• 제목/요약/키워드: Ventricular ejection fraction

Search Result 210, Processing Time 0.021 seconds

Comparison of the Ejection Fraction Between Gated Blood Pool, Gated Blood Pool SPECT and Echocardiography (게이트심장혈액풀스캔과 게이트심장혈액풀 SPECT로 측정한 심박출계수의 심초음파와의 비교 연구)

  • Jeong, Ji-Uk;Lee, Hyo-Yeong;Yun, Jong-Jun;Lee, Hwa-Jin;Lee, Moo-Seok;Song, Hyeon-Seok;Park, Se-Yun;Kim, Jae-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.150-154
    • /
    • 2010
  • Purpose: Ejection fraction (EF) is one of the most important factors that evaluate heart function. Recently, according to echocardiography and myocardial perfusion SPECT, the number of gated blood pool scan (planar GBP) is declining. Measurement of left ventricular ejection fraction using gated blood pool SPECT (GBPS) is known as relatively correspond with echocardiography. We compared EF derived from plnar GBP, GBPS and echocadiography using modified simpson method to determine the accuracy. Materials and Methods: From January 2007 to June 2010, planar GBP and GBPS were performed on 34 patients who admitted to Pusan National University Hospital (men 23, women 11, mean age $52.6{\pm}27.2$). Each patient was injected with $^{99m}{TcO_4}^-$ of 20 mCi after pyrophosphate injection and then scanned using both planar GBP and GBPS techniques. For image analysis, we use ADAC Laboratories, Ver. 4.20 software. The result analyzed was processed by SPSS 17.0 Win statistic program and statistical method applied in data analysis is one-way anova, Tukey's post hoc test, pearson correlation test. Results: One-way anova test show no significant difference (planar GBP $56.3{\pm}13.9%$; GBPS $60.4{\pm}16.0%$; echocardiography $59.1{\pm}14.4%$, p=0.486, p>0.05). Tukey's post hoc test show no significant difference (planar GBP-echocardiography p=0.697; GBPS-echocardiography p=0.928; planar GBP-GBPS p=0.469, p>0.05). Values for EF obtained with planar GBP and GBPS correlated well with those obtained with echocardiography (planar-echocardiography r=0.697; GBPS-echocardiography r=0.928; planar GBP-GBPS r=0.469). Conclusion: The problems of accuracy and reproducibility for planar GBP still remain. But planar GBP is a safe and non-invasive method. In addition, planar GBP is useful to evaluate patient with low resolution echocardiography images. GBPS is not appicated clinically. but GBPS can be obtain various left ventricular functional parameters. planar GBP, GBPS and echocardiography show a good correlation between each other. Therefore, planar GBP and GBPS are useful for evaluating left ventricular ejection fraction.

  • PDF

A Study on the Left Ventricular Wall Motion with EKG Gated Cardiac Blood Pool Scan (방사성동위원소(放射性同位元素) gated cardiac blood pool scan을 이용(利用)한 좌심실벽(左心室壁) 운동(運動)에 관(關)한 연구(硏究))

  • Ahn, Yong-Tae;Kim, Byung-Tae;Park, Young-Bae;Lee, Myung-Chul;Cho, Bo-Youn;Seo, Jung-Don;Lee, Young-Woo;Koh, Chang-Soon;Lee, Mun-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.17 no.2
    • /
    • pp.25-33
    • /
    • 1983
  • Left ventricular wall motion was observed with EKG gated cardiac blood pool scan in 71 various cardiac diseases and 10 normal controls to evaluate its diagnostic and clinical significance in them. 1) In the presence of left ventricular dysfunction, visual evaluation of the left ventricular wall motion was useful to determine whether it was due to localized or diffuse abnormalities. In cardiomyopathy, marked left ventricular dilatation and severe hypokinesia were noted. 2) In myocardial infarction, regional wall motion abnormalities well represented the location of infarcted areas in majority of cases. Patients with inferior wall infarction had smaller decrease of the left ventricular ejection fraction and wall motion grade than anterior or combined groups. In whom persistent left ventricular failure was present, wall motion analysis with gated cardiac scan provided valuable information for the detection of ventricular aneurysms. 3) Evaluation of the left ventricular wall motion and its grading provided a reliable estimate of the left ventricular function. In conclusion, visual evaluation of left ventricular wall motion and its grading provided valuable information for analyzing the characteristics of regional and global left ventricular dysfunction.

