봇 돌고래 설계 및 제작)

  • Park, Yong-Jai
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.5
    • /
    • pp.103-110
    • /
    • 2020
  • Bio-inspired underwater robots have been studied to improve the dynamic performance of fins, such as swimming speed and efficiency, which is the most basic performance. Among them, bio-inspired soft robots with a compliant tail fin can have high degrees of freedom. On the other hand, to improve the driving efficiency of the compliant fins, the stiffness of the tail fin should be changed with the driving frequency. Therefore, a new type of variable stiffness mechanism has been developed and verified. This study, which was inspired by the anatomy of a real dolphin, assessed a process of designing and manufacturing a robotic dolphin with a variable stiffness mechanism. By mimicking the vertebrae of a dolphin, the variable stiffness driving part was manufactured using subtractive and additive manufacturing. A driving tendon was placed considering the location of the tendon in the actual dolphin, and the additional tendon was installed to change its stiffness. A robotic dolphin was designed and manufactured in a streamlined shape, and the swimming speed was measured by varying the stiffness. When the stiffness of the tail fin was varied at the same driving frequency, the swimming speed and thrust changed by approximately 1.24 and 1.5 times, respectively.

Study on the 'poems of prograde' of twelve meridians and 'poems of acupoints' (십이경맥(十二經脈)의 순행가(循行歌)와 경혈가(經穴歌)에 대(對)한 연구(硏究);십이경맥(十二經脈)의 순행(循行) 부위(部位) 및 방향(方向)과 경혈가(經穴歌)의 분류(分類)를 위주로)

  • Kang, Dong-Yun;Jo, Hak-Jun;Kim, Ho-Hyun
    • Journal of Korean Medical classics
    • /
    • v.20 no.2
    • /
    • pp.61-123
    • /
    • 2007
  • We translated 'poems of prograde' and 'poems of acupoints' which in the poems of acupoints and based on that, We considered the circulating direction and region of twelve meridian comparing the notion in common today with that in the 'poems of acupoints'. Finally, we got the conclusion like below 1. About circulating line of lung meridian, it'll be proper to correct that lung meridian passes through inner edge of biceps brachii muscle like heart and pericardium meridian. 2. On the part of kidney meridian in 'poems of prograde', it's right to be corrected as the circulating line that thru the inner line of vertebrae, enters heart and lung, and scattered tho breast. 3. 'Poems of prograde' can be separated two kinds go by starting-acupoints, ending- acupoints. First is 'poems of prograde' is begun from the end of members and ended in the body. Second is from Jungbu(中府) to Kimun(期門), circulating the members and the body with no ending. 4. On the above, we can find first 'poems of prograde' in "Chimkudaejeon(鍼灸大全)", "YangKyungjechimkujeonso(楊敬齋鍼灸全書)", "Chimkudaeseong(鍼灸大成)", also second can be found in "Neungmunjeonsudonginjihyul(凌門傳授銅人指穴)", "Chimkushinso(鍼灸神書)", "Kumchimbijeon(金針秘傳)", "Kyungrakhoepyun(經絡匯編), "Kyungrakko(經絡考)", "Jungsohoechamdongindosol(重西匯參銅人圖說)", "Kyungrakdoko(經脈圖考)", "ChimkuChuiyoung(針灸聚英)", "Shipsakyoungbalhwee(十四經發揮)", "Jakushimbopyokyul(刺灸心法要訣)", "Yukyoungdoik(類經圖翼)", "Yihakimmun(醫學入門)", etc. 5. Drawing an inference from above, the forms of "Jokbishibilmaek(足臂十一脈)" and "YumYangshibilmaek(陰陽十一脈)" are in "Mawangtoebaekso(馬王堆帛書)", are rather foreforms of circulation line that from the end of members and ended in the body than meridian prograde.

