내과계중환자실에서 인공호흡기관련 폐렴 번들 적용의 효과 (Impact of the Ventilator-associated Pneumonia Bundle in a Medical Intensive Care Unit)

  • 유송이;정재심;최상호;김미나
    • Journal of Korean Biological Nursing Science
    • /
    • 제20권4호
    • /
    • pp.205-213
    • /
    • 2018
  • Purpose: The purpose of this study was to confirm the compliance of the application of a ventilator-associated pneumonia bundle and understand its effects on the decrease in the incidence of ventilator-associated pneumonia. Methods: This was a retrospective observational study with history control group design. Subjects were selected from January to June 2014, prior to the intervention using the ventilator-associated pneumonia bundle. Subjects were also selected from October 2014 to March 2015, 3 months after the intervention. The number of subjects was 112 before the intervention, and 107 after the intervention. Results: The number of nurses who followed the bundles increased from 8 out of 29 (27.6%) before the intervention to 19 out of 29 (65.5%) after the intervention (odd ratio= 4.99, confidence interval= 1.63-15.25, p= .004). There were 3 cases of ventilator-associated pneumonia before the intervention and 1 case after the intervention. The ventilator days were 2,143 days before the intervention and 2,232 days after the intervention. The ventilator-associated pneumonia rate of the 1,000 ventilator days was 1.40 before the intervention and decreased to 0.45 after the intervention. Conclusion: This study is meaningful, as there has been little research conducted regarding the application of the ventilator-associated pneumonia bundle in South Korea.

회로 교환주기에 따른 인공호흡기 관련 폐렴발생률 차이 (Ventilator-associated Pneumonia with Circuit Changes Every 7 Days versus Every 14 Days)

  • 최정실;연정화
    • 대한간호학회지
    • /
    • 제40권6호
    • /
    • pp.799-807
    • /
    • 2010
  • Purpose: To determine whether the practice of not routinely changing ventilator circuits in patients who require prolonged mechanical ventilation is associated with ventilator-associated pneumonia (VAP). Methods: Patients were divided into two groups, ventilator circuits were routinely changed every 7 days for the control group (39) and every 14 days for the experimental group (40) over a period of 1 yr (April 1, 2009-March 31, 2010). Pediatric patients (age 17 yr or less) were not included. VAP was diagnosed by the criteria of the Centers of Disease Control and Prevention (CDC). Incidence of VAP and characteristics of infection were evaluated. Results: In the experimental group, 2 episodes of pneumonia were observed in 40 patients and 1,322 ventilator days. The rate of VAP was 1.5 per 1,000 ventilator days. There was 1 episode of pneumonia in 39 patients and 481 ventilator days for the control group. The rate of VAP was 2.1 per 1,000 ventilator days. The difference between both groups was not significant (p=.695). Conclusion: Extending ventilator circuit change interval from 7 days to 14 days does not increase the risk for VAP.

인공호흡기 회로 교환주기가 인공호흡기 관련 폐렴에 미치는 영향에 관한 메타 분석 (A Meta-Analysis of the Ventilator Circuit Change Period on Ventilator-Associated Pneumonia)

  • 송주현;김경희
    • 임상간호연구
    • /
    • 제16권3호
    • /
    • pp.111-121
    • /
    • 2010
  • Purpose: This meta-analysis was aimed to investigate the evidence of proper period of the ventilator circuit change using existing research. Methods: For this study, 14 published studies between 1995 and 2010 were tested by Macaskill, Funnel Plot, the Odds Ratio of DerSimonian and Laird, Fisher and Liptak analysis. Results: There were no publication bias found in the subjects. The results of the meta-analysis demonstrated no statistically significant differences were observed in neither the Odds Ratio (OR=1.18, 95% CI=0.94-1.47) of the frequency of ventilator-associated pneumonia and the mortality based on the period of the ventilator circuit change (Fisher p=.332, Liptak p=.498), nor the ventilation duration of ventilator (Fisher p=.843, Liptak p=.506), and the hospital length of stay (Fisher p=.254, Liptak p=.480). Conclusion: In order to present more concrete guidelines on the period of the ventilator circuit change, further research is warranted to thoroughly control confounding variables which related to the periods of the ventilator circuit change.

중환자의 인공호흡기 관련 폐렴 예방을 위한 클로르헥시딘의 효과 : 메타 분석 (The Effects of Oral Care with Chlorhexidine for Ill Patients to Prevent Ventilator-associated Pneumonia : A Meta-Analysis)

  • 이하늬;박정숙
    • 한국콘텐츠학회논문지
    • /
    • 제17권8호
    • /
    • pp.241-249
    • /
    • 2017
  • 본 연구는 인공호흡기 적용 환자들의 구강간호에 있어 클로르헥시딘의 적용에 대한 효과성을 분석하고, 이를 토대로 임상에서 실질적으로 구강간호 시행에 있어 명확한 근거를 제시 하고자 시도 되었다. 주요 검색어는 Ventilator associated pneumonia AND (Oral care OR Dental care OR Chlorhexidine*)으로 검색원으로는 국내 RISS, Koreamed, KISS와 국외 MEDLINE, Cochrane Central, CINAHL, Pub Med를 활용하여 2017년 5월까지의 문헌을 대상으로 검색하였다. 총 19편의 연구가 최종 선정되었고, Revman 5.3 프로그램으로 분석 하였으며, RoB (The Cochrane's Risk of Bias)도구를 이용해 문헌의 질을 평가하였다. 연구결과 중환자의 인공호흡기 관련 폐렴 예방에 있어 클로르헥시딘의 적용은 통계적으로 유의한 효과가 있었음이 나타났다.

