• Title/Summary/Keyword: Ventilation condition

Search Result 446, Processing Time 0.037 seconds

A Study on the Daylighting Control Method in a Storage Room (장경각의 일조환경 평가에 관한 연구)

  • Lee, Soo-Min
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.12 no.1
    • /
    • pp.45-51
    • /
    • 2012
  • To see sunlight condition around in storage room, this study analyzers the scope both of sunlight and of the shade of sun into upper and lower window according to seasons. For this, this study investigates sun's seasonal changes, its effect of sunlight and notes antinomic conditions for ventilation and draft performance. In this, Architects of Jangkyunggak tride to block discoloration and fading due to ultraviolet rays and visible rays and block deterioration drying of the surface of Kyung-Pan due to infrared rays by oppressing sunlight flowing by means of narrowing the area of the upper window at front face that has a direct influence of Pan-Ga to avoid the exposure to direct sunlight.

Construction Planning and Design of a Long Tunnel (장대 터널의 계획과 설계)

  • 장석부;윤영훈;김용일;김진한
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.03b
    • /
    • pp.117-124
    • /
    • 2000
  • This paper presents the construction planning and the detail design of a 16.2 km long railroad tunnel in a mountainous area. Major design conditions for railroad are the single track, loop-typed alinement, and a maximum grade of 24.5$\textperthousand$. A underground station(double track) with a length of 1.1km is located in the middle of the line for train cross-passing. Tunnel is excavated in highly complex geological conditions including faulted areas, abandoned mine works areas, and various rock types such as sandstone, shale, limestone, and coal seam partly. Drilling and blasting method was adopted because it is more flexible than TBM(Tunnel Boring Machine) as a result of risk assessment for geological conditions in this area. Two working adits were planned to adjust the construction schedule and can be used for ventilation and maintenance in operation phase. New material and concept were introduced to the tunnel drain design. They are expected to improve tunnel drain condition and capability. Rational tunnel support design was tried to consider the various tunnel size and purpose and to use the geological investigation results.

  • PDF

실내사무환경에서의 환경성담배연기(ETS) 중 지표물질에 관한 연구

  • Ha, Gwon-Cheol;Baek, Nam-Won;Park, Dong-Uk;Yun, Chung-Sik
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2005.11a
    • /
    • pp.154-159
    • /
    • 2005
  • The markers for Environmental Tobacco Smoke(ETS) a.e necessary to obtain, to interpretate and to provide the data of quantitative exposure assessment. The purpose of this research is to evaluate Indoor environment using the concentration of ETS and the correlations between markers(RSP, nicotine, 3-EP) and environmental conditions(smoking density, ventilation rate). The mean ACH(air change per hour) in smoking rooms showed non-compliance with ASHRAE standard value. The concentrations of RSP, 3-EP, nicotine showed log-normal distributions, and became different statistically depending on smoking condition(p<0.01). The geometric mean concentration of RSP in smoking room was 441.7 ${\mu}g/m^3$ that is far exceeded environmental standard(150 ${\mu}g/m^3$). The correlation coefficients between RSP and SI, 3-EP and SI, and Nicotine and SI were 0.67, 0.84, 0.74 respectively. The correlation coefficient between nicotine and 3-EP, Nicotine and RSP, and RSP and 3-EP were 0.76, 0.78, 0.57 respectively.

  • PDF

Dynamic Analysis of HVAC Case for Passenger Car (승용차용 HVAC Case의 동특성 해석)

  • Yook, Ji-Yong;Cha, Yong-Kil;Lim, Jung-Su;Kim, Kwang-Il;Kim, Sung-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.378-384
    • /
    • 2008
  • This Paper presents dynamic analysis of HVAC(Heating Ventilation & Air Condition) Heater Case which consists of heater and evaporator unit for passenger car. To analyze the dynamic characteristics of HVAC Heater Case. finite element model which consists of shell elements is constructed for modal analysis and experimental Modal analysis has been conducted. Finite element analysis results are compared with experimental results to evaluate of validity of finite element model After identifying node shape and natural frequency of HVAC Heater Case, local stiffness of HVAC Case is evaluated through point mobility using finite element analysis and experiment.

  • PDF

Simulation study for Bag-Valve-Mask application guideline on pathologic pulmonary condition (모형폐의 물리적 특성 변화에 따른 Bag-Valve-Mask의 사용방법 연구)

  • Choi, Hae-Kyung;Jung, Hyung-Keon
    • The Korean Journal of Emergency Medical Services
    • /
    • v.17 no.3
    • /
    • pp.21-28
    • /
    • 2013
  • Purpose: The purpose of this study is to get basic user guidelines of safe and efficient bag-valve-mask application on patients having abnormal pathophysiological pulmonary conditions. Methods: This study was performed by pre-qualified 35 EMS junior and senior students. Participants were instructed to compress ambulatory bag randomly about half, one-third, one-fourth within different airway resistance and pulmonary compliance. Resultant tidal volume and pulmonary wedge pressures on RespiTranier monitor were analysed in relation to pulmonary physiologic index. Results: At least over half compression of bag guaranteed minimal tidal volume regardless of pulmonary conditions. There was no increase of pulmonary wedge pressure above the level of barotrauma on half compression at any pulmonary conditions. Conclusion: Assisted ventilation with ambulatory bag on patients with pathological pulmonary conditions should be over half compressed regardless of respiratory disease entity.

