• Title/Summary/Keyword: Ventilation Type

Search Result 471, Processing Time 0.027 seconds

A Numerical Study on Ventilation Characteristics of Factors Affecting Leakages in Hydrogen Ventilation (누출 수소 환기에 영향을 미치는 요인별 환기 특성에 관한 수치해석적 연구)

  • Lee, Chang-Yong;Cho, Dae-Hwan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.4
    • /
    • pp.610-619
    • /
    • 2022
  • Hydrogen is emerging as an alternative fuel for eco-friendly ships because it reacts with oxygen to produce electrical energy and only water as a by-product. However, unlike regular fossil fuels, hydrogen has a material with a high risk of explosion due to its low ignition point and high flammability range. In order to safely use hydrogen in ships, it is an essential task to study the flow characteristics of hydrogen leakage and diffusion need to be studied. In this study, a numerical analysis was performed on the effect of leakage, ventilation, etc. on ventilation performance when hydrogen leaks in an enclosed space such as inside a ship. ANSYS CFX ver 18.1, a commercial CFD software, was used for numerical analysis. The leakage rate was changed to 1 q, 2 q, and 3 q at 1 q = 1 g/s, the ventilation rate was changed to 1 Q, 2 Q and 3 Q at 1 Q = 0.91 m/s, and the ventilation method was changed to type I, type II, type III to analyze the ventilation performance was analyzed. As the amount of leakage increased from 1 q to 3 q, the HMF in the storage room was about 2.4 to 3.0 times higher. Furthermore, the amount of ventilation to reduce the risk of explosion should be at least 2 Q, and it was established that type III was the most suitable method for the formation of negative pressure inside the hydrogen tank storage room.

Study on the Performance of the Separate type Heat Pipe Using the Parallel Flow type Heat Exchanger (평행류형 열교환기를 이용한 분리형 히트파이프의 성능에 관한 연구)

  • Jeon, Sung-Taek;Cho, Jin-Pyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.8
    • /
    • pp.5045-5050
    • /
    • 2015
  • As modern houses are constructed with high-density and high-insulation, there is benefit to reduce energy consumption, but there are many side effects raised from polluted air. To solve the problem, a ventilation system is used to improve a indoor air quality. In this study, we tested the parallel flow type heat exchanger used in a heat exchanger of an automotive air conditioner. And we experimentally estimate ventilation performance of HRV(heat recovery ventilator) with heat-pipe according to working fluid filling quantity and ventilation. The working fluid was R22, which was filled from 40 to 60 (%vol.) by 10(%vol.). Ventilation based on the front velocity was measured from 0.3 m/s to 1.5 m/s by 0.3 m/s intervals. Refrigerant filling quantity with the highest efficiency was found to depend on the ventilation. From this study the optimal refrigerant filling quantity in accordance with the ventilation of the detachable heat pipes was found experimentally.

Method of Ventilation by Gas Chromatography and the Effects of the Type of Blouse (G.C를 이용한 Ventilation 측정방법과 Ventilation에서의 블라우스형태변화의 영향)

  • Park Woo Mee;Choi Chul Ho
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.16 no.1 s.41
    • /
    • pp.53-63
    • /
    • 1992
  • The purpose of this study is to investigate the method of trace gas technique by G.C and the effects of the type of blouse on ventilation. The experimental system employed a trace gas technique in which ventilation was monitored to determine oxigen exchange rate. The experimental variables were tested with three types of blouse depending on the sizes of neckline, armhole and waist line. Exercise conditions include standing and walking position. The results and discussion forcused on the construct validity of the apparatus/testing protocol. the effect of experimental variables on ventilation was also discussed.

