• Title/Summary/Keyword: Ventricular ejection fraction

검색결과 205건 처리시간 0.028초

방사성동위원소 심조영술상 심전도게이트 일회통과법을 이용한 우심실 박출계수 (Right Ventricular Ejection Fraction using ECG-Gated First Pass Cardioangiography)

  • 문영희;이해규;이성용;박석민;정수교;임정익;박용휘;신경섭;김영균;권순석
    • 대한핵의학회지
    • /
    • 제27권1호
    • /
    • pp.135-139
    • /
    • 1993
  • Radionuclide cardioangiography has been widely applied and has played major roles in non-invasive assessment of cardiac function. Three techniques, first-pass, gated first and gated equilibrium methods, have commonly been used to evaluate right ventricular ejection fraction which usually abnormal in the patients with cardiopulmonary disease. It has been known that the gated first pass method is the most accurate method among the three techniques in assessment of right ventricular ejection fraction. The radionuclide right ventricular ejection fraction values were determined in 13 normal subjects and in 15 patients with chronic obstructive pulmonary disease by the gated first pass method and compared with those of the first pass method because there ha,j been no published data of right ventricular ejection fraction by the gated first pass method in Korea. The values of right ventricular ejection fraction by the gated first pass method were compared with the detas from the pulmonary function test performed in the patients with chronic obstructive pulmomary disease. The results were as follows: 1) The values of right ventricular ejection fraction by the gated first pass method were $50.1{\pm}6.1%$ in normal subjects and $38.5{\pm}8.5$ in the patients with chronic obstructive pulmonary disease. There was statistically significant difference between the right ventricular ejection fraction of each of the two groups (p < 0.05). 2) The right ventricular ejection fraction by the gated first pass method was not linearly correlated with $FEV_1$, VC, DLCO, and FVC as well as $P_aO_2$ and $P_aCO_2$ of the patients with chronic obstructive pulmonary disease. We concluded that right ventricular ejection fraction by the gated first pass method using radionuclide cardioangiography may be useful in clinical assessment of the right ventricular function.

  • PDF

방사성 동위원소를 이용한 개심술 전후의 심실기능 변화에 관한 연구: ECG gated blood pool scan을 이용한 ejection fraction 검사 (Clinical Study of Ventricular Function Following Open Heart Surgery by Radionuclide Angiocardiogram - left ventricular ejection fraction by ECG gated blood pool scan -)

  • 이정철;김규태
    • Journal of Chest Surgery
    • /
    • 제19권1호
    • /
    • pp.25-34
    • /
    • 1986
  • Recently, radionuclide angiocardiogram is one of the most common procedure for assessment of ventricular performance due to its distinctive advantages such as safety, accuracy, and ease of repeated studies. Also, measurement and comparison between pre and postoperative left ventricular ejection fraction [LVEF] are meaningful for assessing the severity of myocardial damage which occurred during open heart surgery and the status of myocardial recovery. We obtained pre and post operative LVEF using radionuclide angiocardiogram on 30 patients composed of atrial septal defect, ventricular septal defect, cyanotic congenital heart disease, and valvular heart disease who undergone the open heart surgery from March to august 1984. The study revealed that ventricular septal defect and mitral valvular heart disease showed 8.1% and 6.2% decreases of postoperative LVEF, respectively. But, there are little increases of postoperative LVEF in the atrial septal defect and cyanotic congenital heart disease. In ventricular septal defect, each group of Qp/Qs over 2.0 and systolic pulmonary artery pressure over 50mmHg showed significant 17% and 14.7% decreases of postoperative LVEF, respectively. Considering the duration of the aortic cross clamping times and closing methods of VSD, each group of duration over 30 min. and of patch closure showed 13.9% and 14.2% decreases of LVEF between pre and postoperative status respectively which was significant finding statistically.

