• Title/Summary/Keyword: Ventilation plan

Search Result 138, Processing Time 0.024 seconds

Analysis of Patient Outcome using Nursing Outcomes Classification(NOC) (Nursing Outcomes Classification(NOC)를 이용한 일부 입원환자의 간호결과에 대한 분석)

  • Kim, Su-Hyun;Son, Jung-Tae;Lee, Eun-Joo
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.12 no.2
    • /
    • pp.181-188
    • /
    • 2006
  • Purpose: The purpose of study was to determine differences in patient outcomes that exists in terms of Nursing Outcomes Classification (NOC) during hospital days of neurosurgical and respiratory patients. Method: Before starting clinical practicum, nursing students were received two hours' lecture on how to apply NOC to patient care plan and they were required to evaluate patient condition using NOC at the beginning and at the end of their clinical practicum. Data were extracted from 62 neurosurgical patients and 66 respiratory patients and analyzed by frequency and paired t-test. Results: The most frequently used NOC were Pain Level (37.1%), Mobility Level (25.8%), and Bowel Elimination (19.4%) in neurosurgical patients and Nutritional Status (37. 9%), Respiratory Status: Ventilation (37.9%) and Pain Level (25.8%) in respiratory patients. The numbers of outcomes used were 75 and 46 neurosurgical and respiratory patients respectively. During the hospital days, the level of patient outcomes increased significantly in all patient groups. Conclusion: The finding clearly suggests that nursing interventions make differences in patient outcomes and make contribution to the patient health achieved. To more effectively use NOC, however, nursing information system should be developed and included standardized nursing languages regarding nursing diagnoses and interventions.

  • PDF

An Analysis of Heating Energy Performance in Housings of ICF Method with Passive Design Applied (패시브 디자인을 적용한 ICF공법 주택의 난방에너지 성능 분석)

  • Kim, Jun-Hui;Lee, Tae-Gu
    • KIEAE Journal
    • /
    • v.13 no.3
    • /
    • pp.33-40
    • /
    • 2013
  • The world population is consuming more than 1/3 of the total energy for heating housings. Particularly in our country, 21% of the consumption energy is occupied by building section. Therefore, it is necessary to increase the energy efficiency in buildings, thus promoting a comfortable residential environment while minimizing energy consumption. Accordingly, this study presents considerations for implementing high-insulated and airtight passive houses. This study selected four houses with passive house design applied, performed building energy performance through PHPP2007, a German passive house design simulation program, and compared the building-specific heat loss and heat gain. As a result, the most vulnerable part to heat loss was turned out to be a window and the heat loss was caused by outer wall, roof, and ventilation. Accordingly, for the implementation of passive house, it is necessary to make a careful plan and airtight construction that are complementary to various parts through the energy performance analysis started from the design phase.

An Ecological Approach to Housing Experience of Korean Women in Malaysia (생태학적 접근으로 본 말레이시아 거주 한인 여성의 주거경험)

  • Hong, Hyung Ock
    • Human Ecology Research
    • /
    • v.53 no.4
    • /
    • pp.375-390
    • /
    • 2015
  • This study was designed to understand the residential experience of Korean women living in tropical country. For qualitative research, interviewees were selected by snowball sampling among Korean women living in Malaysia for over 20 years. The selection criteria for interviewees included husband's nationality, occupational experience, future living plan, frequency of travel to Korea. In-depth group and individual interviews were conducted from August 23 to October 7 2014. Subsequently (1) interviewees' general residential experiences in Malaysia were summarized, (2) interviewee's identity and lifestyle with housing pathways approach were clarified, (3) interviewees' residential experiences in 5 issues, reciprocity in residential area, intention of environmental change, meaning of housing and interaction, housing adaptation, and residential satisfaction/dissatisfaction were prescribed and interpreted. In conclusion, the reflection of interviewees' experiences in tropical country, suggested variations of housing structure type within a residential complex, air well and pocket by setback in building block for improving ventilation and noise prevention from neighbors, and ceiling fans in the house were suggested for the upcoming subtropical climate in Korea. Full option and minus options were also suggested for the presale market to reduce before occupancy remodeling needs. The research results implies valuable suggestions for a multicultural society, ecological housing and stronger communities.

