Recent Progress in Methods of Generating Water Mist for Fire Suppression

  • Guangxuan, Liao;Xin, Huang;Beihua, Cong;Jun, Qin;Jianghong, Liu;Xishi, Wang
    • Journal of ILASS-Korea
    • /
    • v.11 no.4
    • /
    • pp.251-265
    • /
    • 2006
  • To prevent the ozonosphere from being destroyed by Halon, it is an urgent task to find out Halon replacement. As one of the replacements water mist have showed broad applications by its advantages: little pollution to environment (not destroying the ozone layer or bring green house effect), extinguishing fire quickly, consuming a small quantity of water and having little damage to the protected objects. The methods of generating water mist strongly influence fire suppression effectiveness, which determine the cone angle, drop size distribution, flux uniformity, and momentum of the generating spray. The traditional water mist nozzle included pressure jet nozzles, impingement nozzles and twin-fluid nozzles. All of them have more or less disadvantages for fire suppression. Therefore, many research institutes and corporations are taking up with innovations in mist generation. This article provided some recent studies in State Key Laboratory of Fire Science (SKLFS) of University of Science and Technology of China. SKLFS have investigated new methods of generating water mist (i.e. effervescent atomization and ultrasonic atomization). and self developed a series of nozzles and developed advanced DPIVS (Digital Particle Image Velocimetry and Sizing) technique. Characteristics of water mist (the distribution of droplet sizes, flux density, spray dynamics and cone angle) produced by these nozzles were measured under different conditions (work pressure, nozzle geometry, etc.) using LDV/APV and DPTVS systems. A series of experiments were performed to study the fire suppression effectiveness in different fire scenario (different kindsof the fuel, fire size and ventilation conditions). The fire extinguishing mechanisms of water mist was also discussed.

  • PDF

Effect of Greenhouse Cooling Method on the Growth and Yield of the Tomato cv. Momotaro in Warm Season (고온기 유리온실의 냉방방법이 토마토 생육 및 수량에 미치는 영향)

  • 이재한;박동금;권준국;엄영철;최영하
    • Journal of Bio-Environment Control
    • /
    • v.9 no.1
    • /
    • pp.60-64
    • /
    • 2000
  • This study was conducted to investigate effects of cooling methods on the growth and yield of tomato cv. momotaro in the glasshouse for four years from 1996 to 1999. Cooling methods were fan, fan and fogging, fan and shading(temp. control), fan and shading(radiation control), fan and shading (temp. control) with fogging. Fan, Fogging and Shading(temp. control) were operated automatically when air temperature was over 3$0^{\circ}C$. Amount of fogging was 500m1/min/100m$^2$and Droplets in a fog were 50 microns or smaller. Shading(radiation control) was operated automatically when solar radiation was over 500W/m$^2$. The growth and yield were the least in fan and shading(temp. control) method due to lack of light Intensity. Fogging method must be reconsidered for expensive equipment and maintenance expenses. As the matter stands, It is suggested to be the most considerable cooling method to increase ventilation rate with fan or use fan and shading(radiation control).

  • PDF

A Study on Economical Efficiency Evaluation of Semiforcing under Structure Watermelon Cultivators (반촉성 시설수박 재배농가의 경제적 효율성 분석)

  • Kim, Woong;Kim, Jai Hong
    • Korean Journal of Agricultural Science
    • /
    • v.33 no.2
    • /
    • pp.179-193
    • /
    • 2006
  • Technical efficiency of semiforcing watermelon growers is 0.8248 on average, and distributed between 0.6744 and 0.9268. The result showed that semiforcing watermelon growers had by 18% of technical inefficiency and could be assumed that increasing technical efficiency could induce watermelon production more increase. Consequently, if growers' technical efficiency were improved while other environments were constant, watermelon production could be increased. Following the results from the inefficiency effect model, all assumption coefficient such as growers age etc, are significant at 10% level. Estimate of dispersion parameter ${\gamma}$ is 0.89, which confirms those differences between practical output and frontier output were derived from the technical efficiencies among growers. Differences of production system between high and low level growers in production efficiency were showed at side altitude, ventilation and heat-retaining in section of facilities and automation, soil test and calcium application in section of environment management, transplant preparation and duration of pollination in section of crop management and shipment place, sorting degree and management record analysis in section of business management respectively. As a result of analyzing consulting data by using standard diagnosis table of watermelon cultivation under structure which cultivated on semi-forced watermelon growers, gap between high and low level growers was 7.0 points in facility automation section, 7.1 points in environment section, 8.8 points in crop management section and 13.6 points in business management section, respectively, which were the biggest one among them. In case of excluding information-related items from the evaluation index of business management section, changes of business achievement are to occur. Therefore, it is recommended for us to review the standard diagnostic table of watermelon cultivation under structure by dividing evaluation index of management section into management and information.

