• 제목/요약/키워드: Ventilation plan

검색결과 138건 처리시간 0.032초

신축 공동주택의 주거환경에 관한 입주자 평가 (A study on the Occupants' Apprasials of Newly Consturcted Apartment)

  • 임인순
    • 한국주거학회논문집
    • /
    • 제4권2호
    • /
    • pp.73-83
    • /
    • 1993
  • Recently, large APT complexes are newly constructed in Taegu city and among them, large APT complexes aggegate densly espically in Weolsung and Jisan complexes of Dalsuh-gu and Susung-gu districts. The purpose of this thesis is to perform occupants' apprasials about residential environment on the housewifes residing at new constructed APT who seem tn have different apprasials on the residential environment by the zones. The results of the investigations are as follows. 1. House possessed type and house sire got elevated in comparison with them before shifting residence in respect to residential property and it was revealed they moved to short distance in the change of their lands. And most occupants could choose their houses by looting-out and there's some difference in the choice motive according to the zones. 2. As a result of studying the relation between demographic and residential properties, there were deep differe-nces in the Possessed house type before move, possessed house size after move, preferenti-al degree of house and move plan. 3. In the degree of satisfaction on residential environment, the result was high in the order of heating facilities, water-supply and draining facilities and lighting and was low in the order of room's size, interior decoration and soundproofin. According to zones, there was a great difference in the items of room's size, privacy, heating facilities, securi-ty from calamity, ventilation, convenience of traffic and school group and facilities for extracurricular activities and the degree of satisfaction was high in Jisan zone in othe items except for room's size and heating facilities. 4. In the tenants' apprasials on tile inside and outside spaces of the zones, important factors were "Cultural Institutions", "Green Areas", "Level of Welfare Facilities" and "Utility degree of welfare facilities" and in the classification of important factors according to the zones, the first and the third factors were changed each other. I think this is because they attached importance to somethings dissatisfied in present circumstances.

  • PDF

COVID-19 소아 환자의 임상 양상 및 실험실적 특징: 체계적문헌고찰 및 메타분석 (Clinical and Laboratory Features of Pediatric Patients with COVID-19: Systematic Review and Meta-analysis)

  • 윤하영;조영아;이정;곽혜선;한지민
    • 한국임상약학회지
    • /
    • 제30권4호
    • /
    • pp.270-278
    • /
    • 2020
  • Background: Although the identification of clinical and laboratory features in pediatric COVID-19 patients is essential in establishing an appropriate treatment plan, a systematic review and meta-analysis on the topic has yet to be reported. Methods: We searched MEDLINE, Embase, and Web of Science to access clinical and laboratory characteristics as well as clinical outcomes of children with COVID-19 infection. A meta-analysis using random-effect model was performed to estimate pooled prevalence and 95% confidence intervals. Results: Among the 532 studies initially collected, 12 articles were finally included in the meta-analysis. Among the investigated 320 pediatric patients with COVID-19, fever (48.2%) and cough (39.3%) were the most common symptoms. Almost one third of patients (30.4%) were asymptomatic. In laboratory findings, only 11.4% of pediatric patients experienced lymphocytopenia. Increased inflammatory markers including c-reactive protein (18.6%) and procalcitonin (32.4%) were observed. Only a few patients needed mechanical ventilation and intensive care support, and only one death was reported. Conclusion: Pediatric patients with COVID-19 infection exhibited milder symptoms and more favorable outcomes compared to adults. However, considering the high rate of asymptomatic pediatric patients, close monitoring is required to prevent community infection in asymptomatic conditions and hidden disease progression.

