• 제목/요약/키워드: Ventilation frequency

검색결과 143건 처리시간 0.021초

The Characteristic of a Functional Design for a Commercial Outdoor-Wear Jacket (국내 아웃도어 브랜드 등산복 재킷의 기능별 디자인 특성)

  • Lee, Young-Wha;Seo, Moon-Jung;Seo, In-Kyung;Kim, Young-In
    • Journal of the Korean Society of Costume
    • /
    • 제63권7호
    • /
    • pp.1-16
    • /
    • 2013
  • The objective of this study is to analyze the characteristic of a functional design for a commercial outdoor brand jacket based on 3 types of functions : windproof, waterproof, and cold proof. To analyze the design and fabric characteristics of outdoor jackets by function, 903 men's and women's outdoor jacket images were selected from the catalogues during S/S 2009 - F/W 2011 of the 6 brands: The North Face, Columbia Sports Wear, Kolon Sports, K2, Arcteryx and Mont-Bell. These brands were selected based on their high market share and brand awareness of the outdoor brands in Korea. In this study, design elements analysis was conducted as following 8 elements: hood/collar height/central front flap/waistline/pocket location/ventilation for the body part/sleeve patterns/cuff for the sleeve part. Fabrics were analyzed by the frequency of fabric types used in the 3 jacket types. According to the result derived from the analysis of the six brands of outdoor wear jacket design trends by year, detachable hood and a co-use of velcro and elastic bands have been mainly designed for all of windproof, waterproof, and cold proof jacket to all in order to respond quickly to changes in the external environment. For reinforced storage function on trekking, the number of pockets has been gradually growing, and a function was being developed to connect an electronic device to a pocket. The method, result, and collateral observations relevant to each of these phases are described. Outdoor jacket design characteristics were investigated for outdoor brands, which can provide data to suggest more accurate functional design, and satisfy functional design needs. In this regard, this research was significant in the sense that it suggested preliminary data to reconsider competitiveness of the brand products.

Development of the Sentiment Indicators of Housing Welfare (주거복지지표 개발에 관한 연구 II - 수요자 측면의 주거복지체감지표와 지수를 중심으로 -)

  • Jee, Eun-Young;Eun, Nan-Soon;Hong, Hyung-Ock
    • Journal of the Korean housing association
    • /
    • 제19권5호
    • /
    • pp.85-92
    • /
    • 2008
  • The aim of this research is to develop the sentiment indicators of housing welfare for evaluating housing welfare policies conducted by the Korean government. The methods of this research are used by analysis of related documents, FGI (Focus Group Interview), and survey. The survey was made by experts and consumers. To analyze the survey, this research also uses confirmatory factor analysis by SPSS (Statistical Package for the Social Science) program, AHP (Analytical Hierarchy Process) by Expert Choice program, frequency, average, percentages, Factor analysis etc. As a result of this research, selected housing welfare indicators are settled as follows: In the housing welfare aspect, 11 indicators in the department of 'Housing Satisfaction' and 11 indicators in the department of 'Community Satisfaction' (22 in total) are suggested. The indicators are 1) Water Supply and Distribution Equipment 2) Heating equipment 3) the size of the exclusive residential area 4) the number of rooms 5) Ventilation and Lighting 6) Sound Insulation (Indoor Noise) 7) Air Pollution/Odor 8) House Deposit 9) Rent Paid 10) Maintenance (Dwelling) Cost 11) The length of Occupation 12) Proximity to Welfare Facilities 13) Educational Environment 14) Convenience of Facilities (shops, hospitals etc.) 15) Convenience of Transportation and Commuting 16) Distance from Workplace 17) Landscape and Green Space (Tree, Flowers, Grass etc.) 18) Vandalism (Destruction Behavior, graffiti etc.) 19) Privacy 20) Noise in Public Places (Drinking, Loudly Talking etc.) 21) Safety from Crime 22) Safety from a Disaster. As of 2007, the housing welfare sentiment index is measured by the survey of 1,000 inhabitants in the public housing, which shows 3.51.

The effect of a risk factor on quantitative risk assessment in railway tunnel (철도터널에서 위험인자가 정량적 위험도 평가에 미치는 영향)

  • Yoo, Ji-Oh;Kim, Jin-Su;Rie, Dong-Ho;Shin, Hyun-Jun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • 제17권2호
    • /
    • pp.117-125
    • /
    • 2015
  • Quantitative risk assessment (QRA) of railway is to create a variety of scenario and to quantify the degree of risk by a result of the product of accident frequency and accident. Quantitative risk Assessment is affected by various factors such as tunnel specifications, characteristics of the fire, and relation of smoke control and evacuation direction. So in this study, it is conducted that how the way of smoke control and the relation of smoke control and evacuation direction affect quantitative risk assessment with variables (the tunnel length (2, 3, 4, 5, 6 km) and the slope (5, 15, 25‰)). As the result, in a train fire at the double track tunnel (Area = $97m^2$), it is most efficient to evacuate to the opposite direction of smoke control regardless of the location of train in train fire. In addition, under the same condition, index risk in mechanical ventilation up to 1/10.