  • PDF

An Optimized Design and Simulation Analysis of Natural Ventilation Window System classified by Apartment type (주거용 건물 유형별 자연환기시스템의 최적 설계 및 해석)

  • Choi, Gyeong-Seok;Jeong, Young-Sun;Kang, Jae-Sik;Lee, Seung-Eon;Jeong, Yeong-Yong
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.685-688
    • /
    • 2009
  • On account of Indoor Air Quality(IAQ) deterioration by reason of high insulation and air tightness for energy saving, absence of energy efficiency ventilation system development that can be domestic existing window system, the cost increase and the energy addition loss by mechanical ventilation for IAQ improvement, the ventilation obligation making design standard was prepared by a social and technical background and the necessity. In this study, an optimized design and simulation Analysis of natural ventilation window system classified by Apartment type was evaluated by CFD Computational analysis.

  • PDF

A Study on the Simulation of Natural Ventilation Effect for Single-sided Casement Window as Opening Types (케이스먼트 창호 개폐방식에 따른 자연환기 효과에 관한 시뮬레이션 연구)

  • Choi, Taehwoan;Kim, Taeyeon;Leigh, Seung-Bok
    • KIEAE Journal
    • /
    • v.7 no.4
    • /
    • pp.57-62
    • /
    • 2007
  • At the moment, the reduction of building energy consumption is a unavoidable task of mankind for conserving global environment. Decreasing overall U-value of building envelope and air infiltration, especially in Korean climate condition with clear four seasons, are the obvious solutions for the objective. Thus low glazing ratio with small window openings are required for heating and cooling load reduction in buildings. Using larger window openings could provide better natural ventilation but it also increases the direct solar radiation penetration into indoor space, heat gain in summer and heat loss in winter. On the other hand, the ventilation rates decreasing problem with smaller window openings could be occurred. As a solution for it, the use of casement window can cause increasing natural ventilation rates by wing wall effect. This paper focuses on deduce the most efficient opening type of casement window in Korean climate. To estimate ventilation performance of each opening types, CFD simulation was used. The best performance of opening type in every wind direction is opening both windows to the center and the most appropriate opening type for Korean climate is also opening both windows to center.

Study on Application of Shaft Box type Balcony for Improvement of Ventilation Performance in Apartment (공동주택의 환기성능 개선을 위한 Shaft Box형 발코니의 적용성 검토)

  • Roh, Ji-Woong;Kim, Gon
    • KIEAE Journal
    • /
    • v.7 no.6
    • /
    • pp.3-8
    • /
    • 2007
  • Recently, because of the continuous rise of international oil price, energy saving is strongly demanding. So, Ecological technics of architecture such as use of natural energy have been actively explored in the field of building. In the method of utilizing natural energy, the key point is to saving energy effectively as not lowering the comfort of indoor environment, various systems investigated. Many papers about double skin facade system have been reported, it is announced broadly that the system is very effective in improvement of natural ventilation and indoor thermal environment, and also protecting outdoor sound. The shaft box facade is a special form of box window construction. It consists of a system of box windows with continuous vertical shafts that extend over a number of stories to create a stack effect. The facade layout consists of an alternation of box windows and vertical shaft segments. This research investigated the natural ventilation performance of shaft box type balcony which conform the shaft box type double skin to the exiting balcony construction. First, analyzed various types of exiting apartments, proto-type was decided. By using virtual environment Program, modeling the proto-type, compared the contribution of air temperature and the effect of outdoor air cooling. by this research, we confirmed that shaft box type balcony had many possibility for improvement of indoor environment.

A Comparative Analysis of Energy Performance according to the Ventilation System in Apartment House (공동주택의 환기시스템별 에너지성능 비교 분석)

  • Kim, Gil-Tae;Chun, Chu-Young;Kim, Sun-Dong
    • Land and Housing Review
    • /
    • v.6 no.4
    • /
    • pp.215-220
    • /
    • 2015
  • The purpose of this study was to comparative analyses of energy performance in apartment houses adopted window frame-type natural ventilation, under-floor air distribution ventilation and heat recovery ventilation. As the object of energy simulation, the three type ventilation system with area of $84m^2$ was selected in apartment house. As a result, when the ECO2 simulation was performed, the 1st requirement quantity per annual were $159.9kWh/m^2yr$(CASE1, Natural Ventilation), $179.7kWh/m^2yr$(CASE2, Under-floor Air Distribution Ventilation) and $161.0kWh/m^2yr$(CASE3, Heat Recovery Ventilation).

