• 제목/요약/키워드: Ventilation condition

검색결과 443건 처리시간 0.025초

철도터널의 환기특성에 관한 연구 (The Characteristics of Ventilation in Railway Tunnel)

  • 유지오;신현준;이호석
    • 한국터널지하공간학회 논문집
    • /
    • 제2권2호
    • /
    • pp.22-31
    • /
    • 2000
  • 철도터널에서 오염물질의 거동은 열차의 운행조건 및 터널의 구조 등과 같은 다양한 인자에 의해 영향을 받아 매우 복잡한 양상을 보이게 된다. 본 연구에서는 SES프로그램을 수정하여 해석한 농도계산을 이용하여 철도터널에서 오염물질의 거동특성을 구명하고, 터널의 단면적, 길이 및 열차의 항력계수, 주행속도가 터널의 최대풍속 및 오염농도에 미치는 영향에 대한 분석결과를 제시하였다.

  • PDF

환기 조건에 따른 화재거동 연구 (On the Fire Behavior Due to the Ventilation Condition in the Fire Compartment)

  • 김성찬
    • 대한기계학회논문집B
    • /
    • 제32권5호
    • /
    • pp.367-373
    • /
    • 2008
  • A series of fire experiments has been conducted to provide an improved understanding of the fire structure of under-ventilated compartment fires. A comprehensive and quantitative assessment of gaseous species from the fire was made in the upper layer of fire in a 40 % reduced scale ISO 9705 fire compartment. The global equivalence ratio (GER) concept was used to characterize the fire behavior for various fire sizes, fuel types and ventilation conditions. The oxygen concentration in the upper layer reached to zero near the global equivalence ratio of $0.4{\sim}0.6$ while the carbon monoxide concentration increases with increasing the global equivalence ratio. Classification parameters of ISO19706 were also compared with the reduced scale experimental data for under ventilation fire.

고속버스 운행시 공조시스템 조건에 따른 객실 내 실내공기질 변화 (A study on the effect on indoor air quality by ventilation system operation in buses)

  • 안선민;이정섭;심인근;김호현
    • 실내환경 및 냄새 학회지
    • /
    • 제17권4호
    • /
    • pp.346-354
    • /
    • 2018
  • In this study, the condition of the hazardous materials in the bus was monitored according to the ventilation mode of the air conditioning system during bus service. The bus was surveyed using the indoor air quality measurement method of public transportation vehicles within one year of delivery. We evaluate the $CO_2$ and $PM_{10}$, which are the controlled parameters in buses by the Ministry of Environment, and VOCs and HCHO, the non-controlled parameters. The $PM_{10}$ concentration increased due to outdoor air intake; however the $CO_2$ concentration was found to decrease. In addition, the concentration of VOCs and HCHO was found to decrease due to the forced ventilation system and the outdoor air intake. These results show that the concentration of the other materials except $PM_{10}$ can be changed due to the outside air concentration and forced ventilation system. Therefore, through indoor air quality characteristics of the bus according to air condition system are intended to be used as the basis of an operation manual.

제연 팬 용량이 철도역사 연기확산에 미치는 영향 분석 (Simulation of Ventilation Capability Effect on The Smoke Spread in Railway Station)

  • 장용준;구인혁;김학범;김진호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.7-13
    • /
    • 2011
  • 본 연구에서는 최근 증가하고 있는 대심도역사의 제연 팬 용량에 따른 연기확산영향에 대하여 분석하였다. 시뮬레이션모델은 신금호 역사(5호선, 깊이 46m)를 대상으로 하였으며, 설계된 제연 용량과 실측 제연 용량의 차이에 따른 연기확산 영향을 분석 하였다. 현장조사 및 실측을 통하여 계측된 실제 역사의 제연 팬에 관한 데이터를 화재시뮬레이션 조건으로 적용하였다. 역사전체를 해석 대상으로 하여 총 400만개의 격자를 사용하였으며, 설계된 제연성능과 실측된 제연성능에 따른 연기확산 영향 비교를 위하여 화재 시나리오를 작성하여 Case별로 화재해석을 수행하였다. 계산 효율을 높이기 위하여 MPI병렬 처리기법을 사용하였으며 해석코드는 large eddy simulation 기법을 주로 사용하는 FDS code를 사용하였다.

  • PDF

대구지역의 국지적 대기순환풍의 환기경로에 관한 수치모의 실험 (Numerical Simulation Experiment on the Wind Ventilation Lane of the Local Circulation Winds in Daegu)

  • 구현숙;김해동;강성대
    • 한국환경과학회지
    • /
    • 제13권4호
    • /
    • pp.367-376
    • /
    • 2004
  • In urban area, thermal pollution associated with heat island phenomena is generally regarded to make urban life uncomfortable. To overcome this urban thermal pollution problem, urban planning with consideration of urban climate, represented by the concept of urban ventilation lane, is widely practiced in many countries. In this study, the prevailing wind ventilation lane of a local winds in Daegu during the warm climate season was investigated by using surface wind data and RAMS(Reasonal Atmospheric Model System) simulation. The domain of interest is the vicinity of Daegu metropolitan city(about 900 $km^{2})$ and its horizontal scale is about 30km. The simulations were conducted under the synoptic condition of late spring with the weak gradient wind and mostly clear sky. From the numerical simulations, the following two major conclusions were obtained: (1)The major wind passages of the local circulation wind generated by radiative cooling over the mountains(Mt. Palgong and Mt. Ap) are found. The winds blow down along the valley axis over the eastern part of the Daegu area as a gravity flow during nighttime. (2)After that time, the winds blow toward the western part of Daegu through the city center. As the result, the higher temperature region appears over the western part of Daegu metropolitan area.

