A Study on Improvenment of Livingroom Smoke-control System using the FDS (화재 시뮬레이션(FDS)을 이용한 거실제연설비 개선에 관한 연구)

  • Kim, Mi-Seon;Baek, Eun-Seon
    • Fire Science and Engineering
    • /
    • v.31 no.4
    • /
    • pp.26-34
    • /
    • 2017
  • The purpose of this study is to identify and improve the performance of the adjacent room ventilation system in living room ventilation facilities, and compare and analyze the smoke control regulations of the NFPA code and the national fire safety standard (NFSC). The analysis method was fire dynamics simulation (FDS) and was used to analyze the, variations of the air supply amount, width of the boundary, change in indoor combustion and wind velocity of the incoming air. It was found to be advantageous to secure the clean layer when the amount of air supplied is less than the amount of discharged air in the fire room. However, in the supply room, it is more effective to secure the clean layer when the amount of supplied air is larger than the amount of discharged air, as a longer boundary width gives rise to better performance. In addition, it is necessary to consider the amount of air supplied and discharged as a function of the kind of flammable material. Moreover, decreasing the air inlet wind speed and amount of incoming air is advantageous for securing the clean layer of the fire room.

Acute Hydrogen Cyanide Poisoning in a Plating Worker and Workplace Measurement (도금 사업장 근로자에게 발생한 시안화수소 급성중독과 작업환경평가)

  • Ham, Seunghon;Choi, Won-Jun;Lee, Junhyung;Lim, Yong su;Kang, Jihyun;Kang, Seong-Kyu
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.29 no.3
    • /
    • pp.336-342
    • /
    • 2019
  • Introduction: An unexpected death was reported in a beginner immediately after starting the work at a plating factory. After the incident, air sampling was performed using a simulation of the situation as it had been at the time. Methods: To evaluate the airborne concentration of hydrogen cyanide, a total of six samples were collected: one personal sample, three area samples, and two background samples (office and outdoors). Hydrogen cyanide measurement was performed according to the standard sampling protocol recommended by the U.S. NIOSH (National Institute of Occupational Safety and Health). Results: The highest concentration of hydrogen cyanide was 0.938 ppm measured in a sample collected from the plating bath area with local exhaust ventilation. This value was approximately 20% of the ceiling occupational exposure limit. The personal sample showed a concentration of 0.135 ppm. Samples collected near the bath in which the incident occurred and a dehydrator showed hydrogen cyanide concentrations of 0.236 ppm and 0.101 ppm, respectively. Hydrogen cyanide was not detected in the background samples (office and outdoors). Conclusions: It is necessary to use proper ventilation systems and respirators in plating factories to prevent acute poisoning. Furthermore, it is important to educate and train new workers dealing with toxic substances.

The effect of high fat dietary modification and nutritional status on the outcome of critically ill ventilated children: single-center study

  • El Koofy, Nehal Mohamed;Rady, Hanaa Ibrahim;Abdallah, Shrouk Moataz;Bazaraa, Hafez Mahmoud;Rabie, Walaa Ahmed;El-Ayadi, Ahmed Ali
    • Clinical and Experimental Pediatrics
    • /
    • v.62 no.9
    • /
    • pp.344-352
    • /
    • 2019
  • Background: Ventilator dependency constitutes a major problem in the intensive care setting. Malnutrition is considered a major determinant of extubation failure, however, attention has been attracted to modulating carbon dioxide production through decreasing carbohydrate loading and increasing the percent of fat in enteral feeds. The detected interrelation between substrate oxidation and ventilation outcome became the base of several research to determine the appropriate composition of the nonprotein calories of diet in ventilated patients. Purpose: We aimed to assess the effect of high-fat dietary modification and nutritional status on ventilatory and final outcomes of pediatric intensive care. Methods: Fifty-one ventilated children (1 month to 12 years of age) with pulmonary disease who could be enterally fed, in the Cairo University Pediatric intensive care unit, were divided into 2 groups: group A included 25 patients who received isocaloric high-fat, low-carbohydrate diet; group B included 26 patients who received standard isocaloric diet. Comprehensive nutritional assessment was done for all patients. Results: Group A had a significant reduction in carbon dioxide tension, but no similar reduction in the duration or level of ventilatory support. Assisted minute ventilation was predicted by weight-for-age and caloric intake rather than the type of diet. Poor nutritional status was associated with higher mortality and lower extubation rates. Mild hypertriglyceridemia and some gastrointestinal intolerance were significant in group A, with no impact on the adequacy of energy or protein delivery. Conclusion: The high-fat enteral feeding protocol may contribute to reducing carbon dioxide tension, with mild hypertriglyceridemia and negligible gastrointestinal intolerance as potential adverse effects. Optimization of nutritional status rather than dietary modification may improve ventilatory and survival outcomes in critically ill-ventilated children.