  • PDF

Korean Society of Heart Failure Guidelines for the Management of Heart Failure: Definition and Diagnosis

  • Jae Yeong Cho ;Dong-Hyuk Cho;Jong-Chan Youn;Darae Kim;Sang Min Park;Mi-Hyang Jung;Junho Hyun;Jimi Choi;Hyun-Jai Cho;Seong-Mi Park;Jin-Oh Choi;Wook-Jin Chung;Byung-Su Yoo;Seok-Min Kang;Committee of Clinical Practice Guidelines, Korean Society of Heart Failure
    • Korean Circulation Journal
    • /
    • v.53 no.4
    • /
    • pp.195-216
    • /
    • 2023
  • The Korean Society of Heart Failure guidelines aim to provide physicians with evidence-based recommendations for diagnosing and managing patients with heart failure (HF). In Korea, the prevalence of HF has been rapidly increasing in the last 10 years. HF has recently been classified into HF with reduced ejection fraction (EF), HF with mildly reduced EF, and HF with preserved EF (HFpEF). Moreover, the availability of newer therapeutic agents has led to an increased emphasis on the appropriate diagnosis of HFpEF. Accordingly, this part of the guidelines will mainly cover the definition, epidemiology, and diagnosis of HF.

Clinical and Imaging Parameters Associated With Impaired Kidney Function in Patients With Acute Decompensated Heart Failure With Reduced Ejection Fraction

  • In-Jeong Cho;Sang-Eun Lee;Dong-Hyeok Kim;Wook Bum Pyun
    • Journal of Cardiovascular Imaging
    • /
    • v.31 no.4
    • /
    • pp.169-177
    • /
    • 2023
  • BACKGROUND: Acute worsening of cardiac function frequently leads to kidney dysfunction. This study aimed to identify clinical and imaging parameters associated with impaired kidney function in patients with acute decompensated heart failure with reduced ejection fraction (HFrEF). METHODS: Data from 131 patients hospitalized with acute decompensated HFrEF (left ventricular ejection fraction, < 40%) were analyzed. Patients were divided into two groups according to the glomerular filtration rate (GFR) at admission (those with preserved kidney function [GFR ≥ 60 mL/min/1.73 m2] and those with reduced kidney function [GFR < 60 mL/min/1.73 m2]). Various echocardiographic parameters and perirenal fat thicknesses were assessed by computed tomography. RESULTS: There were 71 patients with preserved kidney function and 60 patients with reduced kidney function. Increased age (odds ratio [OR], 1.07; 95% confidence interval [CI], 1.04-1.12; p = 0.005), increased log N-terminal pro b-type natriuretic peptide (OR, 1.74; 95% CI, 1.14-2.66; p = 0.010), and increased perirenal fat thickness (OR, 1.19; 95% CI, 1.10-1.29; p < 0.001) were independently associated with reduced kidney function, even after adjusting for variable clinical and echocardiographic parameters. The optimal average perirenal fat thickness cut-off value of > 12 mm had a sensitivity of 55% and specificity of 83% for kidney dysfunction prediction. CONCLUSIONS: Thick perirenal fat was independently associated with impaired kidney function in patients hospitalized for acute decompensated HFrEF. Measurement of perirenal fat thickness may be a promising imaging marker for the detection of HFrEF patients who are more susceptible to kidney dysfunction.

