• Title/Summary/Keyword: Ventilation effect

Search Result 647, Processing Time 0.039 seconds

A Study on the Inflow Velocity Reduction Measures in Case of Fire Great Depth Underground Double-Deck Tunnel (대심도 복층터널 화재 시 유입풍속 저감방안 연구)

  • Yang, Yong-Won;Moon, Jung-Joo;Shin, Tae-Gyun
    • Fire Science and Engineering
    • /
    • v.30 no.2
    • /
    • pp.81-86
    • /
    • 2016
  • Recently, frequent traffic congestion has occurred in domestic urban roads. As a solution for downtown traffic congestion in domestic urban roads, plans for great depth underground double-deck tunnels have been made. Great depth underground double-deck tunnels that have been planned for passenger cars, has the structure of a network type; the entry of vehicles is carried out in the underground space. In these network great depth underground double-deck tunnels, the cross section and the height of the tunnel are smaller than the general road tunnel, and the smoke of a fire will propagate faster than the evacuation of tunnel passengers by the action of the traffic-ventilation and casualties are expected. Therefore, in the present study, an attempt was made to prevent the delay system for fire smoke diffusion at the time of a fire in a domestic network great depth underground double-deck tunnel according to the area of the tunnel block during the operation of the delay system for fire smoke diffusion to analyze the effects of reducing the inflow velocity. When the area of the tunnel block was not less than 50%, the effect of reducing about 21% of the wind speed acting on the tunnel was significant. If the area is more than 50%, the diffusion rate of fire smoke was reduced by approximately 21%, which will be useful for a safe evacuation.

Assessment of Conscious Coginition Degree and Survey on the Indoor Air Quality at a public School in Seoul (서울시 일부 학교의 실내 공기질 조사 및 인식도 평가)

  • Sohn, Jong-Ryeul;Byeon, Sang-Hoon;Kim, Young-Whan;Kim, Jong-Hyeok;Cho, Yun-Su;Lee, Jae-Young;Park, Youn-Ju
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.3 s.49
    • /
    • pp.100-109
    • /
    • 2003
  • Recently, Indoor air quality(IAQ) in workplace, residential environments and schools has been concern of people, scientists and related the public. And so in Seoul has recognized the healthy effect related to IAQ in schools. Therefore, the objective of this study reported in this article were to measure and compare the perception of IAQ of selected air pollutants at three different schools in Seoul. We performed a questionnaire survey of 400 students about their awareness for the importance of IAQ in our school. And we measured the IAQ of 3 schools considering as site region, construction year and studying level. The indoor air pollutants and parameters such as temperature, relative humidity, respirable particulate matter(PM10), formaldehyde(HCHO), total bacteria counts(TBC), carbon dioxide(CO$_2$), and noise were monitored in indoors. In results, all most response of occupant has recognized the awareness of IAQ at schools. The PMIO, TBC and Noise level of all schools were higher than the standard of the public 150 ${mu}$g/m$^3$ and 500CFU/m$^3$, the level formaldehyde(HCHO) was below 0.1 ppm of the healthy guideline of Korea And the concentration of CO$_2$ were investigated below 1,000 ppm of the standard implying ventilation in 2 schools except for 1 school(c school). Finally, the control of most important pollutants of IAQ in school were PM10, TBC and Noise. Therefore, it can be concluded that the indoor air quality of selected 3 schools studied was perceived as acceptable, it is recommended that the government related IAQ was suggested the guideline and control of IAQ problems in schools, and all member relating school need to be effort to reduce the exposure of sources to undesirable indoor pollutants such as Particlate and Noise.

Comparison of the Effects of CPR Training using Little Anne, BRAYDEN and HeartiSense (Little Anne, BRAYDEN, HeartiSense를 이용한 심폐소생술 교육효과 비교)

  • Kim, in-Hyeon;Choi, Uk-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.11
    • /
    • pp.290-296
    • /
    • 2017
  • Purpose: The purpose of this study was to compare the effects of CPR training according to the mannequin used for CPR training using Little $Anne^{(R)}$, $BRAYDEN^{(R)}$, and $HeartiSense^{(R)}$. Method: Research subjects were 90 firefighters who were not paramedics. They were divided into three groups, A, B, and C. Theoretical education was conducted for 50 minutes, and practical education was conducted in groups of three for 50 minutes, using Little $Anne^{(R)}$ for 30 people in Group A; $BRAYDEN^{(R)}$ for 30 people in Group B; and $HeartiSense^{(R)}$ for 30 people in Group C. The results of CPR were printed out using Resusci Anne $SkillReporter^{(R)}$, and the subjects were asked to fill in a questionnaire. Results: The following significant differences were noted: satisfaction index according to the mannequin, $x^2=81.050$, p<.000; reason for satisfaction, $x^2=91.050$, p<.000; ratio of accurate chest compression, F=5.087, p<.004; and ratio of accurate ventilation, F=10.54, p<.000. Conclusion: For the subjects who require accurate and efficient CPR training, it is judged that a mannequin that provides information to allow corrections in real-time would be effective, and have a high educational effect.