The effects of remdesivir on mortality and the requirement for mechanical ventilation in patients with COVID-19: a systematic review stratified by disease severity

  • Seungeun Ryoo;Miyoung Choi;Su-Yeon Yu;Young Kyung Yoon;Kyungmin Huh;Eun-Jeong Joo
    • The Korean journal of internal medicine
    • /
    • v.39 no.1
    • /
    • pp.160-171
    • /
    • 2024
  • Background/Aims: The effectiveness of remdesivir treatment in reducing mortality and the requirement for mechanical ventilation (MV) remains uncertain, as randomized controlled trials (RCTs) have produced conflicting results. Methods: We searched MEDLINE, EMBASE, Cochrane Central Register of Controlled Trials, and other data resources to find RCTs published prior to April 10, 2023. The selection of studies, assessment of risk of bias, and meta-analysis were conducted according to PRISMA guidelines. The primary outcomes were all-cause mortality and the need to initiate MV. Results: A total of 5,068 articles were screened, from eight RCTs comprising 11,945 patients. The meta-analysis found that, compared to standard care or placebo, remdesivir treatment provided no significant all-cause mortality benefit (pooled risk ratio [RR], 0.93; 95% confidence interval [CI], 0.85-1.02; 8 studies; high certainty evidence), while subgroup analyses revealed a trend towards reduced mortality among patients requiring oxygen but not MV (pooled RR, 0.88; 95% CI, 0.77-1.00; 6 studies; I2 = 4%). The need to initiate MV (pooled RR, 0.74; 95% CI, 0.59-0.94; 7 studies; moderate certainty evidence) in remdesivir-treated patients was also reduced compared to controls. Remdesivir significantly increased clinical improvement and discharge and significantly reduced serious adverse events. Conclusions: In this systematic review and meta-analysis of RCTs, it was found that remdesivir treatment did not show a substantial decrease in the risk of mortality. However, it was linked to a reduction in the necessity for additional ventilator support, suggesting remdesivir could be beneficial for COVID-19 patients, particularly those who are not on MV.

A Study on Environmental Standards of School Building (교사환경기준에 관한 연구)

