• 제목/요약/키워드: Ventilation window system

검색결과 63건 처리시간 0.028초

한지(韓紙)의 환기성능에 관한 실험적 연구 (The Experimental Study on the Efficiency of Ventilation of Korean Paper (Hanji))

  • 이종원;임정명
    • 설비공학논문집
    • /
    • 제16권5호
    • /
    • pp.482-489
    • /
    • 2004
  • The purpose of this study is to reevaluate the performance of Hanji as a architectural material. Recent studies report that one of the causes of the Sick-HouseㆍSick-Building Syndrome is due to the contaminants from interior materials and the lack of ventilation. In this study, the properties of Hanji are investigated. The major focuses of this research are (1) how efficient the Hanji is for ventilation of the house and (2) whether the usage of Hanji brings required ventilation volume to the house. According to the test results, differential pressure in the air and the amount of ventilation showed linear relationship. Test results differ from various kinds of Hanji. Since houses usually have double window system, Hanji can be used to the windows system, especially for inner part of double window system. It is suggested that the combination of Hanji windows for the inner part and glass windows for outer part is very effective, and offers a solution to improvement of indoor air quality and the lack of ventilation with passive ventilation that has less energy consumption.

하계 공동주택 하이브리드 환기시스템 적용에 따른 실내공기 및 열 환경 평가 (Analysis of Indoor Air & thermal environment with Hybrid Ventilation system during summer)

  • 김상진;김은수;김태연;이승복
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.387-392
    • /
    • 2006
  • The recent on indoor air problem has led to many studies on the methods and effects of ventilation for better indoor air quality. Although natural ventilation is the most effective and energy-saving method in residental housings, the small size of openable window has been a problem in high-rise residential buildings to ventilate only through natural ventilation. Consequently, the installation of mechanical ventilation system has been a requirement in residential buildings, and has caused other problems such as increase of energy consumption and SBS. Hybrid ventilation which uses forces of both natural and mechanical power has been introduced to solve the problem of increase in energy consumption with natural ventilation. In this paper, two types of hybrid ventilation systems in residential building were introduced. One type was with natural ventilation through vent grille in the window, and another type was with natural ventilation through ceiling duct while both types used mechanical ventilation system with the outlets. The indoor temperature distribution and pollution density distribution in summer while operating the ceiling air conditioner were analyzed through CFD simulation. In this paper, the optimal location of diffusers to achieve thermal comfort would be proposed.

  • PDF

한국 전통주거의 기류 분석을 통한 자연통풍 설계 연구 (Natural Ventilation Planning by Analysis on Air Velocity Property of a Traditional Korean House)

  • 최윤정;김인선;허범팔
    • 한국실내디자인학회:학술대회논문집
    • /
    • 한국실내디자인학회 2001년도 춘계학술발표대회 논문집
    • /
    • pp.117-120
    • /
    • 2001
  • This study is a preliminary research to develop design principles for environmentally friendly housing. The purposes of study are to investigate the literatures related passive design for summer and theory of ventilation, to analyze the indoor airflow patterns in traditional Korean house during summer, and to propose the design factors for effective passive cooling system. The analysis for airflow patterns was focused on the ‘An bang’and the ‘Dae Chung’in the ‘An Chae’of a traditional house located in Seoul. Field measurements of air temperature and air velocity were carried out at 30 different measuring points with 8 different window-opening conditions. The measurements were taken on the hottest summer days in August 2000. It is concluded that from an environmentally friendly standpoint design factors to control indoor thermal environment by a passive cooling system during the summer are as follows; ceiling structure has thermal performance like a time-lag effect, optimum height and length of eaves which can prevent sunlight and divert airflow toward the sitting level, building arrangement acceptable the prevailing wind, strategic window arrangement which makes cross ventilation possible (especially north-south) at the sitting level, window opening condition which is possible to intersect two cross-ventilation stream at the main living areas, northward windows remaining in shade to create the air pressure difference, and planning building shape like a bracket that has optimum width and depth.

