• Title/Summary/Keyword: Ventricular function, left

Search Result 259, Processing Time 0.024 seconds

Effect of Left Ventricular Diastolic Function on Exercise Capacity in Hypertensive Patients with Obesity (비만을 동반한 고혈압 환자의 좌심실 이완기 기능이 운동능력에 미치는 영향)

  • Shin, Kyung-A
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.8
    • /
    • pp.269-278
    • /
    • 2020
  • The purpose of this study was to investigate the effect of left ventricular diastolic function on exercise capacity in hypertensive patients with obesity compared to the obese group. Adults who visited a general hospital in Gyeonggi-do from 2016 to 2019(man: 308, women: 192) were divided into 4 groups according to hypertension and obesity. In the hypertensive obesity group(IV), the A wave and E/E' wave were significantly higher than the normotensive obesity group(II), and the E' wave was significantly lower(respectively p<0.001). The group IV had significantly lower METS(metabolic equivalents) and exercise duration than the group II(respectively p<0.001). In group IV, E/A ratio was positively correlated with METS(p=0.025) and exercise duration(p=0.026). In contrast, E/E' wave in these groups showed a negative correlation with the exercise duration(p=0.046).

Biases in the Assessment of Left Ventricular Function by Compressed Sensing Cardiovascular Cine MRI

  • Yoon, Jong-Hyun;Kim, Pan-ki;Yang, Young-Joong;Park, Jinho;Choi, Byoung Wook;Ahn, Chang-Beom
    • Investigative Magnetic Resonance Imaging
    • /
    • v.23 no.2
    • /
    • pp.114-124
    • /
    • 2019
  • Purpose: We investigate biases in the assessments of left ventricular function (LVF), by compressed sensing (CS)-cine magnetic resonance imaging (MRI). Materials and Methods: Cardiovascular cine images with short axis view, were obtained for 8 volunteers without CS. LVFs were assessed with subsampled data, with compression factors (CF) of 2, 3, 4, and 8. A semi-automatic segmentation program was used, for the assessment. The assessments by 3 CS methods (ITSC, FOCUSS, and view sharing (VS)), were compared to those without CS. Bland-Altman analysis and paired t-test were used, for comparison. In addition, real-time CS-cine imaging was also performed, with CF of 2, 3, 4, and 8 for the same volunteers. Assessments of LVF were similarly made, for CS data. A fixed compensation technique is suggested, to reduce the bias. Results: The assessment of LVF by CS-cine, includes bias and random noise. Bias appeared much larger than random noise. Median of end-diastolic volume (EDV) with CS-cine (ITSC or FOCUSS) appeared -1.4% to -7.1% smaller, compared to that of standard cine, depending on CF from (2 to 8). End-systolic volume (ESV) appeared +1.6% to +14.3% larger, stroke volume (SV), -2.4% to -16.4% smaller, and ejection fraction (EF), -1.1% to -9.2% smaller, with P < 0.05. Bias was reduced from -5.6% to -1.8% for EF, by compensation applied to real-time CS-cine (CF = 8). Conclusion: Loss of temporal resolution by adopting missing data from nearby cardiac frames, causes an underestimation for EDV, and an overestimation for ESV, resulting in underestimations for SV and EF. The bias is not random. Thus it should be removed or reduced for better diagnosis. A fixed compensation is suggested, to reduce bias in the assessment of LVF.

Accuracy of Ventricular Volume and Ejection Fraction Measured by Gated Tl-201 Perfusion Single Photon Emission Tomography (심전도 게이트 심근관류 Tl-201 SPECT로 측정된 좌심실 기능 및 좌심실 용적의 정확성)