1인 거주 쉐어하우스 연구에서 만족도 조사항목 추출에 관한 연구 (A Study on the Deduction of Satisfaction Survey Factors in the Study of One-person Living Sharehouse)

  • 김소라;강미현;이민희
    • 한국농촌건축학회논문집
    • /
    • 제24권4호
    • /
    • pp.33-40
    • /
    • 2022
  • Sharehouse has been supplied as an alternative to solving the steadily increasing one-room housing problem of single-person households every year, and it is necessary to investigate the satisfaction of residents who actually live in sharehouse through P.O.E. Therefore, this study analyzed priror researches related to the existing one-person households, sharehouses, and satisfaction surveys, and summarized indicators with high relevance and frequency to derive satisfaction survey factors that can clearly evaluate the improvement architectural plan of sharehouses. As a result, it was classified into 4 items in the 'general information' category to investigate the status, housing rental type, and housing cost of the sharehouse, 15 factors in the 'peripheral environment' category to evaluate the safety, 3 factors in the 'community' category, and 17 factors in the space (facility) and service category. In the "General Information" section, the overall one-person housing satisfaction, desired sharehouse type, housing rental type, housing cost, and living expenses were reduced. In the "Surrounding Environment", accessibility to public office, accessibility to cultural facilities, accessibility to medical facilities, accessibility to work and school, convenience stores, noise pollution and safety. In addition, in the "community" section, it consists of interactions with various people, relationships with housemates and in the "space (facilities) and service" section, heating, waterproof, soundproof, ventilation, moisture and condensation blocking, facility management, interior, room size, built-in furniture, storage space, laundry, parking. Most of the scales for each factor were 5-point Likert scales, allowing evaluation of the degree of satisfaction, and some factors presented criteria to induce structured answers. Therfore, it is expected that the survey will be conducted on residents who actually live by deriving factors for the satisfaction survey of one-person households living in the sharehouse, and the current status of the sharehouse will be identified, and the degree of satisfaction will be analyzed to be used for research.

발진부지를 이용한 초대구경 이수식 쉴드TBM 조립공정 검토 및 개선 사례 (Case of assembly process review and improvement for mega-diameter slurry shield TBM through the launching area)

  • 박진수;전삼수
    • 한국터널지하공간학회 논문집
    • /
    • 제24권6호
    • /
    • pp.637-658
    • /
    • 2022
  • 쉴드TBM 터널은 지반 굴착, 세그먼트 링 빌드(Segment ring-build), 뒷채움의 반복적인 공정으로 단순하다. 재래식 터널공법인 발파공법(Drill and Blast)은 막장관찰, 천공, 장약, 발파, 환기, 버력처리, 지보재 설치의 반복으로 쉴드TBM 터널보다 공정이 복잡하고 일부 제약조건이 따른다. 하지만 굴진을 위한 준비 작업은 지반을 보강하고 갱문조성 후 터널을 형성해 나가는 Drill and Blast에 비해서 쉴드TBM 터널은 매우 상세한 계획을 바탕으로 시간과 비용이 필요하다. 이는 대상지반을 굴착하는 쉴드TBM 장비의 성능 확보가 공사의 성패를 좌우하기 때문인데, 고가의 주문제작 장비인 쉴드TBM이 조립단계에서 잘못 구성되면 본 굴진은 물론 초기굴진 단계에서부터 구동이 어렵게 되고, 조립된 쉴드TBM 장비를 다시 해체하는 경우가 발생하게 되어 재조립하는 상황으로 진행되면, 공기는 물론 경제적인 손실이 발생하여 공사 기간 내내 어려움이 발생한다. 이에 본 연구에서는 한강 하저를 통과하는 국내 최대 직경의 도로터널을 건설하기 위한 이수식 쉴드TBM 조립을 위한 발진부지의 배치와 계획, 쉴드TBM 장비의 주요 부분별 조립공정을 검토하였고, 타공정과 의 간섭 최소화 및 커터헤드 조립과 운반의 효율성을 분석하여 현장여건에 맞게 개선하여 적용하였다.

