• Title/Summary/Keyword: Ventilation effect

Search Result 647, Processing Time 0.029 seconds

Effect of Modified Cyclone Dust Collector in Windowless Broiler Building (변형된 사이클론 먼지포집기의 이용이 무창계사의 먼지농도에 미치는 영향)

  • Choi, H.C.;Yeong, G.Y.;Song, J.I.;Kang, H.S.;Kwon, D.J.;Yoo, Y.H.;Yang, C.B.;Chun, S.S.;Kim, Y.K.
    • Journal of Animal Environmental Science
    • /
    • v.13 no.2
    • /
    • pp.97-104
    • /
    • 2007
  • This study was carried out to develop the modified cyclone dust collector in windowless broiler building measuring 12 m wide, 46 m long, with a side wall height of 3 m and a capacity of 12,800 birds. Ventilation rate in windowless broiler building was $0.014{\sim}0.015\;and\;0.158{\sim}0.181cmm$ in second weeks and fifth weeks of age, respectively. Ammonia concentration was $13{\sim}16\;and\;20{\sim}24\;ppm$ in first and second weeks of age, respectively. Amount of dust collected in dust collector each week was 104.1, 274.7 and 388.6g in first, second and third weeks of age. But it was decreased from fourth weeks of age because of the increased ventilation rate. Total suspended particulate(TSP) of polluted air was $3,111.7{\sim}8,745.2{\mu}g/m^3$, but it was decreased to $530.8{\sim}2,264.4{\mu}g/m^3$ when it passed through the dust collector. Collecting efficiency was $54.2{\sim}82.9%$ in TSP. But collecting efficiency of Particulate matter smaller than $1{\mu}g$ (PM1.0) was $7.6{\sim}33.8%$, and lower than TSP. TSP concentration in control broiler house was 1,387.6 and $4,210.1{\mu}g/m^3$ in first and fourth weeks of age, respectively. But it was decreased to 876.3 and $2,535.3{\mu}g/m^3$ in broiler house operated dust collector in first and fourth weeks of age, respectively. Dust collecting efficiency for TSP was $36.8{\sim}39.8%$, and it was decreased to $11.4{\sim}39.8%$ in smaller dust size.

  • PDF

A study on the effect of air velocity through a damper on smoke extraction performance in case of fire in road tunnels (도로터널 화재 시 집중배기방식의 배기포트 통과풍속이 배연성능에 미치는 영향에 관한 연구)

  • Ryu, Ji-Oh;Na, Kwang-Hoon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.22 no.4
    • /
    • pp.347-365
    • /
    • 2020
  • In order to resolve traffic problems in urban areas and to increase the area of green spaces, tunnels in downtown areas are being increased. Additionally, the application of large port smoke extraction ventilation systems is increasing as a countermeasure to smoke extraction ventilation for tunnels with high potential for traffic congestion. It is known that the smoke extraction performance of the large port smoke extraction system is influenced not only by the amount of the extraction flow rate, but also by various factors such as the shape of the extraction port (damper) and the extraction air velocity through a damper. Therefore, in this study, the design standards and installation status of each country were investigated. When the extraction air flow rate was the same, the smoke extraction performance according to the size of the damper was numerically simulated in terms of smoke propagation distance, compared and evaluated, and the following results were obtained. As the cross-sectional area of the smoke damper increases, the extraction flow rate is concentrated in the damper close to the extraction fan, and the smoke extraction rate of the damper in downstream decreases, thereby increasing the smoke propagation distance on the downstream side. In order to prevent such a phenomenon, it is necessary to reduce the cross-sectional area of the smoke damper and increase the velocity of passing air through the damper so that the pressure loss passing through the damper increases, thereby reducing the non-uniformity of smoke extraction flow rate in the extraction section. In this analysis, it was found that when the interval distance of the extraction damper was 50 m, the air velocity passing through damper was 4.4 m/s or more, and when the interval distance of the extraction dampers was 100 m, the air velocity passing through damper was greater than 4.84 m/s, it was found to be advantageous to ensure smoke extraction performance.

