• 제목/요약/키워드: Ventilation type

검색결과 471건 처리시간 0.026초

자연환기 벤틸레이터 형태에 따른 환기효율 평가 (Evaluation of Ventilation Efficiency for Various Gravity Ventilators)

  • 하현철;김태형
    • 설비공학논문집
    • /
    • 제14권7호
    • /
    • pp.543-551
    • /
    • 2002
  • Gravity ventilators allow the escape of the warm air and air contaminants due to both (either) buoyancy and (or) convection. As a natural ventilation strategy, various gravity ventilators can be installed on the roof. Ventilation efficiency could be affected by various parameters, such as, area of openings, wind velocity and incidence angle, temperature difference between inside and outside, and shape of ventilator. Especially, the shape of roof gravity ventilator might be one of influencing factors for the effective ventilation. The window type gravity ventilators are frequently installed instead of general (standard) gravity ventilator. However, the ventilation efficiencies of them were not proved yet. To compare the ventilation efficiency, general type ventilator and two window type ventilators were numerically tested. Mean age of air, temperature and CO concentration were predicted by using commercial CFD code, AIRPAK (Ver. 2.0) with various conditions. The predicted result showed that general type ventilator is more effective for natural ventilation than window type ventilators.

자연환기용 공장창호의 빗물유입 저감대책에 관한 실험적 연구 (Experimental study on reduction in rain water penetration through industrial windows used for natural ventilation)

  • 박승욱;김태형;하현철;허영빈
    • 한국산업보건학회지
    • /
    • 제20권3호
    • /
    • pp.175-183
    • /
    • 2010
  • Windows are widely used for natural ventilation of the various buildings. Especially high level windows as a part of industrial ventilation systems, play a crucial role in natural ventilation. Compared to mechanical ventilation system, natural ventilation has the advantage of lower installation and operating costs. In general, high level windows for industrial buildings have three types; louver type, 45$^{\circ}$ open type and 90$^{\circ}$ open type. Based on previous studies, it was found that the louver type and 45$^{\circ}$ open type are very effective in reducing rainwater penetration, but they did not have enough ventilation efficiencies. Preliminary tests were performed with the various types of windows. It was found that a 90$^{\circ}$ open double layer type window was the best among those which tested in our preliminary tests. Simulated rain was used to estimate the amount of rain penetrated through windows and to observe the paths of rain penetration. Various 90$^{\circ}$ open windows were tested to find the windows with minimum rain penetration and maximum ventilation efficiency.

주거공간 내 IT기술 적용 에너지 저감 창호형 환기시스템 연구 (A Study on Window Type Ventilation System Using IT Technology for Energy Saving in Housing Space)

  • 이은혜;김용성;지충구
    • 한국주거학회논문집
    • /
    • 제24권2호
    • /
    • pp.61-68
    • /
    • 2013
  • This study has the purpose to adapt IT technology on Window Type Ventilation System for the energy saving and providing of user-centered comfortable environment. This is Derived a look at the case of the window type ventilation system and researched its IT technology for reducing energy applied to the Green Home. This indicates a solution for the established Window Type Ventilation System which can not be satisfied with user's requirement by proposing Window Type Ventilation System applied to IT technology that makes it control the intelligent, combined indoor environment system and providing information. Also, it shows energy saving efficiency of Window Type Ventilation System applied to IT technology based on the model study, analysing the performance of air-conditioning and ventilation energy saving through the experiment to compare with the established Window Type Ventilation System. The result of this study has the significance that it suggests an alternative for energy saving of housing space.

터널형 하우스에서 환기방법이 참외의 생육 및 품질에 미치는 영향 (Effect of the Ventilation Method on the Growth and Quality of Melon (Cucumis melo L.) in Greenhouse of Tunnel Type)

  • 신용습;연일권;도한우;서동환;배수곤;최성국;최부술
    • 생물환경조절학회지
    • /
    • 제5권2호
    • /
    • pp.187-193
    • /
    • 1996
  • 여름철 고온기 참외재배시 환기방법에 따른 시설내 온도차이가 참외의 생육 및 품질에 미치는 영향을 구명하고자 측면환기공 환기구(Type 1), 측면환기공 환가+천정 환기공 환기구(Type 2) 및 권취식 환기구(Type 3)로 구분하여 시험을 실시한 결과를 요약하면 다음과 같다. 1. 환기방법별 온도의 하강효과는 Type 3이 가장 좋았고 Type 2, Type 1의 순으로 나타났다. 2. 환기방법에 따른 온도분포는 측면환기공만 있는 Type 1과 천정환기통 및 측면환기공이 있는 Type 2의 경우 환기공 및 환기통의 면적이 적어 중력환기 및 풍력환기가 미세하여 온도가 상승하였다. Type 3은 측면환기 면적이 넓어 풍력환기에 의한 공기의 유입, 유출이 쉬워 온도분포가 비교적 균일하였다. 3. 실측치를 이용하여 내외기온차이에 의한 환기량을 추정한 결과, Type 3이 Type 1 및 Type 2보다도 많음을 알 수 있었다. 4. 생육 및 상품성을 조사한 결과, Type 3이 Type 2, Type 1보다도 엽수 및 엽면적이 증가하여 생육이 양호하였고 과중, 과육두께, 기형과율, 상품과율 등 상품성도 우수하였다. 5. 수확시기별 상품수량은 각처리 공히 수확초기 보다는 후기로 갈수록 증가하였다. 특히 Type 3에서 뚜렷한 경향을 보였다.