창호에 SHGC를 반영한 공동주택의 방위각별 에너지 효율성 평가를 통한 합리적인 창호 계획 방안 연구 (A Study on the optimized Performance Designing of the Window of the Apartment based on the Annual Energy Demand Analysis according to the Azimuth Angle applying the Solar Heat Gain Coefficient of the Window)

  • 이장범
    • 대한건축학회논문집:계획계
    • /
    • 제35권11호
    • /
    • pp.25-34
    • /
    • 2019
  • It is important to design windows in a reasonable way considering the performance characteristics of the elements of the window rather than just to increase the thermal energy performance of the window. In this study, the Heat-transfer Coefficient as insulation performance of the windows and together with the grade of the glass's SHGC (Solar Heat Gain Coefficient) were analyzed to relate to the energy efficiency performance of the building by azimuth angle. Based on this basic study, the Heat-transfer Coefficient of windows and the SHGC rating of glass were applied to the unit plan of apartment building, and the Heating and Cooling Demand were analyzed by azimuth angle. Apartment plan types were divided into 2 types of Non-extension and extension of balcony. The designPH analysis data derived from the variant of the Heat-transfer Coefficient and SHGC, were put into PHPP(Passive House Planning Package) to analyze precisely the energy efficiency(Heating and Cooling Demands) of the building by azimuth angle. In addition, assuming the 'ㅁ' shape layout, energy efficiency performance and potential of PV Panel installation also were analyzed by floors and azimuth angle, reflecting the shading effects by surrounding buildings. As the results of the study, the effect of Heat Gain by SHGC was greater than Heat Loss due to the Heat-transfer Coefficient. So it is more effective to increase SHGC to satisfy the same Heating Demand, and increasing SHGC made possible to design windows with low Heat-transfer Coefficient. It was also revealed that the difference in annual Heating and Cooling Demands between the low, mid and high floor households is significantly high. In addition to it, the installation of PV Panel in the form of a shading canopy over the window reduces the Cooling Load while at the same time producing electricity, and also confirmed that absolute thermal energy efficiency could not be maximized without controlling the thermal bridge and ventilation problems as important heat loss factors.

설비공학 분야의 최근 연구 동향 : 2009년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2009)

  • 한화택;이대영;김서영;최종민;백용규;권영철
    • 설비공학논문집
    • /
    • 제22권7호
    • /
    • pp.492-507
    • /
    • 2010
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2009. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends of thermal and fluid engineering have been surveyed as groups of general thermal and fluid flow, fluid machinery and piping, and new and renewable energy. Various topics were covered in the field of general thermal and fluid flow such as an expander, a capillary tube, the flow of micro-channel water blocks, the friction and anti-wear characteristics of nano oils with mixtures of refrigerant oils, etc. Research issues mainly focused on the design of micro-pumps and fans, the heat resistance reliability of axial smoke exhaust fans, and hood systems in the field of fluid machinery and piping. Studies on ground water sources were executed concerning two well type geothermal heat pumps and multi-heat pumps in the field of new and renewable energy. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included the heat transfer in thermoelectric cooling systems, refrigerants, evaporators, dryers, desiccant rotors. In the area of industrial heat exchangers, researches on high temperature ceramic heat exchangers, plate heat exchangers, frosting on fins of heat exchangers were performed. (3) In the field of refrigeration, papers were presented on alternative refrigerants, system improvements, and the utilization of various energy sources. Refrigeration systems with alternative refrigerants such as hydrocarbons, mixed refrigerants, and $CO_2$ were studied. Efforts to improve the performance of refrigeration systems were made applying various ideas of suction line heat exchangers, subcooling bypass lines and gas injection systems. Studies on heat pump systems using unutilized energy sources such as river water, underground water, and waste heat were also reported. (4) Research trend in the field of mechanical building facilities has been found to be mainly focused on field applications rather than performance improvements. In the area of cogeneration systems, papers on energy and economic analysis, LCC analysis and cost estimating were reported. Studies on ventilation and heat recovery systems introduced the effect on fire and smoke control, and energy reduction. Papers on district cooling and heating systems dealt with design capacity evaluation, application plan and field application. Also, the maintenance and management of building service equipments were presented for HVAC systems. (5) In the field of architectural environment, various studies were carried to improve indoor air quality and to analyze the heat load characteristics of buildings by energy simulation. These studies helped to understand the physics related to building load characteristics and to improve the quality of architectural environment where human beings reside in.