Study on the Pulmonary Function in Welding Fume Exposed Workers (용접흄 폭로 근로자들의 폐기능에 관한 연구)

  • Hong, Young-Seoub;Kim, Byoung-Gwon;Kim, Sung-Ryul;Dam, Do-Won;Kim, Jung-Man;Jung, Kap-Yull;Kim, Joon-Youn
    • Journal of Preventive Medicine and Public Health
    • /
    • v.28 no.1 s.49
    • /
    • pp.43-57
    • /
    • 1995
  • In order to study the effect of welding fume exposure upon the pulmonary function test, we examined 131 shielded arc welding workers, and 152 $CO_2$ arc welding workers as cases and 177 control workers for their general characteristics, and forced vital capacity (FVC), forced expiratory volume in one second $(FEV_{1.0})$, forced expiratory volume in one second as a percent of FVC $(FEV_{1.0}%)$, and maximal mid-expiratory flow (MMF) were obtained from the spirogram. In shielded arc welding group and $CO_2$ arc welding group, FVC, $FEV_{1.0},\;FEV_{1.0}%$, and MMF were significantly decreased than control group, especially marked in the MMF finding. The distribution of workers below normal range was as follows. in the shielded arc welding group, 2 workers(1.5%) for FVC, 17 workers(13.0%) for $FEV_{1.0}$, 5 workers(3.8%) for $FEV_{1.0}%$, 28 workers(21.4%) for MMF, and in the $CO_2$ arc welding group, 3 workers(2.0%) for FVC, 25 workers(16.4%) for $FEV_{1.0}$, 8 workers(5.3%) for $FEV_{1.0}%$, and 37 workers(24.3%) for MMF, and significant increase by exposure duration was found in MMF. The distribution of workers who had ventilation impairment was as follows: 5 workers(3.8%) for obstructive type, 2 workers(1.5%) for restrictive type in the shielded arc welding group, and 7 workers(4.6%) for obstructive type, 2 workers(1.3%) for restrictive type, and 1 worker(0.6%) was combined type of the $CO_2$ arc welding group. In the respect of these results, the significant pulmonary function and ventilatory impairment were observed in welding fume exposed workers who had not abnormal finding in chest X-ray, and MMF considered as the most sensitive pulmonary function index by welding fume exposure. Therefore even if it is hard to doing pulmonary function test in the first health examination of workers according to the Industrial Safety Health Act in the welding fume exposure workers, it is desirable to consider doing PFT. Also evaluating the ventilation impairment, it is necessary, to observe the change of MMF that marker of effort-independent portion.

  • PDF

Recent Progress in Air Conditioning and Refrigeration Research - A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2002 and 2003 - (공기조화, 냉동 분야의 최근 연구 동향 -2002년 및 2003년 학회지 논문에 대한 종합적 고찰 -)

  • Chung Kwang-Seop;Kim Min Soo;Kim Yongchan;Park Kyoung Kuhn;Park Byung-Yoon;Cho Keumnam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.12
    • /
    • pp.1234-1268
    • /
    • 2004
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2002 and 2003 has been carried out. Focus has been put on current status of research in the aspect of heating, cooling, air-conditioning, ventilation, sanitation and building environment/design. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation in diverse facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat transfer, humidity was also interesting to promote comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing research topics. Well developed CFD technologies were widely applied for analysis and design of various facilities and their systems. (2) Heat transfer characteristics of enhanced finned tube heat exchangers and heat sinks were extensively investigated. Experimental studies on the boiling heat transfer, vortex generators, fluidized bed heat exchangers, and frosting and defrosting characteristics were also conducted. In addition, the numerical simulations on various heat exchangers were performed and reported to show heat transfer characteristics and performance of the heat exchanger. (3) A review of the recent studies shows that the performance analysis of heat pump have been made by various simulations and experiments. Progresses have been made specifically on the multi-type heat pump systems and other heat pump systems in which exhaust energy is utilized. The performance characteristics of heat pipe have been studied numerically and experimentally, which proves the validity of the developed simulation programs. The effect of various factors on the heat pipe performance has also been examined. Studies of the ice storage system have been focused on the operational characteristics of the system and on the basics of thermal storage materials. Researches into the phase change have been carried out steadily. Several papers deal with the cycle analysis of a few thermodynamic systems which are very useful in the field of air-conditioning and refrigeration. (4) Recent studies on refrigeration and air-conditioning systems have focused on the system performance and efficiency enhancement when new alternative refrigerants are applied. Heat transfer characteristics during evaporation and condensation are investigated for several tube shapes and new alternative refrigerants including natural refrigerants. Efficiency of various compressors and performance of new expansion devices are also dealt with for better design of refrigeration/air conditioning system. In addition to the studies related with thermophysical properties of refrigerant mixtures, studies on new refrigerants are also carried out. It should be noted that the researches on two-phase flow are constantly carried out. (5) A review of the recent studies on absorption refrigeration system indicates that heat and mass transfer enhancement is the key factor in improving the system performance. Various experiments have been carried out and diverse simulation models have been presented. Study on the small scale absorption refrigeration system draws a new attention. Cooling tower was also the research object in the respect of enhancement its efficiency, and performance analysis and optimization was carried out. (6) Based on a review of recent studies on indoor thermal environment and building service systems, it is noticed that research issues have mainly focused on several innovative systems such as personal environmental modules, air-barrier type perimeterless system with UFAC, radiant floor cooling system, etc. New approaches are highlighted for improving indoor environmental conditions and minimizing energy consumption, various activities of building energy management and cost-benefit analysis for economic evaluation.

