The effects of introduction of diesel passenger cars on the ventilation requirements for road tunnels (경유승용차 도입이 터널 소요환기량에 미치는 영향분석)

  • Kim, Hyo-Gyu;Song, Seok-Hun;Kim, Nam-Young;Lee, Chang-Woo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.9 no.3
    • /
    • pp.309-321
    • /
    • 2007
  • Since the first diesel passenger car hit the local road in late 2005, the share of diesel cars is growing significantly; possibly up to the level as in the western Europe. In this study, the effects of introduction of diesel passenger cars on the ventilation rate and facility capacity are analyzed for the three individual cases with different basic exhaust rate based on the vehicle age, the vehicle class percentage and the smoke exhaust rate. The target tunnel for this comparative study is a typical 2 km-long 2-lane highway tunnel. Case 1 assuming the current local design standards and the diesel vehicles comprising 40% of the total passenger cars on the road required more ventilation rate and facility capacity than in the case only with the current standards. Case 2 which is the real tunnel currently in the designing stage taking into account the vehicle age but ignoring the diesel vehicle ratio, and Case 3 on the contrary considering the both factors show similar level of ventilation characteristics as EURO-3 emission regulation. Application of the emission standard set by the Ministry of Environment for newly manufactured vehicles in the current local tunnel design standard indicates higher requirements than for EURO-2 regulation, whereas the emission standard came into effect in 2006 results in the ventilation characteristics similar to EURO-4. This study aims at providing fundamental information for assessing the basic emission rate and determining the optimal ventilation rate and facility capacity considering the growing percentage of diesel cars and gradually decreasing level of smoke emission forced by the relevant laws.

  • PDF

A study on odor and ventilation in waste treatment facilities (폐기물 처리시설에서의 악취 및 환기에 관한 연구)

  • Seo, Byung-Suk;Jeon, Yong-Han
    • Design & Manufacturing
    • /
    • v.14 no.2
    • /
    • pp.28-33
    • /
    • 2020
  • Recently, as the income level and quality of life have improved, the desire for a pleasant environment has increased, and a deodorization plan is required through thorough prevention and diffusion of odorous substances in waste treatment facilities recognized as hateful facilities, appropriate collection, and selection of the right prevention facilities. In this study, a waste disposal facility was modeled and computerized analysis for odor and ventilation analysis was conducted. Numerical analysis of the waste treatment facility was performed at the size of the actual plant. CATIA V5 R16 for numerical model generation and ANSYS FLUENT V.13 for general purpose flow analysis were used as analysis tools. The average air-age of the internal was 329 seconds, and the air-flow velocity was 0.384m/s. The odor diffusion analysis inside the underground pump room showed congestion-free air circulation through streamline distribution and air-age distribution. This satisfies the ASHRAE criteria. In addition, the results of diffusion analysis of odorous substances such as ammonia, hydrogen sulfide, methyl mercaptan and dimethyl sulfide were all expected to satisfy the regulatory standards. Particularly in the case of the waste loading area, the air-flow velocity was 0.297m/s, and the result of meeting the regulatory standards with 0.167ppm of ammonia, 0.00548ppm of hydrogen sulfide, 0.003ppm of methyl mercaptan, and 0.003ppm of dimethyl sulfide was found.

Development of Road Tunnel Ventilation System with Electrostatic Precipitator (도로터널용 전기집진시스템 개발)