  • Hong, Seok-Pyo;Park, Young-Soo
    • The Journal of Korean Society for School & Community Health Education
    • /
    • v.1 no.1
    • /
    • pp.11-43
    • /
    • 2000
  • The purpose of this study was, through analyzing the previous researches, to grasp the present status of environment of school building(ESB), research the sundry records of each element and, through comparative analysis of the standard of ESB in Korea, the United States, and Japan, select the normative standard of ESB, to clarify the point at issue presented in Regulation of Construction & facility Management for Elementary and and Secondary School in Korea, and to suggest an alternative preliminary standard of ESB. To carry out a research for this purpose, these were required: 1. to investigate the existing present status of ESB, 2. to make a comparative analysis of the standard of ESB in each country, 3. to suggest the normative standard of preliminary standard of ESB, 4. to analyze the controversial points of the standard of ESB in Korea, 5. to suggest an alternative preliminary standard of ESB. The conclusions were as follows: 1. Putting, through analyzing the previous researches, the existing present status of ESB together, it seemed that lighting environment, indoor air environment and noise environment were all in poor conditions. 2. In the result of a comparative analysis of the standard of ESB in Korea, Japan and the United States, in Korea the factors of each lighting and indoor air environment were not presented properly, in Japan, in lighting environment aspect, the standard on natural lighting and the factors on brightness were not presented., and in the USA the essential factors of each environment were throughly presented. In the comparison of the standards on each factor, Korea showed that the standard level presented was less properly prescribed than those of the USA and Japan but it also showed that the standard levels prescribed in the USA and in Japan were mostly similar to the standard levels in records investigated. 3. With the result of the normative standard selection on School Builiding environment factor of prescribed in this study, the controversial points of the standard of ESB in Korea were analyzed and the result was utilized to suggest new preliminary standard of ESB. 4. As the result of the analysis of the controversial points of the standard of ESB in Korea, it was found that the standard of ESB in Korea should be established on a basis of School Health Act and be concretely presented in School Health Regulation and School Health Rule. The factors of each environment was improperly presented in the existing standard of ESB in Korea. Moreover the standard of them was inferior to that of the records investigated and those of in the USA and in Japan and it also showed that the standard of it in Korea was improper to maintain Comfortable Learning Environment. 5. A suggested preliminary standard of ESB acquired through above study as follows: 1) In this study a new kind of preliminary standard of ESB is divided into lighting environment, indoor air environment, noise environment, odor environment and for above classification, reasonable factor and standard should be established and the controling way on each standard and countermeasures against it should be considered. 2) In lighting environment, the factors of natural lighting are divided into daylight rate, brightness, glare. In the standard on each factor, daylight rate should secure 5% of a mean daylight rate and 2% of a minimum daylight rate, brightness ratio of maximum illumination to minimum illumination should be under 10:1, and in glare there should not be an occurrence factor from a reflector outside of the classroom. And the factors of unnatural lighting are illumination, brightness, and glare. In the standard on each factor, illumination should be 750 lux or more, brightness ratio should be under 3 to 1, and glare should not occur. And Optimal reflection rate(%) of Colors and Facilities of Classroom which influences lighting environment should be considered. 3) In indoor air environment factors, thermal factors are divided into (1) room temperature, (2) relative humidity, (3) room air movement, (4) radiation heat, and harmful gases (5) CO, (6) $CO_2$ that are proceeded from using the heating fuel such as oval briquettes, firewood, charcoal being used in most of the classroom, and finally (7) dust. In the standard on each factor, the next are necessary; room temperature: $16^{\circ}C{\sim}26^{\circ}C$(summer : $E.T18.9{\sim}23.8^{\circ}C$, winter: $E.T16.7{\sim}21.7^{\circ}C$), relative humidity: $30{\sim}80%$, room air movement: under 0.5m/sec, radiation heat: under $5^{\circ}C$ gap between dry-bulb temperature and wet-bulb temperature, below 1000 ppm of ca and below 10ppm of $CO_2$, dust: below 0.10 $mg/m^3$ of Volume of dust in indoor air, and ventilation standard($CO_2$) for purification of indoor air : once/6 min.(about 7 times/40 min.) in an airtight classroom. 4) In the standard on noise environment, noise level should be under 40 dB(A) and the noise measuring way and the countermeasures against it should be considered. 5) In the standard on odor environment, odor level under Physical Method should be under 2 degrees, and the inspecting way and the countermeasures against it should be considered.

  • PDF

The Characteristics of Indoor Air Quality Variation in Underground Parking Lots of Apartments located in Northern Gyeonggi Province (경기도 북부지역 아파트의 지하주차장 실내공기질 변동 특성)