  • PDF

Balloon Kyphoplasty through Extrapedicular Approach in the Treatment of Middle Thoracic Osteoporotic Compression Fracture : T5-T8 Level

  • Kim, Hyeun-Sung;Kim, Seok-Won;Ju, Chang-Il
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.5
    • /
    • pp.363-366
    • /
    • 2007
  • Objective : Kyphoplasty performed in the middle thoracic spine presents technical challenges that differ from those in the lower thoracic or lumbar region due to small pedicle size and angular severity for thoracic kyphosis. The purpose of this study was to evaluate the efficacy of balloon kyphoplasty through extrapedicular approach for the treatment of intractable osteoporotic compression fractures in the middle thoracic spine. Methods : The patients who were performed with one level balloon kyphoplasty through extrapedicular approach due to painful osteoporotic compression fractures at T5-T8 from June 2003 to July 2005 were retrospectively analyzed. Imaging and clinical features were analyzed including involved vertebrae level, vertebral height, Injected cement volume, clinical outcome and complications. Results : Eighteen female patients (age ranged from 60 to 77 years old) were included in this study. The average amount of the implanted cement was $4.2{\pm}1.5\;cc$. The mean cobb angle and compression rate were improved from $12.1{\pm}6.5^{\circ}$ to $8.5{\pm}7.2^{\circ}$ and from 30% to 15%, respectively. The mean pain score (visual analogue scale) prior to kyphoplasty was 7.9 and it decreased to 3.0 after the procedure. Cement leakage to the adjacent disc (2 cases) and paravertebral soft tissues (1 case) were seen but there were no major complications such as pneumothorax, segmental arte 이 Injury, pulmonary embolism, or epidural leakage. Conclusion : Balloon kyphoplasty through extrapedicular approach is considered as a safe and effective in treating the middle thoracic regions with low complication rate.

Effect of Device Rigidity and Physiological Loading on Spinal Kinematics after Dynamic Stabilization : An In-Vitro Biomechanical Study

  • Chun, Kwonsoo;Yang, Inchul;Kim, Namhoon;Cho, Dosang
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.5
    • /
    • pp.412-418
    • /
    • 2015
  • Objective : To investigate the effects of posterior implant rigidity on spinal kinematics at adjacent levels by utilizing a cadaveric spine model with simulated physiological loading. Methods : Five human lumbar spinal specimens (L3 to S1) were obtained and checked for abnormalities. The fresh specimens were stripped of muscle tissue, with care taken to preserve the spinal ligaments and facet joints. Pedicle screws were implanted in the L4 and L5 vertebrae of each specimen. Specimens were tested under 0 N and 400 N axial loading. Five different posterior rods of various elastic moduli (intact, rubber, low-density polyethylene, aluminum, and titanium) were tested. Segmental range of motion (ROM), center of rotation (COR) and intervertebral disc pressure were investigated. Results : As the rigidity of the posterior rods increased, both the segmental ROM and disc pressure at L4-5 decreased, while those values increased at adjacent levels. Implant stiffness saturation was evident, as the ROM and disc pressure were only marginally increased beyond an implant stiffness of aluminum. Since the disc pressures of adjacent levels were increased by the axial loading, it was shown that the rigidity of the implants influenced the load sharing between the implant and the spinal column. The segmental CORs at the adjacent disc levels translated anteriorly and inferiorly as rigidity of the device increased. Conclusion : These biomechanical findings indicate that the rigidity of the dynamic stabilization implant and physiological loading play significant roles on spinal kinematics at adjacent disc levels, and will aid in further device development.

The Change of Bone Metabolism in Ovariectomized Rats : Analyses of MicroCT Scan and Biochemical Markers of Bone Turnover