A Study on the Characteristics of the Apartment unit Plans According to the Outdoor Adjacency Methods (I) (외기인접방식에 따른 아파트 단위평면 특징에 관한 연구(I))

  • Park Mong-Sub
    • Journal of the Korean housing association
    • /
    • v.16 no.2
    • /
    • pp.19-25
    • /
    • 2005
  • This paper call attention to the characteristics of apartment unit plans as to the outdoor adjacency methods. My arguments will attempt to investigate spatial composition and each room sizes of the unit plans. So far, very little has been done in this direction. I will limits myself to study 573 plans which have been designed from 1996 till 2003. What emerges from this analysis is that these samples divided 3 types derived from the outdoor adjacency methods. Type 1 limits itself to 39 square meters unit plans. Type 2 was distributed from 49 square meters to 200 square meters with the exception of 100-110 square meters. And, type 3 ranges from 59 to 160 square meters. Therefore, it could be profitable each room's environmental condition (daylight, ventilation and etc) and diverse apartment building types to design in extent 49-160 square meters.

A Study on Friction Characteristics for Motorcycle Disk Using Taguchi Experimental Design (다꾸지 기법에 의한 이륜자동차 브레이크 디스크의 마찰특성에 관한 연구)

  • Juen, H.Y.;Ryu, M.R.;Lee, S.J.;Park, H.S.
    • Journal of Power System Engineering
    • /
    • v.10 no.3
    • /
    • pp.67-72
    • /
    • 2006
  • The effect of manufacturing parameters on wear and improve cooling of motorcycle break system was studied using a disk-on-pad type friction tester. Such parameters conditions have an effect on the wear and improve cooling factor such as applied load, sliding speed, frictional time and number of ventilated disk hole. However, it is difficult to know the mutual relation of these factor. In this study, the wear and cooling characteristics using design of experiment containing 4 elements were investigated for an optimal condition for the best motorcycle disk break system employing Taguchi robust experimental design. From this study, the result was shown that vents have an effect on convection area improving more cooling ability and reduced wear of the disk.

  • PDF

A Study on Concentration of Volatile Organic Compounds in the Apartment House (실내공기중의 휘발성유기화합물 농도변화에 관한 연구)

  • Lee, Yun-Gyu
    • KIEAE Journal
    • /
    • v.4 no.3
    • /
    • pp.129-136
    • /
    • 2004
  • Recently, indoor air pollution has been seriously apprehended, and became a striking issue, due to the airtightness of buildings or the misuse of building materials. Especially, SHS(Sick House Syndrome) and MCS(Multi Chemical Sensitivity) which can have bad influences on the resident in an existing apartment house as well as newly constructed apartment house start to attract public attention. The emission rates of VOCs is sensitively affected by the indoor/outdoor condition, construction materials, construction method, and character of ventilation facilities. Therefore, in this study, by measuring the indoor air pollution substance of the existing apartment house, the problem over this tends to be grasped and it is going to secure an improvement methods.

Energy Saving Effect of ERV(Energy Recovery ventilator) with Economizer Control in Residential Building (Economizer cycle control을 채용한 전열교환시스템의 에너지 절감효과 분석 -국내 공동주택을 대상으로-)

  • Park, Jae-Hyung;Kim, Joo-Wook;Song, Doo-Sam;Yoon, Ho-Young;Kim, Sung-Woo
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.679-684
    • /
    • 2009
  • ERV system has installed in almost newly constructed residential building in Korea. Heat recovery features of ERV can be possible to decrease the heating and cooling load caused by ventilation. However, in case of the outdoor condition is favorable to control the indoor air, the heat recovery function of ERV does more harm than good in term of cooling load. In this study, the ERV with economizer cycle control for residential building is suggested and the performance of the suggested system will be analyzed using TRNSYS.

  • PDF

A Study on Surveying Consumers' Needs for Developing the Future Kitchen (미래부엌 개발을 위한 소비자 요구 조사 연구)

  • 이연숙;양지안
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 1999.04a
    • /
    • pp.53-56
    • /
    • 1999
  • The purpose of this study was to diagnose the characteristics of current use of kitchen and scrutinize what to improve for the future kitchen development. To achieve the purpose, the small group wordshop panel was used. Two groups of 5 housewives per each were employed. For each group, there were a total of 3 consecutive meetings including 2 workshops and 1 field survey in each subject's house. The contents dealt with in the panel were as follows. First, actual condition and problems of using kitchen; second , possible solutions of the problems; third, needs for developing future kitchen. The major results were first, consumers require bigger kitchens to accomodate a variety of family activities ; second, kitchen needed to be more open encouraging family interaction and gave organic relationship to adjacent such as living room and utility room; third, due to korean cooking style, poor ventilation along with wet trash disposal was a serious problem. In addition to these. there revealed many problems which need to be improved and valuable ideas for the improvement.

  • PDF