The Influences of Immune Function and Respiratory System on Aerobic Exercise by Exposed Acute Hypobaric Hypoxic Environment. (급성 저압.저산소 노출에서의 유산소성 운동이 면역기능 및 호흡기계에 미치는 영향)

  • Lee, Dong-Jun
    • Journal of Life Science
    • /
    • 제19권6호
    • /
    • pp.825-831
    • /
    • 2009
  • The purpose of this study was to investigate the influences of immune function and respiratory system on aerobic exercise of 75 %HRmax intensity in an exposed acute hypobaric hypoxic environment. The subjects were 20 male college students, 10 of which were soccer players (19.6${\pm}$0.8 yr, BMI 22.3${\pm}$1.0, V02max 56.5${\pm}$4.8 mljkgjmin) and 10 general students (22.2${\pm}$2.3 yr, BMI 22.7${\pm}$2.1, $VO_{2max}$ 50.5${\pm}$6.6 ml/kg/min). Items of measurement after exercise on level and high altitude were $O_{2}$, $CO_{2}$, ventilation (VE), respiratory frequency, respiratory quotient, RBC, MCV, MCH, MCHC, Hb, Hct, reticulocyte, WBC, neutrophil, lymphocyte, monocyte, basophil, and immunoglobulin (IgA, IgD, IgG, IgM). As the result of the verifying hypothesis, these results may suggest three new findings: first, to produce hypoxic ventilatory depression not only at level land but also at 3,000 m high altitude during 30 minute aerobics exercise of 75 %HRmax intensity, second to be more excellent for soccer players in adaptation and sensibility on response of respiratory system at high altitude, and third, to change each other by regular exercise habits or altitude in the monocyte.

Experimental Study of the Influence of the Upper Airway Obstruction on the Blood Gas Analysis (인위적인 기도협착이 동맥혈액가스에 미치는 영향)

  • 정해영;김중환;조영상
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 대한기관식도과학회 1979년도 제13차 학술대회 연제순서 및 초록
    • /
    • pp.8.2-8
    • /
    • 1979
  • Acute obstruction of the upper airway from trachea, a foreign body or Iaryngospasm may lead to death in a few minutes. The immediate restoration of an adequate airway in these patients may be lifesaving. Spontaneous respiration by means of a needle inserted into the trachea was studied in 21 rabbits using 16, 18, and 20 gauge extrcatheters. The results are as follows; 1) Airway resistance was markedly increased in all experimental animals. consequently tidal volume was also significantly decreased, but this seems to be compensatory by increased of respiratory frequency in l6G group. 2) Blood gas analysis revealed adequate pulmonary ventilation through the constricted airway (about 1/3 of normal sized trachea) during 60 minutes. In the other hand, hypercarbia, hypoxemia, and metabolic acidosis were developed in the group with severe constriction of the upper airway (about 1/4-1/6 of normal sized trachea). 3) The further study is postulated to confirm the the possibility of application of needle trcheostomy in man, but the rabbits were tolerable to the constricted airway with a small sized needle (l6G) into the trachea for 60 minutes.

  • PDF

Cardiorespiratory Responses of Qi-training: A Pilot Study

  • Lee, Myeong-Soo;Kim, Soo-Keun;Kim, Hye-Jung;Moon, Sun-Rock
    • Advances in Traditional Medicine
    • /
    • 제4권1호
    • /
    • pp.18-21
    • /
    • 2004
  • Six volunteers (mean $age=25.7{\pm}1.7$, $height=173{\pm}1.9$ and $weight=63.4{\pm}2.3{\;}kg$) participated in a graded exercise test and one hour of basic form of ChunDoSunBup (CDSB) Qi-training to investigate the cardiorespiratory responses and exercise intensity of Qi-training, a Korean traditional psychosomatic training. In the maximal exercise, the trainee showed $96.2{\pm}8.89{\;}l/min$ in ventilation (VE), $46.0{\pm}4.4$ in breath frequency (BF), $1.31{\pm}0.05$ in respiratory exchange ratio (RER), $180.7{\pm}3.0$ in heart rate (HR), and $2.6{\pm}1.1{\;}l/min$ or $40.7{\pm}2.3{\;}ml/kg/ml$ in oxygen consumption $(VO_2)$. Qi-training induced significant changes in BF, RER, HR, and $VO_2$. The exercise intensity of Qi-training were 42.3%, 46.9% and 38.7% of $HR_{max}$ during the sound exercise, slow motion (haeng-gong) and meditation respectively and the average was 46.2% of $HR_{max}$. We conclude that Qi-training is an aerobic exercise of a light (mild) intensity exercise, and it leads to decrease the metabolic rate in the trainee by breathing efficiently and relaxing them. In addition, Qi-training may affect cardiorespiratory function of BF, RER, HR and $VO_{2max}$ in trainees.