Effect of aeration on the physicochemical characteristics of livestock feces compost during composting period (퇴비화과정 중 공기공급 여부가 가축분뇨 퇴비의 물리화학적 특성에 미치는 영향)

  • Jeong, Kwang-Hwa;Kang, Ho;Kim, Tai-ll;Park, Chi-Ho;Yang, Chang-Buem
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.11 no.4
    • /
    • pp.57-65
    • /
    • 2003
  • Livestock farming is one of several industries that have faced criticism because of its impact on the water quality, soil contamination and air pollution. The livestock feces can cause some environmental problems. The best way to treat the feces is to recycle the manure as an organic fertilizer after fermentation or composting. This study was carried out to investigate the characteristics of composting of manure in several composting conditions. The variations of physicochemical characteristics of each compost piles containing different level of air volume were analyzed throughout the composting period. In this study, pigs manure compost piles mixed with saw dust were composted in 110L of laboratory scale plastic vessels and $1.5m^3$ of small cubic wooden composting vessels for 60days. The compost piles were ventilated continuously with air pump throughout the composting duration. The air volume ventilated into the piles was regulated by chock valve attached to the inlet pipe. The ventilation level was adjusted by 20, 50, 100, 150 and $200L/m^3/mim$, respectively. The highest temperature of the compost increased to $72^{\circ}C$ during composting period. After 20days from beginning of fermentation, concentrations of $H_2S$, $CH_3SH$, DMS and DMDS generated from compost piles were 29, 16, 6 and 5ppb in blow in state compost pile, conversely, in blow out state compost pile, the parameters were 32, 24, 15 and 14ppb, respectively.

  • PDF

Initial Risk Assessment of Acetanilide with Respect to Human Health (아세트아닐리드의 초기 인체위해성 평가)

  • Lee, Su-Rae;Park, Seon-Ju;Lee, Mi-Kyung;Nam, U-Kyung;Chung, Sun-Hwa;Seog, Geum-Su;Park, Kwang-Sik;Kim, Kyun;Kim, Yong-Hwa
    • Environmental Analysis Health and Toxicology
    • /
    • v.15 no.1_2
    • /
    • pp.31-37
    • /
    • 2000
  • Acetanilide may be released into the environment through air and wastewater from its production and use sites and exposed to human. Acetanilide is known to produce an analgesic effect and may pose adverse effects on human health by overly exposure. According to the EUSES system, acetanilide showed a high MOS (Margin of safety) value exceeding 6$\times$10$^4$ on a regional exposure, which is safe enough for public health. Whereas the lowest MOS value in dermal exposure was estimated as 3$\times$10$^{-4}$ on a local basis (workplace), the risk could be partly counteracted by taking preventive measures such as using mask and globes and good ventilation in the work places. Acetanilide may pose a potential risk for workers by dust inhalation. For the sake of health protection in the work places, additional data should be accumulated with respect to repeated dose toxicity, reproduction toxicity and developmental toxicity, etc. It is, therefore, recommended that acetanilide should be a candidate for further work to supplement the lacking data until it is proved to be safe in the occupational health aspects.

  • PDF

Separate type heat pipe performance comparison by the heat exchanger shapes (열교환기 형상에 따른 분리형 히트파이프 성능 비교)

  • Jeon, Sung-Taek;Cho, Jin-Pyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.12
    • /
    • pp.723-729
    • /
    • 2016
  • This study compared fin-tube and parallel-flow heat pipes for their sensible heat exchange rate, heat recovery amount, and air-side pressure drop. Tests were done with different refrigerant charging rates of 40-60% vol. and air flow rates of 300-1,400. The sensible heat exchange rate was highest for both types of heat pipes at a working fluid charge of 40% vol. and low flow rate. For the parallel-flow heat pipe, the 60% vol. charge is too high and results in a low sensible heat exchange rate. The reason is that the thicker liquid film of the tube wall deteriorates the heat transfer effect. Hence, the optimal charging rate is 40 to 50% vol. The evaporator heat pipe has a larger air-side pressure drop than the condenser section heat pipe. The reason is considered to be condensation water arising from the evaporator surface. Compared to the fin-tube heat pipe, the parallel-flow heat pipe showed better performance with a working fluid charging rate of 48%, volume of 41%, and an air-side pressure drop about 37%.