  • Kim, Jong-Ryul;Weon, Jong-Oung
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.80-83
    • /
    • 2008
  • As SOC (Social Overhead Capital) has been expanded, the highway road construction has been accelerated and city road system has been more complicated. So, long road tunnels have been increased and traffic flow rate also has been raised. Accordingly, the exhausting gas of vehicle cars seriously deteriorates the tunnel inside air quality and driving view. In order to improve tunnel inside air quality, we may need to introduce a compulsory ventilation system as well as natural ventilation mechanism. The natural ventilation mechanism is enough for short tunnels, meanwhile longer tunnels require a specific compulsory ventilation facility. Many foreign countries already have been devoting on development of effective tunnel ventilation system and especially, some European nations and Japan have already applied their developed tunnel ventilation system for longer road tunnels. More recently, as the quality of life improved, our concerns about safety of driving and better driving environment have been increased. In order to obtain clearer and longer driving view, we are more interested in EP tunnel ventilation system in order to remove floating contaminants and automobile exhaust gas. Evan though it's been a long time since many European countries and Japan applied more economical and environment-friendly tunnel ventilation system with their self-developed Electrostatic Precipitator, we are still dependant on imported system from foreign nations. Therefore, we need to develop our unique technical know-how for optimum design tools through validity investigation and continuous possibility examination, eventually in order to localize the tunnel ventilation system technology. In this project, we will manufacture test-run products to examine the performance of system in order to develop main parts of tunnel ventilation system such as electrostatic precipitator, high voltage power generator, water treatment system, etc.

  • PDF

A Ventilation Control Model System of Standby Generating Room Installed in Basement of Building (건물 지하층에 설치된 자가발전기실의 환기제어 모델 시스템에 관한 연구)

  • 홍원표;강병권
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.2
    • /
    • pp.75-82
    • /
    • 2000
  • This paper presents a new ventilation control model system of standby generating room installed in basement of building. The regulation problem & current status of ventilation system considered the architectural construction and building service facility procedure are also investigated. The regulation solution, ventilation control model system and its theoretical analysis for room of the generating system by driven diesel are proposed from the analyzed results of survey.

  • PDF

Verification Experiment and Simulation of Cooling Load for a Test Space with Forced Ventilation (시험공간에 강제환기를 고려한 냉방부하의 실증실험 및 시뮬레이션)

  • Kim, Dong-Hyeok;Yoo, Ho-Seon;Hong, Hi-Ki
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.217-222
    • /
    • 2005
  • Building energy consumption according to the ventilation has been considered to be an important subject. The purpose of this study is to investigate the cooling loads in a test space with a forced ventilating system. In the test space, on/off controlled air-conditioning and forced ventilating facility were operated between 8:30 to 21:00 during 4 days and some important data like temperatures and energy consumption were measured to obtain actual cooling loads. The simulation was carried out in a mode of temperature level control using a TRNSYS 15.3 with a precisely measured air change amount and performance data of air-conditioner. Cooling loads including sensible and latent were compared between by experiment and by simulation. Both of cooling loads associated with ventilation show a close agreement within an engineering tolerance.

  • PDF

Analysis of Ventilation Rates in Residential Buildings using a Multizone Network Model (멀티존 네트워크 모델을 이용한 주거용 건물의 환기량 분석)

  • Cha, Ji-Hyoung;Park, Cheol-Hun;Kim, Yeong-Ha;Baek, Chang-In;Han, Hwa-Taek
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.45-50
    • /
    • 2005
  • The supply outdoor airflow rates are calculated and analyzed using a multizone network model in a high-rise residential apartment. The system parameters include parameters related to weather conditions, building conditions, operation conditions, and facility conditions. Simulations are conducted according to the method of design of experiments and analysis of variance is conducted to investigate the effects of parameters on ventilation rate. A correlation equation is derived to predict ventilation rates of the building depending on the various parameters.

  • PDF

A Case Study on the Release Characteristic and Removal Efficiency of Vinyl Chloride in the Poly Vinyl Chloride Extrusion Process (PVC압출공정의 염화비닐 발생특성과 작업환경개선에 관한 사례연구)