  • PDF

Full-scale Fire Suppression Test for Application of Water Mist System in Road Tunnel (미분무수 소화시스템의 도로터널 적용을 위한 실물 화재 실험)

  • Han, Yong-Shik;Choi, Byung-Il;Kim, Myung-Bae;Lee, Yu-Whan;So, Soo-Hyun
    • Fire Science and Engineering
    • /
    • v.25 no.3
    • /
    • pp.51-56
    • /
    • 2011
  • The full-scale experiments are carried out to investigate the fire suppression characteristics of water-based fire fighting systems in a road tunnel. Applied systems are the low-pressure water spray system at 3.5 bar and the high-pressure water mist system at 60 bar. The water flow rate of the high-pressure system is one sixth only of the water spray system. A passenger car and a heptane fuel pan with area of $1.4m^2$ are used as fire sources. A blower system is installed at the tunnel exit to realize the longitudinal ventilation conditions (0.9~3.8 m/s) in the tunnel. Temperatures from the fire source to the down-stream direction are measured by K-type thermocouple trees. The experimental results show that the cooling effect of the high pressure water mist system in the test conditions were equivalent to that of the low pressure water spray system for B-class fire.

Acute Pulmonary Embolism: Clinical Characteristics and Outcomes in a University Teaching Hospital (한 대학병원에서 급성 폐색전증으로 진단된 환자들의 임상적 특성 및 예후)

  • Chae, Jin-Nyeong;Choi, Won-Il;Park, Jie-Hae;Rho, Byung-Hak;Kim, Jae-Bum
    • Tuberculosis and Respiratory Diseases
    • /
    • v.68 no.3
    • /
    • pp.140-145
    • /
    • 2010
  • Background: Pulmonary embolism (PE) is a common clinical problem in the West that is associated with substantial morbidity and mortality. The diagnostic modality has been changed since 2001. This study retrospectively reviewed the PE mortality with the aim of identifying the risk factors associated with mortality since the multidetector computed tomography (MDCT) was introduced. Methods: We analyzed 105 patients with acute PE proven by multidetector CT or ventilation perfusion scan. The primary outcome measure was the all-cause mortality at 3 months. The prognostic effect of the baseline factors on survival was assessed by multivariate analysis. Results: The main risk factors were prolonged immobilization, stroke, cancer and obesity. Forty nine percent of patients had 3 or more risk factors. The overall mortality at 3 months was 18.1%. Multivariate analysis revealed low diastolic blood pressure and the existence of cancer to be independent factors significantly associated with mortality. Forty two PE patients were examined for the coagulation inhibitors. Four of these patients had a protein C deficiency (9.5%), and 11 had a protein S deficiency (26%). Conclusion: PE is an important clinical problem with a high mortality rate. Close monitoring may be necessary in patients with the risk factors.

Assessment of indoor air micro-flora in selected schools

  • Katiyar, Vinita
    • Advances in environmental research
    • /
    • v.2 no.1
    • /
    • pp.61-80
    • /
    • 2013
  • Quantification of viable forms of microbial community (bacteria and fungi) using culture-dependent methods was done in order to characterize the indoor air quality (IAQ). Role of those factors, which may influence the concentration of viable counts of bacteria and fungi, like ventilation, occupancy, outdoor concentration and environmental parameters (temperature and relative humidity) were also determined. Volumetric-infiltration sampling technique was employed to collect air samples both inside and outside the schools. As regard of measurements of airborne viable culturable microflora of schools during one academic year, the level of TVMCs in school buildings was ranged between 803-5368 cfu/$m^3$. Viable counts of bacteria (VBCs) were constituted 63.7% of the mean total viable microbial counts where as viable counts of fungi (VFCs) formed 36.3% of the total. Mean a total viable microbial count (TVMCs) in three schools was 2491 cfu/$m^3$. Outdoor level of TVMCs was varied from 736-5855 cfu/$m^3$. Maximum and minimum VBCs were 3678-286 cfu/m3 respectively. Culturable fungal counts were ranged from 268-2089 cfu/$m^3$ in three schools. Significant positive correlation (p < 0.01) was indicated that indoor concentration of viable community reliant upon outdoor concentration. Temperature seemed to have a large effect (p < 0.05, p < 0.01) on the concentration of viable culturable microbial community rather than relative humidity. Consistent with the analysis and findings, the concentration of viable cultural counts of bacteria and fungi found indoors, were of several orders of magnitude, depending upon the potential of local, spatial and temporal factors, IO ratio appeared as a crucial indicator to identify the source of microbial contaminants.

The Effects of Pillow Filling Materials on the Comfortable Sleep (베개 충전물의 소재가 쾌적수면에 미치는 영향)