환기가 제한된 세 개 격실에서 Pool Fire에 대한 FDS 검증분석 (Validation of FDS for Pool Fire in Three Rooms Connected to Ventilation Network)

  • 배용범;이상규;신병수;김남석;금오현;박종석
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2011년도 춘계학술논문발표회 논문집
    • /
    • pp.9-15
    • /
    • 2011
  • This study aims to validate predictive capabilities of FDS for the pool fire in three rooms connected to ventilation network. The three rooms in real scale fire test facility are configured to be similar to that of nuclear power plant in size, ventilation condition, construction material, etc. Basically three rooms are confined to the other area except two open doors and two ventilation duct in each room. The real scale fire test was conducted with these conditions and the predictive capabilities of FDS will be validated by comparing FDS simulation results with experimental data from the temperature, heat flux, and concentration point of view. This study concludes that temperature from FDS is about 25 % lower deviation from the experiment, and heat flux from FDS is about 5% deviation.

  • PDF

장대 터널 내 구난역의 열차 화재 시 제연을 위한 1D-3D 연계 해석 (The 1D-3D Simulation for Smoke Ventilation in a Rescue Station of a Railroad Tunnel under the Fire)

  • 정재혁;허남건;이정표;김진곤
    • 설비공학논문집
    • /
    • 제22권10호
    • /
    • pp.665-671
    • /
    • 2010
  • In the present study a 1D-3D numerical simulation was performed to analyze the fire safety in a rescue station of a long railroad tunnel equipped with a mechanical ventilation. The behavior of hot air was studied for the emergency operation mode of ventilation system in case of fire in the rescue station. The 1D simulation was carried out for entire tunnel region. Detailed 3D CFD simulation was performed for the rescue station area in the central region of the tunnel by using the result of the 1D simulation as the boundary condition of the 3D simulation. Various type of cross passage installation were evaluated for the prevention of smoke diffusion to suggest the optimized interval of the cross passages in the rescue tunnel.

지하역사 승강장 열환경 개선을 위한 연구 (제1보: 승강장 열환경 현황 및 실측결과) (The study for thermal environment improvement at subway station platform (Part 1: Thermal environment status and actual survey results))

  • 김희률;김동규;금종수;정용현;김종열;박성출
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.976-980
    • /
    • 2008
  • Ventilation equipment performs a cental role to maintain comfort subway environment. So ventilation equipment of Busan subway first line is needed to improvement thermal environment. In this study, condition of thermal environment is presented to improve ventilation equipment at existing subway station platforms by measuring thermal environment of platforms operated ventilation equipment at 14 stations of Busan subway first line. AWS of data in comparison with the neighbouring platforms and thermal environment analysis.

  • PDF

한국 전통주거의 기류 분석을 통한 자연통풍 설계 연구 (Natural Ventilation Planning by Analysis on Air Velocity Property of a Traditional Korean House)

  • 최윤정;김인선;허범팔
    • 한국실내디자인학회:학술대회논문집
    • /
    • 한국실내디자인학회 2001년도 춘계학술발표대회 논문집
    • /
    • pp.117-120
    • /
    • 2001
  • This study is a preliminary research to develop design principles for environmentally friendly housing. The purposes of study are to investigate the literatures related passive design for summer and theory of ventilation, to analyze the indoor airflow patterns in traditional Korean house during summer, and to propose the design factors for effective passive cooling system. The analysis for airflow patterns was focused on the ‘An bang’and the ‘Dae Chung’in the ‘An Chae’of a traditional house located in Seoul. Field measurements of air temperature and air velocity were carried out at 30 different measuring points with 8 different window-opening conditions. The measurements were taken on the hottest summer days in August 2000. It is concluded that from an environmentally friendly standpoint design factors to control indoor thermal environment by a passive cooling system during the summer are as follows; ceiling structure has thermal performance like a time-lag effect, optimum height and length of eaves which can prevent sunlight and divert airflow toward the sitting level, building arrangement acceptable the prevailing wind, strategic window arrangement which makes cross ventilation possible (especially north-south) at the sitting level, window opening condition which is possible to intersect two cross-ventilation stream at the main living areas, northward windows remaining in shade to create the air pressure difference, and planning building shape like a bracket that has optimum width and depth.

  • PDF

주방 조리시 미세먼지(PM2.5) 배출 특성과 관리방안 (Characteristics and Management of Particulate Matter(PM2.5) Emission on Cooking Condition)

  • 이명구;정명진;강민지
    • 문화기술의 융합
    • /
    • 제4권1호
    • /
    • pp.325-329
    • /
    • 2018
  • 실내 거주공간에는 건축 자재, 환기, 조리 등으로 인하여 많은 오염물질이 발생한다. 이중 미세먼지는 1급 발암물질로 인체에 매우 유해한 물질이며, 주로 조리시에 가장 많이 발생한다. 따라서 실내공기질을 잘 관리하기 위해서는 조리시 발생하는 미세먼지의 농도와 환기방법과의 관계를 평가할 필요가 있다. 이에 본 연구에서는 음식물의 종류 및 환기방법에 따른 미세먼지(PM2.5)의 농도변화를 측정하고 분석하여, 주방 조리시 발생하는 미세먼지의 관리방안을 제시하고자 하였다.