• 제목/요약/키워드: Ventilation condition

검색결과 443건 처리시간 0.022초

포도흰얼룩증상의 발생생태적 특성 (Ecological Characteristics of White Stain Symptom on the Grape in Korea)

  • 오소영;남기웅;윤덕훈
    • 한국환경농학회지
    • /
    • 제33권3호
    • /
    • pp.178-183
    • /
    • 2014
  • BACKGROUND: The white stain symptom of grape clusters and canes by dust-like particles occurred in many vineyards recently. This study was conducted to investigate the ecological characteristics of white stain symptom in grapevines and vineyards. METHODS AND RESULTS: Optimal climate condition for white stain symptom was $25^{\circ}C{\sim}30^{\circ}C$ with 60% of humidity. Moreover, closed condition with same humidity showed higher incidence rate of white stain symptom than ventilation condition. Grape varieties with black berry skin such as Campbell-Early and Kyoho were more sensitive to white stain symptom compare to varieties with green and red berry skin. Although the pathogens were not detected until March, they increased from April, and increased sharply from mid of July. The pathogens may overwinter in the infected stems and/or on the bark as a mycelium. According to the increase of sugar content of grape from August to September, the mycelium which was parasitic on the bark grew to move to the fruits through the stems, and finally reached the fruit stalk to detach berries from the clusters. CONCLUSION: Well ventilation is recommended inside the vineyard since mid-July with roll up an insect net. In addition, infected stems and fruits should be removed out from grapevines infected with pathogens in the vineyards.

환기가 제한된 두 개 격실 화재에서 FDS 검증분석 (Validation of FDS for Fire in Underventilated Condition with Two rooms)

  • 배용범;금오현;김윤일;류수현;김위경;박종석
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 추계학술논문발표회 논문집
    • /
    • pp.438-443
    • /
    • 2008
  • Fire model shall be verified and validated to reliably show the predictive capabilities for a specific use. In the process of model verification and validation, both the acceptable uses and limitation of fire model are established. In this study, the results of FDS simulation are compared with the data of PRISME experiment such as temperature, heat release rate, heat flux, product concentrations in the under-ventilated two-room condition. Furthermore, the sensitivity of FDS under ventilation condition changes are evaluated. FDS provide the reliable prediction for under-ventilated two-room fire scenario with slightly deviation.

  • PDF

전통주거(傳統住居) 공간의 생리적(生理的) 특성(特性)에 관한 연구 - 전북지방 농촌주택(農村住宅)을 중심으로 - (A study on the Physiological Character of living Space in Traditional Koaean House - Focsed on the rural house in Chonbuk province -)

  • 김용집
    • 건축역사연구
    • /
    • 제8권2호
    • /
    • pp.59-72
    • /
    • 1999
  • The purpose of this study is to find the spatial factors, strucure of living and activity in traditional Korean house through the Phiysiological view, Spatial factors of the house are concerned to the interior environment and sanitary condition, The elements of respiratory, nerve, temperature sence. vision, hearing, smelling have good condition and touch, pressure sence, pain, metabolism are poor in the house, Ventilation, Lighting, pleasant condition of interior environment are concerned to the elements that mentioned above and have most important meaning in the relation rate of space as 1st factor. And 2nd factor is for metabolism, housework and rest, 3rd factor ie for temperature sence, privacy and reproduction. The relation rate of factors concering interior environment are high in the upper class house. Anbang has important meaning in the relation of living structure and relation sequence of space is anbang, Konnonbang, kitchen, toilet, water place, auxiliary buildings. The relation rate of activity is high in interior space in winter and exterior space in summer.

  • PDF

A Prediction of the Indoor Air Movement and Contaminant Concentration in a Multi-Room Condition

  • Song, Doo-Sam;Kang, Ki-Nam;Park, Dong-Ryul
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제15권3호
    • /
    • pp.137-146
    • /
    • 2007
  • CFD simulation is a very useful tool to predict the concentration of contaminant generated from the building materials in a single room. However, there is a limitation on analyzing air movement and contaminant concentration in a multi-room when the door of each room is closed. In this study, network based simulation was coupled with contaminant simulation for the multi-room condition, using an network simulation tool 'ESP-r'. The coupled simulation was first validated with experimental measurements which performed to define the characteristics of the analyzed space prior to the simulation, and indoor air flow and contaminant concentration between rooms were then analyzed when the door of each room was open and closed in the case of natural and forced ventilation.

스마트 TMD를 이용한 개폐식 대공간 구조물의 지진응답제어 (Seismic Response Control of Retractable-roof Spatial Structure Using Smart TMD)

  • 김현수;강주원
    • 한국공간구조학회논문집
    • /
    • 제16권4호
    • /
    • pp.91-100
    • /
    • 2016
  • A retractable-roof spatial structure is frequently used for a stadium and sports hall. A retractable-roof spatial structure allows natural lighting, ventilation, optimal conditions for grass growth with opened roof. It can also protects users against various weather conditions and give optimal circumstances for different activities. Dynamic characteristics of a retractable-roof spatial structure is changed based on opened or closed roof condition. A tuned mass damper (TMD) is widely used to reduce seismic responses of a structure. When a TMD is properly tuned, its control performance is excellent. Opened or closed roof condition causes dynamic characteristics variation of a retractable-roof spatial structure resulting in off-tuning. This dynamic characteristics variation was investigated. Control performance of a passive TMD and a smart TMD were evaluated under off-tuning condition.

