• Title/Summary/Keyword: Ventilation frequency

Search Result 143, Processing Time 0.031 seconds

Pulmonary and Cutaneous Evaporative Water Losses in Sahiwal and Sahiwal × Holstein Cattle During Solar Exposure

  • Aggarwal, Anjuli;Upadhyay, R.C.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.10 no.3
    • /
    • pp.318-323
    • /
    • 1997
  • In order to assess the effect of solar exposure on pulmonary functions and evaporative losses from skin and pulmonary surfaces, in six healthy Sahiwal (S) and six Sahiwal ${\times}$ Holstein ($S{\times}H$) cattle were exposed to direct sun during summer. Breed differences were observed during exposure. Increase in sweating rate was higher in crossbreds (222%) than in Sahiwal (125%). Pre-exposure (ambient temperature, $32.6{\pm}0.85^\circ}C$, solar radiation, $0.9cal\;cm^{-2}min^{-1}$) evaporative loss from skin accounted for about 90% of the losses and remaining losses were contributed by pulmonary surfaces in Sahiwal. The contribution of evaporation through skin increased to 92% (ambient temperature $39.4{\pm}0.68^\circ}C$, solar radiation, $1.35cal\;cm^{-2}min^{-1}$). In crossbreds 80% of the evaporative losses were through skin before exposure which increased to 87% after exposure to solar radiations. Rectal temperature increase was higher in crossbreds ($1.5^{\circ}C$) than in Sahiwal ($0.8^{\circ}C$). With the increase in pulmonary evaporative losses, respiratory frequency increased to 2 fold in Sahiwal and pulmonary ventilation increased 1.6 times the resting value in Sahiwal due to solar exposure. In $S{\times}H$ crossbreds the respiratory frequency increased 3.5 times and pulmonary ventilation increased only to 1.8 times due to decrease in tidal volume. There was about 2 fold increase in alveolar ventilation in both the breeds, the increase in dead space ventilation was more in crossbreds than in Sahiwal. Behavioral symptoms exhibited by animals after exposure were profuse salivation, open mouth panting, tongue protrusion and general restlessness.

Analysis of Adult Cardiopulmonary Resuscitation Skill Performed by Emergency Medical Technicians in Fire Department (소방 2급응급구조사의 성인 심폐소생술에 대한 숙련도 분석)

  • 최용철;이창섭;왕순주
    • Fire Science and Engineering
    • /
    • v.18 no.1
    • /
    • pp.13-17
    • /
    • 2004
  • Purpose: The purpose of this study is to predict a reasonable direction to design a pertinent educational program in the future by evaluating an adult CPR(Cardiopulmonary Resuscitation) skill performed by EMTs engaged in fire services organization and comparing the CPR success rate of factors as like a duty place and licensed year. Methods: We studied CPR skill by the use of a CPR manikin(Skillmeter Resusci Annie, Laerdal company). The study population consisted of 320 EMTs. Every EMT performed four cycle after investigating the manikin for 2 minutes. We regarded chest compression with 100 times in a minute as the 100% success rate. We analysed the skill of chest compression, ventilation and chest compression times success rate by the records printed in the CPR paper. Results: The average success rate of chest compression was 59.42$\pm$29.26% and ventilation 49.22$\pm$29.65%. The success rate of manual CPR was different between chest compression and ventilation. Also the success rate of chest compression times was high relatively as a 87.32$\pm$9.14%(p=0.000). For the CPR skill, ventilation was lowest as 49.22%. The factors such as duty place and licensed year did not influence the CPR success rate (p>0.001). Conclusion: We could have conclusion that CPR training should be shared more time in ventilation than in chest compression. Also we could reach to a conclusion that it is important to increase the times of CPR training for improving the accuracy of CPR and that the continuing education of CPR training frequency might be more than four times in a year.