Effects of alfaxalone on echocardiographic examination in healthy dogs

  • Kim, Ye-Won;Kim, Tae-Jun;Hyun, Changbaig
    • Korean Journal of Veterinary Research
    • /
    • v.55 no.4
    • /
    • pp.221-225
    • /
    • 2015
  • This study evaluated the effects of alfaxalone (3 mg/kg, intravenously) on echocardiographic examination in healthy dogs using echocardiography. Six adult Beagle dogs were used for this study. Left ventricular dimensions with systolic indexes, trans-blood flow at all cardiac valvular annulus and trans-mitral tissue Doppler values were measured from routine transthoracic echocardiography. Although the changes were not statistically significant, heart rate, left ventricular end-systolic diameter, left ventricular end-diastolic diameter, peak velocities of tricuspid A-wave and transpulmonic flow were increased after alfaxalone induction, while systolic blood pressure, fractional shortening, left ventricular ejection fraction, peak velocities of mitral E-wave, mitral A wave, tricuspid E-wave, transaortic flow and medial e'-, a'- and s'-peaks decreased after alfaxalone induction. No dogs showed hypoxemia during sedation, regardless of intubation and oxygen supply. Although alfaxalone showed mild cardiovascular depression, this protocol could be a good alternative sedative protocol for echocardiographic examination in healthy dogs because the cardiovascular depression was statistically and clinically insignificant. However, further studies in dogs with heart diseases should be conducted to confirm these findings after alfaxalone induction.

Successful Bridge to Heart Transplantation through Ventricular Assist Device Implantation and Concomitant Fontan Completion in a Patient with Glenn Physiology: A Case Report

  • Ji Hong Kim;Ji Hoon Kim;Ah Young Kim;Yu Rim Shin
    • Journal of Chest Surgery
    • /
    • v.57 no.3
    • /
    • pp.312-314
    • /
    • 2024
  • A 3-year-old boy with Glenn physiology exhibited refractory heart failure with reduced ejection fraction. To improve the patient's oxygen saturation, he underwent ventricular assist device (VAD) implantation with concomitant Fontan completion. The extracardiac conduit Fontan operation was performed with a 4-mm fenestration. For VAD implantation, Berlin Heart cannulas were positioned at the left ventricular apex and the neo-aorta. Following weaning from cardiopulmonary bypass, a temporary continuous-flow VAD, equipped with an oxygenator, was utilized for support. After a stabilization period of 1 week, the continuous-flow VAD was replaced with a durable pulsatile-flow device. Following 3 months of support, the patient underwent transplantation without complications. The completion of the Fontan procedure at the time of VAD implantation, along with the use of a temporary continuous-flow device with an oxygenator, may aid in stabilizing postoperative hemodynamics. This approach could contribute to a safe transition to a durable pulsatile VAD in patients with Glenn physiology.

Prognostic and Safety Implications of Renin-Angiotensin-Aldosterone System Inhibitors in Hypertrophic Cardiomyopathy: A Real-World Observation Over 2,000 Patients

  • Chan Soon Park;Tae-Min Rhee;Hyun Jung Lee;Yeonyee E. Yoon;Jun-Bean Park;Seung-Pyo Lee;Yong-Jin Kim;Goo-Yeong Cho;In-Chang Hwang;Hyung-Kwan Kim
    • Korean Circulation Journal
    • /
    • v.53 no.9
    • /
    • pp.606-618
    • /
    • 2023
  • Background and Objectives: The prognostic or safety implication of renin-angiotensin-aldosterone system inhibitors (RASi) in hypertrophic cardiomyopathy (HCM) are not well established, mainly due to concerns regarding left ventricular outflow tract (LVOT) obstruction aggravation. We investigated the implications of RASi in a sizable number of HCM patients. Methods: We enrolled 2,104 consecutive patients diagnosed with HCM in 2 tertiary university hospitals and followed up for five years. RASi use was defined as the administration of RASi after diagnostic confirmation of HCM. The primary and secondary outcomes were all-cause mortality and hospitalization for heart failure (HHF). Results: RASi were prescribed to 762 patients (36.2%). During a median follow-up of 48.1 months, 112 patients (5.3%) died, and 94 patients (4.5%) experienced HHF. Patients using RASi had less favorable baseline characteristics than those not using RASi, such as older age, more frequent history of comorbidities, and lower ejection fraction. Nonetheless, there was no difference in clinical outcomes between patients with and without RASi use (log-rank p=0.368 for all-cause mortality and log-rank p=0.443 for HHF). In multivariable analysis, patients taking RASi showed a comparable risk of all-cause mortality (hazard ratio [HR], 0.70, 95% confidence interval [CI], 0.43-1.14, p=0.150) and HHF (HR, 1.03, 95% CI, 0.63-1.70, p=0.900). In the subgroup analysis, there was no significant interaction of RASi use between subgroups stratified by LVOT obstruction, left ventricular (LV) ejection fraction, or maximal LV wall thickness. Conclusions: RASi use was not associated with worse clinical outcomes. It might be safely administered in patients with HCM if clinically indicated.

