• Title/Summary/Keyword: Ventilation frequency

Search Result 143, Processing Time 0.027 seconds

A study on the evaluation of fire safety according to the ventilation mode in a train fire at the subway platform (지하철 승강장에서 열차 화재시 제연모드에 따른 화재 안전성 평가 연구)

  • Ryu, Ji-Oh;Lee, Hu-Young
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.22 no.3
    • /
    • pp.293-310
    • /
    • 2020
  • The purpose of this study is to present the most effective smoke exhaust mode by comparing the quantitatively evaluated risks according to the smoke exhaust mode when a train fire occurs in a subway platform. Therefore, applying the typical subway platform as a model, train fire scenarios are developed with the evacuation start time and location of the fire train for each exhaust mode. The fire accident rates (F) are calculated and the number of fatalities (N) was quantitatively estimated by fire analysis and evacuation analysis for each scenario. In addition, the F/N curve compared with the social risk assessment criteria and the following conclusions were obtained. In the event of a train fire at the subway station platform, the evacuation must start up within 600 s in maximum to ensure the evacuees' safety. To secure evacuation safety, it is advantageous to operate the HVAC system of the platform in the air-supply mode at station without TVF. Comparing the F/N curve for each exhaust mode with the social risk criteria, it turned out that the risk significantly exceeds the social risk criteria in case of no mechanical ventilation. As a result, this paper shows that the ventilation mode in which TVF are exhausted and HVAC system is operated in the pressurized mode are the most effective smoke exhaust mode for ensuring evacuation safety.

A Study on the Effects of Early Surfactant Replacement and Gentle Ventilation in the Treatment of Respiratory Distress Syndrome (미숙아 호흡 곤란 증후군에서 폐 표면 활성제의 조기 투여와 연성 환기 요법의 치료 효과에 관한 연구)

  • Lee, Yong Suk;Lee, Ji Hye;Lee, Sang Geel
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.10
    • /
    • pp.1096-1101
    • /
    • 2005
  • Purpose : Recently, early surfactant replacement and tidal volume based gentle ventilation has been a fundamental treatment of respiratory distress syndrome(RDS). The aims of this study were to survey the changes in ventilator care duration and rate of complication in RDS groups. Methods : We performed a retrospective study of 255 newborn infants less than 1,500 g admitted to the neonatal intensive care unit(NICU) and discharged from January 1999 to December 2003. 141 of 255 newborn infants were RDS groups that required invasive management, such as endotracheal intubation, surfactant replacement and assisted ventilation. We analyzed epidemiologic data to study the changes in ventilator care duration and outcome of RDS groups. Results : Of 141 RDS groups, 135 were mild to moderate RDS groups and only 6 were severe RDS groups. 24(17.8%) of 135 mild to moderate RDS groups and 3(50%) of 6 severe RDS groups were antenatal no use of maternal dexamethasone. 127(90.1%) of 141 RDS groups underwent replacement of surfactant during 3 hours after birth. 121(85.9%) weaned within 48 hours. Conclusion : Our study shows a decreased frequency of severe RDS by a antenatal use of maternal dexamethasone and decreased duration of ventilator care by early surfactant replacement and gentle ventilation.

Correlation of Tracheal Cross-sectional Area with Parameters of Pulmonary Function in COPD (만성 폐쇄성 폐질환에서 기관의 단면적과 폐기능지표와의 상관관계)

