Impact of the Ventilator-associated Pneumonia Bundle in a Medical Intensive Care Unit (내과계중환자실에서 인공호흡기관련 폐렴 번들 적용의 효과)

  • Yoo, Song Yi;Jeong, Jae Sim;Choi, Sang Ho;Kim, Mi Na
    • Journal of Korean Biological Nursing Science
    • /
    • v.20 no.4
    • /
    • pp.205-213
    • /
    • 2018
  • Purpose: The purpose of this study was to confirm the compliance of the application of a ventilator-associated pneumonia bundle and understand its effects on the decrease in the incidence of ventilator-associated pneumonia. Methods: This was a retrospective observational study with history control group design. Subjects were selected from January to June 2014, prior to the intervention using the ventilator-associated pneumonia bundle. Subjects were also selected from October 2014 to March 2015, 3 months after the intervention. The number of subjects was 112 before the intervention, and 107 after the intervention. Results: The number of nurses who followed the bundles increased from 8 out of 29 (27.6%) before the intervention to 19 out of 29 (65.5%) after the intervention (odd ratio= 4.99, confidence interval= 1.63-15.25, p= .004). There were 3 cases of ventilator-associated pneumonia before the intervention and 1 case after the intervention. The ventilator days were 2,143 days before the intervention and 2,232 days after the intervention. The ventilator-associated pneumonia rate of the 1,000 ventilator days was 1.40 before the intervention and decreased to 0.45 after the intervention. Conclusion: This study is meaningful, as there has been little research conducted regarding the application of the ventilator-associated pneumonia bundle in South Korea.

Ventilator-associated Pneumonia with Circuit Changes Every 7 Days versus Every 14 Days (회로 교환주기에 따른 인공호흡기 관련 폐렴발생률 차이)

  • Choi, Jeong-Sil;Yeon, Jeong-Haw
    • Journal of Korean Academy of Nursing
    • /
    • v.40 no.6
    • /
    • pp.799-807
    • /
    • 2010
  • Purpose: To determine whether the practice of not routinely changing ventilator circuits in patients who require prolonged mechanical ventilation is associated with ventilator-associated pneumonia (VAP). Methods: Patients were divided into two groups, ventilator circuits were routinely changed every 7 days for the control group (39) and every 14 days for the experimental group (40) over a period of 1 yr (April 1, 2009-March 31, 2010). Pediatric patients (age 17 yr or less) were not included. VAP was diagnosed by the criteria of the Centers of Disease Control and Prevention (CDC). Incidence of VAP and characteristics of infection were evaluated. Results: In the experimental group, 2 episodes of pneumonia were observed in 40 patients and 1,322 ventilator days. The rate of VAP was 1.5 per 1,000 ventilator days. There was 1 episode of pneumonia in 39 patients and 481 ventilator days for the control group. The rate of VAP was 2.1 per 1,000 ventilator days. The difference between both groups was not significant (p=.695). Conclusion: Extending ventilator circuit change interval from 7 days to 14 days does not increase the risk for VAP.

A Meta-Analysis of the Ventilator Circuit Change Period on Ventilator-Associated Pneumonia (인공호흡기 회로 교환주기가 인공호흡기 관련 폐렴에 미치는 영향에 관한 메타 분석)

  • Song, Ju Hyun;Kim, Kyung Hee
    • Journal of Korean Clinical Nursing Research
    • /
    • v.16 no.3
    • /
    • pp.111-121
    • /
    • 2010
  • Purpose: This meta-analysis was aimed to investigate the evidence of proper period of the ventilator circuit change using existing research. Methods: For this study, 14 published studies between 1995 and 2010 were tested by Macaskill, Funnel Plot, the Odds Ratio of DerSimonian and Laird, Fisher and Liptak analysis. Results: There were no publication bias found in the subjects. The results of the meta-analysis demonstrated no statistically significant differences were observed in neither the Odds Ratio (OR=1.18, 95% CI=0.94-1.47) of the frequency of ventilator-associated pneumonia and the mortality based on the period of the ventilator circuit change (Fisher p=.332, Liptak p=.498), nor the ventilation duration of ventilator (Fisher p=.843, Liptak p=.506), and the hospital length of stay (Fisher p=.254, Liptak p=.480). Conclusion: In order to present more concrete guidelines on the period of the ventilator circuit change, further research is warranted to thoroughly control confounding variables which related to the periods of the ventilator circuit change.

The Effects of Oral Care with Chlorhexidine for Ill Patients to Prevent Ventilator-associated Pneumonia : A Meta-Analysis (중환자의 인공호흡기 관련 폐렴 예방을 위한 클로르헥시딘의 효과 : 메타 분석)

  • Lee, Ha-Nee;Park, Jeong Sook
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.8
    • /
    • pp.241-249
    • /
    • 2017
  • This study was to determine the effectiveness of oral decontamination with chlorhexidine for prevention of ventilator associated pneumonia(VAP) using meta-analysis. MEDLINE, Pubmed, Cochrane library CINAHL and RISS, Koreamed, KISS databases were searched. key words used 'Ventilator-associated pneumonia', 'oral care', 'chlorhexidine' Ninety studies met the inclusion criteria for the meta-analysis. data were analyzed by the Revman 5.3 program of cochrane library and assessed for methodological quality using RoB (The Cochrane's Risk of Bias). The main findings of the current study suggest that chlorhexidine oral care have a positive impact on Ventilator associated pneumonia.

