• 제목/요약/키워드: Ventilation control mode

검색결과 47건 처리시간 0.031초

차량용 에어컨필터 교환시점 알림 시스템 및 과농도 먼지 차단 시스템 (Auto Alarm System of Replacement Period for Vehicle Cabin Filter & Interception System of High Concentration Dust)

  • 이규세;변성욱;김영민;박성우;염영진
    • 대한기계학회논문집A
    • /
    • 제32권11호
    • /
    • pp.1035-1040
    • /
    • 2008
  • Replacement period for vehicle cabin filter of most automobiles is fixed without consideration of conditions of filter and environment. Auto alarm system of replacement period at vehicle cabin filter and interception system of high concentration dust were developed. Control program which is related with the AQS has been developed based on the circuit drive algorithm. This system is expected to be beneficial to passenger's health and to extend the life of the filter which regulates vehicle HVAC system by ventilation mode change at the time of high concentration dust.

한국형고속열차 보조전원장치 특성시험 (A characteristic test of Auxiliary power supply for High Speed Rolling stock 350 experimental (HSR-350x))

  • 정상훈;김동환;이병송;이태형
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2006년도 추계학술대회 논문집
    • /
    • pp.185-191
    • /
    • 2006
  • Auxiliary power supply developed by domestic technology has very important function that not only effect on main power converter & inverter system, traction motor and train control system which are related to performance of train, but also influence on power supply for HVAC(Heat, Ventilation, Air-conditioning) and lighting device which are related to comfort of passengers. This paper shows characteristic test results of auxiliary power supply such as working condition and performance, which is associated with velocity of train, operating mode and surrounding equipment, through test running. Also it shows the results deduced from comparison analysis between designed data and manufactory test data as measuring in put voltage of auxiliary power supply. And, it propose a modification of design parameter for stabilizing operation and improving reliability.

  • PDF

한국형고속열차 보조전원장치 특성시험 (A characteristic test of Auxiliary power supply for High Speed Rolling stock 350 experimental (HSR-350x))

  • 김동환;이병송;이태형;정상훈
    • 한국철도학회논문집
    • /
    • 제10권1호
    • /
    • pp.84-87
    • /
    • 2007
  • Auxiliary power supply developed by domestic technology has very important function that not only effect on main power converter & inverter system, traction motor and train control system which are related to performance of train, but also influence on power supply for HVAC(Heat, Ventilation, Air-conditioning) and lighting device which are related to comfort of passengers. This paper shows characteristic test results of auxiliary power supply such as working condition and performance, which is associated with velocity of train, operating mode and surrounding equipment, through test running. And, it propose a modification of design parameter for stabilizing operation and improving reliability.

Volume-Controlled Mode의 기계환기시 동일환 I:E Ratio하에서 Inspiratory Pause가 기도압 몇 가스교환에 미치는 영향 (The Effects of Inspiratory Pause on Airway Pressure and Gas Exchange under Same I:E ratio in Volume-controlled Ventilation)