  • Lee, Chan-Ju;Lee, Jae-Ho;Song, Jae-Woo;Yoo, Chul-Gyu;Kim, Young-Whan;Han, Sung-Koo;Shim, Young-Soo;Chung, Hee-Soon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.5
    • /
    • pp.628-635
    • /
    • 1999
  • Background : Maximal expiratory flow rate is determined by the size of airway, elastic recoil pressure and the collapsibility of airway in the lung. The obstruction of expiratory flow is one of the major functional impairments of emphysema, which represents COPD. Nevertheless, expiratory narrowing of upper airway may be recruited as a mechanism for minimizing airway collapse, and maintaining lung volume and hyperinflation by an endogenous positive end-expiratory pressure in patients with airflow obstruction. We investigated the physiologic role of trachea in respiration in emphysema. Method : We included 20 patients diagnosed as emphysema by radiologic and physiologic criteria from January to August in 1997 at Seoul Municipal Boramae Hospital. Chest roentgenogram, high resolution computed tomography(HRCT), and pulmonary function tests including arterial blood gas analysis and body plethysmography were taken from each patient. Cross-sectional area of trachea was measured according to the respiratory cycle on the level of aortic arch by HRCT and calibrated with body surface area. We compared this corrected area with such parameters of pulmonary function tests as $PaCO_2$, $PaO_2$, airway resistance, lung compliance and so on. Results : Expiratory cross-sectional area of trachea had significant correlation with $PaCO_2$ (r=-0.61, p<0.05), $PaO_2$ (r=0.6, p<0.05), and minute ventilation (r=0.73, p<0.05), but inspiratory cross-sectional area did not (r=-0.22, p>0.05 with $PaCO_2$, r=0.26, p>0.05 with $PaO_2$, and r=0.44, p>0.05 with minute ventilation). Minute ventilation had significant correlation with tidal volume (r=0.45, p<0.05), but it had no significant correlation with respiratory frequency (r=-0.31, p>0.05). Cross-sectional area of trachea had no significant correlation with other parameters of pulmonary function including $FEV_1$, FVC, $FEV_1$/FVC, peak expiratory flow, residual volume, diffusing capacity, airway resistance, and lung compliance, whether the area was expiratory or inspiratory. Conclusion : Cross-sectional area of trachea narrowed during expiration in emphysema, and its expiratory area had significant correlation with $PaCO_2$, $PaO_2$, and minute ventilation.

  • PDF

Physiological Analysis of Walking - Physical Exercise for the Promotion of National Health - (걷기의 생리학적 분석 - 체력 증진을 위한 운동 -)

  • Nam, Kee-Yong;Chang, Shin-Yo;Shin, Dong-Hoon;Sung, Nak-Eung;Earm, Yung-E
    • The Korean Journal of Physiology
    • /
    • v.4 no.1
    • /
    • pp.1-11
    • /
    • 1970
  • Studies on the analysis of walking were performed on 33 male subjects. A prescription of physical exercise (walking at a speed of greater than 6 km/hr for more than one hour daily) for the promotion of individual health is presented on the basis of walking analysis. Presumptions were made that adequate physical exercise does promote health and is beneficial for the healthy life and increases the life span. These presumptions were derived from the numerous experimental literatures. The literatures support indirectly the presumptions. The following results were obtained and prescription of physical exercise is presented. 1. Oxygen uptake in a walking on a treadmill at a speed of 4 km/hr was only 3 times of the resting oxygen uptake. This kind of moderate exercise did not stimulate the cardiopulmonary system adequately. Heart rate at a 4 km/hr walking was 101 beats/min in boys of less than 20 years old and 83 beats/min in adults. Oxygen uptake at a 6 km/hr walking exceeded 4 times of the resting oxygen uptake. It was interpreted that walking at 6 km/hr stimulated the cardiopulmonary system for the promotion of health. Heart rate at this speed was greater than 110 beats/min in boys and greater than 100 beats/min in adults. 2. Heart rates in a walking of 10 km/hr were 172 beats/min in boys, and 143 beats/min in adults, respectively. Maximal heart rates were 185 beats/min in boys, 180 in office clerks, and 168 beats/min in construction site laboreres. 3. The correlation between heart rate and oxygen uptake was high, namely, r>0.95. Subsequently heart rate could be used as a measure of degree of intensity of physical exercise instead of the cumbersome oxygen uptake measurement. 4. The prescription of physical exercise for the promotion of health is: Daily walking for more than one hour at a speed of greater than 6 km/hr. Bodily functions in this daily walking are in boys (body weight, 50 kg): heart rates of 110 beats/min; breathing frequency, 28/min; oxygen uptake, greater than 4 times of the resting uptake; pulmonary ventilation, 351/min; stride, 124 strides/min; cumulative number of strides for one hour, 7,440 strides, and energy expenditure of more than 300 kcal. In adults (body weight, 60 kg) the bodily functions are: heart rates of 100 beats/min, breathing frequency, 28/min; oxygen uptake, greater than 4 times of the resting uptake; Pulmonary ventilation, 301/min; stride, 127 strides/min; cumulative number of strides for one hour, 7,670 strides, and energy expenditure of more than 300 kcal.