  • PDF

고속버스 자연환기구의 기류패턴 분석 (Analysis of the Air-flow for Natural Ventilation of Express Bus)

  • 유호천;노경환
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.336-341
    • /
    • 2009
  • In express bus which has no window, the air quality inside the bus is very critical for the passengers who staying for an extended time. Air conditioning system using natural energy is expected to significantly improve the air quality while the bus runs the suburban area. But the express buses today usually attempt to ventilate using air conditioning system, rather than natural ventilation. In this study, analysis of existing ventilation opening and the new ventilation system on roof, using computer simulation. As a result, two cases using existing ventilation device was found to be effective for partial ventilation only, while the air in front remains standstill. The new system proved to have promoted more dynamic ventilation in most of space.

  • PDF

Double Vent 창호 시스템의 단열성능평가 (The Evaluation of Thermal Performance of Double Vent Window System)

  • 유승호;박진우;문현준
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.557-560
    • /
    • 2008
  • Window system is an essential component for ventilation, lighting, and thermal environment in buildings. However, window system has the lowest insulation performance and may cause high energy consumptions, if it is not properly designed. Thus, performance of window systems play an important role in built environment. This study proposes a new window systems for balcony, which has double vents and analyses the thermal performance using an intergrated simulation method with Therm 6.1 and Widow 6.1. The result shows higher U-factor than conventional window systems. It is expected that the double vent window system can increase thermal performance and save energy in apartment houses.

  • PDF

자연환기 시스템을 이용한 고층 공동주택의 환기성능 향상에 관한 연구 (A Study on Improving Ventilation Performance in High-rise Residential Building by Natural Ventilation System)

  • 최태환;김유미;김태연;이승복
    • KIEAE Journal
    • /
    • 제7권4호
    • /
    • pp.51-56
    • /
    • 2007
  • This study focuses on developing natural ventilation system which is able to satisfy the good indoor air quality and air speed. The natural ventilation system developed in this study is for double window façade and it has two operation modes for summer and winter. Operational sections of the devices have been analyzed by CFD simulation to calculate discharge coefficients of openings and estimated indoor air speed. For the analysis of the appropriate installation area ratio for each room and the optimum installation area, TRNFLOW simulation has been used. As the results, we could see that the natural ventilation system can provide the similar pollutant removal performance to 0.7 ACH of mechanical ventilation with appropriate installation area and installation area ratio.

자연환기장치가 적용된 공동주택의 기밀 및 공기유동 성능 실측 연구 (A Study of Measurement on Airtightness and Air-Flow Performance of Apartment Housing Adopting Window Frame-Type Natural Ventilation)

  • 전주영;김길태;김선동
    • 토지주택연구
    • /
    • 제5권4호
    • /
    • pp.325-332
    • /
    • 2014
  • 본 연구에서는 창문형 자연환기장치가 설치된 7개 세대의 소형공동주택($33m^2{\sim}51m^2$)을 대상으로 Blower Door를 이용한 현장 기밀성능 및 공기유동 성능을 측정하였다. 창문형 자연환기장치는 외기에 면하는 모든 창호 및 거실분합문에 설치되어 있으며, 수동 개폐형 장치가 설치되어있다. 본 연구에서는 자연환기장치와 창호의 개폐여부에 따라서 6개의 CASE를 설정하여 실측하였다. 측정결과, 자연환기장치와 모든 개구부를 밀폐한 상태의 기밀성능 값(CASE1)은 1.77~3.12ACH로 평균 2.27ACH로 나타났으며, 문헌조사 결과 자연환기장치가 설치되지 않은 일반 공동주택(1.65~4.28ACH)과 유사하게 나타났다. 내외측의 자연환기장치를 모두 열었을 때의 공기유동성능 값(CASE6)은 평균 5.87ACH로 나타나 밀폐조건과 비교하여 평균 3.6ACH가 증가하는 것으로 나타났다. 외측 환기장치와 창호를 밀폐한 조건에서 내측 환기장치만 개방시와 내측창을 개방시의 공기유동성능값의 차이는 평균 0.29ACH로 내측창호 개방시의 기밀성능 값이 높게 나타났다. 반대로 내측 환기장치와 창호를 밀폐한 조건에서 외측 환기장치만 개방시와 외측창 개방시의 차이는 평균 0.30ACH로 외측창호 개방시가 높게 나타났다. 내측창호만의 공기유동성능과 외측창호만의 공기유동성능 측정값의 차이는 0.77ACH로 내측창호가 더 우수하게 나타났다. 향후에는 자연환기장치와 창호 및 새시의 종류에 따른 기밀성능의 추가 측정을 통해 정량적 상관관계 조사가 필요할 것으로 판단된다.