Analysis of Influence Factors on Ventilator-Associated Pneumonia in Severe Trauma Patients (중증 외상환자의 인공호흡기 관련 폐렴 영향 요인 분석)

  • Park, Bit Na;Kim, Eun Joo
    • Journal of Home Health Care Nursing
    • /
    • v.25 no.3
    • /
    • pp.224-231
    • /
    • 2018
  • Purpose: This study was to analyze the factors affecting ventilator-associated pneumonia with severe trauma patients. Methods: This study conducted from May 1, 2018 to May 31, 2018 based on the medical records of the intensive care unit of a university hospital from May 1, 2017 to April 30, 2018 in Gangwon province. The inclusion criteria were 1) Trauma intensive care unit patient, 2) older than 19 years 3) without pneumonia at the time of admission. The collected data were analyzed using descriptive, correlation analysis, ANOVA, t-tests, $x^2$-tests and regression. Results: The severe trauma patients had a total of 2,877 days receiving ventilator, and nine VAP cases. The overall infection rate was 4.0%, and the VAP incidence rate was 3.13 per 1000 ventilator days. VAP in severe trauma patient affected ICU stay(OR=1.03), mechanical ventilator applied day(OR=1.04). Conclusion: Therefore, the development of an individualized VAP prevention bundle and nursing intervention for patients with trauma will be needed and further studies. In addition, there were no findings regarding the relationship between VAP occurrence and the severity of multiple traumatic injuries, so further studies of these factors should be performed.

The Incidence Rate of Ventilator Associated Pneumonia in Relation to the Exchange of Circuit Cycle (인공호흡기 튜브교환주기에 따른 인공호흡기 관련 폐렴발생률)

  • Kim, Nam-Cho;Kim, Yang-Ree
    • Korean Journal of Adult Nursing
    • /
    • v.15 no.3
    • /
    • pp.463-471
    • /
    • 2003
  • Purpose: This study was aimed at providing scientific evidence for minimizing ventilator-associated pneumonia(VAP) by identifying appropriate timing of exchange of circuit for mechanical ventilator that is well suitable for the medical environment of intensive care units of hospitals in Korea. Method: This was a quasi-experimental study with a convenience sample of 19 adult subjects aged over 18 years who were admitted to the NS ICU of C university hospital, and placed on mechanical ventilator. The subjects were placed in two groups, compared on the incidence rate of VAP after they received exchange of circuit either at 1-week interval (N =10) or 2-week interval (N = 9). Result: 1) When considering 1000 days as the standard unit of analysis for incidence, the incidence rate of VAP was 7.19 cases at the 1-week cycle exchange group and 15.23 at the 2-week cycle exchange group, showing no statistically significant difference between the two groups. 2) There were a total of 3 types of bacteria isolated from the patients with VAP, including 2 cases with P. aeruginosa, 1 case with Streptococcus group F and A. baumannii. Conclusion: With thorough hand washing and strict management of tracheal tube of mechanical ventilator as well as use of tracheal intubation techniques, exchange cycle of circuit of mechanical ventilator by nurses may be changed from 1-week to 2-week interval.

  • PDF

Endotracheal Colonization and Ventilator-associated Pneumonia in Mechanically Ventilated Patients according to Type of Endotracheal Suction System (기관 흡인술 유형에 따른 인공호흡기 적용 환자의 기관 내 균집락화와 폐렴 발생률)

  • Cha, Kyeong-Sook;Park, Ho-Ran
    • Journal of Korean Academy of Nursing
    • /
    • v.41 no.2
    • /
    • pp.175-181
    • /
    • 2011
  • Purpose: This study was conducted to identify endotracheal colonization and the incidence of ventilator-associated pneumonia related to the type of endotracheal suction system. Methods: The participants in this study were ICU patients hospitalized between October 2009 to March 2010 who used ventilators for over 48 hr with closed (CSS, n=30) or open (OSS, n=32) suction systems. To standardize the pre-intervention suction system, a suctioning protocol was taught to the ICU nurses. Collected data were analyzed using ${\chi}^2$-test, Fisher's exact test, Wilcoxon rank sums test, Wilcoxon test, Log-rank test and Poisson regression. Results: Endotracheal colonization was higher in OSS than CSS from day 1 to day 8 while using a ventilator and there was a significant difference between the two groups. The CSS reached 50% of endotracheal colonization by the 4th day, whereas for the OSS, it was the 2nd day (p=.04). The incidence of ventilator-associated pneumonia showed no significant difference. Conclusion: For patients with a high risk of pneumonia, CSS must be used to lower endotracheal colonization.