  • PDF

Design and Evaluation of a Lung Assist Device for Patients with Acute Respiratory Syndrome using Hollow Fiber Membranes (중공사 막을 이용한 급성호흡곤란증후군 환자용 폐 보조 장치의 설계와 평가)

  • Lee, Sam-Cheol;Kwon, O-Sung;Kim, Ho-Cheol;Hwang, Young-Sil;Lee, Hyun-Cheol
    • Membrane Journal
    • /
    • v.15 no.3
    • /
    • pp.224-232
    • /
    • 2005
  • The use of the lung assist device (LAD) would be well suited for acute respiratory failure (ARF) patients, combining the simplicity of mechanical ventilation with the ability of extracoporeal membrane oxygenators (ECMO) to provide temporary relief for the natural lungs. This study's specific attention was focused on the effect of membrane vibration in the LAD. Quantitative experimental measurements were performed to evaluate the performance of the device, and to identify membrane vibration dependence on blood hemolysis. We tried to decide upon excited frequency band of limit hemolysis when blood hemolysis came to through a membrane vibration action. The excited frequency of the module type 5, consisted of 675 hollow fiber membranes, showed the maximum gas transfer rate. We concluded that the maximum oxygen transfer rate seemed to be caused by the occurrence of maximum amplitude and the transfer of vibration to hollow fiber membranes. It was excited up to $25{\pm}5$ Hz at each blood flow rate of module type 5. We found that this frequency became the 2nd mode resonance riequency of the flexible in blood flow. Blood hemolysis was low at the excited frequency of $25{\pm}5$ Hz. Therefore, we decided that limit hemolysis frequency of this LAD was $25{\pm}5$ Hz.

Ventilatory Responses to Continuous Negative Pressure Breathing(CNPB) in Awake Dogs

  • Cha, Eun-Jong;Goo, Yong-Sook
    • The Korean Journal of Physiology
    • /
    • v.27 no.1
    • /
    • pp.37-49
    • /
    • 1993
  • Ventilatory responses to inhaled $CO_2$ were measured during continuous negative pressure breathing (CNPB) in awake dogs. End expiratory lung volume (EELV) decreased linearly with pressure level during CNPB (correlation coefficient= 0.81, p<0.005) during air breathing. When CNPB was applied during 5% $CO_2$ inhalation, the decrease in EELV was not significantly different (p<0.5) from that during air breathing. As a result of a lowered EELV, tidal volume ($V_T$) significantly decreased by 22% and breathing frequency ($f_B$) increased by 68% in the steady state during air breathing (p<0.0001). These responses were similar during 5% $CO_2$ inhalation, thus the $CO_2$ response curve measured during CNPB shifted upward without a change in sensitivity (p>0.05). These results indicate additive effects of CNPB and $CO_2$ inhalation. The degree of hyperventilation during CNPB at eupnea was estimated to be 63% of that during control ventilation and was significantly greater than zero (p<0.0001), which suggests an alveolar hyperventilation due to CNPB. These results suggest that the mechanical alterations associated with n decrease in lung volume could play an important role in ventilatory control independently of chemical regulation of breathing. Thus, exercise hyperpnea, which is associated with a lowered functional residual capacity (FRC), may in part be explained by this mechanical stimulation of breathing.

  • PDF

Overlap Syndrome:Obstructive Sleep Apnea-Hypopnea Syndrome in Patients with Chronic Obstructive Pulmonary Disease (중첩증후군:만성 폐쇄성 폐질환을 가 진 폐쇄성 수면무호흡-저호흡 증후군)

  • Choi, Young-Mi
    • Sleep Medicine and Psychophysiology
    • /
    • v.15 no.2
    • /
    • pp.67-70
    • /
    • 2008
  • Overlap syndrome can be defined as a coexistence of chronic obstructive pulmonary disease (COPD) and sleep apnea-hypopnea syndrome (SAHS). The association of COPD and SAHS has been suspected because of the frequency of both diseases. Prevalence of COPD and SAHS is respectively 10 and 5% of the adult population over 40 years of age. However, a recent study has shown that the prevalence of SAHS is not higher in COPD than in the general population. The coexistence of the two diseases is only due to chance. SAHS does not affect the pathophysiology of COPD and vice versa. Prevalence of overlap syndrome is expected to occur in about 0.5% of the adult population over 40 years of age. Patients with overlap syndrome have a more profound hypoxemia, hypercapnia, and pulmonary hypertension when compared with patients with SAHS alone or usual COPD patients without SAHS. To treat the overlap syndrome, nocturnal noninvasive ventilation (NIV) or nasal continuous positive airway pressure (nCPAP) can be applied with or without nocturnal oxygen supplement.