  • Park, Dong Uk
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.3 no.1
    • /
    • pp.91-98
    • /
    • 1993
  • This study was carried out to investigate characteristic of vinyl chloride emissioned from poly vinyl chloride extrusion process and to evaluate the efficiency of local exhaust ventilation system. Before local ventilation facility was constructed in poly vinyl chloride extrusion process, the average worker exposure to vinyl chloride was 3.15 ppm, which exceeded Threshold Limit Value of American Conference of Gorvernmental Industrial Hygienists (ACGIH-TLV), 1 ppm. lt is possible that vinyl chloride residues in the poly vinyl chloride resin was released or degased due to extrusion heat. The larger the width of vinyl tube become, the higher worker exposure to vinyl chloride was. It is estimated that vinyl chloride from vinyl chloride resin increased as amount of poly vinyl chloride resin extruded in the extrusion process increased. Canopy hood was an appropriate type for poly vinyl chloride resin extrusion process. This local exhaust ventilation has fan static pressure of 7.65 inch wg($190mmH_2O$, total volumetric flowlate of 4,796 CFM ($135.8m^3$/min) and fan power requirement of 12 hp (8.952 Kw). After this local exhaust ventilation was constructed there, the average concentration of worker exposure to vinyl chloride was reduced to be 0.46 ppm, which was below the Threshold Limit Value, 1 ppm. Also, the removal efficiency rate of vinyl chloride attained by local exhaust ventilation was 85.3%. It was a statistically significant (p<0.01).

  • PDF

A Practical usage of industrial local ventilation facility and energy saving in the industrial ventilation (산업용 국소환기장치 활용 및 공장환기의 에너지절약)

  • 심광진;이동호
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.28 no.6
    • /
    • pp.433-442
    • /
    • 1999
  • 기원전 27세기경, 고대 이집트의 피라미드건설을 위해 앗시리아 지방에서 나일강변으로 이주한 기술자들의 집합주택에는 거의 환기구가 설치되어 있었다는 기록이 있다. 이 환기방법은 실내와 실외의 기온차에 의한 공기의 부력을 이용한 중력환기로 생각된다. 중력환기는 지금도 주물공장 등의 고온, 발열을 수반하는 작업장에서 적용되고 있으며, 이와 같이 자연력을 이용한 환기를 자연환기라 부른다.

  • PDF

Analysis of Ventilation Performance of PCVD Facility for Solar Cell Manufacturing (Explosion Prevention Aspect) (태양전지 제조용 PCVD설비의 환기 성능 분석(폭발 방지 측면))

  • Lee, Seoung-Sam;An, Hyeong-hwan
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.5
    • /
    • pp.35-40
    • /
    • 2022
  • PCVD (Plasma Chemical Vapor Deposition), a solar cell manufacturing facility, is a facility that deposits plasma generated in a chamber (NH3, SIH4, O2 on a wafer. In the PCVD facility, gas movement and injection is performed in the gas cabinet, and there are many leak points inside because MFC, regulator, valve, pipe, etc. are intricately connected. In order to prevent explosion in case of leakage of NH3 with an upper explosive limit (UEL) of 33.6% and a lower explosive limit (LEL) of 15%, the dilution capacity must be capable of allowing the concentration of NH3 to be out of the explosive range. This study was analyzed using the CFD analysis technique, which can confirm the dilution ability in 3D and numerical values when NH3 gas leaks from the existing PCVD gas cabinet. As a result, it was concluded that it corresponds to medium dilution and that testicular ventilation is possible through facility improvement.

Study on Discharge Electrode Design applied for Road Tunnel (터널용 전기집진시스템 개발을 위한 방전극 설계)

  • Kim, Jong-Ryul;Weon, Jong-Oung;Jang, Chun-Man
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1238-1243
    • /
    • 2009
  • As Social Overhead Capital(SOC) has been expanded, the highway road construction has been accelerated and city road system has been more complicated. So, long road tunnels have been increased and traffic flow rate also has been raised. Accordingly, the exhausting gas of vehicle cars seriously deteriorates the tunnel inside air quality and driving view. In order to improve tunnel inside air quality, it is needed to introduce a compulsory ventilation system as well as natural ventilation mechanism. The former, that is, a special compulsory ventilation facility is very useful and helpful to prevent a tunnel of being contaminated by traffic in most case. In the case of obtaining clearer and longer driving view, the ventilation systems have to be considered in order to remove floating contaminants or exhaust gas from engines. In this paper, discharge electrode design technology will be discussed.

  • PDF