  • PDF

디지탈 혈관 조영상에서의 좌심실 경계 자동검출을 이용한 심박출 계수의 측정 (A Measurement of Heart Ejection Fraction using Automatic Detection of Left Ventricular Boundary in Digital Angiocardiogram)

  • 구본호;이태수
    • 대한의용생체공학회:의공학회지
    • /
    • 제8권2호
    • /
    • pp.177-188
    • /
    • 1987
  • Detection of left ventricular boundary for the functional analysis of LV(left ventricle) is obtained using automatic boundary detection algorithm based on dynamic program ming method. This scheme reduces the edge searching time and ensures connective edge detection, since it does not require general edge operator, edge thresholding and linking process of other edge detection methods. The left ventricular diastolic volume and systolic volume were computed after this automatic boundary detection, and these volume data were applied to analyze LV ejection fraction.

  • PDF

방사성핵종 심혈관조영술의 기능적영상화에 대한 고찰 (Comparison of functional Images obtained by radionuclide angiocardiography and gated blood pool scan)

  • 범희승;김지열
    • 대한핵의학회지
    • /
    • 제25권2호
    • /
    • pp.186-191
    • /
    • 1991
  • Radionuclide cardiac studies lend themselves exceptionally well to functional imaging. This is especially true for gated blood pool scan (GBP). Making functional images is also possible in radionuclide angiocardiography (RNAC). In this study we tried to validate the functional images obtained from RNAC by comparing it with GBP. Twenty three patients (16 patients with coronary artery diseases, 5 with hypertensive heart diseases, and 2 with nonspecific chest pains) underwent simultaneous RNAC and GBP at the same position (LAO $45^{\circ}$). From both studies, global ejection fraction, regional ejection fraction, phase image, amplitude image, stroke image, paradox image, maximum ejection and maximum filling rates were obtained. Global ejection fraction are almost same in both studies. Regional ejection fractions of apex and inferior portion of left ventricle calculated from RNAC are well correlated with those of GBP. Phase and paradox image, maximum ejection and maximum filling rates were obtained. Global ejection fraction are almost same in both studies. Regional ejection fractions of apex and inferior portion of left ventricle calculated from RNAC are well correlated with those of GBP. Phase and paradox images of RNAC are very similar to those of GBP. However, amplitude and stroke images are different. Regional ejection fractions of the left ventricular base, maximum ejection and maximum filling rates obtained from RNAC are significantly different from those of GBP. In conclusion, albeit all of functional images of RNAC is not same as GBP, regional walt motions and global left ventricular function are expected to be successfully analyzed by phase and paradox image and ejection fraction.

  • PDF

방사선동위원소 심혈관촬영술을 이용한 우심실기능 측정에 관한 연구 -만성폐쇄성 폐질환에서의 우심실 Ejection Fraction- (Evaluation of Right Ventricular Function with Radionuclide Cardiac Angiography: Right Ventricular Ejection Fraction in Chronic Obstructive Lung Disease)

  • 손인;신성해;정준기;이명철;조보연;이영우;한용철;고창순
    • 대한핵의학회지
    • /
    • 제16권1호
    • /
    • pp.1-6
    • /
    • 1982
  • To evaluate the usefulness of radionuclide cardiac angiography in the assessment of right ventricular function, we measured right ventricular ejection fraction (RVEF) using single pass method. In 12 normal persons, RVEF averaged $52.7{\pm}5.9%(mean{\pm}S.D.)$. In 25 patients with chronic obstructive lung disease, RVEF was $37.2{\pm}10.6%$ and significantly lower than that of normal persons (p<0.01). All 10 patients with right ventricular failure had abnormal RVEF, which was significantly lower than that of 14 patients without right ventricular failure ($27.6{\pm}5.7%,\;43.9{\pm}8.5%$, respectively. p<0.01). It concluded thal RVEF measured by single pass radionuclide cardiac angiography was a useful, noninvasive method to assess right ventricular function.