  • PDF

Affecting Factors of Upper Extremity Work-Related Musculoskeletal Disorder Among the Directory Assistance Operator (전화번호안내원의 단순반복작업에 의한 상지의 작업관련성 근골격계장애 영향 요인)

  • Kim, Young-Min
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.13 no.2
    • /
    • pp.85-95
    • /
    • 2007
  • Purpose: The purpose of this study was to investigate the prevalence and affecting factors of work-related musculoskeletal disorder (WRMSD) among the directory assistance operators. Methods: One hundred eighty-five female subjects who worked more than one year as directory assistance operators in a telecommunication company were surveyed with self-administered questionnaires. Subjects were divided into disorder and control group by the NIOSH criterion about WRMSD, and then analyzed. Results: One hundred seventy two subjects (93%) had upper extremity symptoms and seventy subjects (37.8%) were WRMSD. the frequency order of the disorder area was the shoulder 60(32.4%), the neck 37(20.0%), the wrist 20(10.8%), the finger 20(10.8%) and the elbow 5(2.7%). It was found that the difference factors of the WRMSD group were education level (p<0.01), stress from the customers (p<0.01), satisfaction about monitor (p<0.05), temperature (p<0.05), noise (p<0.01), ventilation (p<0.001), working time (p<0.05), and recess (p<0.001). Conclusion: Improving working condition and education for the workers to control the stress are necessary to decrease the WRMSD for the directory assistance operators.

  • PDF

PWAM Based THD Reduction of Inverter for Air-Conditioning Blower (PWAM 방식을 이용한 공조시스템용 인버터의 THD 저감 방법)

  • Lim, Seung-Beom;Lee, Yun-Ha;Zun, Chan-Yong
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.97-98
    • /
    • 2011
  • The HVAC(Heating Ventilation and Air conditioning) system is controlled by two ways, one is ON/OFF control and the other is PWM inverter with V/F. Control of blower with the use of PWM inverter has quite some benefits such as the capability of changing speed, high efficiency and reduced noise level compared with ON/OFF control. But if blower is operated at low speed, high THD generated by decrease of ma, and output voltage lowered in proportion to frequency. To solve these problems, filter should be installed at the output stage of inverter, which can decrease THD but has problems such as increase of volume size and additional braking resistance. This paper proposes the PWAM method which can reduce THD instead of installing the filter at the output stage of inverter. The proposed PWAM method is an inverter modulation method that fixes the modulation index of inverter to reduce THD by varying DC link voltage of inverter unlike conventional PWM method. Finally, the validity of proposed PWAM methods verified by experiments.

  • PDF

High Frequency Ventilation (고빈도 환기법)

  • Lee, Hyeon-U;Lee, Gwan-Ho
    • Journal of Yeungnam Medical Science
    • /
    • v.10 no.1
    • /
    • pp.1-17
    • /
    • 1993
  • 고빈도 환기법은 최근에 개발되어 임상에 응용되면서 호흡생리학, 마취학, 집중치료의 학등의 분야에서 호흡부전의 새로운 치료법으로 관심이 집중되고 있는 환기법이다. 현재까지 고빈도 환기법중 고빈도 양압 환기와 제트 환기는 비교적 많은 연구가 되고 있고 임상적으로 사용되고 있으나 고빈도 진동 환기법은 제한적으로 사용되고 있다. 앞으로 고빈도 진동 환기법에 대해서도 더 많은 연구가 되어야 할 것이다. 또한 최근 개발되고 있는 고빈도 흉벽 진동 환기와 체표면 진동 환기에도 관심을 기울이면 호흡부전 환자의 치료에 바람직한 새로운 환기법이 될 수 있을 것으로 기대된다. 현재 고빈도 환기법의 몇몇 적용형태는 기관지-늑막루등의 폐압손상으로 인한 병변의 치료외에도 기관수술, 흉부수술, 뇌수술에서 수술부위의 움직임을 최소화시키면서 충분한 가스교환율 이룩할 수 있어서 효과적으로 이용되고 있다. 그러나 응급심폐소생술, 폐쇄성 폐질환, 성인 또는 영아 호흡곤란증후군등과 같은 질환에서의 적용은 더 규명되어져야겠다. 고빈도 환기법의 여러가지 문제점중 적절한 환기빈도의 결정, 충분한 습도를 공급하는 장치, 고빈도 환기의 정확한 감시장치의 개발등은 앞으로 우선적으로 해결해야 할 문제점이다. 또한 임상에 더욱 효과적으로 응용될 수 있는 새로운 환기법이 되기 위해서는 고빈도 환기법의 호흡생리와 안정성등에 관한 연구도 병행되어야겠다.

  • PDF