Increase In Mean Alveolar Pressure Due To Asymmetric Airway Geometry During High Frequency Ventilation

  • Cha, Eun-J.;Lee, Tae-S.;Goo, Yong-S.;Song, Young-J.
    • Journal of Biomedical Engineering Research
    • /
    • v.14 no.1
    • /
    • pp.89-96
    • /
    • 1993
  • During high frequency ventilation (HFV), mean alveolar pressure has been measured to increase with mean airway opening pressure controlled at a constant level in both humans and experimental animals. Since this phenomenon could potentiate barotrauma limiting advantages of HFV, the present study theoretically predicted the difference between menu alveolar and airway opening pressures ($MP_{alv}$). In a Weibel's trumpet airway model, approximated formula for $MP_{alv}$ was derived based on momentum conservation assuming a uniform velocity profile. The prediction, equation was a func pion of gas density($\rho$), mean flow rate(Q), and diameter of the airway opening where the pressure measurement was made($D_0$) : $MP_{alv}=4{\rho}(Q/D_0^{2})^2$. This was a result of the difference in crosssectional area between the alveoli and the airway opening. A simple aireway model experiment was performed and the results well fitted to the prediction, which demonstrated the validity of the present analysis. Previously reported $MP_{alv}$ data from anesthetized dogs in supine position were comparable to the predicted values, indicating that the observed dissociation between mean alveolar and airway opening pressures during HFV can be explained by this innate geometric (or cross-sectional area) asymmetry of the airways. In lateral position, however, the prediction substantially underestimated the measurements suggesting involvement of other important physiological mechanisms.

  • PDF

A Study on the Effect which the Method of Deep Breathing with the Use of Incentive Spirometer has on the function of pulmonary Ventilation - In Upper Abdominal Operation Patients - (Incentive Spirometer를 사용한 심호흡 방법이 폐환기 기능에 미치는 효과에 관한 연구 -상복부 수술 환자를 대상으로-)

  • 김종혜;변영순
    • Journal of Korean Academy of Nursing
    • /
    • v.21 no.3
    • /
    • pp.268-280
    • /
    • 1991
  • The nursing intervention for the prevention of the pulmonary complication and of the function lowering of pulmonary ventilation which emerge with high generation frequency during the nursing of operation patient is necessary for performing the qualitative nursing for operation patient. So, this researcher tried this study so as to obtain the data which can be utilized for the trial of nursing intervention, by grasping the effect that the deep breathing with Incentive Spirometer has on the function of pulmonary ventilation, analysing the factor to have influence on the function of pulmonary ventilation, and applying the effective method of deep breathing to the clinic. By making 42 patients who underwent the operation of upper abdomen after admitting G Hospital in Seoul from Mar. 7, 1991 to Apr.30, 1991 as the object, they were classified into the experiment group that the deep breathing was made with the use of Incentive Spiromenter and the comparison group that the deep breathing exercise was made without the use of Incentive Spirometer. And then, by measuring Tidal Volume and Forced Vital Capacity with Respirometer and $O_2$ Saturation with Pulse Oximeter at preoperation postoperation 24 hours, 72 hours, and 120 hours data were collected. The collected data were analyzed with of, average, standard deviation, x$^2$-test, t-test and ANOVA by SPSS. The result of this study is as follows : 1. As for the hypothesis that the function of pulmonary ventilation at postoperation 24 hours, 72 hours and 120 hours will be better in the experiment group that the deep breathing was made with the use of Incentive Spirometer, in comparison with the comparison group that deep breathing was made without the use of Incentive Spirometer, experiment group and comparison group didn't show the significant difference in Tidal Volume, Foreced Vital Capacity and $O_2$ Saturation at postoperation 24 hours and 72 hours. But experiment group and comparison group showed the significant difference in Tidal Volume at postoperation 120 hours (p<0.01). So, this hypothesis was supported partially. 2. The variables that there were the significant differences about the function of pulmonary ventilation in experiment group at postoperation 24 hours stastically were smoking existence (p<0.05), and the variables that there were not significant differences about the function of pulmonary ventilation were distinction of sex, age, anesthetic duration, smoking extent, body weight, surface area of body, existence of narcotic use, regular exercise existence, and past experience existence of respiratory disease. As above result, it appeared that the method of deep breathing with the use of the Incentive Spirometer is more effective for the function recovery of pulmonary ventilation, in comparison with the deep breathing without use of Incentive Spirometer and that smoking existence was the factor to have influence on the function of pulmonary ventilation. In the aspect of clinic, the trial of nursing intervention of deep breathing with use of Incentive Spirometer is expected. And, in the aspect of study, the study through various operative site patients about the effect of Incentive Spirometer use at the clinic will have to be confirmed.