  • 최원준;정성한;이정아;최강현
    • Tuberculosis and Respiratory Diseases
    • /
    • 제45권5호
    • /
    • pp.1022-1030
    • /
    • 1998
  • 연구배경: Volume controlled ventilation(VCV)시 inspiratory pause의 사용은 흡기시간을 연장하여 평균기도압을 상승시키고 가스교환을 호전시키는 것으로 알려져 있다. 그러나 같은 흡기시간을 유지하더라도 inspiratory pause를 사용하였을 경우 평균기도압과 가스교환의 변화에 대하여는 잘 알려지지 않았다. 방 법: 저자들은 VCV으로 기계호흡을 받는 12명의 환자를 대상으로 흡기산소농도, 상시호흡량, 호흡수 및 I : E ratio(1 : 3)는 변화시키지 않고 5%의 pause를 사용한 경우와 사용하지 않은 경우의 기도압 및 가스교환의 변화를 관찰하여 비교하였다. 결 과: 동맥혈 이산화탄소분압은 pause를 사용한 경우 $38.6{\pm}7.4$ mmHg로 시용하지 않은 경우의 $41.0{\pm}7.7$ mmHg보다 유의하게 낮았다 (p<0.01). 동맥혈 산소분압은 pause를 사용한 경우 $94.4{\pm}23.2$ mmHg로 사용하지 않은 경우의 $91.8{\pm}19.7$ mmHg보다 높은 경향이 있었으나 (p=0.054), 폐포-동맥혈 산소분압차$(P(A-a)O_2)$는 pause 유무에 따른 차이가 없었다 ($185.3{\pm}86.5$ mmHg vs. $184.9{\pm}84.9$ mmHg, P=0.766). 평균기도압은 pause를 사용한 경우 $9.7{\pm}4.0\;cmH_2O$로 사용하지 않은 경우의 $8.8{\pm}4.0\;cmH_2O$보다 유의하게 높았다 (p<0.01). Pause를 사용했을 때의 pause pressure와 pause를 사용하지 않을 때의 최고흡기압의 차이는 호흡기계의 저항과 역상관관계를 보였으나 (r=-0.777, p<0.01), pause가 없을 때의 최고흡기압에서 pause를 사용했을 때의 최고흡기압으로의 증가는 호흡기계의 저항과 정상관관계를 보여 (r=0.811, p<0.01), 평균기도압의 차이는 호흡기계의 저항과 유의한 정상관관계를 보였다(r=0.681, p<0.05). 평균기도압의 변화는 $PaCO_2$의 변화와 상관관계를 보이지 않았다. 결 론: Volume control ventilation시 동일한 1:3 의 I:E ratio하에서라도 5%의 inspiratory pause를 사용하는 것이 평균기도압을 더 높게 유지할 수 있으며 폐환기를 호전시킬 수 있는 것으로 사료되었다. 또한 호흡기계의 저항이 증가되어 있을수록 평균기도압의 상승이 많았으나 평균기도압의 상승 정도는 폐환기의 변화와 상관관계를 보이지 않았다.

  • PDF

PSD가 설치된 지하철 역사 내 화재 시 최적 배연시스템 연구 (A study on the optimal ventilation and smoke exhaust systems in case of fire in subway stations installed with PSD)

  • 김효규;유지오;김두영
    • 한국터널지하공간학회 논문집
    • /
    • 제20권2호
    • /
    • pp.527-539
    • /
    • 2018
  • 다수의 승객들이 이용하는 지하철은 안전과 공간의 쾌적한 환경관리가 필수적이며, 2003년 이후 기준 강화로 승강장 내에 스크린도어(PSD)를 반드시 설치해야 한다. 선행연구에 따르면 지하철 화재 시에 화재연기의 배연을 위해 배연설비의 설비용량 최적설계가 필요하다. 따라서 본 연구에서는 선행연구의 실험 결과를 바탕으로 3차원 수치해석기법을 이용하여 PSD가 설치된 승강장 내에서 화재발생 시 배연시스템 별로 CO가스와 Smoke의 유동을 분석하였다. 본 연구의 결과 비상시 상부 배연설비만 가동한 경우에는 CO 가스와 Smoke 농도는 653.8 ppm과 $768.4mg/m^3$로 피난 시 승객들의 위험이 큰 것으로 분석되었으며, 모든 배연설비를 가동하고 화재측 PSD만을 개방한 경우 CO 가스와 Smoke 농도 36.0 ppm 및 $26.2mg/m^3$를 보이며 화재연기의 전파범위가 줄어드는 것으로 분석되었다. 모든 배연설비를 가동하고 화재측 PSD를 미개방한 경우에는 화재연기 유입이 발생하지 않아서 대피환경에 있어 가장 효과적인 배연모드로 분석되었다.