The Analysis on the Variation of the Ventilation Rates by Wind Pressure and Temperature Difference between Indoor and Outdoor in the Multi-Story Type Double Skin Facade applied to the Office Building (오피스 건물에 적용된 다층형 이중외피의 풍압과 실내·외 온도차에 의한 환기량 변화 분석)

  • Song, Chi-Ho;Kim, Teayeon;Leigh, Seung-Bok
    • KIEAE Journal
    • /
    • v.15 no.2
    • /
    • pp.123-131
    • /
    • 2015
  • Purpose : Improvement of indoor thermal comfort and reduction of the energy consumption in building can be obtained by applying a double skin facade system. In order to achieve effectively this purpose, design team would have to perform easy and appropriate performance analysis for making better design decision during the design process. Method : This paper focus on the natural ventilation performance of a multi-story type double skin facade with main causes which are pressure difference according to the wind and temperature difference between indoor and outdoor (Buoyancy Effect). Using this main causes, the natural ventilation ratio of wind effect-to-buoyancy effect in cavity of multi-story type double skin facade were analyzed through the performance analysis results of CFD (Computational Fluid Dynamics) simulation. Result : When the wind velocity was 2m/s, the ventilation rate in the cavity was highest. If wind velocity was slower than 2m/s wind velocity, buoyancy effect has more influence on the ventilation rate in the cavity, and if wind velocity was faster than 2m/s wind velocity, wind effect has more influence on the ventilation rate in the cavity.

Analysis of Indoor Air & thermal environment with Hybrid Ventilation system during summer (하계 공동주택 하이브리드 환기시스템 적용에 따른 실내공기 및 열 환경 평가)

  • Kim, Sang-Jin;Kim, Eun-Soo;Kim, Tae-Yeon;Leigh, Seung-Bok
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.387-392
    • /
    • 2006
  • The recent on indoor air problem has led to many studies on the methods and effects of ventilation for better indoor air quality. Although natural ventilation is the most effective and energy-saving method in residental housings, the small size of openable window has been a problem in high-rise residential buildings to ventilate only through natural ventilation. Consequently, the installation of mechanical ventilation system has been a requirement in residential buildings, and has caused other problems such as increase of energy consumption and SBS. Hybrid ventilation which uses forces of both natural and mechanical power has been introduced to solve the problem of increase in energy consumption with natural ventilation. In this paper, two types of hybrid ventilation systems in residential building were introduced. One type was with natural ventilation through vent grille in the window, and another type was with natural ventilation through ceiling duct while both types used mechanical ventilation system with the outlets. The indoor temperature distribution and pollution density distribution in summer while operating the ceiling air conditioner were analyzed through CFD simulation. In this paper, the optimal location of diffusers to achieve thermal comfort would be proposed.

  • PDF

Optimization of a Ventilation System for Indoor Environment Improvement in School Building (학교교실의 환경개선 환기시스템 최적화 기반 연구)

  • Suh, Seung-Jik;Hong, Sung-Hee;Park, Hyo-Soon;Park, Jong-Hoon;Jang, Yong-Sung
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.229-234
    • /
    • 2005
  • This study aims to build basic data for a optimization of a ventilation system for indoor environment improvement in school building. To this end, we conducted field tests and computation fluid dynamics simulations about a indoor environment in dependence on operation of a ceiling type inverter air conditioner and ventilation system. The results could be summarized as follows. (1) For the ventilation system of 350CMH, 500CMH and 850CMH, reduction of each $CO_2$ concentration was measured 662ppm, 748ppm and 526ppm. (2) A optimal discharge angle of the ceiling type inverter air conditioner system was evaluated 45 degree in heating and cooling.

  • PDF