  • Park, Hyun-Ku;Jung, Yeon-Hoon;Kim, Byeong-Lok;Kim, Jin-gil;Shin, Hyung-Soon;Lee, Sang-Soo;Oh, Jo-Kyo
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.3
    • /
    • pp.250-258
    • /
    • 2018
  • Objectives: The study examined indoor air quality during daytime and commute times in underground parking lots in five apartments located in northern Gyeonggi province. Methods: This study examined the temporal characteristics of $PM_{10}$, $CO_2$, CO, HCHO and VOCs in the indoor air quality of the underground parking lots in five apartments. Results: $PM_{10}$ concentration in daytime were ranged from 37.4 to $69.9{\mu}g/m^3$ which complied with the indoor air quality maintenance standard ($200{\mu}g/m^3$) and Gyeonggi province ordinance standard ($180{\mu}g/m^3$). However $PM_{10}$ concentrations in commuting time were in range of $447.3{\sim}944.0{\mu}g/m^3$ that exceeded for both criteria. The $CO_2$, CO and HCHO concentrations complied with the standard. The VOCs indicated high tendency in the order of toluene, xylene, ethylbenzene and benzene. This tendency was more apparent in commuting time than daytime. Conclusion: All indoor parking lots of five apartments were equipped with ventilators. However the most apartment residents did not operate blowers to save electricity and the lack of interest for indoor air quality. In order to improve the indoor air quality of underground parking lots in apartment, operating ventilation system during commuting time is recommended.

A Study on Economical Efficiency Evaluation of Semiforcing under Structure Watermelon Cultivators (반촉성 시설수박 재배농가의 경제적 효율성 분석)

  • Kim, Woong;Kim, Jai Hong
    • Korean Journal of Agricultural Science
    • /
    • v.33 no.2
    • /
    • pp.179-193
    • /
    • 2006
  • Technical efficiency of semiforcing watermelon growers is 0.8248 on average, and distributed between 0.6744 and 0.9268. The result showed that semiforcing watermelon growers had by 18% of technical inefficiency and could be assumed that increasing technical efficiency could induce watermelon production more increase. Consequently, if growers' technical efficiency were improved while other environments were constant, watermelon production could be increased. Following the results from the inefficiency effect model, all assumption coefficient such as growers age etc, are significant at 10% level. Estimate of dispersion parameter ${\gamma}$ is 0.89, which confirms those differences between practical output and frontier output were derived from the technical efficiencies among growers. Differences of production system between high and low level growers in production efficiency were showed at side altitude, ventilation and heat-retaining in section of facilities and automation, soil test and calcium application in section of environment management, transplant preparation and duration of pollination in section of crop management and shipment place, sorting degree and management record analysis in section of business management respectively. As a result of analyzing consulting data by using standard diagnosis table of watermelon cultivation under structure which cultivated on semi-forced watermelon growers, gap between high and low level growers was 7.0 points in facility automation section, 7.1 points in environment section, 8.8 points in crop management section and 13.6 points in business management section, respectively, which were the biggest one among them. In case of excluding information-related items from the evaluation index of business management section, changes of business achievement are to occur. Therefore, it is recommended for us to review the standard diagnostic table of watermelon cultivation under structure by dividing evaluation index of management section into management and information.

  • PDF

Comparison of dexmedetomidine alone with dexmedetomidine and fentanyl during awake fiberoptic intubation in patients with difficult airway: a randomized clinical trial

  • Acharya, Ranjita;Sriramka, Bhavna;Koushik, Priyangshu
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.22 no.5
    • /
    • pp.349-356
    • /
    • 2022
  • Background: Awake fiberoptic intubation (AFOI) is the procedure of choice for securing the airway in patients with a difficult airway when undergoing surgeries under general anesthesia. An ideal drug would not only provide conscious sedation but also maintain spontaneous ventilation, smooth intubation conditions, and stable hemodynamics. We compared the effects of dexmedetomidine alone and dexmedetomidine in combination with fentanyl at a dose lower than the standard dose for achieving conscious sedation during AFOI in difficult airway patients undergoing oral cancer and dental surgeries. Methods: We included 68 adult patients undergoing AFOI. The patients were randomized in two groups, wherein Group D received intravenous dexmedetomidine 1 ㎍/kg and Group DF received dexmedetomidine 0.5 ㎍/kg and fentanyl 1 ㎍/kg. The outcomes measured were airway obstruction score, intubation scores, fiberoptic intubation comfort score, sedation score, and hemodynamic variables. Results: Low-dose dexmedetomidine with fentanyl showed similar results as those with the standard dose of dexmedetomidine in terms of airway obstruction, vocal cord movement, degree of cough, degree of limb movements, and intubation comfort. However, the sedation achieved and incidence of hypotension and bradycardia were higher in Group D than in Group DF. Conclusions: A low dose of dexmedetomidine-fentanyl provides satisfactory intubation conditions as those with a standard dose of dexmedetomidine in AFOI, thereby avoiding bradycardia, hypotension, and sedation.