중증 외상환자의 인공호흡기 관련 폐렴 영향 요인 분석 (Analysis of Influence Factors on Ventilator-Associated Pneumonia in Severe Trauma Patients)

  • 박빛나;김은주
    • 가정∙방문간호학회지
    • /
    • 제25권3호
    • /
    • pp.224-231
    • /
    • 2018
  • Purpose: This study was to analyze the factors affecting ventilator-associated pneumonia with severe trauma patients. Methods: This study conducted from May 1, 2018 to May 31, 2018 based on the medical records of the intensive care unit of a university hospital from May 1, 2017 to April 30, 2018 in Gangwon province. The inclusion criteria were 1) Trauma intensive care unit patient, 2) older than 19 years 3) without pneumonia at the time of admission. The collected data were analyzed using descriptive, correlation analysis, ANOVA, t-tests, $x^2$-tests and regression. Results: The severe trauma patients had a total of 2,877 days receiving ventilator, and nine VAP cases. The overall infection rate was 4.0%, and the VAP incidence rate was 3.13 per 1000 ventilator days. VAP in severe trauma patient affected ICU stay(OR=1.03), mechanical ventilator applied day(OR=1.04). Conclusion: Therefore, the development of an individualized VAP prevention bundle and nursing intervention for patients with trauma will be needed and further studies. In addition, there were no findings regarding the relationship between VAP occurrence and the severity of multiple traumatic injuries, so further studies of these factors should be performed.

인공호흡기 튜브교환주기에 따른 인공호흡기 관련 폐렴발생률 (The Incidence Rate of Ventilator Associated Pneumonia in Relation to the Exchange of Circuit Cycle)

  • 김남초;김양리
    • 성인간호학회지
    • /
    • 제15권3호
    • /
    • pp.463-471
    • /
    • 2003
  • Purpose: This study was aimed at providing scientific evidence for minimizing ventilator-associated pneumonia(VAP) by identifying appropriate timing of exchange of circuit for mechanical ventilator that is well suitable for the medical environment of intensive care units of hospitals in Korea. Method: This was a quasi-experimental study with a convenience sample of 19 adult subjects aged over 18 years who were admitted to the NS ICU of C university hospital, and placed on mechanical ventilator. The subjects were placed in two groups, compared on the incidence rate of VAP after they received exchange of circuit either at 1-week interval (N =10) or 2-week interval (N = 9). Result: 1) When considering 1000 days as the standard unit of analysis for incidence, the incidence rate of VAP was 7.19 cases at the 1-week cycle exchange group and 15.23 at the 2-week cycle exchange group, showing no statistically significant difference between the two groups. 2) There were a total of 3 types of bacteria isolated from the patients with VAP, including 2 cases with P. aeruginosa, 1 case with Streptococcus group F and A. baumannii. Conclusion: With thorough hand washing and strict management of tracheal tube of mechanical ventilator as well as use of tracheal intubation techniques, exchange cycle of circuit of mechanical ventilator by nurses may be changed from 1-week to 2-week interval.

  • PDF

기관 흡인술 유형에 따른 인공호흡기 적용 환자의 기관 내 균집락화와 폐렴 발생률 (Endotracheal Colonization and Ventilator-associated Pneumonia in Mechanically Ventilated Patients according to Type of Endotracheal Suction System)

  • 차경숙;박호란
    • 대한간호학회지
    • /
    • 제41권2호
    • /
    • pp.175-181
    • /
    • 2011
  • Purpose: This study was conducted to identify endotracheal colonization and the incidence of ventilator-associated pneumonia related to the type of endotracheal suction system. Methods: The participants in this study were ICU patients hospitalized between October 2009 to March 2010 who used ventilators for over 48 hr with closed (CSS, n=30) or open (OSS, n=32) suction systems. To standardize the pre-intervention suction system, a suctioning protocol was taught to the ICU nurses. Collected data were analyzed using ${\chi}^2$-test, Fisher's exact test, Wilcoxon rank sums test, Wilcoxon test, Log-rank test and Poisson regression. Results: Endotracheal colonization was higher in OSS than CSS from day 1 to day 8 while using a ventilator and there was a significant difference between the two groups. The CSS reached 50% of endotracheal colonization by the 4th day, whereas for the OSS, it was the 2nd day (p=.04). The incidence of ventilator-associated pneumonia showed no significant difference. Conclusion: For patients with a high risk of pneumonia, CSS must be used to lower endotracheal colonization.

