• Title/Summary/Keyword: Vents

Search Result 143, Processing Time 0.029 seconds

Three-dimensional natural convection cooling of the electronic device with the effects of convective heat dissipation and vents (전자장비에서 벽면의 대류열방출 및 통기구의 효과를 고려한 3차원 자연대류 냉각)

  • ;;;Baek, Chang-In;Lim, Kwang-Ok
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.11
    • /
    • pp.3072-3083
    • /
    • 1995
  • The numerical simulation on the three-dimensional natural convection heat transfer in the enclosure with heat generating chip is performed, and the effects of convective heat loss and vents are also examined. The effects of the Rayleigh number and outer Nusselt number (Nu$_{0}$) on the maximum chip temperature and the fractions of heat loss from the hot surfaces are investigated. The results show that conduction through the substrate is dominant in heat dissipation. With the increase of Rayleigh number, heat dissipation through the chip surfaces increases and heat loss through the substrate decreases. Maximum dimensionless temperature with vents is found to decrease about 40% compared to the one without vents at Nu$_{0}$=0.l. It is also shown that effects of size and location of the vents are negligible.ble.

A Study on the Characteristics of Cross-contamination according to the Size and Separation distance of Exterior Air-vents (실외 급배기구 크기와 이격거리에 따른 교차오염 특성연구)

  • Moon, Yong-Jun;Noh, Kwang-Chul;Oh, Myung-Do
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.393-398
    • /
    • 2006
  • This study is undertaken to evaluate the characteristics of cross contamination around exterior air-vents. A CFD analysis has been performed to calculate the cross contamination index for five exterior air-vents sizes according to the outdoor air velocity and separation distance of it. From the result of the numerical method, As the outdoor air velocity is increased, the cross contamination index is increased. on the contrary, as the separation distance of exterior air-vents is increased, the cross contamination index is decreased, additionally the cross contamination is affected by the aspect ratio of the size of exterior Air-vents.

  • PDF

Optimal design of escape vent for the dome type coonstrip shrimp (Pandalus hypsinotus) pot (반구형 도화새우통발에 있어서 적정 탈출구의 설계)

  • Kim, Seong-Hun;Lee, Ju-Hee;Kim, Hyung-Seok;Park, Seong-Wook
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.46 no.2
    • /
    • pp.115-125
    • /
    • 2010
  • In order to design the optimal escape vent for the coon strip shrimp pot, the tank experiments were conducted with the model pot of five different slit height and slit width, respectively. The optimal height and width of escape vent were determined to 20mm and 40mm by tank experiments, respectively. These were determined by the 50% selection carapace length which was denoted to 25mm in selectivity curve. The escape experiments were conducted to determine a number of escape vent with the original shrimp pot to be set the designed escape vent from 2 vents to 10 vents increasing at intervals of 2 vents in tank. The optimal number of escape vents denoted 8 vents. Therefore, to apply the escape vent in commercial shrimp pot will be efficient to reduce small size shrimps to catch.

Numerical study for smoke behavior in case of train fires in railway tunnel with axial fan vents (강제환기 통풍구가 설치된 철도터널 열차화재에서 연기거동에 관한 수치해석적 연구)

  • Kim, Dong-Hyeon;Shin, Min-Ho;Moon, Jung-Joo
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1998-2004
    • /
    • 2003
  • Numerical study were performed to analyze for fire safety in railway tunnel with forced ventilation vents. For the condition of train fires with heat release rate of 30 MW, unsteady three dimensional analysis were carried out to investigate the effects of smoke movements, the heat transfer and $CO_2$ concentrations and in double track tunnel with two vents. Among three operation modes of forced ventilations at two vents, the exhaust-exhaust mode of the vent represents the best performance for the evacuation of passengers to avoid the fire.

  • PDF

The Optimal Design of Vents using Linear Analysis (선형해석을 이용한 방열그릴(GRILLE)최적설계)

  • Choi, Yong-Hwan;Joe, Yeo-Uk
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.326-332
    • /
    • 2000
  • It should be essentially considered as important points that design of case in electronic product which simultaneously satisfied with structural stability and molding form in respect to developmental period and economical aspect. Especially, a shape of air vents grille, which is made to emit heat happen to be in the internal of product, must satisfy durability and strength but We have no quantitative data because to be done by experience of designer. So, in this study, We will propose that structure of optimal and method of design in air vents grille, which to reduce a lot of loss of time and cost due to trial and error of design and to stabilize in the BALLISTIC Impact test as to estimate strength with external appearance of product, using linear analysis.

  • PDF

Roof Ventilation Structures and Ridge Vent Effect for Single Span Greenhouses of Arch Shape (아치형 단동온실의 지붕환기구조 및 천창효과)

  • Nam, Sang-Woon
    • Korean Journal of Agricultural Science
    • /
    • v.28 no.2
    • /
    • pp.99-107
    • /
    • 2001
  • It is difficult to install a ventilation window on the roof of single span greenhouses of arch shape. Investigation on the roof ventilation structures for those greenhouses was conducted. In small greenhouses with spans of 5 to 8 m, circular or chimney type ridge vents made of plastic were employed. In large greenhouses with spans of 12 to 18 m, even span roll-up ridge vents made of steel pipe were employed. The effect of roof ventilation was evaluated by comparative experiments between greenhouse installing ridge vents and having controlled side vents only. Roof ventilation contributed greatly to restraint of temperature rise and maintenance of uniform temperature distribution in greenhouses. And ventilation efficiency was analyzed by experiments on the opening and closing operation of the ridge and side vent. There were no temperature differences according to opening and closing sequence of ventilation window. But for greenhouse temperature control by ventilation, it is desirable to open side vents after ridge vents and to close ridge vents after side vents.