  • PDF

Effect of Korea Red Ginseng on the Symptoms and Hemodynamics in Healthy Elders

  • Jin En-Yuan;Li Ya-Jun;Yang Lian-Xing;Jin Ming;Wei Yu-Lin;Nam Ki Yeul
    • 고려인삼학회:학술대회논문집
    • /
    • 고려인삼학회 2002년도 학술대회지
    • /
    • pp.27-34
    • /
    • 2002
  • Clinical study on hemodynamics of healthy elders before and after tread mill. Using doubleblind, placebo-controlled study design. Seventy-five 50-70 years old volunteers without organic disease were divided into two groups, Ginseng group and control group. Each subject was received 3 g Korea Red Ginseng (KRG) capsules or placebo per day for 4 weeks. Before and after administration 4 weeks, the symptoms were asked and hemodynamics parameter such as pump function, systolic function, preload and afterload were recorded before and after tread mill 1,5, 10 minutes by the method of thoracic impedance cardiograph. The result showed that Ginseng could improve quality of life, had obvious effect of increasing PEP (pre-ejection period), PEP/LVET (pre-ejection period/left ventricular ejection period), PCWP (wedged pressure pulmonary capillary). The change rate of HR (heart rate), SV (stroke volume) in KRG group were much lowered, while EF (ejection fraction), LVET (left ventricular ejection period), LVEDP (left ventricular end diastolic pressure) was recovered much quickly. The circulation showed Ginseng could improve the quality of life though its promoting circulation function which are increasing both the systolic function and the preload.

  • PDF

심전도 게이트 심근관류 Tl-201 SPECT로 측정된 좌심실 기능 및 좌심실 용적의 정확성 (Accuracy of Ventricular Volume and Ejection Fraction Measured by Gated Tl-201 Perfusion Single Photon Emission Tomography)

  • 배문선;문대혁
    • 대한핵의학회지
    • /
    • 제39권2호
    • /
    • pp.94-99
    • /
    • 2005
  • Electrocardiogram-gated single photon omission computed tomography (SPECT) provides valuable information in the assessment of both myocardial perfusion and ventricular function. Tl-201 is a suboptimal isotope for gating. Tl-201 images are more blurred compared with Tc-99m tracers due to the increased amount of scattered photons and use of a smooth filter. The average myocardial count densities are approximately one-half those of conventional technetium tracers. However, Tl-201 is still widely used because of its well-established utility for assessing myocardial perfusion, viability and risk stratification. Gated SPECT with Tl-201 enables us to assess both post-stress and rest left ventricular volume and function. Previous studies with gated Tl-201 SPECT measurements of ejection fraction (EF), end-diastolic volume (EDV), end-systolic volume (ESV) have shown high correlation with first-pass radionuclide angiography, gated blood pool scan, Tc-99m-MIBI gated SPECT, contrast ventriculography, echocardiography, and 3-dimensional magnetic resonance imaging. However, problems related to these studies include few agreement data of EDV and ESV, use of a reference method that is likely to have the same systemic errors (gated Tc-99m-MIBI SPECT), and other technical factors related to the count density of gated SPECT. With optimization of gated imaging protocols and more validation studies, gated Tl-201 SPECT would be an accurate method to provide perfusion and function information in patients with coronary artery disease.

역동적 삼차원 재구성기로 측정한 In Vivo 상태의 좌심실의 Emax 와 박출계수 (In Vivo Estimation of Emax and Ejection Fraction Using Dynamic Spatial Reconstructor)