A study on university office worker's perception of indoor air quality (Focused on K university) (사무실 근로자들의 실내공기질 인식에 관한 기초 조사 (K대학교를 중심으로))

  • Shin, Eun-Young;Kim, Gwang-Hee
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.16 no.3
    • /
    • pp.69-76
    • /
    • 2017
  • Indoor Air Quality(IAQ) affects physical and mental state of person who is residing indoor. Also, it manages daily life condition of Indoor Air in the building. According to the study, office workers spend 23 hours and 12 minutes, about 97% of his/her day indoor. Therefore, Indoor air quality affects not only the health of the person whose staying inside for a long hours but also the productivity and efficiency of work. This study conduct investigations on employees' awareness of indoor air quality of office in university. By doing so, we are able to determine current situation and provide basic data of improvement for derived problems. As a result, most of the respondents were not satisfied with ventilation and moisture which are elements of Indoor Air Quality. These led people to struggle with symptoms of health. Therefore, to improve the indoor air quality of a university office, it is necessary to exchange the air six times an hour according to recommendation of Refrigeration and Air Conditioning Engineers (ASHRAE)in the United States. Also, plan for Ventilation system that consider temperature, humidity and air flow indoor shall be provided for high quality conformability. furthermore, It is necessary to consider the multilateral in factors of generation of revenue through health care savings of workers and improvement of productivity.

An Evaluation of Human Thermal Comfort and Improvement of Thermal Environment by Spatial Structure (공간 구조별 열쾌적성 평가와 열환경 개선방안)

  • Lee, Jung-A;Jung, Dae-Young;Chon, Jin-Hyung;Lee, Sang-Moon;Song, Young-Bae
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.38 no.5
    • /
    • pp.12-20
    • /
    • 2010
  • The purpose of this study is to evaluate human thermal comfort by spatial structure and to explore solutions to improve the thermal environment of a small urban space. The study site was Korea University campus. Thermal conditions were measured to evaluate the quality of the thermal environment in each type of space within the study site. Micrometeorology measurements, analysis of space characteristics for using fish-eye lens photography, and thermal comfort modeling through the use of collected meteorological data, such as temperature and humidity, were performed. Results showed that the level of thermal comfort for humans differs depending on the types of space within the study site. Thermal comfort is better in open spaces than enclosed in the aspect of radiative mean temperature, Predicted Mean Vote(PMV), and Physiologically Equivalent Temperature(PET). This fact is probably due to shadows or buildings or trees that may block solar radiation. Thus, it is necessary to consider the spatial arrangements of buildings and trees to enhance openness and ventilation in the space. Paving materials and exterior building materials should also be selected to lower the radiant temperature. Given these results, a quantitative evaluation on human thermal comfort could propose a way to plan user comfortable small urban spaces. Study methods used and results provided in the study can promote a better way for urban space planning direction to improve environmental quality.

Proposal for Ignition Source and Flammable Material Safety Management through 3D Modeling of Hazardous Area: Focus on Indoor Mixing Processes (폭발위험장소 구분도의 3D Modeling을 통한 점화원 및 가연물 안전관리 방안 제안: 실내 혼합공정을 중심으로)

  • Hak-Jae Kim;Duk-Han Kim;Young-Woo Chon
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.1
    • /
    • pp.47-59
    • /
    • 2024
  • Purpose: This study aims to propose measures for the prevention of fire and explosion accidents within manufacturing facilities by improving the existing classification criteria for hazardous locations based on the leakage patterns of flammable liquids. The objective is to suggest ways to safely manage ignition sources and combustible materials. Method: The hazardous locations were calculated using "KS C IEC 60079-10-1," and the calculated explosion hazard distances were visualized in 3D. Additionally, the formula for the atmospheric dispersion of flammable vapors, as outlined in "P-91-2023," was utilized to calculate the dispersion rates within the hazardous locations represented in 3D. Result: Visualization of hazardous locations in 3D enabled the identification of blind spots in the floor plan, facilitating immediate recognition of ignition sources within these areas. Furthermore, when calculating the time taken for the Lower Explosive Limit (LEL) to reach within the volumetric space of the hazardous locations represented in 3D, it was found that the risk level did not correspond identically with the explosion hazard distances. Conclusion: Considering the atmospheric dispersion of flammable liquids, it was concluded that safety management should be conducted. Therefore, a method for calculating the concentration values requiring detection and alert based on realistically achievable ventilation rates within the facility is proposed.

Analysis of Microclimate in Apartment Complex by Age (시대별 아파트 단지의 미기후 분석)

  • Kim, Chul-Hee;Jung, Eung-Ho;Kim, Dae-Wuk;Cha, Jae-Gyu
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2009.11a
    • /
    • pp.104-108
    • /
    • 2009
  • Rapid urbanization resulted in expansion of urban area and increase of population bringing deepened housing shortage. Supply-oriented housing policy made apartment a representative residential space in Korea in spite of the short history of apartment. This study analyzed the shape and arrangement of main building by year and the microclimate in the complex depending on the number of floors. The purpose of this study was to present the basic data in developing apartment complex to solve problems like the stagnation of pollution source and the rise of temperature due to the declined ventilation in apartment complex, and the worsened urban heat island phenomenon due to the impeded flow of wind. This study rearranged the shape and arrangement of main building by year and the tendency of the number of floors by year in the process of change, by generalizing the process of change of apartment complex, a representative modern residential space through preliminary research. Based on it, 8 object lot by age was selected and simulated by using Envi-met. Simulation identified that the change of apartment complex takes place having a positive effect on microclimate in the apartment complex and the microclimate in the apartment complex is influenced a lot by the shape of complex. If in future apartment complex plan, a systematic legal criteria of design is made about the shape and arrangement of main building, it might have a positive effect on the improvement of microclimate in the apartment complex, a representative residential space in Korea.