  • PDF

Evaluation of Natural Ventilation Performance for Multi-span Plastic Greenhouses (다연동 플라스틱 온실의 자연환기성능 평가)

  • Nam, Sang-Woon;Kim, Young-Shik;Seo, Dong-Uk
    • Journal of Bio-Environment Control
    • /
    • v.22 no.1
    • /
    • pp.7-12
    • /
    • 2013
  • Environmental measurements in the many different types of horticultural farms were carried out to evaluate the ventilation performance for multi-span plastic greenhouses according to the eaves height, the number of spans, the existence of side wall vents and the position of roof vents. Hydroponic tomatoes were being cultivated in all experimental greenhouses, and ventilation rates of the greenhouses were analyzed by the heat balance method. It showed that the ventilation rate in the greenhouse with 4 m eaves height increased about 22% compared to the greenhouse with 2 m eaves height. The ventilation rate in the greenhouse with 9 spans decreased about 17% compared to the greenhouse with 5 spans. In the greenhouse with 9 spans, if there were no side wall vents, the ventilation rate showed about a third of the case that side wall vents were open. Overall, as the eaves height was higher and the number of spans was smaller in multi-span greenhouses, the natural ventilation performance was better. And the ventilation performance was best in the greenhouse which the eaves height was high and the position of roof vents was ridge, not gutter. Therefore, in order to maximize the natural ventilation performance, multi-span plastic greenhouses need to improve their structures such as that make the eaves height higher, place the roof vents on the ridge, install the side wall vents as much as possible, and the number of spans is limited to about 10 spans.

Deep-sea Hydrothermal Vents: Ecology and Evolution

  • Won, Yong-Jin
    • Journal of Ecology and Environment
    • /
    • v.29 no.2
    • /
    • pp.175-183
    • /
    • 2006
  • The discovery of deep-sea hydrothermal vents and their ecosystems is a monumental landmark in the history of Ocean Sciences. Deep-sea hydrothermal vents are scattered along the global mid-ocean ridges and back-arc basins. Under sea volcanic phenomena related to underlying magma activities along mid-ocean ridges generate extreme habitats for highly specialized communities of animals. Multidisciplinary research efforts during past three decades since the first discovery of hydrothermal vents along the Galapagos Rift in 1977 revealed fundamental components of physiology, ecology, and evolution of specialized vent communities of micro and macro fauna. Heterogeneous regional geological settings and tectonic plate history have been considered as important geophysical and evolutionary factors for current patterns of taxonomic composition and distribution of vent faunas among venting sites in the World Ocean basins. It was found that these communities are based on primary production of chemosynthetic bacteria which directly utilize reduced compounds, mostly $H_2S$ and $CH_4$, mixed in vent fluids. Symbioses between these bacteria and their hosts, vent invertebrates, are foundation of the vent ecosystem. Gene flow and population genetic studies in parallel with larval biology began to unveil hidden dispersal barrier under deep sea as well as various dispersal characteristics cross taxa. Comparative molecular phylogenetics of vent animals revealed that vent faunas are closely related to those of cold-water seeps in general. In perspective additional interesting discoveries are anticipated particularly with further refined and expanded studies aided by new instrumental technologies.

A Study on Improvement of the Roof Vents in the Arcade Traditional Market (아케이드형 재래시장의 지붕 환기구 개선 방안에 관한 연구)

  • Ma, Jun Chao;Lee, Byung Hyun;Lee, Kyung Hee
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.30 no.1
    • /
    • pp.17-23
    • /
    • 2018
  • A fire simulation was performed to analyze the temperature and smoke exhaust performance of roof vents of the arcade traditional market by comparing a basic model (Case A) and an improvement model (Case B~Case E). Temperature analysis by heat showed a low temperature distribution because Case E discharged smoke in both directions of length compared to other cases. However, the effect of heat by life safety standards was satisfied. The smoke exhaust analysis by smoke showed the highest performance because Case C was exhausted to 1 m on both sides of length.

Analysis of Natural Ventilation Characteristics of Venlo-type Greenhouse with Continuous Roof Vents (연속형 천창을 가진 벤로형 온실의 자연환기 특성 분석)

  • Kwon, Jin-Kyeong;Lee, Sung-Hyun;Seong, Jae-Hoon;Moon, Jong-Pil;Lee, Soo-Jang;Choi, Byeong-Min;Kim, Kyeong-Ja
    • Journal of Biosystems Engineering
    • /
    • v.36 no.6
    • /
    • pp.444-452
    • /
    • 2011
  • In this study the characteristics of natural ventilation of Venlo-type greenhouse with continuous roof vents were analyzed using commercial computational fluid dynamics (CFD) code. Developed CFD simulation model was verified by comparison with experimental data. Simulation errors were 1.9-46.0% for air velocity and 1.7-11.2% for air temperature at each measurement point. CFD simulations were conducted to estimate the effect of roof vents opening direction, opening angle, outside wind velocity and wind directions on ventilation rate and climate condition in greenhouse. The results of this study showed that ventilation rate of the present greenhouse was increased linearly in proportion to the increase of roof vent opening angle and outside wind velocity over 2.0 m/s. According to the analysis on the effects of different roof vent opening direction, simultaneous opening of wind and leeward vents showed the highest ventilation rate and lowest mean temperature in greenhouse.