  • Yoon, Kyung-Hyuk;Cho, Dae-Chul;Yu, Song-Hee;Kim, Kyoung-Tae;Jeon, Young-Hoon;Sung, Joo-Kyung
    • Journal of Korean Neurosurgical Society
    • /
    • v.51 no.6
    • /
    • pp.323-327
    • /
    • 2012
  • Objective : The purpose of this study was to verify the appropriateness of ovariectomized rats as the osteoporosis animal model. Methods : Twelve female Sprague-Dawley rats underwent a sham operation (the sham group) or bilateral ovariectomy [the ovariectomy (OVX) group]. Eight weeks after operations, serum biochemical markers of bone turnover were analyzed; osteocalcin and alkaline phosphatase, which are sensitive biochemical markers of bone formation, and C-terminal telopeptide fragment of type I collagen C-terminus (CTX), which is a sensitive biochemical marker of bone resorption. Bone histomorphometric parameters and microarchitectural properties of 4th lumbar vertebrae were determined by micro-computed tomographic (CT) scan. Results : The OVX group showed on average 75.4% higher osteocalcin and 72.5% higher CTX levels than the sham group, indicating increased bone turnover. Micro-CT analysis showed significantly lower bone mineral density (BMD) (p=0.005) and cortical BMD (p=0.021) in the OVX group. Furthermore, the OVX group was found to have a significantly lower trabecular bone volume fraction (p=0.002). Conclusion : Our results showed that bone turnover was significantly increased and bone mass was significantly decreased 8 weeks after ovariectomy in rats. Thus, we propose that the ovariectomized rat model be considered a reproducible and reliable model of osteoporosis.

A Morphologically Atypical Case of Atlantoaxial Rotatory Subluxation

  • Umebayashi, Daisuke;Hara, Masahito;Nishimura, Yusuke;Wakabayashi, Toshihiko
    • Journal of Korean Neurosurgical Society
    • /
    • v.55 no.5
    • /
    • pp.284-288
    • /
    • 2014
  • A rare case of atlantoaxial rotatory subluxation occurred after pediatric cervical spine surgery performed to remove a dumbbell-shaped meningioma at the level of the C1/C2 vertebrae. This case is classified as a post-surgical atlantoaxial rotatory subluxation, but has a very rare morphology that has not previously been reported. Although there are several reports about post-surgical atlantoaxial rotatory subluxation, an important point of this case is that it might be directly related to the spinal cord surgery in C1/C2 level. On day 6 after surgery, the patient presented with the Cock Robin position, and a computed tomography scan revealed a normal type of atlantoaxial rotatory subluxation. Manual reduction was performed followed by external fixation with a neck collar. About 7 months after the first surgery, the subluxation became severe, irreducible, and assumed an atypical form where the anterior tubercle of C1 migrated to a cranial position, and the posterior tubercle of C1 and the occipital bone leaned in a caudal direction. The pathogenic process suggested deformity of the occipital condyle and bilateral C2 superior facets with atlantooccipital subluxation. A second operation for reduction and fixation was performed, and the subluxation was stabilized by posterior fixation. We encountered an unusual case of a refractory subluxation that was associated with an atypical deformity of the upper spine. The case was successfully managed by posterior fixation.

Relationships among Obesity, Bone Mineral Density, and Cardiovascular Risks in Post-menopausal Women (폐경 후 여성의 비만, 골밀도와 심혈관질환 위험도 간의 관계)

  • So, Hee-Young;Ahn, Suk-Hee;Song, Rha-Yun;Kim, Hyun-Li
    • Women's Health Nursing
    • /
    • v.16 no.3
    • /
    • pp.224-233
    • /
    • 2010
  • Purpose: This study explored the relationships among obesity, bone mineral density, and cardiovascular risks in post-menopausal women. Methods: One hundred post-menopausal women were recruited via convenience sampling from osteoporosis prevention program participants who were living in a metropolitan city in September 2006. Obesity was evaluated by body mass index, bone mineral density measured by DEXA scan, and cardiovascular risk factors assessed by a guideline of American Heart Association. Results: Seventy-two percent of women were either in the osteopenia or osteoporosis group, while 28% were in normal range in lumbar vertebrae. Obese women had greater bone mineral density in lumbar (F=3.31, p=.040) and femur (F=4.72, p=.011). Variables for cardiovascular risks were significantly different for high density lipoprotein (F=7.51, p=.001), systolic blood pressure (F=5.21, p=.007), and in percent of 10-year cardiovascular disease risk according to obesity. Conclusion: Post-menopausal women are at risk for obesity, osteoporosis, and cardiovascular disease. In order to prevent these conditions, nursing interventions such as resistance and aerobic exercise that reduces body weight and bone loss, increases high density lipoprotein, and reduces systolic blood pressure, should be proposed continually through health promotion programs for postmenopausal women.