  • PDF

Energy cost of loads carried on the hands, head, or feet (짐나르기의 에너지 소요량)

  • Hwang, Dai-Yun;Nam, Kee-Yong
    • The Korean Journal of Physiology
    • /
    • v.5 no.2
    • /
    • pp.29-40
    • /
    • 1971
  • Oxygen consumption, pulmonary ventilation, heart rate, and breathing frequency were measured on 8 men walking on a treadmill carrying load of 9 kg on hand, back, or head. Besides measurements were made on subjects carrying loads of 2.6 kg each on both feet. The speed of level walking was 4, 5, and 5.5km/hr and a fixed speed off km/hr with grades of 0, 3, 6, and 9%. Comparisons were made between free walking without load and walking with various types of loads. The following results were obtained. 1. In level or uphill walking the changes in oxygen consumption, pulmonary ventilation, breathing frequency and heart rate were smallest in back load walking, and largest in hand load walking. The method of back load was most efficient and hand load was the least efficient. The energy cost in head load walking was smaller than that of in hand load walking. It was assumed that foot load costed more energy than hand load. 2. In level walking the measured parameters increased abruptly at the speed of 5.5 km/hr. Oxygen consumption in a free walking at 4 km/hr was 11.4ml/kg b.wt., and 13.1 ml/kg b.wt. 5.5 km/hr, and in a hand load walking at 4 km/hr was 13.9, and 18.8 ml/kg b. wt. at 5.5 km/hr. 3. In uphill walking oxygen consumption and other parameters increased abruptly at the grade of 6%. Oxygen consumption at 4 km/hr and 0% grade was 11.4 ml/kg b. wt., 13.6 at 6% grade, and 16.21/kg b. wt. at 9% grade in a free walking. In back load walking oxygen consumption at 4km/hr and 0% grade was 12.3 ml/kg b.wt.,14.9 at 6% grade, and 18.7 ml/kg b.wt. In hand load walking the oxygen consumption was the greatest, namely, 13.9 at 0% grade, 17.9 at 6%, and 20.0 ml/kg b. wt. at 9% grade. 4. Both in level and uphill walking the changes in pulmonary ventilation and heart rate paralleled with oxygen consumption. 5. The changes in heart rate and breathing frequency in hand load were characteristic. Both in level and uphill walk breathing frequency increased to 30 per minute when a load was held on hand and showed a small increase as the exercise became severe. In the other method of load carrying the Peak value of breathing frequency was less than 30 Per minute. Heart rate showed 106 beats/minute even at a speed of 4 km/hr when a load was held on hand, whereas, heart rate was between, 53 and 100 beats/minute in the other types of load carriage. 6. Number of strides per minute in level walking increased as the speed increased. At the speed floater than 5 km/hr number of strides per minute of load carrying walk was greater than that of free walking. In uphill walk number of strides per minute decreased as the grade increased. Number of strides in hand load walk was greatest and back load walk showed the same number of strides as the free walk.

  • PDF

Comparison of Related Characteristics between Unplanned and Planned Extubation of Patients in Medical Intensive Unit (내과계 중환자의 비계획적 기관내관 발관과 계획적 기관내관 발관의 관련 특성 비교)