  • 김광호
    • Journal of Chest Surgery
    • /
    • 제21권2호
    • /
    • pp.223-230
    • /
    • 1988
  • Emax, end-systolic pressure-volume relationship, has been established as a new concept which can be representative of ventricular contractility itself since 1970s. Comparing to ejection fraction[EF], Emax is independent of preload and afterload. However Emax has not been proved precisely in non-thoracotomized condition because current methods have limitation in measuring ventricular chamber volume accurately in in viva state. The Dynamic Spatial Reconstructor[DSR], high speed computerized tomography, can measure ventricular chamber volume accurately throughout cardiac cycle in non-thoracotomized state. So Emax and EF of the left ventricle was tried to measure precisely in in vivo condition with DSR. Emax was compared to EF to estimate its ability to evaluate ventricular contractility. 5 mongrel dogs, weighing 15-16kg, were used for measuring Emax and EF of the left ventricle in 3 or 4 different loading conditions using DSR. Emax value in 5 dogs was from 2.62 to 10.49. Each dog has one Emax value regardless of loading conditions. However EF in 5 dogs varies depending on loading conditions. The conclusions are that Emax is useful in in viva state and EF varies depending on loading conditions. So Emax should be tried to use in clinical situation rather than EF because it is always representative of contractility itself regardless loading conditions in in viva state.

  • PDF

선천성 대동맥 협착증의 술전 및 술후 단기간의 수축말기 좌심실 내벽 스트레스의 변화 (Alterations in Left ventricular End-systolic Wall Stress During Short-term Follow-up After Correction of Isolated Congenital Aortic Stenosis)

  • 김시호
    • Journal of Chest Surgery
    • /
    • 제33권10호
    • /
    • pp.777-784
    • /
    • 2000
  • Congenital aortic stenosis in children is characterized by "excessive" left ventricular hypertrophy with reduced left ventricular systolic wall stress that allows for supernormal ejection performance. We hypothesized that left ventricular wall stress was decreased immediately after surgical correction of pure congenital aortic stenosis. Also measuring postoperative left ventricular wall stress was a useful noninvasive measurement that allowed direct assessment for oxygen consumption of myocardium than measuring the peak systolic pressure gradient between ascending aorta and left ventricle for the assessment of surgical results. Material and Method: Between September 1993 and August 1999, 8 patients with isolated congenital aortic stenosis who underwent surgical correction at Yonsei cardiovascular center were evaluated. There were 6 male and 2 female patients ranging in age from 2 to 11 years(mean age, 10 years). Combined Hemodynamic-Ultrasonic method was used for studying left ventricular wall stress. We compared the wall stress peak systolic pressure gradient and ejection fraction preoperatively and postoperatively. Result: After surgical correction peak aortic gradient fell from 58.4${\pm}$17.6, to 23.7${\pm}$17.7 mmHg(p=0.018) and left ventricular ejection fraction decreased but it is not statistically significant. In the consideration of some factors that influence left ventricular end-systolic wall stress excluding one patient who underwent reoperation for restenosis of left ventricular outflow tract left ventricular end-systolic pressure and left ventricular end-systolic dimension were fell from 170.6${\pm}$24.3 to 143.7${\pm}$27.1 mmHg and from 1.78${\pm}$0.4 to 1.76${\pm}$0.4 cm respectively and left ventricular posterior wall thickness was increased from 1.10${\pm}$0.2, to 1.27${\pm}$0.3cm but it was not statistically singificant whereas left ventricular end-systolic wall stress fell from 79.2${\pm}$24.9 to 57.1${\pm}$27.6 kdynes/cm2(p=0.018) in 7 patients. For one patient who underwent reoperation peak aortic gradient fell from 83.0 to 59.7 mmHg whereas left ventricular end-systolic wall stress increased from 67.2 to 97.0 kdynes/cm2 The intervals did not change significnatly. Conclusion ; We believe that probably some factors that are related to left ventricular geometry influenced the decreased left ventricular wall stress immediately after surgical correction of isolated congenital aortic stenosis. Left ventricular wall stress is a noninvasive measurement and can allow for more direct assesment than measuring peak aortic gradient particularly in consideration of the stress and oxygen consumption of the myocardium therefore we can conclude it is a useful measurement for postoperative assessment of congenital aortic stenosis.

  • PDF