  • PDF

Analysis of Ventilation Performance Using a Model Chamber

  • Kang Tae-Wook;Chang Tae-Hyeon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권7호
    • /
    • pp.736-743
    • /
    • 2005
  • In this study, three different types of mechanical ventilation systems are compared based on their ventilation characteristics: tracer gas concentration decay characteristics, and ventilation effectiveness by calculating actual ventilation air flow rate. The experiments are performed by using a step-down method for measuring tracer gas. $CO_{2}$ gas, concentration in the model chamber. Application of a mixing factor, k, was used and measured values ranged from 0.68 to 0.77. The Type 2 ventilation system was found to have the highest ventilation effectiveness rather than the Types 1 and 3.

환기에 의한 실내 부유오염입자 제거특성에 관한 실험적 연구 (Experimental Study on Removal Characteristics of Indoor Suspended Particulates by Ventilation.)

  • 강태욱
    • 한국태양에너지학회 논문집
    • /
    • 제25권4호
    • /
    • pp.133-139
    • /
    • 2005
  • In this paper, the ventilation performance of suspended particulates in indoor side was investigated by step-down method. Experiments were performed in function of mechanical ventilation types and locations of supply and extract air. The type 2 ventilation system shows the highest removal characteristics rather than other 2 types. It means that the displacement ventilation has also good decay rates of concentration compared to mixing ventilation.

공장창호의 환기특성에 관한 연구 (A Study on Ventilation Characteristics of Industrial Windows)

  • 박승욱;김태형;하현철;허영빈
    • 한국환경과학회지
    • /
    • 제20권5호
    • /
    • pp.581-587
    • /
    • 2011
  • Industrial natural ventilation systems consist of gravity ventilator, the high/low windows and doors. Especially, the high windows play an important role in the industrial natural ventilation systems. Generally speaking, industrial high windows are divided into 3 types; louver type, $45^{\circ}$ open type and $90^{\circ}$ open type. This study was numerically and experimentally conducted. Three types of windows were tested to know the ventilation characteristics and estimate the ventilation efficiencies. Numerically, computational fluid dynamics software (AIR PAK Ver. 2.0) was used to observe the flow characteristics inside the industrial building and the concentration contours generated by the tracer gas method. Experimentally, the flow visualization technique and the tracer gas method were applied with the model building to characterize the flow pattern inside the model building and to estimate the ventilation efficiencies with the different windows. It was found that $90^{\circ}$ open type window was most effective for the discharge of pollutants from the industrial building. On the other hand, the louver type window was found to be less effective than any other windows.

루프 환기구에 따른 보일러빌딩 내부 환기성능에 관한 수치적 연구 (Numerical Study on the Ventilation Performance in the Boiler Building with and without Roof Openings)

  • 최훈기;유근종;이상헌
    • 한국산업보건학회지
    • /
    • 제26권3호
    • /
    • pp.342-349
    • /
    • 2016
  • Objectives: The objective of this paper is to find flow and heat transfer characteristics numerically in boiler buildings for three different ventilation window configurations. Methods: Turbulent natural convection flow in boiler buildings with a constant heating wall temperature was analyzed numerically. Governing equations were solved with standard finite-volume method using the SIMPLE algorithm. Conclusions: Flow and heat transfer characteristics are found for three different ventilation types. In the lower area under furnace, velocity and temperature distributions show similar patterns among the three different ventilation types. In the upper area over furnace, however, air flow is well mixed with lower peak temperatures for types B and C, which have roof ventilation windows, compared to type A which has side wall louvers only. Also, type B, with a single large roof window, shows better ventilation effect than does type C with its distribution roof windows.

환기방식별 실내 환기효율 분석에 관한 실험적 연구 (An Experimental Analysis of Ventilation Effectiveness using Tracer Gas)

  • 강태욱
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권2호
    • /
    • pp.260-266
    • /
    • 2006
  • A tracer gas technique based on ASTM Standard E741-83 was used to measure ventilation performances in a model chamber ($0.84m{\times}0.68m{\times}0.7m$) with an exhaust fan and a supply fan. Experiments were performed for the ventilation effectiveness on three types of mechanical ventilation systems. For all cases. higher ventilation effectiveness was found in the type to ventilation system due to shorter residual time of air compared to type 1 and type 3.

아파트 평면형에 따른 여름철 맞통풍 효과 비교 (A Comparative Study on the Cross-Ventilation Effect by the Floor Plan Type of Apartment House during Summer)

  • 김정민;최윤정
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2005년도 추계학술대회 논문집
    • /
    • pp.301-306
    • /
    • 2005
  • The purpose of this study is to make clear the cross-ventilation effect by floor plan type in apartment house during summer. The questionnaire survey was carried out during the 26$^{th}$ of August ${\sim}$ the 4$^{th}$ of September 2004. The respondents were 174 residents living in two subject apartment estates. One subject estate (we call A estate) was consisted apartment houses having cross-ventilation floor plan. The other subject estate (we cail B estate) was constructed apartment houses having ordinary floor plan. The field measurements of indoor thermal elements reflecting natural cooling effect by cross-ventilation were carried out at A house in A estate and at B house in B estate. The measurements in two subject houses were taken on simultaneously the 27$^{th}$ of August. The residents living in A apartment estate planed cross-ventilation type show positive responses on thermal sensation and airflow sensation. The averages indoor temperature and air velocity in the A house were 0.9 $^{\circ}$C lower and 0.29 m/s higher than the B house. Therefore, it was found that indoor thermal environment during summer in the house having cross-ventilation floor plan maintained more comfortable than the house having ordinary floor plan by natural cooling effect of cross-ventilation.

  • PDF