  • Cho, Hyo Im;Lee, Young Whee;Kim, Hwa Soon;Sim, Bo-Yun
    • Korean Journal of Adult Nursing
    • /
    • v.24 no.5
    • /
    • pp.509-519
    • /
    • 2012
  • Purpose: This retrospective study was designed to examine the frequency of unplanned extubation, and to identify the related factors of unplanned extubation in medical intensive care unit patients. Methods: Data were collected from medical records of patients who received intubation in a medical intensive care unit. One hundred eighteen patient charts were selected for the study. The Patient Severity Classification Scale and unplanned extubation risk factors were examined. Data were analyzed with descriptive statistics, $x^2$-test, Fisher's exact test and Mann-Whitney U test. Results: The incidence of unplanned extubation was 11 (9.32%) out of 118 patients who had undergone intubation. There were statistically significant differences between the unplanned extubation and work shift ($x^2$=61.52, p=.001), ventilation mode (p=.001), number of days of ventilator application (U=366.00, p=.038) and administration of sedatives (p=.025). Conclusion: Unplanned extubation is affected by the following variables: a) whether a nurse is in night shift, b) whether ventilation is mandatory, c) duration of ventilation use and d) administration of sedatives.

A Subjective Symptom Level and Satisfaction Factor by Indoor Air Quality According to Ventilation System in Dental Clinic (치과병·의원 환기방법에 따른 실내공기질 자각증상 수준 및 근무환경 만족요인)

  • Choi, Mi-Suk;Ji, Dong-Ha;Choi, Jae-Ho
    • Journal of dental hygiene science
    • /
    • v.11 no.4
    • /
    • pp.353-359
    • /
    • 2011
  • This study was designed to identify a subjective symptom level by Indoor air according to ventilation system in Dental Clinic. The number of respondents was 582 who work in dental clinic and period of investigation was October 2010 through January 2011. A structured questionnaire was employed to evaluate the level of participants' sociodemographics, job-related factors, work place condition, a subjective symptom. Most of respondents were answered that time for symptom to begin was at around 2 P.M. and time for symptom to feel serve pain was at around 3 P.M. and ventilation frequency per a day was often in case of individual cooling and heating system. More often natural ventilation and in case of individual cooling and heating system, the level of subject symptom was low and multiple regression analysis has found that indoor air quality related elements were main factors that influence to the feeling of satisfaction in work place. The results of this study suggest that more often natural ventilation was very important to reduce the level of subjective symptom. Thus, a management program for indoor air quality is strongly recommended by natural ventilation, maintenance man for promotion of quality of life in dental hygienist and to improve dental service and competitiveness.

Evaluation of a Fungal Spore Transportation in a Building under Uncertainty

  • Moon, Hyeun Jun
    • Architectural research
    • /
    • v.8 no.1
    • /
    • pp.37-45
    • /
    • 2006
  • A fungal spore transportation model that accounts for the concentration of airborne indoor spores and the amount of spores deposited on interior surfaces has been developed by extending the current aerosol model. This model is intended to be used for a building with a mechanical ventilation system, and considers HVAC filter efficiency and ventilation rate. The model also includes a surface-cleaning efficiency and frequency that removes a portion of spores deposited on surfaces. The developed model predicts indoor fungal spore concentration and provides an indoor/outdoor ratio that may increase or decrease mold growth risks in real, in-use building cases. To get a more useful outcome from the model simulation, an uncertainty analysis has been conducted in a real building case. By including uncertainties associated with the parameters in the spore transportation model, the simulation results provide probable ranges of indoor concentration and indoor/outdoor ratio. This paper describes the uncertainty quantification of each parameter that is specific to fungal spores, and uncertainty propagation using an appropriate statistical technique. The outcome of the uncertainty analysis showed an agreement with the results from the field measurement with air sampling in a real building.

A Study on the Fan and Scroll for Ventilation (배기용 Fan Scroll에 대한 연구)

  • Song, S.B.;Park, S.I.;Lee, J.S.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.402-406
    • /
    • 2000
  • In the Over-The-Range, the outlet size is limited by the industrial standards. Therefor to enlarge the volume of cavity, the installation height of ventilation fan is become small, the system resistance is higher than before. For that reason, the important design variables such as the diameter of a fan, the scroll expansion angle, etc. which play the significant role on flow rate and noise, are confined. In this study, we made an experiment of the diameter of fans relation to scroll expansion angle and investigated flow rate of the length of fans in enlarged cavity volume of OTR, and then we designed the new scroll to improve the flow rate and noise level. As a result, flow rate increased to 110% compared to current scroll and the blade passing frequency of a fan is disappeared by inclined cut-off shapes.

  • PDF