  • Pai, Moon-Sun;Moon, Dae-Hyuk
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.2
    • /
    • pp.94-99
    • /
    • 2005
  • Electrocardiogram-gated single photon omission computed tomography (SPECT) provides valuable information in the assessment of both myocardial perfusion and ventricular function. Tl-201 is a suboptimal isotope for gating. Tl-201 images are more blurred compared with Tc-99m tracers due to the increased amount of scattered photons and use of a smooth filter. The average myocardial count densities are approximately one-half those of conventional technetium tracers. However, Tl-201 is still widely used because of its well-established utility for assessing myocardial perfusion, viability and risk stratification. Gated SPECT with Tl-201 enables us to assess both post-stress and rest left ventricular volume and function. Previous studies with gated Tl-201 SPECT measurements of ejection fraction (EF), end-diastolic volume (EDV), end-systolic volume (ESV) have shown high correlation with first-pass radionuclide angiography, gated blood pool scan, Tc-99m-MIBI gated SPECT, contrast ventriculography, echocardiography, and 3-dimensional magnetic resonance imaging. However, problems related to these studies include few agreement data of EDV and ESV, use of a reference method that is likely to have the same systemic errors (gated Tc-99m-MIBI SPECT), and other technical factors related to the count density of gated SPECT. With optimization of gated imaging protocols and more validation studies, gated Tl-201 SPECT would be an accurate method to provide perfusion and function information in patients with coronary artery disease.

Evaluation of Left Ventricular Tei Index in the Normal Dogs and Dogs with Mitral Valve Degenerative Disease (정상 및 퇴행성이첨판 질환이 있는 개에서 조직도플러를 통한 좌심실 Tei index의 평가)

  • Lee, In;Lee, Jung-Woo;Choi, Soo-Young;Han, Woo-Sok;Lee, Ki-Ja;Lee, Young-Won;Choi, Ho-Jung
    • Journal of Veterinary Clinics
    • /
    • v.32 no.2
    • /
    • pp.162-167
    • /
    • 2015
  • Tei-index has been reported as one of reliable echocardiographic factors for evaluating cardiac function in human and small animals. In this study, Tei-index were measured and evaluated with other echocardiographic parameters in normal thirteen beagle dogs and thirty-one dogs with mitral valve degeneration. Normal range of Tei index with tissue Doppler obtained at septum and left ventricular free wall was $0.58{\pm}0.07$ and $0.60{\pm}0.07$, respectively. The values between septum and left ventricular free wall did not show significant difference. Tissue Doppler derived tei index showed better reproducibility and significantly lower values than the results obtained by pulsed wave Doppler. Tei index obtained in either method increased with the progression of clinical signs. Therefore, the increase of Tei index in dogs with mitral regurgitation is thought to be an useful factor reflecting left ventricular dysfunction.

Analysis of Left Ventricular Functional Parameters in Normal Korean Subjects by ECG Gated Blood Pool Scan (정상 한국인에서 게이트혈액풀스캔을 이용한 좌심실 심기능지표들의 분석)

  • Kang, Jae-Hwang;Park, Une-Sook;Kang, Byeong-Sun;Lim, Hyeon-Ok;Choi, Dong-Soo;Suh, Bong-Kwan;Chung, Soon-Il;Lee, Keun-Woo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.1
    • /
    • pp.52-61
    • /
    • 1994
  • Background : The demand for refinement in noninvasive and quantitative assessment of left ventricular (LV) function is increasing. Purpose : To assess normal values of left ventricular functional parameters during both systole and diastole by scintigraphic method using computerized triple-head gamma camera and to evaluate correlations between these parameters. Methods : ECG gated blood pool scan with $^{99m}Tc$-Human serum albumin was performed in 94 normal Korean subjects. Ejection fraction (EF), systolic parameters [peak emptying rate (PER), average emptying rate (AER), time to peak emptying rate (TPER)], and diastolic parameters [peak filling rate (PFR), average filling rate (AFR), time to peak filling rate (TPFR)] were obtained by analysis of LV time-activity curve, the correlation of these parameters to the age and sex, and the correlation between these parameters were evaluated. Results : 1) Mean value of ejection fraction in study subjects was $59.6{\pm}5.25%$ and showed no significant correlation to age (r=-0.08) and sex but showed most pronounced correlation to PFR (r=0.46, p<0.001), PER (r=0.41, p<0.001), AFR (r=0.34, p<0.001) and AER (r=0.28, p<0.01). 2) Mean values of systolic parameters were as follows: $PER=3.22{\pm}0.50$ end-diastolic volume/sec, $AER=2.22{\pm}0.45$ end-diastolic volume/sec, $TPER=103.5{\pm}29.30$ msec. They showed no significant correlation to age and sex. 3) Mean values of diastolic parameters were as follows: $PFR=2.71{\pm}0.51$ end-diastolic volume/sec, $AFR=1.83{\pm}0.44$ end-diastolic volume/sec, $TPFR=132.1{\pm}33.45$ msec. They showed strong correlation to age (r=0.70, -0.64, 0.37, p<0.001). Conclusions : Left ventricular functional parameters in normal Korean subjects were obtained reliably by computerized scintigraphic method and may be applied to the evaluation of cardiac function in diseased patients.