Lumbar herniated disc: spontaneous regression

  • Altun, Idiris;Yuksel, Kasim Zafer
    • The Korean Journal of Pain
    • /
    • v.30 no.1
    • /
    • pp.44-50
    • /
    • 2017
  • Background: Low back pain is a frequent condition that results in substantial disability and causes admission of patients to neurosurgery clinics. To evaluate and present the therapeutic outcomes in lumbar disc hernia (LDH) patients treated by means of a conservative approach, consisting of bed rest and medical therapy. Methods: This retrospective cohort was carried out in the neurosurgery departments of hospitals in KahramanmaraŞ city and 23 patients diagnosed with LDH at the levels of L3-L4, L4-L5 or L5-S1 were enrolled. Results: The average age was $38.4{\pm}8.0$ and the chief complaint was low back pain and sciatica radiating to one or both lower extremities. Conservative treatment was administered. Neurological examination findings, durations of treatment and intervals until symptomatic recovery were recorded. $Las{\grave{e}}gue$ tests and neurosensory examination revealed that mild neurological deficits existed in 16 of our patients. Previously, 5 patients had received physiotherapy and 7 patients had been on medical treatment. The number of patients with LDH at the level of L3-L4, L4-L5, and L5-S1 were 1, 13, and 9, respectively. All patients reported that they had benefit from medical treatment and bed rest, and radiologic improvement was observed simultaneously on MRI scans. The average duration until symptomatic recovery and/or regression of LDH symptoms was $13.6{\pm}5.4$ months (range: 5-22). Conclusions: It should be kept in mind that lumbar disc hernias could regress with medical treatment and rest without surgery, and there should be an awareness that these patients could recover radiologically. This condition must be taken into account during decision making for surgical intervention in LDH patients devoid of indications for emergent surgery.

Finite Element Analysis of a Newly Designed Screw Type Fixture for an Artificial Intervertebral Disc (새로운 방식의 나사형 인공디스크 고정체 해석)

  • Lim, Jong-Wan;Yang, Hyun-Ik
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.1
    • /
    • pp.56-66
    • /
    • 2010
  • The various total replacement artificial discs have developed because spinal fusion has shown a lesser mobility of an operated segment and an accelerated degeneration at adjacent discs. But almost artificial discs have not yet been reached on the substitute surgery of fusion because many problems such as those clinical success rates were not more than them of fusion have not solved. In this paper, vertically inserted assemble-screw fixture in vertebrae was proposed to improve the fixed capability of artificial disc. And also, to evaluate the design suitability of newly designed screw-type, including fixtures of commercial discs such as wedge and plate type, the 1/4 finite element model with a vertebra and various implanted fixtures were generated, and next, 3 bending motions such as flexion, bending and twisting under the moment of 10Nm and compression under the force of 1000N were considered, respectively and finally, FE analyses were performed. Results of three fixture types were compared, such as Range of Motion and maximal stress, and so on. For ROM, the screw type was average 58% less than the wedge type and was average 42% less than the plate type under all loading conditions. For average stress ratio at closer nodes between vertebra and each fixture, the wedge type was the lowest as minimum 0.02 in twisting, screw types were the highest as maximum 0.28 in compression. As the results of using cement material, it was predicted that the instability problem of the wedge type was better solved. The screw type which could be increased by implanting depth according to the number of assembling mid screws, showed that the decreased tendency of ROMs and maximal cancellous bone stresses. In further study, controlling the number of assembling screws that was suitable for a patient's bone quality, development of surgical tools and keeping on design supplementations, which will be able to develop the competitive artificial disc.