Analysis of Left Ventricular Functional Parameters in Normal Korean Subjects by ECG Gated Blood Pool Scan (정상 한국인에서 게이트혈액풀스캔을 이용한 좌심실 심기능지표들의 분석)

  • Kang, Jae-Hwang;Park, Une-Sook;Kang, Byeong-Sun;Lim, Hyeon-Ok;Choi, Dong-Soo;Suh, Bong-Kwan;Chung, Soon-Il;Lee, Keun-Woo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.1
    • /
    • pp.52-61
    • /
    • 1994
  • Background : The demand for refinement in noninvasive and quantitative assessment of left ventricular (LV) function is increasing. Purpose : To assess normal values of left ventricular functional parameters during both systole and diastole by scintigraphic method using computerized triple-head gamma camera and to evaluate correlations between these parameters. Methods : ECG gated blood pool scan with $^{99m}Tc$-Human serum albumin was performed in 94 normal Korean subjects. Ejection fraction (EF), systolic parameters [peak emptying rate (PER), average emptying rate (AER), time to peak emptying rate (TPER)], and diastolic parameters [peak filling rate (PFR), average filling rate (AFR), time to peak filling rate (TPFR)] were obtained by analysis of LV time-activity curve, the correlation of these parameters to the age and sex, and the correlation between these parameters were evaluated. Results : 1) Mean value of ejection fraction in study subjects was $59.6{\pm}5.25%$ and showed no significant correlation to age (r=-0.08) and sex but showed most pronounced correlation to PFR (r=0.46, p<0.001), PER (r=0.41, p<0.001), AFR (r=0.34, p<0.001) and AER (r=0.28, p<0.01). 2) Mean values of systolic parameters were as follows: $PER=3.22{\pm}0.50$ end-diastolic volume/sec, $AER=2.22{\pm}0.45$ end-diastolic volume/sec, $TPER=103.5{\pm}29.30$ msec. They showed no significant correlation to age and sex. 3) Mean values of diastolic parameters were as follows: $PFR=2.71{\pm}0.51$ end-diastolic volume/sec, $AFR=1.83{\pm}0.44$ end-diastolic volume/sec, $TPFR=132.1{\pm}33.45$ msec. They showed strong correlation to age (r=0.70, -0.64, 0.37, p<0.001). Conclusions : Left ventricular functional parameters in normal Korean subjects were obtained reliably by computerized scintigraphic method and may be applied to the evaluation of cardiac function in diseased patients.

  • PDF

Takotsubo Cardiomyopathy Associated with Guillain-Barré Syndrome (길랑-바레 증후군에서 발생한 Takotsubo 심근병)

  • Kang, Chul-Hoo;Oh, Jung Hwan;Song, Sook Keun;Kang, Sa-Yoon
    • Annals of Clinical Neurophysiology
    • /
    • v.17 no.2
    • /
    • pp.73-75
    • /
    • 2015
  • A 69-year-old woman presented with a progressive limb weakness. Both clinical and neurophysiological findings were consistent with diagnosis of Guillain-$Barr{\acute{e}}$ syndrome (GBS). Two days after admission, the patient suffered from an acute coronary syndrome without stenosis at coronary arteriography. Echocardiography revealed left ventricular inferior wall and apical akinesia and decreased ejection fraction. A diagnosis of Takotsubo cardiomyopathy was then made. Left ventricular dysfunction and electrocardiography normalized within one month. Takotsubo cardiomyopathy can be developed as a complication of GBS.