• Title/Summary/Keyword: Ventilatory threshold

Search Result 4, Processing Time 0.019 seconds

Measurement of Ventilatory Threshold in the Patients with Chronic Airway Obstruction (만성기도폐쇄를 보이는 환자에서 환기성역치 측정)

  • Lee, Kye-Young;Jee, Young-Koo;Kim, Keun-Yeol
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.2
    • /
    • pp.309-320
    • /
    • 1997
  • Background : There are many suggested methods for the indirect determination of anaerobic threshold(AT) using the changes of ventilatory parameters in response to ventilatory load accompanying the increase of blood lactic acid level during exercise and the threshold derived from them is called ventilatory threshold(VT). They include ventilatory equivalent method(VEM), End-tidal $PO_2$ method($PETO_2$). V-slope method(VSM), and respiratory quotient method(RQ). But in the patients with chronic airway obstruction(CAO), the AT determined by ventilatory methods may not reflect true AT because the patients with CAO show inadequate ventilatory response to the increase of blood lactic acid level during excercise. Methods : For the investigation of detection rate and reliability of above four VT determination methods in the patients with CAO, we performed the symptom-limited and maximal incremental exercise test in 17 patients with CAO and 12 normal controls. The incremental workload was 10 W /min in CAO group and 25 W/min in control group. The reliability of VT in each group was investigated by the calculation of Spearman correlation coefficient. Results : The detection rates of VT were 100% by RQ, 91.7% by both VEM and $POETO_2$, and 83.3% by VSM in normal control group, while 94.1% by RQ, 64.7% by VEM and $PETO_2$, and 83.3% by VSM in CAO group. Good correlations were noted among VEM, $POETO_2$, and VSM except RQ in normal control group. But there was no significant correlation except between VEM and $PETO_2$ in CAO group. Conclusions : RQ is very sensitive but crude and VEM is near similar to $PETO_2$. The clinical usefulness of VT determined by ventilatory method might be limited in patients with severe CAO.

  • PDF

Physical Performance in Young Women with Depleted Iron Stoles (젊은 여성의 철분저장 고갈상태와 운동수행능력)

  • 정영진;정명일;정종귀
    • Journal of Nutrition and Health
    • /
    • v.35 no.2
    • /
    • pp.223-228
    • /
    • 2002
  • The purpose of this study was to investigate the relationship between iron deficiency without anemia and physical performance in healthy women aged 20-21 yrs. Ten subjects with normal iron stores (serum ferritin $\geq$ 12$\mu\textrm{g}$/L: iron-sufficient group) and 11 subjects with iron depletion without anemia (serum ferritin < 12 $\mu\textrm{g}$/L and serum hemoglobin > 120 g/L: iron-depleted group) were chosen from a group of 50 women and were given physical-performance tests, including determinations of maximum oxygen consumption (VO$_2$ max) and ventilatory threshold. Iron status assessment included determination of hemoglobin, hematocrit, seam ferritin, total iron-binding rapacity, serum iron and transferrin saturation values. Dietary iron intake was assessed based on seven-day food intake records written by the subjects. Physical activity level was estimated by frequency questionnaires and two-week physical activity records were compiled daily by the subjects. Blood ferritin concentration was significantly lower in the iron-depleted group than in the iron-sufficient group (p < 0.05). However, other variables showing iron status was not different between the groups. There were no significant differences in body size, body composition and physical activity levels between the groups. Daily dietary iron, total protein and animal protein intakes of the iron-sufficient group were significantly higher than those of the iron depleted group. However, no differences were found in the amount of dietary vitamin C and fiber between the groups. The values for VO$_2$max and VO$_2$max corrected with weight or fat-free mass were not different between the groups. However, the ventilatory threshold was significantly higher in the iron sufficient group than in the iron-depleted group. The lower ventilatory threshold in the iron-depleted group suggests that iron depletion without anemia could diminish aerobic physical performance in young women. In addition, a significant correlation of physical performance to serum fferritin level was shown only in the iron depleted group.

Comparison of the Anaerobic Threshold Level Between Subjects With and Without Non-Specific Chronic Low Back Pain (비특이성 만성요통 유무에 따른 무산소성 역치수준 비교)

  • Seong, Jun-Hyuk;Kwon, Oh-Yun;Yi, Chung-Hwi;Cynn, Heon-Seock;Cho, Young-Ki
    • Physical Therapy Korea
    • /
    • v.18 no.1
    • /
    • pp.74-82
    • /
    • 2011
  • The purpose of this study was to compare the anaerobic threshold (AT) between subjects with and without non-specific chronic low back pain (NCLBP). The patient group included 15 women with NCLBP. The normal group included 15 women without NCLBP who were age-, height-, weight-, and activity level-matched. The subjects performed a Balke treadmill protocol which was symptom-limited progressive loading test. Their heart rate (HR), ventilatory gas and metabolic equivalents (METs) were measured using the automatic breath gas analyzing system. After the test, each subjects' ratings of perceived exertion (RPE) were evaluated. The visual analog scale (VAS) was assessed pre- and post-test. The independent t-test and Wilcoxon's signed-rank test were used for analysis of the data. Time, HR, the volume of oxygen consumption ($VO_2$), relative $VO_2$, and METs at the AT level of the patient group were significantly lower than those of the healthy group (p<.05). However, there were no significant differences in RPE, VAS, and breathing frequency at the AT level (p>.05). The findings of this study indicate that patients with NCLBP had a lower aerobic fitness than healthy subjects. Thus, implementation of rehabilitation program to increase aerobic fitness may be considered in patietns with NCLBP, and further studies are required to determine the etiological factors of decreased aerobic fitness.

The Effects of Smoking on Aerobic Physical Fitness Factors among Physical Education Major Male University Students Participating in Regular Exercise (체육전공 남자 대학생의 흡연여부가 유산소 체력요인에 미치는 영향)

  • Sung, Dong-Junn;Park, Hye-Mi;Cha, Kwang-Suk
    • Korean Journal of Health Education and Promotion
    • /
    • v.28 no.5
    • /
    • pp.97-104
    • /
    • 2011
  • Objectives: The purpose of this study was to examine the effect of smoking on aerobic physical fitness among physical education major male university students participating in regular exercise. Methods: A group of 42 healthy male students majoring physical education were divided into two groups: non-smokers (n=$26, 20.61{\pm}2.78 $yrs) and smokers (n=16, $21.25{\pm}2.29 $ yrs). Graded exercise testing for maximal oxygen consumption ($VO_2max$) was measured by Bruce protocol. Results: $VO_2max$ was not different between non-smokers and smokers, however, exercise duration time in non-smokers was more longer than smokers'. In non-smokers, ventilatory threshold (VT) time was delayed longer than smokers (p<0.01). %VT/VEmax was significantly different between non-smokers and smokers (p<0.01). Resting heart rate (p<0.01) and recovery heart rate at 80 seconds (p<0.01) in non-smokers were significantly lower than those of smokers. The decrease in heart rate recovery in non smokers was greater than in smokers at 40(p<0.05), 60(p<0.05) and 80(p<0.01) seconds. Conclusions: These results suggest that smoking has negative effects on aerobic fitness of male university students in physical education major.