서울 도시계획 정책을 적용한 기후영향평가 - 남북녹지축 조성사업을 대상으로 - (Urban Climate Impact Assessment Reflecting Urban Planning Scenarios - Connecting Green Network Across the North and South in Seoul -)

  • 권혁기;양호진;이채연;김연희;최영진
    • 환경영향평가
    • /
    • 제24권2호
    • /
    • pp.134-153
    • /
    • 2015
  • 도시 계획적 측면에서 도시의 구조적 변화에 따른 기후영향을 파악하여 그 결과를 도시계획에 반영하는 것은 중요하다. 서울시에서는 도시계획 시나리오 정보를 제공하기 위해 도시계획정보시스템(Urban Plan Information System, UPIS)을 활용 중이다. 지자체의 실제 도시계획에 따른 기후영향을 평가하고 분석하기 위해서는 UPIS에서 제공하는 도시계획시나리오와 도시기후분석모델을 손쉽게 연계할 수 있어야 한다. 본 연구에서는 국립기상과학원의 도시기후분석모델(Climate Analysis Seoul, CAS)과 도시계획 시나리오를 연계하는 기술을 개발하였다. CAS는 건물과 식생의 물리적 배치에 따른 온도, 바람 등의 국지규모 변화와 중규모 기상모델인 MetPhoMod(METeorology and atmospheric PHOtochemistry mesoscale MODel)의 분석결과를 바탕으로 찬공기의 생성, 이동, 정체와 바람흐름, 열적환경 등을 분석하는 기능을 가지고 있다. 정밀한 도시정보를 모델에 적용하기 위해 고해상도의 항공 LiDAR(LIgit Detection And Ranging) 측량을 통해 생성된 래스터자료(1m 해상도)와 KOMPSAT-2(KOrea Multi-Purpose SATellite) 위성영상 자료(4m 해상도)를 이용하여 토지피복 및 수치표고자료로 활용할 입력자료를 생성하였다. 보다 정확한 도시지면 특징을 반영하기 위해 수치표면모델인 DSM(Digital Surface Model)과 수치지형모델인 DTM(Digital Terrain Model)을 전산유체역학모델(Computational Fluid Dynamics, CFD) 입력자료로 사용하여 상세바람분석을 수행하였다. 8방위의 유입류를 고려하여 재정비 전후의 도시구조물 주변의 흐름 및 풍속 분포와 녹지축 형성 전후의 열환경 변화를 분석하였다. 현실적인 기상상태 반영을 위해 CAS의 중규모 기상장을 입력자료로 사용하였으며, 그 결과 재정비에 따른 도시구조물 변화에 의해 바람길에 큰 변화가 확인되었다. 녹지축 형성 이후 전반적으로 재정비지역 주변의 온도가 감소하였다. CAS와 CFD의 연동을 통해 도시지역 재정비와 녹지축 형성 전후의 주변 바람길과 열환경에 대한 실제적인 평가가 가능하며, 도시개발계획과 녹지조성계획 수립에 유용할 것으로 기대된다.