Design & Performance of the Solar Energy Research & Test Center (태양에너지 연구 시험센타 설계 및 효율에 관한 연구)

  • Auh, Paul Chung-Moo;Lee, Jong-Ho;Choi, Byung-Owan;Cho, Yil-Sik
    • Solar Energy
    • /
    • v.2 no.2
    • /
    • pp.29-36
    • /
    • 1982
  • The Solar Energy R&D Department of KIER under the auspice of the Korean government is pushing hard on the development of the passive solar technology with high priority for the expeditious widespread use of solar energy in Korea, since the past few years of experiences told us that the active solar technology is not yet ready for massive commercialization in Korea. KIER has completed the construction of the Solar Energy Research & Test Center in Seoul, which houses the major facilities for its all solar test programs. The Center was designed as a passive solar building with great emphasis on the energy conserving ideas. The Center is not only the largest passive building in Korea, but also the exhibit center for the effective demonstration of the passive heating and cooling technology to the Korean public. The Center was designed to satisfy the requirements based on the technical and economical criteria set by the KIER. Careful considerations, therefore, were given in depth in the following areas to meet the requirements. 1) Passive Heating Concepts The Center employed the combination of direct and indirect gain system. The shape of the Center is Balcomb House style, and it included a large built-in sunspace in front. A partition, consists of transparent and translucent glazings, separates the sunspace and the living space. Since most activities in the Center occur during the day time, direct utilization of the solar energy by the living spaces was emphasized with the limited energy storage capacity. 2) Passive Cooling Concepts(for Summer) Natural ventilation concept was utilized throughout the building. In the direct gain portion of the system, the front glazing can be openable during the cooling season. Natural convection scheme was also applied to the front sunspace for the Summer cooling. Reflective surfaces and curtains were utilized wherever needed. 3) Auxiliary Heat ing and Cooling System As an auxiliary cooling system, mechanical means(forced convection system) were adopted. Therefore forced air heating system was also used to match the duct work requirements of the auxiliary cool ing system. 4) Effect ive Insulation & Others These included the double glazed windows, the double entry doors, the night glazing insulation, the front glazing-frame insulation as well as the building skin insulation. All locally available construction materials were used, and natural lightings were provided as much as possible. The expected annual energy savings (compared to the non-insulated conventional building)of the Center was estimated to be about 80%, which accounts for both the energy conservation and the solar energy source. The Center is being instumented for the actual performance tests. The experimental results of the simplified tests are discussed in this paper.

  • PDF

The Effect of Mandibular Protrusion on Dynamic Changes in Oropharyngeal Caliber (하악의 전방이동이 구인두 내경의 동적 변화에 미치는 영향)

  • Jung, Jae-Kwang;Hur, Yun-Kyung;Choi, Jae-Kap
    • Journal of Oral Medicine and Pain
    • /
    • v.35 no.3
    • /
    • pp.193-202
    • /
    • 2010
  • The purpose of this study was to determine the sites of narrowing/obstruction and to measure the regional severity of narrowing through the evaluation of dynamic changes in upper-airway of healthy subjects. The selected 9 subjects were proved not to have any sleep-related disorder such as snoring or obstructive sleep apnea through clinical examination, radiological examination, sleep study with a portable recording system. Afterward, the Electron Beam Tomography was performed during the waking and sleeping state of subjects, with their mandible in resting and protruded position. Intravenous injection of Dormicum$^{(R)}$ was used for the induction of sleep. The maximum and minimum cross-sectional areas at each airway level during tidal ventilation were measured and the Collapsibility Index for each level of cross-section was also computed. In a comparison with results under variable conditions, the result was showed that the significant difference between each airway level divided with upper, middle, lower region of upper airway is not observed in the average minimum cross-sectional areas and Collapsibility Index. The significant difference only between in wake and sleep state was observed in the average minimum cross-sectional area at the lower region. Also, in wake state, the significant difference between resting and protrusive position of mandible for the average minimum was also observed in cross-sectional area at middle region. In sleep state, no significant difference between resting and protrusive position of mandible was observed in cross-sectional area and the Collapsibility Index.