주차환기 시스템이 차 실내 열부하에 미치는 영향에 관한 연구 (Study of Pre-ventilation Effects on the Cabin Thermal Load)

  • 이대웅
    • 한국자동차공학회논문집
    • /
    • 제22권5호
    • /
    • pp.84-90
    • /
    • 2014
  • The aim of this paper is to investigate the application of solar energy in reducing cabin thermal load. When a vehicle is parked under the sun in summer, the interior temperature can reach up to $70^{\circ}C$ depending on the solar intensity. Solar power, one of the green energies, is used in automobile air conditioning systems, in order to operate the blower. The power supply of a blower's voltage has been used in a solar sunroof experiment. At the climate wind tunnel, cabin temperature changes were conducted with various operating modes of an air handling system and the preventilation parking conditions of several vehicles, outdoors, was also examined. The test results of the solar sunroof, 39.3W power and 14.1% efficiency were obtained. The thermal load behavior was analysed with the air handling system operating mode differently according to the cabin temperature. By simply operating the blower, average cabin temperature decreased between $5^{\circ}C{\sim}10^{\circ}C$ in those vehicles parked outdoors in summer. This reveals that cabin thermal comfort can be improved without consuming the vehicle's extra energy, and that the performance of the air-conditioning system is better than those currently found in vehicles. Moreover, fuel economy will be increased as a result of the reduction in the use of the air-conditioning system, and many other human advantages will be gained. Such advantages include minimized VOCs and a healthy cabin environment.

무작위 속도 변화에 의한 트레드밀 보행훈련이 뇌졸중 환자의 폐기능에 미치는 영향 (Effects of Treadmill Walking Training with Randomized Walking Speed on Pulmonary Function in Persons with Chronic Stroke)

  • 박성훈;차용준;최윤희
    • 대한물리의학회지
    • /
    • 제11권4호
    • /
    • pp.71-78
    • /
    • 2016
  • PURPOSE: The purpose of this study was to investigate which treadmill walking training mode is more effective strategy for improving pulmonary function of persons with chronic stroke. METHODS: Twenty-one chronic stroke patients were allocated and randomly to an experimental group (treadmill training with randomized speed control, n=11) and a control group (treadmill training without speed change, n=10). All participants received 30 minutes of neurodevelopmental treatment. In addition, the two groups performed treadmill training for 20 minutes each time with or without speed change. Speed change was applied 40%, 50%, 60%, 70% of Heart Rate Reserve. All the exercise programs lasted six weeks, with five times per week. Pulmonary function was assessed before and after exercise program by using forced vital capacity (FVC), forced expiratory volume in one second (FEV1), and maximal voluntary ventilation (MVV). RESULTS: In the both groups, FEV1 was significantly increased after training (p<.05). Compared to the control group, the experimental group showed 11.9% larger amount of change (p<.05). In the experimental group, FVC and MVV were significantly increased after training (9.9%, 7.6%, respectively) (p<.05). But in the control group, there was no significant difference in the FVC and MVV after training. CONCLUSION: Treadmill training with randomized speed control will be a better positive rehabilitation program than treadmill training without speed change to improve pulmonary function in persons with chronic stroke.

실내외 환경과 사용자의 행동을 고려한 스마트 홈 서비스 시스템 (Smart Home Service System Considering Indoor and Outdoor Environment and User Behavior)