Analysis and Management Strategies of the Cold Air Characteristics in Hannamgeumbuk-Jeongmaek and Geumbuk-Jeongmaek (한남금북·금북정맥 일대의 찬공기 특성 분석을 통한 청주시 찬공기 관리방안)

  • SON, Jeong-Min;EUM, Jeong-Hee
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.22 no.2
    • /
    • pp.152-171
    • /
    • 2019
  • In this study, we analyzed the characteristics of the cold air generated in Hannamgeumbuk and Geumbuk-Jeongmaek and proposed their management strategies. We also suggested management strategies after analyzing detailed cold airflows for Cheongju located Hannamgeumbuk-Jeongmaek and we compared the degree of nighttime temperature reduction of the Jeongmaek by using data obtained from observatories located on Cheongju. We used KALM(Kaltluftabflussmodell), a cold air simulation model developed in Germanay and identified both cold airflows and altitude of cold air layers generated during 360minutes at night. As a result, the cold airflow generated in the Jeongmaek became strong and the cold air was appeared clearly in the western part of the Hannamgeumbuk-Jeongamek and in the northern part of the Geumbuk-Jeongmaek. The average velocity of cold airflow was recorded at 0.45m/s, and the maximum speed of cold airflow was recorded at 2.70m/s. The average height of the cold air layer was 104.27m/s and the maximum thickness was 255.0m. The average velocity of cold airflows in Cheongju was 0.51m/s and the average height of cold air layer was 48.87m high. The highest degree of nighttime temperature reduction appeared in the Cheongnamdae observatory($-3.8^{\circ}C$), where the altitude of the cold air layer is high. The results showed that cooling effect of Jeongmaek actually affected the temperature reduction during nighttime. Based on the results, we designated the main mountain area of the Jeongmaek with active cold air generation as "cold air conservation areas" and proposed the current forest and topography conservation. We also proposed to designate areas that facilitate the cold airflows as "cold air management areas" and to complement the function of Jeongmaek. This study could support the establishment of systematic management plans of the Jeongmaek. In addition, it is expected that the results can be applied as basic data for ventilation paths of Cheongju.

Mitigation Effect on Airborne Particulate Matter Concentration by Roadside Green Space Type and Impact of Wind Speed (도로변 녹지 유형별 미세먼지 농도 저감 효과와 이에 대한 풍속의 영향 연구)

  • Tae-Young Choi;Da-In Kang;Jaegyu Cha
    • Journal of Environmental Impact Assessment
    • /
    • v.32 no.6
    • /
    • pp.437-449
    • /
    • 2023
  • This study measured PM10 concentrations and wind speeds in buffer green spaces and neighborhood parks located along the road, and compared them with roadside measurementresults to understand the effect of mitigating PM10 concentrations by type of green space and the influence of wind speeds on it. As a result of the analysis, the effect of mitigating PM10 concentration was different depending on the type of roadside green space, and an increase in wind speed had a significant effect on reducing PM10 concentration. In buffer green areas with high planting density, wind speed was low and PM10 stagnated inside, resulting in the highest concentration. On the other hand, green areas in neighborhood parks with relatively low planting density had high wind speeds and the lowest PM10 concentration. The non-green area within the neighborhood park recorded the highest wind speed, which was advantageous for the spread of PM10, but the concentration was higherthan that of the green area. Therefore, in orderto reduce PM10 concentration in roadside green space, it is necessary to create green space with good ventilation, and the combined effect of green space and wind speed seems to be more advantageous in reducing PM10 concentration. Green spaces capture and remove PM inside, contributing to reducing the concentration of PM outside. In order to manage PM in the entire city and on roads, it is necessary to increase planting density and leaf area in roadside green spaces, such as buffer green spaces, so that PM can be removed within the green spaces. However, in green spaces such as neighborhood parks that are actively used by city residents, in orderto minimize damage to users due to PM, it is desirable to create green spaces with a structure that allows PM to spread to the outside rather than stagnate inside.