A study on the Characteristics of a Centrifugal Fan Vibration and Noise (Centrifugal Fan 송풍기의 진동.소음 특성에 관한 연구)

  • 김태형;김옥현
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • 제16권5호
    • /
    • pp.999-1003
    • /
    • 1992
  • Because of low noise and small size with huge capacity, a centrifugal fan is widely used for ventilation, air-conditioner and so on, which are very near to human life. Because of the complexity of its vibration and noise generation mechanics, most of researches on them are based on experimental methods. This study is to characterize the centrifugal fan noise and vibration. It is considered that noise is composed of the structural vibration noise and the air flow induced aerodynamic noise. To decouple the structural vibration noise the centrifugal fan is masked with an adhesive tape, such that air blowing is prohibited thus only the structural vibration noise is extracted. The noise level and characteristics in the frequency domain are verified and compared with those of total mixed one. This study shows some significant results that the structural vibration noise has relatively narrow band power spectrum compared with the total mixed one and has a strong periodicity. The sound level is lowered about 5dB by the removal of air flow with the masked fan for an air-conditioner used in this study.

Risk Assessment of 30 MeV Cyclotron Facilities (30 MeV 사이클로트론 시설 위험성 평가)

  • Jeong, Gyo-Seong;Kim, Chong-Yeal;Lee, Jin-Woo
    • Journal of Radiation Industry
    • /
    • 제11권1호
    • /
    • pp.39-45
    • /
    • 2017
  • A cyclotron is a kind of particle accelerator that produces a beam of charged particles for the production of medical, industrial, and research radioisotopes. More than 30 cyclotrons are operated in Korea to produce $^{18}F$, an FDG synthesis at hospitals. A 30-MeV cyclotron was installed at ARTI (Advanced Radiation Technology Institute, KAERI) mainly for research regarding isotope production. In this study, we analyze and estimate the items of risk such as the problems in the main components of the cyclotron, the loss of radioactive materials, the leakage of coolant, and the malfunction of utilities, fires and earthquakes. To estimate the occurrence frequency in an accident risk assessment, five levels, i.e., Almost certain, Likely, Possible, Unlikely, and Rare, are applied. The accident consequence level is classified under four grades based on the annual permissible dose for radiation workers and the public in the nuclear safety law. The analysis of the accident effect is focused on the radioactive contamination caused by radioisotope leakage and radioactive material leakage of a ventilation filter due to a fire. To analyze the risks, Occupation Safety and Health Acts is applied. In addition, action plans against an accident were prepared after a deep discussion among relevant researchers. In this acts, we will search for hazard and introduce the risk assessment for the research 30-MeV cyclotron facilities of ARTI.

The Changes of External Ear Resonance after Surgery for Repair of the Postauricular Meato-Mastoid Cutaneous Fistula (외이도-유양동-귀뒤바퀴피부 누공환자에서 수술 전, 후의 외이도 공명의 변화)

  • Kim, Sangjun;Kang, Myung Koo;Jeong, Sung Wook;Lee, Dong Kun
    • Journal of Clinical Otolaryngology Head and Neck Surgery
    • /
    • 제29권2호
    • /
    • pp.235-239
    • /
    • 2018
  • Due to the structure with one end closed, the external ear resonance effect in which the high frequency is amplified can be generated, and the sound can be perceived well. The external ear resonance normally has a first peak and a second peak. On average, the first peak has a gain of 18.6 dB at 2620 Hz and the second peak has a gain of 18.2 dB at 4210 Hz. The resonance of the external auditory canal changes with the state of the tympanic membrane, the presence of the ventilation tube, and the structure (length, diameter, shape) of the external auditory canal. A patient with a postauricular meatomastoid cutaneous fistula was admitted to the hospital with a foreign body which is the molding of the hearing aid. After removal of the foreign body, the resonance of the external auditory canal was lost and the subjective sound cognitive ability decreased. In the case of postauricular meatomastoid cutaneous fistula, we confirmed the improvement of sound cognitive ability, the change of pure tone hearing threshold, and the change of the external ear resonance after reconstruction of the ear canal without middle ear reconstruction.

A Study on Three-Dimensional Flow Analysis and Noise Source of Sirocco Fan (시로코 팬의 3차원 유동해석 및 소음원에 관한 연구)

  • Kang, Jeong-Seok;Kim, Jin-Taek;Lee, Cheol-Hyung;Baek, Byung-Joon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제19권12호
    • /
    • pp.896-902
    • /
    • 2018
  • This study examined the flow and noise inside a sirocco fan for ventilation as a commercial program. To confirm only the location and power of the noise source, flow analysis was performed with steady state flow analysis. Through flow analysis, the flow was observed in the sirocco fan and the velocity vector. The pressure distribution inside was observed with contours. From the results of steady analysis, the position and size of the noise source could be seen using the 'Curle surface acoustic power' and 'Proudman acoustic power'. The Curle surface acoustic power can be used to observe the noise from the surface. The Proudman acoustic power can be used to detect noise generated in the flow region because the position and size of the noise source generated inside the sirocco fan can be seen only in the steady state. Therefore it is necessary to further analyze the unsteady state to check the frequency of the noise generated. This study provides basic data for improving the performance of the Sirocco fan and reducing the noise.