Effect of Preadmission Metformin Use on Clinical Outcome of Acute Respiratory Distress Syndrome among Critically Ill Patients with Diabetes

  • Jo, Yong Suk;Choi, Sun Mi;Lee, Jinwoo;Park, Young Sik;Lee, Chang-Hoon;Yim, Jae-Joon;Yoo, Chul-Gyu;Kim, Young Whan;Han, Sung Koo;Lee, Sang-Min
    • Tuberculosis and Respiratory Diseases
    • /
    • v.80 no.3
    • /
    • pp.296-303
    • /
    • 2017
  • Background: Acute respiratory distress syndrome (ARDS) is related to high mortality and morbidity. There are no proven therapeutic measures however, to improve the clinical course of ARDS, except using low tidal volume ventilation. Metformin is known to have pleiotropic effects including anti-inflammatory activity. We hypothesized that pre-admission metformin might alter the progress of ARDS among intensive care unit (ICU) patients with diabetes mellitus (DM). Methods: We performed a retrospective cohort study from January 1, 2005, to April 30, 2005 of patients who were admitted to the medical ICU at Seoul National University Hospital because of ARDS, and reviewed ARDS patients with DM. Metformin use was defined as prescribed within 3-month pre-admission. Results: Of 558 patients diagnosed with ARDS, 128 (23.3%) patients had diabetes and 33 patients were treated with metformin monotherapy or in combination with other antidiabetic medications. Demographic characteristics, cause of ARDS, and comorbid conditions (except chronic kidney disease) were not different between metformin users and nonusers. Several severity indexes of ARDS were similar in both groups. The 30-day mortality was 42.42% in metformin users and 55.32% in metformin nonusers. On multivariable regression analysis, use of metformin was not significantly related to a reduced 30-day mortality (adjusted ${\beta}-coefficient$, -0.19; 95% confidence interval, -1.76 to 1.39; p=0.816). Propensity score-matched analyses showed similar results. Conclusion: Pre-admission metformin use was not associated with reduced 30-day mortality among ARDS patients with DM in our medical ICU.

A Study on Factors Affecting Airborne Fume Composition and Concentration in Welding Process (용접공정에서 발생된 공기중 흄의 조성과 농도에 영향을 미치는 요인에 관한 연구)

  • Shin, Yong Chul;Yi, Gwang Yong;Park, Seung Hyun;Lee, Na Roo;Jeong, Jee Yeon;Park, Jung Keun;Oh, Se Min;Moon, Young Hahn
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.7 no.2
    • /
    • pp.181-195
    • /
    • 1997
  • The purpose of this study was to investigate factors affecting the composition and concentrations of fumes generated from various types of welding processes. The results are as follows. 1. Iron(Fe), zinc(Zn) and manganese(Mn) were predominant in Welding fumes. The Fe content in total fumes was 25.5% in coated electrode and 28.2% in $CO_2$ are welding, and the Zn content was 4.5% and 9.1%, respectively, and the Mn was 3.6% and 7.8%, respectively. 2. It was found that the important factors determining composition and concentration of fumes were type of industries, type of welding processes, type and composition of electrodes, composition of base metals, confinement of workplaces or condition of ventilation, work intensity, coated metals such as lead and Zn in paint. 3. The Mn content in airborne fumes was highly correlated with that of electrode(r=0.77, p<0.01) and was about 4 times higher than that in electrodes or base metals. The results lindicate that Mn is well evaporated into air during welding. The higher vapor pressure of Mn may explain this phenomenon. 4. the airborne total fume concentrations were significantly different among types of industries(p<0.001). The airborne total fume concentration was higher in order of sleel-structure manufacturing($GM=15.1mg/m^3$), shipbuilding($GM=13.2mg/m^3$), automobile-component manufacturing ($GM=7.8mg/m^3$) and automobile assembling industry($GM=3.0mg/m^3$) 5. The airbone total fume concentration was 6 times higher in $CO_2$ welding than in coated electrode welding, and approximately 3 times higher in confined area than in open area, in steel-structure manufacturing industry. 6. The concentration of welding fume outside welding helmet was about 2 times higher than that inside it. It is recommened that air sampling be done inside helmet to evaulate worker's exposure accurately, for it has an outstanding effect on reducing worker exposure to fumes and other contaminants.

  • PDF