Evaluation of Energy Loads for Broiler-Standard Design Models Using a Building Energy Simulation Method (건물에너지시뮬레이션 기법을 이용한 육계사 표준설계모델의 에너지 부하 산출)

  • Kwon, Kyeong-seok;Yang, Ka-young;Kim, Jong-bok;Jang, Dong-hwa;Ha, Taehwan;Jeon, So-ra
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.65 no.1
    • /
    • pp.27-39
    • /
    • 2023
  • This study was to quantitatively evaluate periodic and maximum energy loads for broiler-standard design models by the Ministry of Agriculture, Food and Rural Affairs (2016). Building energy simulation method was used to compute heating and cooling loads of the designed broiler houses according to regional locations and insulation characteristics of wall and roof. It considered sensible and latent heat generation from broilers, dynamic operation of ventilation system according to environment variations. It was found that variation of periodic heating loads was relatively higher than that of periodic cooling loads according to thickness changes of wall and roof. Assuming that broiler was raised at every even-month, periodic heating and cooling loads were 6 and 18% lower, respectively than odd-month raising condition. When recommendation rules of insulation characteristics (wall and roof thickness) by the Ministry of Land, Infrastructure and Transport was adopted, periodic heating load of Jeju-si was 20.3% higher than national average values. Based on the BES computed periodic and maximum energy loads under the designed experimental condition, these results can contribute to reestablishing standard design of broiler houses, especially for insulation characteristics, and designing management strategies for efficient energy uses.

Design Process of Outdoor-Wear for Improvement of Comfort and Appearance (운동기능성과 심미성을 고려한 아웃도어웨어의 디자인개발연구)

  • 박우미;박춘덕;이귀례;나정은
    • Journal of the Korean Society of Costume
    • /
    • v.52 no.8
    • /
    • pp.29-39
    • /
    • 2002
  • It was increased leisure hours by automation and computerization of industry. Many people spend on hours in enjoying leisure sports, and then. nowadays, Many women tend to prefer casual wear to formal suits. The purpose of this research was to design of outdoor-wear that improve the functional and aesthetic effects for clothing comfort. Total 4 design prototype consisting of jumper and slacks were developed for this research. Outdoor-wear design forced on armhole type of jumper and ease of the back crotch length of slacks to improve the functional and aesthetic effects. And Outdoor-wear design focused on color harmony to aesthetic effects. Ease amount and materials of jumper and slacks were controlled. Design A: Jumper was designed as dropped shoulder with set-in steeve and band collar, A break-away zipper to facilitate ventilation control were made the area of back of jumper and the area of outside seam line of slacks Color of jumper and slacks were olive green color. Ease amount of the crotch length of slacks pattern was constructed as 7% of total crotch length: Design B 4DM cut pattern were applied to the jumper and slacks pattern. A break-away zipper to facilitate ventilation control were made the area of back of jumper and the area of inside seam line of thigh. Color of jumper and slacks were grey and orange color. Ease amount of the crotch length of slacks pattern was constructed as 5% of total crotch length. Design C : Jumper was designed as the set in sleeve and hood. and A break- away zipper to facilitate ventilation control were made the ares of the armhole and elbow. Color of jumper and slacks were ivory and orange color. Ease amount of the crotch length of slacks pattern was constructed as 5% of total crotch length. Design D : Jumper was designed as raglan sleeve. Color of jumper and slacks were olive green color. Ease amount of the crotch length of slacks pattern was constructed as 5% of total crotch length. Total six females, ages 20-45, served as subjects for this research. Subjects have standard body type, generally, wearing 66 size of ready-to-wear clothing. The performance of the newly designed outdoor-wear was evaluated for their effectiveness in several aspects such as conditions of skin temperature, sensory evaluation of comfort during body movements, appearance and color harmony and aesthetic collar design. Design 3 was appeared to be the most positive in aesthetic evaluation and functional effects of design 2 of 4DM cut pattern was appeared to be beter than other designs.