자연환기식 육계사내의 환기효율성 조사연구-( I )하절기 (Study on Ventilation Efficiency of A Naturally Ventilated Broiler House-( I ) Summer Season)

  • 이인복;유병기;정문성;윤진하;전종길;김경원;성시흥
    • 한국축산시설환경학회지
    • /
    • 제9권1호
    • /
    • pp.9-18
    • /
    • 2003
  • 국내 대형육계사의 최적환기구조 개발을 주요환경요소의 적정성, 안정성, 균일성 등의 기초자료가 매우 부족한 실정이어서, 자연환기식 계사에서 하절기동안 기상데이터와 함께 육계사내 주요환경 변수를 시간별로 측정하였다. 이 연구의 목적은 자연환기식 육계 사내의 주요환경 요소 및 환기효율성 등을 정확하게 이해하고, 현 시설 및 환기구조상의 문제점을 파악하고자 함이었다. 이 자료는 앞으로 공기유동분석 등 공학적 접근을 통한 시설 및 환기구조 개선연구를 위한 기초자료로 활용할 계획이며, 실험결과는 다음과 같다. 1. 자연환기식 계사내 온도는 외부기상의 변화, 환기제어의 어려움, 닭의 성장 등으로 인하여 적정성 및 안정성이 많이 부족하였다. 계사내 평균온도는 적정온도와 최대 $14.0^{\circ}C$ 차이가 발생하였고, 일별 낮과 밤 온도차는 최대 $10.5^{\circ}C$가 발생하였다. 계사내 0.4m 높이에서의 시간별 온도 균일성은 최대 $5.2^{\circ}C$가 발생하였다. 2. 시험기간 중 계사내 평균습도는 최대 89.3%, 평균 73.7%, 최저 49.2%이었고, 지점별로 측정된 최대 및 최소습도는 각각 95.1%와 47.2%이었다. 외부 기상변화에 따라 불안정한 것으로 나타났다. 3. 시험기간 중 열량계수는 각각 최대 2,787, 평균 2,185, 그리고 최소 1,432이었으며, 사육기간의 약 98% 이상이 더위에 대한 대책이 필요하거나 아주 위험한 상태이었다. 4. 환기량을 최대로 유지하는 하절기 동안, 계군에서의 암모니아가스와 분진농도는 닭의 성장과 함께 꾸준하게 증가하여 각각 최대 15ppm와 0.38mg/$m^3$이었다. 5. 계사 중앙에 계군에서 측정된 공기유속은 평균 0.9m/s이어서, 하절기동안 자의 열적스트레스를 줄이기 위하여 계군에서의 공기 유속을 증가시킬 필요성이 있다. 또한 외부풍속이 매우 낮은 경우에도 적정환기량을 유지할 수 있도록 배기 덕트에 팬을 설치하는 것이 필요하다. 6. 계사내 바닥의 표면온도는 최저 $30.6^{\circ}C$와 최고 $37.3^{\circ}C$로 측정되었다. 하절기동안 닭의 열적스트레스를 줄이기 위하여 계군에서의 공기유속을 증가시킬 수 있는 환기구조개발이 시급하였다.

  • PDF

한남금북·금북정맥 일대의 찬공기 특성 분석을 통한 청주시 찬공기 관리방안 (Analysis and Management Strategies of the Cold Air Characteristics in Hannamgeumbuk-Jeongmaek and Geumbuk-Jeongmaek)