의료진의 가정용 인공호흡기 관련 지식 정도와 교육요구도 조사 (A Survey on Nurses' and Physicians' Knowledge and Educational Needs on Home Ventilator)

  • 조수현;고명균;정진희;원선영;이희옥;남지명;위미숙;이영희
    • 중환자간호학회지
    • /
    • 제5권1호
    • /
    • pp.56-66
    • /
    • 2012
  • Purpose: The purpose of this study was to investigate the knowledge and educational needs of nurses and physicians on home ventilator. Methods: The participants were 140 nurses and 47 physicians working at departments using home ventilators. The data were collected from January 30 to February 12, 2012 through a self-administered questionnaire with 32 items of the knowledge and educational needs on home ventilator. Results: The mean scores of nurses' and physicians' knowledge were 2.52 and 2.56 respectively. The mean scores of nurses' and physicians' educational needs were 3.16 and 3.06 respectively. Nurses' knowledge was associated with their experience using and receiving education about home ventilator and willingness to receive education about home ventilator education. Nurses' educational needs were associated with their present working department and experience using home ventilator. Nurses with high knowledge were more likely to have high educational needs. Physicians' knowledge and educational needs were not associated with any their general characteristics. Conclusion: Nurses' and physicians' knowledge of home ventilator were low and their educational needs on home ventilator were high. To provide high quality of care for home ventilators, it is necessary to provide nurses and physicians with education and to develop a more specific educational program for them.

  • PDF

Clinical implications of the newly defined concept of ventilator-associated events in trauma patients

  • Lee, Tae Yeon;Oh, Jeong Woo;Lee, Min Koo;Kim, Joong Suck;Sohn, Jeong Eun;Wi, Jeong Hwan
    • Journal of Trauma and Injury
    • /
    • 제35권2호
    • /
    • pp.76-83
    • /
    • 2022
  • Purpose: Ventilator-associated pneumonia is the most common nosocomial infection in patients with mechanical ventilation. In 2013, the new concept of ventilator-associated events (VAEs) replaced the traditional concept of ventilator-associated pneumonia. We analyzed risk factors for VAE occurrence and in-hospital mortality in trauma patients who received mechanical ventilatory support. Methods: In this retrospective review, the study population comprised patients admitted to the Jeju Regional Trauma Center from January 2020 to January 2021. Data on demographics, injury characteristics, and clinical findings were collected from medical records. The subjects were categorized into VAE and no-VAE groups according to the Centers for Disease Control and Prevention/National Healthcare Safety Network VAE criteria. We identified risk factors for VAE occurrence and in-hospital mortality. Results: Among 491 trauma patients admitted to the trauma center, 73 patients who received ventilator care were analyzed. Patients with a chest Abbreviated Injury Scale (AIS) score ≥3 had a 4.7-fold higher VAE rate (odds ratio [OR], 4.73; 95% confidence interval [CI], 1.46-17.9), and those with a glomerular filtration rate (GFR) <75 mL/min/1.73 m2 had 4.1-fold higher odds of VAE occurrence (OR, 4.15; 95% CI, 1.32-14.1) and a nearly 4.2-fold higher risk for in-hospital mortality (OR, 4.19; 95% CI, 1.30-14.3). The median VAE-free duration of patients with chest AIS ≥3 was significantly shorter than that of patients with chest AIS <3 (P=0.013). Conclusions: Trauma patients with chest AIS ≥3 or GFR <75 mL/min/1.73 m2 on admission should be intensively monitored to detect at-risk patients for VAEs and modify the care plan accordingly. VAEs should be closely monitored to identify infections early and to achieve desirable results. We should also actively consider modalities to shorten mechanical ventilation in patients with chest AIS ≥3 to reduce VAE occurrence.

Secondary Analysis on Ventilator-Associated Pneumonia and Pressure Injury

  • Hyun, Sookyung;Moffatt-Bruce, Susan;Newton, Cheryl;Kaewprag, Pacharmon
    • International Journal of Advanced Culture Technology
    • /
    • 제6권3호
    • /
    • pp.211-215
    • /
    • 2018
  • Ventilator-associated pneumonia (VAP) is a lung infection that develops in patients receiving mechanical ventilation. VAP contributes to about 50% of hospital-acquired pneumonia in ICU settings. One of the recommendation of the Institute of for Healthcare Improvement ventilator bundle is HOB elevation. HOB elevation affects shearing forces and makes higher risk for pressure injury development. Pressure injury (PI) is localized damage to the skin over a bony prominence. PI prevention guidelines recommend that HOB positioning should be lower to reduce risk for PI development which contradicts VAP prevention guidelines for the HOB between 30 and 45 degrees for ICU patients. This presents a care dilemma and tension. The purpose of this study was to perform a secondary data analysis using cumulative electronic health record data in order to determine the association of HOB elevation with VAP and PI in ICU patients. A secondary data analysis was conducted to determine whether HOB elevation is associated with VAP and PI. HOB elevation was not likely to be associated with VAP prevention whereas it was likely to be related to PI development. This is somewhat contrary to popular data and publications. Prospective cohort study is desired to inform us in an evidence-based fashion what actually is optimal HOB elevation for ventilated patients in ICU settings.