  • Sung, Min-Jung;Sung, Su-Kwang
    • Fashion & Textile Research Journal
    • /
    • v.8 no.6
    • /
    • pp.713-720
    • /
    • 2006
  • Heat conductivity, height, size, elasticity of pillow, stability of shape, hygroscopicity, ventilation, temperature and easy movability, and so on, are considered to be some of major conditions that affect the comfortable sleep. Considering those factors together, the thermal properties, height, shape and feeling of touch, etc, of pillow must be taken into account. Though studies have been conducted to figure out the physical properties of mattress or pillows from the perspective of factors related to the environment of sleep, they are not enough to be used as an index to evaluate the qualitative aspect of sleep. This study tries to consider the effect of pillow filling materials on the comfortable sleep, for which EEG, ECG, EOG, EMG, RT, etc, are to be measured in an attempt to provide the basic data required in proposing the condition that may lead to a sound and comfortable sleep. Three types of pillows that are sold in the market were used for this research in order to evaluate the quality of sleep depending on the filling materials of pillow. All data were statistically processed and the following conclusions were drawn. It was found that the pillow with feathers provided the best comfort as the pillow A turned out to have the shortest sleeping latency(SL) from the perspective of comfort. The pillow B which used the polyethylene is deemed to be suitable for fatigue relieving purpose as it turned out to have the highest slow wave sleep(SWS), but no statistically significant difference was validated. Moreover, the pillow C which used the natural wool was found to have the narrowest contacting area of the pillow and head and provide a great warm heat comfort that may led to a sound sleep because the temperature below the pillow took the longest time to rise.

3D BIM-based Building Energy Efficiency Solution for Carbon Emission Reduction (탄소저감을 위한 3D BIM 기반 건물 에너지 효율화 방안)

  • Lee, Dong Hwan;Kwon, Kee Jung;Shin, Ju Ho;Park, Seunghee
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.3
    • /
    • pp.1235-1242
    • /
    • 2013
  • This study deals with the BIM (Building Information Modeling)-based energy performance analysis implemented in EnergyPlus. The BIM model constructed at Revit is updated at Design Builder, adding HVAC models and converted compatibly with the EnergyPlus. We can obtain the input values about HVAC system and building environment such as HVAC system efficient, the number of air changes and energy consumption of equipment on applying GAs (Genetic algorithms). After modification about HVAC system, Optimization about HVAC system energy consumption can be analyzed. In order to maximize the building energy performance, a genetic algorithm (GA)-based optimization technique is applied to the modified HVAC models. Throughout the proposed building energy simulation, finally, the best optimized HVAC control schedule for the target building can be obtained in the form of "supply air temperature schedule". Throughout the supply air temperature schedule is applied to energy performance simulation, we obtained energy saving effect result on simulation.

The effect of a risk factor on quantitative risk assessment in railway tunnel (철도터널에서 위험인자가 정량적 위험도 평가에 미치는 영향)

  • Yoo, Ji-Oh;Kim, Jin-Su;Rie, Dong-Ho;Shin, Hyun-Jun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.2
    • /
    • pp.117-125
    • /
    • 2015
  • Quantitative risk assessment (QRA) of railway is to create a variety of scenario and to quantify the degree of risk by a result of the product of accident frequency and accident. Quantitative risk Assessment is affected by various factors such as tunnel specifications, characteristics of the fire, and relation of smoke control and evacuation direction. So in this study, it is conducted that how the way of smoke control and the relation of smoke control and evacuation direction affect quantitative risk assessment with variables (the tunnel length (2, 3, 4, 5, 6 km) and the slope (5, 15, 25‰)). As the result, in a train fire at the double track tunnel (Area = $97m^2$), it is most efficient to evacuate to the opposite direction of smoke control regardless of the location of train in train fire. In addition, under the same condition, index risk in mechanical ventilation up to 1/10.

Biological monitoring of miners exposed to diesel exhaust using urinary 1-hydroxypyrene (디젤 연소물질에 노출된 광산 근로자에서 소변 중 1-hydroxypyrene을 이용한 생물학적 모니터링)

  • Lee, Jong Seong;Choi, Byung-Soon;Shin, Jae-Hoon;Shin, Yong Chul;Kim, Ki-Woong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.17 no.2
    • /
    • pp.144-152
    • /
    • 2007
  • Diesel vehicles are a significant source of fine carbon particle emissions including polynuclear aromatic hydrocarbons (PAHs). Urinary 1-hydroxypyrene (1-OHP) is firmly established as a useful biomarker of PAHs uptake in human. To investigate the exposure effect of PAHs in miners according to using diesel truck which was for transportation of ore, we measured urinary 1-OHP as the PAHs exposure biomarker, and analyzed the relationship between urinary 1-OHP concentration and using diesel truck. The study was performed on 118 workers (56 miners in factories using diesel truck, 62 miners in factories non-using diesel truck) and 21 controls. Urine samples were obtained at the end of shift on the survey day. There was no significance in comparison with the mean concentrations on urinary 1-OHP by age, BMI, work duration, smoking, drinking and ventilation type. But significant difference were found among urinary 1-OHP concentrations on factories according to using diesel truck (p=0.000). The urinary 1-OHP mean concentration on underground miners using diesel truck ($0.54{\mu}mol/mol$ creatinine) was higher than those of surface miners using diesel truck ($0.33{\mu}mol/mol$ creatinine, p=0.028), underground miners non-using diesel truck ($0.32{\mu}mol/mol$ creatinine, p=0.001) and controls ($0.22{\mu}mol/mol$ creatinine, p=0.000). In comparison with using status diesel truck, the urinary 1-OHP mean concentration of underground miners using diesel trucks was higher than those of other mine status. The study results would be beneficial to future environmental and biological studies of PAHs exposure to diesel exhaust in mines.