  • PDF

Acute Hemodynamic Effects of CJ-10513, an Angiotensin IIReceptor Antahonest, in Dog Treated with High Friquency Ventricular Pacing (안지오텐신 ll 수용체 길항약 CJ-10513이 고민도 심실 pacing 천에서의 혈행동태에 미치는 영향)

  • Kim, Young-Hoon;Jeong, Seong-Mok;Shin, Jae-Kyu;Choi, Jae-Mook;Jeong, Seong-Hak;Bae, Hoon;Lee, Gun-Ho;Kim, Je-Hak;An, Yang-Soo
    • Biomolecules & Therapeutics
    • /
    • v.6 no.2
    • /
    • pp.199-203
    • /
    • 1998
  • Acute hemodynamic effects of CJ-18513, a non-peptide angiotensin IIreceptor antagonist, were examined in mongrel dogs treated with high frequency ventricular pacing for one week. Rapid ventricular pacing reduced mean blood pressure (mBP), Lvdp/dt and cardiac output (CO), and increased the left ventricular end-diastolic pressure (LVEDP) and pulmonary capillary wedge pressure (PCWP). Continuous infusion of CJ-10513 at doses of 10 and 20$\mu$g/kg/min, respectively, for 30 minutes reduced mBP, LVEDP and myocardial oxygen consumption rate (MVO,) and shifted the cardiac function curve (CO-LVEDP ourve) to the left in this dog model. In conclusion, CJ-10513 decreased the preload and afterload and increased the cardiac function in dogs with pacing-induced heart failure.

  • PDF

Total Occlusion of the Left Main Coronary Artery

  • Pezzella, Thomas;Giambatrolomi, Alessandro;Esente, Paolo;Gensini, Goffredo G.
    • Journal of Chest Surgery
    • /
    • v.20 no.2
    • /
    • pp.342-347
    • /
    • 1987
  • Complete occlusion of the main LCA is associated with a poor prognosis if the RCA becomes severely occluded. The functional role of collateral circulation is critical in this situation. This study lends support to the hypothesis that coronary collateral circulation can provide critically needed myocardial blood flow via right to left collaterals. Not surprisingly, left ventricular function was maintained in 4 of the 5 patients studied who had main LCA occlusion and well-developed collateral circulation.

  • PDF

Correlation Between Left Ventricular Peak Systolic Pressure/End-Systolic Volume Ratio and Symptomatic Improvement with Valve Replacement in Patients with Aortic Regurgitation and Enlarged End-Systolic Volume (대동맥판역류증과 좌심실수축말기용적 확장이 있는 환자에서 좌심실최고수축기압/수축말기용적비와 판막치환후의 증상적 호전과의 관계)