실내건축의 작업환경 개선을 위한 기본적 관리방안에 관한 연구 (A Study on the Environmental Improvement in the Interior Construction Fields with the check-list)

  • 이용의
    • 한국실내디자인학회논문집
    • /
    • 제9호
    • /
    • pp.10-17
    • /
    • 1996
  • With the ever-increasing important of high-speed information in society as we move towards the 21 st century. Interior design and it's working condition has been changed a great deal included a sort of each special character and make a difference against the others. It used to be find a great poles asunder of worker's safety and project quality according to the environmental dimension of interior construction field as if they should be a pleasantness or poor condition. This research aimed to improvement of environmental construction field of interior with construction engineers and particular interior labors in 4 phases as : ⅠThe preparatory phase : -Secure a Budget, Environmental safety supervisor -Fix of Design quality, Construction period. -Choice of Construction method, Sub constructing Ⅱ. Starting work phase ; -Capacity , Safety of temporary power line. -Carriage, Stock of Material -Safety of Electronic tools, -Personal protector. Ⅲ. Working period ; -Ventilation, I illumination of working place. -Measurement of environmental working condition Ⅳ.Finish working phase ; -Analysis of measurement data. -Evaluation and making up for the weak point. -Keeping data.

  • PDF

구획실 화재 현상에 대한 수평 개구부 위치의 영향 검토 (Examination on Effect of Horizontal Vent Position on Fire Phenomena in Enclosure)

  • 박유미;이치영
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 봄 학술논문 발표대회
    • /
    • pp.235-236
    • /
    • 2022
  • In the present study, the effect of horizontal vent position on fire phenomena in the enclosure with vertical and horizontal vents was examined using numerical simulation. Case 1 indicates the condition that the horizontal vent is in the center of the ceiling. Case 3 indicates the condition that the horizontal vent is far away from the vertical vent. Case 2 indicates the condition that the horizontal vent is installed between Case 1 and Case 3. The temperature distribution, smoke layer temperature, velocity distribution, and mass flow rate of horizontal vent flow were analyzed. In Case 2, the temperatures were lowest and the mass flow rate through the horizontal vent was largest. This is because the flame is inclined by the inflow through the vertical vent. Hence, to determine the proper horizontal vent location for the high smoke ventilation performance, the inflow through the vertical vent and its effect on flame behavior should be considered.

  • PDF

월동용 양봉사의 환기팬 작동방식에 따른 온 ${\cdot}$ 습도 조절효과 (Control Effect of Temperature and Humidity by Ventilation Fan Operation Methods in Wintering Honey Bee House)

  • 이종원;이현우;이석건;김란숙;최광수
    • 생물환경조절학회지
    • /
    • 제12권3호
    • /
    • pp.127-131
    • /
    • 2003
  • 본 연구에서는 양봉사 내부환경을 보다 효율적으로 조절할 수 있는 환기팬 작동방식을 구명하기 위하여 시뮬레이션을 통해 얻어진 환기팬 작동방식에 대한 연 구결과를 양봉사에 직접 적용하여 실험을 실시하였으며, 양봉사 내부의 온도 및 습도변화에 대한 시율레이션과 실험결과를 비교 ${\cdot}$ 분석하여 양봉사 설계시 양봉사 열환경 해석 프로그램의 적용성을 검토하고, 실험결과를 이용하여 환기팬 작동방식별 양봉사 내부환경의 조절 성능을 분석하였다. 기 개발된 양봉사 열환경 해석 프로그램은 앞으로 양봉사 설계에 적절하게 이용할 수 있을 것으로 판단되었다. 외부기온이 비슷한 조건에서는 환기팬 작동방식 B의 경우가 A의 경우보다 양봉사의 내부온도가 대체로 더 낮았으며, 평균적으로 벌통 내부는 2.8$^{\circ}C$, 양봉사 내부는 2.1$^{\circ}C$ 더 낮았다. 이것은 Lee 등(1998b)이 제시한 환기팬 작동방식에 따라 양봉사 내부의 승온억제를 최고 2.8$^{\circ}C$까지 할 수 있다는 내용을 뒷받침하는 실험결과이다. 환기팬 작동방식 A와 B 모두 꿀벌이 월동하기에 적합한 상대습도 범위 (50~75%) 였으나, 방식 B가 A 보다 양봉사 내부 습도의 최고 및 최저편차가 약 2%, 평균습도가 약 5% 적게 나타나 습도환경조절에 있어 좀 더 안정적인 것으로 판단되었다. 따라서 환기팬 작동방식 B는 A 에 비하여 양봉사 내부환경조절 성능이 더욱 우수하고 효율적인 것으로 판단되었다.

밀폐공간작업을 하는 산업의 관리와 실태조사 (Control and status of Industries with Confined Space)

  • 양홍석;방상수;강경식
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2003년도 추계학술대회
    • /
    • pp.65-69
    • /
    • 2003
  • The study was purposed to know the status of prevention on health obstacle in industries with confined space. The results were as follows: 1. It was found 38% of respondents established health-work program in confined space. The percentage of respondents with instrument of oxygen sampling and equipment of ventilation, operation of safety and health education, posting of watching man and operation of head count were 42%, 35%, 75%, 46% and 56%, respectively. 2. The percentage of awakening of risk, confirm of air condition and operation of emergency training were 36%, 25% and 10%, respectively.

  • PDF