A Survey on Nurses' and Physicians' Knowledge and Educational Needs on Home Ventilator (의료진의 가정용 인공호흡기 관련 지식 정도와 교육요구도 조사)

  • Cho, Soo-Hyun;Go, Myeong-Gyun;Jung, Jin-Hee;Won, Sun-Young;Lee, Hee-Og;Nam, Ji-Myoung;Oui, Mi-Sook;Yi, Young-Hee
    • Journal of Korean Critical Care Nursing
    • /
    • v.5 no.1
    • /
    • pp.56-66
    • /
    • 2012
  • Purpose: The purpose of this study was to investigate the knowledge and educational needs of nurses and physicians on home ventilator. Methods: The participants were 140 nurses and 47 physicians working at departments using home ventilators. The data were collected from January 30 to February 12, 2012 through a self-administered questionnaire with 32 items of the knowledge and educational needs on home ventilator. Results: The mean scores of nurses' and physicians' knowledge were 2.52 and 2.56 respectively. The mean scores of nurses' and physicians' educational needs were 3.16 and 3.06 respectively. Nurses' knowledge was associated with their experience using and receiving education about home ventilator and willingness to receive education about home ventilator education. Nurses' educational needs were associated with their present working department and experience using home ventilator. Nurses with high knowledge were more likely to have high educational needs. Physicians' knowledge and educational needs were not associated with any their general characteristics. Conclusion: Nurses' and physicians' knowledge of home ventilator were low and their educational needs on home ventilator were high. To provide high quality of care for home ventilators, it is necessary to provide nurses and physicians with education and to develop a more specific educational program for them.

  • PDF

Clinical implications of the newly defined concept of ventilator-associated events in trauma patients

  • Lee, Tae Yeon;Oh, Jeong Woo;Lee, Min Koo;Kim, Joong Suck;Sohn, Jeong Eun;Wi, Jeong Hwan
    • Journal of Trauma and Injury
    • /
    • v.35 no.2
    • /
    • pp.76-83
    • /
    • 2022
  • Purpose: Ventilator-associated pneumonia is the most common nosocomial infection in patients with mechanical ventilation. In 2013, the new concept of ventilator-associated events (VAEs) replaced the traditional concept of ventilator-associated pneumonia. We analyzed risk factors for VAE occurrence and in-hospital mortality in trauma patients who received mechanical ventilatory support. Methods: In this retrospective review, the study population comprised patients admitted to the Jeju Regional Trauma Center from January 2020 to January 2021. Data on demographics, injury characteristics, and clinical findings were collected from medical records. The subjects were categorized into VAE and no-VAE groups according to the Centers for Disease Control and Prevention/National Healthcare Safety Network VAE criteria. We identified risk factors for VAE occurrence and in-hospital mortality. Results: Among 491 trauma patients admitted to the trauma center, 73 patients who received ventilator care were analyzed. Patients with a chest Abbreviated Injury Scale (AIS) score ≥3 had a 4.7-fold higher VAE rate (odds ratio [OR], 4.73; 95% confidence interval [CI], 1.46-17.9), and those with a glomerular filtration rate (GFR) <75 mL/min/1.73 m2 had 4.1-fold higher odds of VAE occurrence (OR, 4.15; 95% CI, 1.32-14.1) and a nearly 4.2-fold higher risk for in-hospital mortality (OR, 4.19; 95% CI, 1.30-14.3). The median VAE-free duration of patients with chest AIS ≥3 was significantly shorter than that of patients with chest AIS <3 (P=0.013). Conclusions: Trauma patients with chest AIS ≥3 or GFR <75 mL/min/1.73 m2 on admission should be intensively monitored to detect at-risk patients for VAEs and modify the care plan accordingly. VAEs should be closely monitored to identify infections early and to achieve desirable results. We should also actively consider modalities to shorten mechanical ventilation in patients with chest AIS ≥3 to reduce VAE occurrence.

Secondary Analysis on Ventilator-Associated Pneumonia and Pressure Injury

  • Hyun, Sookyung;Moffatt-Bruce, Susan;Newton, Cheryl;Kaewprag, Pacharmon
    • International Journal of Advanced Culture Technology
    • /
    • v.6 no.3
    • /
    • pp.211-215
    • /
    • 2018
  • Ventilator-associated pneumonia (VAP) is a lung infection that develops in patients receiving mechanical ventilation. VAP contributes to about 50% of hospital-acquired pneumonia in ICU settings. One of the recommendation of the Institute of for Healthcare Improvement ventilator bundle is HOB elevation. HOB elevation affects shearing forces and makes higher risk for pressure injury development. Pressure injury (PI) is localized damage to the skin over a bony prominence. PI prevention guidelines recommend that HOB positioning should be lower to reduce risk for PI development which contradicts VAP prevention guidelines for the HOB between 30 and 45 degrees for ICU patients. This presents a care dilemma and tension. The purpose of this study was to perform a secondary data analysis using cumulative electronic health record data in order to determine the association of HOB elevation with VAP and PI in ICU patients. A secondary data analysis was conducted to determine whether HOB elevation is associated with VAP and PI. HOB elevation was not likely to be associated with VAP prevention whereas it was likely to be related to PI development. This is somewhat contrary to popular data and publications. Prospective cohort study is desired to inform us in an evidence-based fashion what actually is optimal HOB elevation for ventilated patients in ICU settings.