  • PDF

Design Checklist for Self-sufficient Zero Energy Solar House(ZeSH) (에너지자립형 태양열 주택의 설계 및 시공 방법 체크리스트 수립 연구)

  • Yoon Jongho;Baek Namchoon;Yu Changkyun;Kim Jongil
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.416-421
    • /
    • 2005
  • Most of solar system dissemination has been focused on domestic hot water system of which utilization to a building is relatively simple and safe than solar heating system. Through the survey on a cause of solar house dissemination failure in Korea, we conclude that design integration and systematic approach method for technology application are the most important element for a successful solar house. KIER(Korea Institute of Energy Research) and Hanbat National University have started new project on a development of Zero energy Solar House, called ZeSH which can be sustained just by natural energy without the support of existing fossil fuel. This is the 1st phase research of 10 years long-term ZeSH plan which develops a low-cost and $100\%$ self sufficient ZeSH. The goal of 1st phase ZeSH research is to get a $70\%$ self sufficiency only in thermal loads. Actual demonstration house, named KIER ZeSH I was designed and constructed as a result of 1st phase research work in the end of 2002. Various innovative technologies such as super insulation, high performance window, passive and active solar systems, ventilation heat recovery system are applied and evaluated to the KIER ZeSH I. A lot of computer simulations had been conducted for the optimal design and system integration in every design steps. Considering all the results from detailed hourly computer simulation, it is expected that at least $70\%$ self-sufficiency in thermal loads which is 1st phase target value can be excessively achieved in actual demonstration house. Besides, many valuable findings from the design and analysis to construction could be established such as collaboration method among the participants, practical design and construction techniques for system integration and the others. The purpose of this paper is to introduce the main findings through the development of KIER ZeSH I project. Practical guidelines in every design step for new low- or zero- energy solar house is proposed as result.

  • PDF

A Study of Smoke Movement in a Short Tunnel (짧은 터널 내의 연기거동에 관한 연구)

  • Kim, Sung-Chan;Ryou, Hong-Sun;Kim, Chung-Ik;Hong, Ki-Bae
    • Tunnel and Underground Space
    • /
    • v.12 no.1
    • /
    • pp.31-36
    • /
    • 2002
  • This paper concerns smoke propagation in tunnel fires with various size of fire source. Experiments carried out in model tunnel and those results were compared with numerical results. The Froude scaling law was used to scale model tests for comparison with larger scale tests. In order to validate for numerical analysis, temperature distribution of predicted data was compared with measured data. Examining the temperature distribution, we found that smoke layer does not come down under 50% of tunnel heights for a short tunnel heights for a short tunnel firs without ventilation. Front velocity of smoke layer is proportional to the cube root of heat release rate. And it is in good agreement with existing empirical expression and numerical prediction. In a short tunnel fire, horizontal propagation of smoke layer is more important than vertical smoke movement for evacuation plan.

A Case Study on Active Usage of the Storage Space Outside Housing Unit of Residential Complex (공동주택 세대외부창고의 활성화 방안을 위한 사례 연구)

  • Song, Jihyun;Lee, Hyunsoo
    • Korean Institute of Interior Design Journal
    • /
    • v.27 no.1
    • /
    • pp.58-67
    • /
    • 2018
  • This study aims to analyze the cases of storage space outside housing unit and propose the activation plan. The issue of storage in residential complex has continued to be reported. This is more salient due to the recent preference trend for small houses, the constant increase of living goods and the limitation of the available space inside housing unit. Although more apartment houses are trying to have individual storage in the exterior space to address these issues, there is still a paucity of the related studies and more studies are required. In this study, we conducted on-site investigation and user interview of each case to propose active usage of the storage space outside housing unit. Result of this study shows that the most crucial factor to improve is 'accessibility' in order to activate the storage space. Storage room should be located close to each household or the individual parking space. The second factor is the size and the structure of the storage room. The sufficient space for keeping and taking large objects out are required. The front of the storage room should have a clogged structure to insure privacy. The third is the provision of suitable support programs such as the system that occupants can check remotely what items are in their storage rooms, garage sale, laundry service, auto cleaning system and rental program. Those programs are required for efficient management and activation of space. Another requirement is to improve environmental factors which include maintenance of optimal temperature and humidity, automatic ventilation system, control of individual lights, and security enhancement. Based on the results of the survey, we provide basic data which can be used for practical space planning to activate exterior storage space of the housing unit. Further surveys are required to develop this study by obtaining more data for generalization.