공동주택의 하이브리드 환기시스템 성능평가 연구 (A Study on the Performance of the Hybrid Ventilation System for Apartment Houses)

  • 전주영;김길태;김상희
    • 토지주택연구
    • /
    • 제3권1호
    • /
    • pp.89-96
    • /
    • 2012
  • 본 연구는 공동주택에서 하이브리드 환기시스템의 적용성을 검토하고, 하이브리드 환기시스템의 성능을 향상하기 위해 CFD시뮬레이션을 이용하여 설계방안을 제시하고자 하였다. 연구대상으로는 전용 $51m^2$, $84m^2$의 공동주택을 선정하였으며, 하이브리드 환기시스템은 창틀자연급기와 각실을 덕트로 연결하여 배기하는 시스템(Hybrid 1)과 창틀자연급기와 욕실 거실배기가 혼합된 시스템(Hybrid 2)을 적용하였다. 이때 각 시스템별 배기구의 위치를 변수로 하여 CFD를 수행하였다. $51m^2$, $84m^2$ 모두 Hybrid 2가 Hybrid 1보다 환기효율이 우수한 것으로 나타났으며, 평균공기연령 또한 낮은 것으로 나타났다. Hybrid 1의 경우, 덕트 배기구의 위치가 각 실 입구에 설치하는 것보다 실 안쪽 모서리에 설치하여 기류이동을 많이 유발할 수 있는 유형이 효과적인 것으로 나타났다. Hybrid 2의 경우, 욕실 고정압팬에 덕트를 연결하여 거실중심에 배기구를 설치하는 시스템이 환기효율이 가장 우수한 것으로 나타났다. 그러나 $51m^2$의 경우 Hybrid 2가 Hybrid 1보다 20%의 향상된 환기효율을 나타낸 반면, $84m^2$의 경우는 14%의 향상된 환기효율을 나타내 공동주택 규모에 따른 적정한 하이브리드 환기시스템에 대한 검토가 필요하다.

오존 정화시스템을 이용한 축사내 공기정화 효과 (Germicidal Effect of Ozone Cleaning System for Pigpens Air)

  • 원승호;김영권
    • 한국태양에너지학회 논문집
    • /
    • 제30권1호
    • /
    • pp.13-18
    • /
    • 2010
  • This research investigated the exhaust gas purification system of gaseous ozone for pigpens. This system is applied to exhaust the gas outside after purification with ozone. This is very effective for purification and simple. And because this is not set in the pigpens, this system is not influence of pollution gas. This is effected to extend the life time of this system and this system is applied for non-window pigpens which does not need the ventilation.

불활성가스 미분무소화설비의 개발 -화재시험실의 급기에 관한 수치연구- (Development of an Inert Gas Water Mist System -A Numerical Study on Ventilation of the Fire Test Room-)

  • 박외철;정이규
    • 한국가스학회지
    • /
    • 제12권1호
    • /
    • pp.25-30
    • /
    • 2008
  • 불활성가스 미분무소화설비의 실험용으로 제작된 $2.5m{\times}2.0m{\times}2.5m$ 크기의 화재시험실에 급기부족 여부를 확인하기 위해, 화재시험실 내 프로판가스 풀(pool) 화재에 대한 수치연구를 수행하였다. 결과의 일관성을 확인하기 위해 설계 화재규모인 60 kW와 그 2배인 120 kW에 대하여 창문의 개폐에 따른 온도 및 일산화탄소 농도의 변화를 조사하였다. 두 화재규모에서 모두 창문의 개폐가 온도 및 CO농도의 변화에 미치는 영향이 작음을 확인하였고, 따라서 급기부족의 발생이 없음을 알 수 있었다.

  • PDF