  • 손정민;엄정희
    • 한국지리정보학회지
    • /
    • 제22권2호
    • /
    • pp.152-171
    • /
    • 2019
  • 본 연구는 한남금북정맥과 금북정맥을 대상으로 정맥에서 생성되는 찬공기의 특성을 분석하고 이를 관리하기 위한 방안을 마련하였다. 또한 한남금북정맥에 위치한 청주시를 대상으로 상세 찬공기 흐름을 파악한 후 관리전략을 제안했으며, 청주시 내에 설치된 지상기상관측소의 관측자료를 이용하여 정맥의 야간기온저감 특성을 분석하였다. 찬공기 특성 분석을 위해서 독일에서 개발된 KALM(Kaltluftabflussmodell) 모형을 활용하여 야간 6시간 동안 생성되는 찬공기 흐름 및 풍속, 그리고 찬공기 층 높이를 파악하였다. 분석 결과, 시간이 경과함에 따라 정맥에서 생성되는 찬공기는 강해졌으며, 특히 한남금북정맥의 서쪽과 금북정맥의 북쪽에서 뚜렷하게 나타났다. 찬공기 생성 360분 경과 후에는 평균적으로 약 0.45m/s의 찬공기 풍속이 분석되었으며, 최대 2.70m/s의 풍속이 관찰되었다. 찬공기 층 높이는 평균적으로 104.27m, 최대 255.00m의 두께로 쌓였다. 청주시의 찬공기 흐름의 풍속은 상당구가 0.51m/s로 평균적으로 높게 나타났으며, 찬공기 층의 높이는 흥덕구가 48.87m로 높게 분석되었다. 야간기온저감 효과 분석 결과는 찬공기 층이 높은 청남대관측소($-3.8^{\circ}C$)에서 저감정도가 가장 크게 나타남으로써, 정맥에서 생성된 찬공기의 영향이 야간기온저감에 효과를 미치고 있음을 확인할 수 있었다. 이러한 찬공기 특성 분석 결과를 바탕으로 찬공기 생성이 활발한 정맥의 주요 산지 일대를 '온도조절기능 보전지역'으로 지정하여 현재의 산림 및 지형 보전에 대해 제안했으며, 생성된 찬공기의 흐름을 원활하게 해주는 지역을 '온도조절기능 확대지역'으로 지정하여 정맥의 기능을 보완할 수 있도록 제안하였다. 본 연구의 결과는 한남금북정맥과 금북정맥의 체계적인 관리계획을 수립하고, 향후 청주시의 바람길 계획 수립시 기초자료로 활용할 수 있을 것으로 기대한다.

화생방 방호시설의 행동 절차 분석을 통한 진입 소요시간 예측 시뮬레이션 (Chemical/Biological/Radiological Protective Facility Entering Time Estimation Simulation with Procedure Analysis)

  • 박선호;이현수;박문서;김수영
    • 한국건설관리학회논문집
    • /
    • 제15권5호
    • /
    • pp.40-48
    • /
    • 2014
  • 최근 화생방 공격에 대한 위협이 증가함에 따라 화생방 방호시설의 중요성이 강조되고 있다. 화생방전 발생 시 화생방 방호시설 외부에 있는 작전인원은 화생방 방호시설 내 오염통제구역 및 무해구역에서 제독과정을 거쳐 방호시설 내부로 진입하게 된다. 이 과정에서 부족한 설비 등으로 인해 특정 절차 및 구역에서 병목현상이 발생할 경우 작전인원은 제시간에 방호시설 내로 진입 할 수 없게 되며, 이는 전시 작전 수행의 효율성 저하뿐만 아니라 큰 인명피해로도 이어지게 된다. 현재의 화생방 방호시설 설계기준은 공조시스템 등 특정 설비에 국한되어 있으며, 실제 화생방전 발생 시 실제 진입 소요시간을 고려한 설계기준은 부재한 실정이다. 본 연구에서는 화생방 방호시설 진입 소요시간에 크게 영향을 미치는 요소를 시뮬레이션에 반영하여 화생방 방호시설 진입 소요시간을 예측하는 시뮬레이션 모델을 개발하였다. 이를 위해 오염통제구역 및 무해구역에서 이루어지는 행동절차를 세분화하고, 각 행동절차에 소요되는 실제 시간을 측정하여 이를 시뮬레이션에 적용하였다. 또한 진입 소요시간에 영향을 미치는 요인들을 선정하여 이들의 조절을 통해 대안을 작성하고 각 대안별 진입 소요시간 및 전체결과에 미치는 영향을 분석하였다. 이 모델은 향후 화생방 방호시설 진입 시뮬레이터의 모듈로써 활용될 수 있으며 방호시설 설계 및 운용자의 의사결정 기초자료로 활용될 수 있다.