Effect of Ketanserin and Positive End Expiratory Pressure Ventilation on Hemodynamics and Gas Exchange in Experimental Acute Pulmonary Embolism (실험적 급성 폐동맥색전증에서 Ketanserin과 Positive End Expiratory Pressure Ventilation이 혈류역학 및 환기에 미치는 영향)

  • Lee, Sang-Do;Lee, Young-Hyun;Han, Sung-Koo;Shim, Young-Soo;Kim, Keun-Youl;Han, Yong-Chol
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.2
    • /
    • pp.135-146
    • /
    • 1993
  • Background: In acute pulmonary embolism it has been postulated that the constriction of bronchi and pulmonary artery secondary to neurohumoral response plays an important role in cardiopulmonary dysfunction in addition to the mechanical obstruction of pulmonary artery. Serotonin is considered as the most important mediator. Positive end expiratory pressure (PEEP) stimulates $PGI_2$ secretion from the vascular endothelium, but its role in acute pulmonary embolism is still in controversy. Methods: To study the cardiopulmonary effect and therapeutic role of Ketanserin, selective antagonist of 5-HT2 receptor, and PEEP in acute pulmonary embolism experimental acute pulmonary embolism was induced in dogs with autologous blood clot. The experimental animals were divided into 3 groups, that is control group, Ketanserin injection group and PEEP application group. Results: Thirty minutes after embolization, mean pulmonary arterial pressure and pulmonary vascular resistance increased and cardiac output decreased. $PaO_2,\;P\bar{v}O_2$ and oxygen transport decreased and physiological shunt and $PaCO_2$ increased. After injection of Ketanserin, comparing with control group, mean pulmonary arterial pressure, pulmonary vascular resistance and physiological shunt decreased, while cardiac output, $PaO_2$ and oxygen transport increased. All these changes sustained till 4 hours after embolization. After PEEP application pulmonary vascular resistance, $PaO_2$ and $PaCO_2$ increased, while physiological shunt, cardiac output and oxygen transport decreased. After discontinuation of PEEP, mean pulmonary arterial pressure and pulmonary vascular resistance decreased and were lower than control group, while $PaO_2$ and cardiac output increased and higher than control group. $PaCO_2$ decreased but showed no significant difference comparing with control group. Conclusion: It can be concluded that Ketanserin is effective for the treatment of acute pulmonary embolism. With PEEP hemodynamic status deteriorated, but improved better than control group after discontinuation of PEEP. Thus PEEP may be applied carefully for short period in acute pulmonary embolism if the hemodynamic status is tolerable.

  • PDF

Initial Risk Assessment of Acetanilide in OECD High Production Volume Chemical Program

  • Park, Hye-Youn;Park, Yoonho;Sanghwan Song;Kwon, Min-Jeoung;Koo, Hyun-Ju;Jeon, Seong-Hwan;Na, Jin-Gyun;Park, Kwangsik
    • Toxicological Research
    • /
    • v.18 no.1
    • /
    • pp.13-22
    • /
    • 2002
  • In Korea, 2,320 tonnes of acetanilide were mostly wed as intermediates for synthesis in phar-maceuticals or additives in synthesizing hydrogen peroxide, varnishes, polymers and rubber. Only small amount of 120 kg were wed as a stabilizer for hydrogen peroxide solution for hair colouring agents in 1998. Readily available environmental or human exposure data do not exist in Korea at the present time. However, potential human exposures from drinking water, food, ambient water and in work places are expected to be negligible because this chemical is produced in the closed system in only one company in Korea and the processing factory is equipped with local ventilation and air filtering system. Acetanilide could be distributed mainly to water based on EQC model. This substance is readily biodegradable and its bioaccumulation is low. Acute toxicity of acetanilide is low since the L $D_{50}$ of oral exposure in rats is 1,959 mg/kg bw. The chemical is not irritating to skin, but slightly irritating to the eyes of rabbits. horn repeated dose toxicity, the adverse effects in rats were red pulp hyperplasia of spleen, bone marrow hyperplasia of femur and decreased hemoglobin, hematocrit and mean corpuscular hemoglobin concentration. The LOAEL for repeated dose toxicity in rats was 22 mg/kg/day for both sexes. Acetanilide is not considered to be genotoxic. In a reproductive/developmental toxicity study, no treatment-related changes in precoital time and rate of copulation, impregnation, pregnancy were shown in all treated groups. The NOAELs for reproduction and developmental toxicity (off-spring toxicity) are considered to be 200 mg/kg bw/day and 67 mg/kg bw/day, respectively. Ecotoxicity data has been generated in a limited number of aquatic species of algae (72 hr- $E_{b}$ $C_{50}$; 13.5 mg/l), daphnid (48hr-E $C_{50}$ > 100 mg/l) and fish (Oryzias latipes, 96hr-L $C_{50}$; 100 mg/l). Form the acute toxicity values, the predicted no effect concentration (PNEC) of 0.135 mg/1 was derived win an assessment factor of 100. On the basis of these data, acetanilide was suggested as currently of low priority for further post-SIDS work in OECD.in OECD.D.