  • 김재정;김창복
    • 한국항행학회논문지
    • /
    • 제23권5호
    • /
    • pp.473-480
    • /
    • 2019
  • 스마트 홈은 가정의 가전제품, 에너지 소비 장치, 보안기기 등 모든 사물을 통신망으로 연결해 모니터링 및 제어할 수 있는 기술이다. 스마트 홈은 자동제어 뿐 아니라 상황과 사용자의 취향을 학습하고, 이에 맞는 결과를 스스로 제공하는 방향으로 발전하고 있다. 본 논문은 사용자의 행동을 감지하여 사용자의 특성에 맞는 쾌적한 실내 환경 제어 서비스를 할 수 있는 모델을 제안하였다. 전체 시스템 구성은 센서와 와이파이를 탑재한 ESP8266, 실시간 데이터베이스인 firebase, 스마트 폰 어플로 구성된다. 본 모델은 사용자가 가전기기 작동시의 학습모드, 학습 결과를 통한 학습 제어, 실내와 실외 센서의 값을 이용한 자동 환기 등의 기능으로 구분된다. 학습은 에어컨, 가습기, 공기청정지 등 가전기기 제어시의 온도와 습도에 대한 이동 평균을 이용하였다. 본 시스템은 데이터베이스에 지속적으로 수집된 데이터를 다양한 기계학습과 딥 러닝을 통해 사용자의 특성을 분석하고 예측하여 보다 고 품질의 서비스를 제공할 수 있다.

Wireless safety monitoring of a water pipeline construction site using LoRa communication

  • Lee, Sahyeon;Gil, Sang-Kyun;Cho, Soojin;Shin, Sung Woo;Sim, Sung-Han
    • Smart Structures and Systems
    • /
    • 제30권5호
    • /
    • pp.433-446
    • /
    • 2022
  • Despite efforts to reduce unexpected accidents at confined construction sites, choking accidents continue to occur. Because of the poorly ventilated atmosphere, particularly in long, confined underground spaces, workers are subject to dangerous working conditions despite the use of artificial ventilation. Moreover, the traditional monitoring methods of using portable gas detectors place safety inspectors in direct contact with hazardous conditions. In this study, a long-range (LoRa)-based wireless safety monitoring system that features the network organization, fault-tolerant, power management, and a graphical user interface (GUI) was developed for underground construction sites. The LoRa wireless data communication system was adopted to detect hazardous gases and oxygen deficiency within a confined underground space with adjustable communication range and low power consumption. Fault tolerance based on the mapping information of the entire wireless sensor network was particularly implemented to ensure the reliable operation of the monitoring system. Moreover, a sleep mode was implemented for the efficient power management. The GUI was also developed to control the entire safety-monitoring system and to manage the measured data. The developed safety-monitoring system was validated in an indoor testing and at two full-scale water pipeline construction sites.

FDS를 이용한 전기실의 화재모델링 및 연기제어 특성 분석 (Fire Modeling and Smoking Control Characteristic Analysis of Electric Room by Using FDS)

  • 최정아;이민구;이대동
    • 한국산학기술학회논문지
    • /
    • 제19권3호
    • /
    • pp.662-668
    • /
    • 2018
  • 전기실은 대부분 건물의 지하공간에 위치하고 있어 전기설비에서 화재가 발생할 경우 화학적 가공에 의해 제조된 케이블 절연재로 화재가 확대되어 강한 독성의 연기 및 연소생성물이 발생하게 된다. 이때 발생한 연기 및 연소생성물이 수직적, 수평적으로 빠르게 이동하게 되면 재실자의 피난 및 소방대의 소방 활동에 지장을 주게 된다. 따라서 전기실의 화재가 발생할 경우 연기제어에 필요한 최적의 설비 및 설계가 필요하지만 현재 이에 대한 연구는 미흡한 실정이다. 본 연구에서는 화재 시뮬레이션 프로그램 FDS(Fire Dynamics Simulator)를 기반으로 만들어진 PyroSim을 이용하여 전기실의 큐비클식 수배전반에서의 화재발생에 따른 연기 및 연소생성물의 특성변화를 분석하였다. 화재모델링은 기계식 환기설비의 작동여부, 급기량 및 배기량의 변화, 급기구의 위치 변경에 따른 4가지 시나리오로 구성하였다. 분석 결과, 기계식 환기설비가 작동하면 작동하지 않을 때보다 연기밀도, 가시거리, 일산화탄소 농도, 온도특성이 더욱 개선되어지며, 소방법 규정으로 풍량과 급기구의 위치를 적용할 경우 가시거리 및 온도특성이 개선됨을 확인하였다.