  • Kim, Woong-Han;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.29 no.8
    • /
    • pp.867-874
    • /
    • 1996
  • This study was designed to assess the left ventricular peak systolic pressure/end-systolic volume (PSP/ESV) ratio in predicting symptomatic improvement with valve replacement in patients with aortic regurgitation and enlarged left von'lrlcular volume. We studied 21 patients (15 men and 6 women aged 15 to 60 years) with moderate or severe aortic regur- gitation, no other cardiovascular abnormalities and left ventricular end-systolic volume over 60 m11m2. In this group we assessed the preoperative variables which routinely were measured at cardiac catheterlzation to predict symptomatic improvement with valve replacement. Six months after operation, symptoms were alleviated in 13 patients(62%), and unchanged in 8()8%). By multivariate analysis, the PSP/ESV rati was a strong predictor for functional class 6 months after surgery(p=0.005) and also for change- in functional class prior to an operation to 6 months postoperatively(p=0.0)2). By 6 months after receiving valve replacement, all patients with a ratio over 1. 71 mmHglml/m'were in functional class I or II , in contrast, of those with a ratio < 1.71 mmHg/ml/m2, 40% were in functional class III. The PSP/ESV ratio may help to predict which patients with aortic regurgitation and enlarged left ven- tricular end-systolic volume will have symptomatic improvement with valve replacement.

  • PDF

Hypothermia Improves Outcomes of Cardiopulmonary Resuscitation After Cardiac Arrest In a Rat Model of Myocardial Infarction (심근경색에 의한 심정지 후 치료적 저체온증으로 호전된 쥐의 심폐소생술 모델)

  • Roh, Sang-Gyun;Kim, Jee-Hee;Moon, Tae-Young;Park, Jeong-Hyun
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.12a
    • /
    • pp.170-173
    • /
    • 2011
  • Therapeutic hypothermia(TH) improves neurological outcomes and reduces mortality among survivors of out-of-hospital cardiac arrest. Animal and human studies have shown that TH results in improved salvage of the myocardium, reduced infarct size, reduced left ventricular remodeling and better long-term left ventricular function in settings of regional myocardial ischemia. This study is to investigate the effect of TH on post-resuscitation myocardial dysfunction and survival time after cardiac arrest and resuscitation in a rat model of myocardial infarction (MI). Thoracotomies were performed in 10 Male Sprague-Dawley rats weighing 450-550 g. MI was induced by ligation of the left anterior descending coronary artery (LAD). Ninety min after LAD ligation, ventricular fibrillation induction and subsequent cardiopulmonary resuscitation was performed before defibrillation attempts. Animals were randomized to two groups: a) Acute MI-Normothermia b) Acute MI-Hypothermia ($32^{\circ}C$ for 4 h). Myocardial functions, including cardiac output, left ventricular ejection fraction, and myocardial performance index were measured echocardiographically together with duration of survival. Ejection fraction, cardiac output and myocardial performance index were $54.74{\pm}9.16$, $89.00{\pm}8.89$, $1.30{\pm}0.09$ respectively and significantly better in the TH group than those of the normothermic group at the first 4 h after resuscitation($32.20{\pm}1.85$,$41.60{\pm}8.62$,$1.77{\pm}0.19$)(p=0.00). The survival time of the hypothermic group ($31.8{\pm}14.8$ h) was greater than that of the normothermic group($12.3{\pm}6.5$ h, p<0.05). This study suggested that TH attenuated post resuscitation myocardial dysfunction in acute MI and would be a potential strategy in post resuscitation care.

  • PDF

Evaluation of Classification Models of Mild Left Ventricular Diastolic Dysfunction by Tei Index (Tei Index를 이용한 경도의 좌심실 이완 기능 장애 분류 모델 평가)

  • Su-Min Kim;Soo-Young Ye
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.5
    • /
    • pp.761-766
    • /
    • 2023
  • In this paper, TI was measured to classify the presence or absence of mild left ventricular diastolic dysfunction. Of the total 306 data, 206 were used as training data and 100 were used as test data, and the machine learning models used for classification used SVM and KNN. As a result, it was confirmed that SVM showed relatively higher accuracy than KNN and was more useful in diagnosing the presence of left ventricular diastolic dysfunction. In future research, it is expected that classification performance can be further improved by adding various indicators that evaluate not only TI but also cardiac function and securing more data. Furthermore, it is expected to be used as basic data to predict and classify other diseases and solve the problem of insufficient medical manpower compared to the increasing number of tests.