Assessment of Wear Comfort and the Development of One-piece Dresses with Persimmon Juice Dye-printed Fabrics (감즙염색 날염 소재 원피스 개발과 인체착용실험에 의한 생리반응 및 착용감 평가)

  • Park, Soon Ja;Kang, Inhyeng
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.38 no.1
    • /
    • pp.73-86
    • /
    • 2014
  • Persimmon juice dye-printed fabrics with printing were used for a Galot one-piece dress. The Galot dress was assessed in comparison to a white undyed one-piece dress of the same design through a wearing test conducted in a climatic chamber with an air temperature of $30{\pm}1^{\circ}C$, $50{\pm}5%$ R.H, and 0.2m/sec air movement on 4 healthy female subjects in their 20s. The subjects went through a 30-min stable period, a 30-min exercise of walking on a $5^{\circ}$ slope treadmill at 70m/min period, and a 20-min recovery period. In addition, a physiological reaction and subjective sensation were estimated. The results showed that significant differences were mostly observed from a sweating period that occurred during the latter half of the exercise. More specific results are as follows. First, skin temperature on the chest and mean skin temperature were significantly higher (p<.01) in rayon dyed sample dresses. Second, micro-humidity on the back showed a significant difference (p<.01). Both cotton and rayon persimmon juice dyed sample dresses produced lower microhumidity than their counterparts and as for cotton the difference occurred over the entire experimental period; however, it occurred after the middle of the exercise period for rayon. Third, the sweating rate on the back decreased in both cotton and rayon with persimmon juice dye but no significant difference was observed. Fourth, subjective three sensations revealed significant differences between cotton and rayon (p<.01), indicating that the subjects felt more cool, dryer and more comfortable in a cotton Galot. As described above, the analysis of physiological responses and the subjective sensation of undyed and dyed clothing shows the effect of persimmon juice dyeing. Persimmon juice dyeing also seemly increased air permeability, moisture regain and permeability facilitating body heat ventilation, as micro-humidity and sweat rate were lowered. However, this was not shown consistently in subjective responses on comfort especially when wearing rayon dresses.

Comparison Packing Materials for Proper MAP of Mixed Sprout Vegetables (혼합 싹채소의 MAP를 위한 포장재 비교)

  • Kang, Ho-Min;Choi, In-Lee;Kim, Il-Seop
    • Journal of Bio-Environment Control
    • /
    • v.17 no.3
    • /
    • pp.226-230
    • /
    • 2008
  • A comparison was made of the effect of different packaging materials on storability of mixed sprout vegetables (alfalfa, broccoli, cabbage, radish, and red radish) stored at $8^{\circ}C$. They were packaged by several kinds of films that were 50 fm thickness low-density polyethylene film (PE 50), 50 fm thickness polypropylene film (PP 50), $50{\mu}m$ thickness ceramic film (CE 50), $25{\mu}m$ thickness ceramic film (CE 25), $10\sim13{\mu}m$ thickness polyethylene film (wrap), and polyethylene terephthalate box with ventilation hole (box). The fresh weight of mixed sprouts packaged with different materials decreased below to 2% except box packages that decreased around 7% compared with initial weight. The atmospheres that were developed inside the different materials during storage differed significantly. The carbon dioxide and oxygen concentration of packages were kept properly with 5% in CE 25, but the PE 50 and CE 50 treatments showed higher carbon dioxide and lower oxygen concentration. So the off-flavor of mixed sprouts was more severe in the PE 50 and CE 50 treatment. The ethylene concentration of packages showed lowest in box treatment, followed by PP 50, wrap and CE 25 treatment. The overall quality of mixed sprouts was lower in PE 50 and CE 50 than CE 25 treatment after 10 days storage, supposed to be resulted from highest ethylene concentration and lowest oxygen concentration. Conclusionally, the CE 25 film that showed below 1% fresh weight loss, 5% carbon dioxide, 5% oxygen and below 4 ppm ethylene concentration in package may be a proper packaging material for mixed sprout vegetables.